Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 醫學院
  3. 藥學專業學院
  4. 藥學系
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/39387
Title: 藉由高效液相層析法之新一代管柱-整體式管柱分析番瀉錠劑中之番瀉葉苷A與番瀉葉苷B
The use of a new generation column of high performance liquid chromatography, monolithic column, to analyze sennoside A and sennoside B in a senna tablet
Authors: Chia-Yun Wen
溫嘉筠
Advisor: 孫紹文
Keyword: 粒子充填式管柱,整體式管柱,番瀉葉&#33527,
sennoside,monolithic column,particle-packed column,
Publication Year : 2004
Degree: 碩士
Abstract: 番瀉錠劑中最主要且含量最多的活性成分為sennoside A及sennoside B,臨床上常用來治療便秘,但服用過量會造成腸絞痛及嚴重的腹瀉,為了能在正常劑量服用下達到有效的醫療用途,確知番瀉錠劑中sennoside A及sennoside B的含量是必須的,同時為了能快速且有效的於番瀉錠劑中測定sennoside A及sennoside B的含量,本研究使用了整體式管柱(monolithic column)類型之一的ChromolithTM performance RP-18e當管柱,此管柱相較於傳統使用的粒子充填試管柱(particle-packed column)具有較低的管柱內壓,故可在高流速下進行分析以減少分離的時間。
在分析方法建立的過程中,探討緩衝溶液濃度、緩衝溶液pH值、離子對試劑的濃度、有機溶媒修飾劑體積、管柱溫度及移動相流速等影響分離的參數,最後找到一個最適化的分離條件為―管柱: ChromolithTM performance RP-18e (100
Sennoside A and sennoside B are the most significant and abundant active components in senna tablets. Clinically, they are used for constipation treatment. However, overdose will cause tormina and severe diarrhea. In order to make sure and determine the doses of sennoside A and sennoside B effectively, this study employed one of the monolithic columns, ChromolithTM performance RP-18e. Compared to the traditional particle-packed column, this one is with lower column pressure and thus it can be analyzed under high flow rate to reduce separation time.
In the course of method development, parameters including concentration and pH value of buffer solution, concentration of ion-pair reagents, volume of organic solvent modifier, column temperature and flow rate of the mobile phase were varied to find out the optimum conditions of separation. The most optimum conditions were : ChromolithTM performance RP-18e (100
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/39387
Fulltext Rights: 有償授權
Appears in Collections:藥學系

Files in This Item:
File SizeFormat 
ntu-93-1.pdf
  Restricted Access
4.12 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved