Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 醫學工程學研究所
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/46162
標題: 一個用於電腦斷層導引介入性治療的微型導航系統
A Miniature Navigation System for CT-guided Intervention
作者: Chi-Lin Yang
楊奇林
指導教授: 王兆麟
關鍵字: 手術導航,電腦輔助手術,電腦斷層,雙平面螢光攝影,影像定位,
Surgery navigation,Computer aided surgery,Computed tomography,Bi-plane fluoroscopy,Image registration,
出版年 : 2010
學位: 博士
摘要: Computed Tomography (CT)-guided intervention has become an integral component of modern patient care. However, due to the lack of real-time visualization feedback, the workflow of the CT-guided intervention involves repeated CT scans, that often lead to prolong operation time and higher radiation dose to the patient.
The objective of this dissertation is to propose a navigation system to streamline the current CT-guided intervention workflow. The goal is to develop a miniature patient-mount navigation system for spinal diseases. The miniature design is the key concept of the system to enable tracking capability without the lost of the accuracy. Another important feature is the auto-registration technique to eliminate the cumbersome registration procedure. To further improve the performance, an intuitive user interface utilizing the virtual bi-plane fluoroscopy technique is proposed. The integrated user interface allows surgeons to follow their already-mastered interventional technique without learning a new protocol.
To evaluate the feasibility of the system, three validations are conducted. The first two validations, one with physical phantom and the other with in vitro porcine model, are used to validate machine accuracy and operation error, respectively. The third validation, involving an in vivo clinical human trial, is used to validate the clinical feasibility and efficacy of the system on percutaneous pulsed radiofrequency stimulation of dorsal root ganglion (PRF-DRG). The in vivo human trial shows machine position error 4.6 mm and tilting error 3.6°, which are within the range of conventional fluoro-guided technique.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/46162
全文授權: 有償授權
顯示於系所單位:醫學工程學研究所

文件中的檔案:
檔案 大小格式 
ntu-99-1.pdf
  目前未授權公開取用
3.37 MBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved