Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 醫學工程學研究所
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/9210
Title: 椎弓根螺釘在疲勞負載時之鬆脫機轉分析
Analysis of Mechanics of Pedicle Screw Loosening During Fatigue Loadin
Authors: Sheng-Yuan Cheng
鄭勝元
Advisor: 王兆麟(Jaw-Lin Wang)
Keyword: 椎弓根螺釘,鬆脫,疲勞負載,震動,震盪頻率,
pedicle screw,looseness,fatigue,vibration,natural frequency,
Publication Year : 2009
Degree: 碩士
Abstract: Objective. To find the relationship between gap of screw-bone interface and pedicle screw pullout strength, and to develop a non-destructive test to predict the pullout strength of pedicle screw.
Summary of Background Data. Pedicle screw looseness is frequently observed after spinal implantation surgery. The X-ray image and computer tomography are used to diagnose the gap between screw and bone interface. Nevertheless, the correlation between gap of screw-bone interface and screw looseness is not clear. Pullout test of pedicle screw, which is a destructive testing method, is widely used to evaluate the strength of screw-bone interface in vitro. It usually costs large testing sample to predict the progression of screw looseness using this destructive testing method.
Materials and Methods. Sawbones and human cadaveric vertebra were used for this in vitro study. The specimens were divided into three groups, “intact”, “1mm gap” and “2mm gap” (n=10 for each group). The pedicle screws (diameter: 6mm, length: 40mm) were inserted. The fatigue loading apparatus was used to apply axial fatigue loading (20~200N, 5Hz) to the head of the screw to create the interface gap. The tensile-compressive testing apparatus was used to find the interface stiffness and pullout strength of pedicle screw. During the stiffness test, loading was applied on screw head at 20~200N magnitude and 1Hz frequency. The loading of impact testing apparatus was 50N, and the vibration frequency of pedicle screw was measured. During the pullout test, the pedicle screw was pullout axially from the specimen at 5 mm/min, and the maximum pullout force was measured. The relationships between interface stiffness, vibration frequency and pullout strength were analyzed.
Results. When the gap between pedicle screw and specimens was expanded to 1mm, the interface stiffness, vibration frequency and pullout strength of pedicle screw significantly decreased (p=0.00). The interface stiffness and vibration frequency are moderately (r=0.58, p=0.00) and highly (r=0.75, p=0.00) correlated to the pullout strength, respectively.
Conclusions. The pullout strength could be predicted by measuring the interface stiffness and vibration frequency. This method can be useful to predict the progression of screw looseness during fatigue loading.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/9210
Fulltext Rights: 同意授權(全球公開)
Appears in Collections:醫學工程學研究所

Files in This Item:
File SizeFormat 
ntu-98-1.pdf8.45 MBAdobe PDFView/Open
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved