Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 工程科學及海洋工程學系
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/76940
Title: 100nm精密對位之莫瑞條紋分析及13.5nm極紫外光光罩缺陷檢測

Accurate alignment of Moiré fringe within 100 nm and photomask defect detection by 13.5 nm extreme ultraviolet
Authors: Li-Hsuan Chung
鍾溧媗
Advisor: 李佳翰(Jia-Han Li)
Keyword: 莫瑞條紋,晶圓對位,傅立葉轉換,訊號處理,極紫外光光罩,同調繞射影像術,同調性散射顯微鏡,
Moiré fringe,Wafer alignment,Fourier transform,Signal process,Extreme ultraviolet(EUV) mask,Coherent scattering microscopy,
Publication Year : 2020
Degree: 碩士
Abstract: 在0.1μm的精準度之下,使用紅外光直接對準法所進行奈米級的光學檢測,光學系統可以通過條紋的放大特性直接檢測到莫瑞條紋。以直線型光柵分析x方向的偏移量、繞 z 軸的偏轉角,以方形中心對稱光柵分析 x、y 方向的偏移量,使用低通濾波器及快速傅立葉變換的方法來分析圖像的頻域項。在測量兩條紋的峰值的位置後,計算出兩個晶圓之間的偏移誤差量。
建構同調散射顯微鏡在 EUV 光罩檢測系統及雙軸平台的研發,以光點500μm之下量測到訊號光源及缺陷的繞射圖形,提供日後快速與高解析光罩之缺陷檢測。

Under the accurate alignment of 0.1μm, The optical system is used to infrared light directly alignment method which can be used for nano-level detection. The optical system can directly detect the Moiré fringes through the amplification characteristics of the fringes. Linear grating is for analyzing deviation of x and z. The square center symmetric grating is for analyzing deviation of x and y. We apply a low-pass filter to take out the high-frequency terms with using approach of fast Fourier transform to analyze the frequency terms of the gray value. After measuring the positions of peaks and valleys, we can calculate the practical displacement of two wafers.
The construction of a coherent scattering microscope was developed in the EUV mask inspection system and dual-axis platform. The diffraction pattern of the signal light source and the defect were measured under a light spot of 500μm, providing rapid and high-resolution mask defect detection in the future.
The construction of a coherent scattering microscope was developed in the EUV mask inspection system and dual-axis platform. The diffraction pattern of the signal light source and the defect were measured under a light spot of 500μm, providing rapid and high-resolution mask defect detection in the future.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/76940
DOI: 10.6342/NTU202002471
Fulltext Rights: 未授權
Appears in Collections:工程科學及海洋工程學系

Files in This Item:
File SizeFormat 
U0001-0508202015195700.pdf
  Restricted Access
6.33 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved