Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 應用力學研究所
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/25302
Title: 頸動脈內膜中層厚度變化之非侵入性動態測量
Noninvasive Dynamic Measurements of Carotid Intima-Media Thickness and Stiffness
Authors: Szu-Han Lee
李思翰
Advisor: 邵耀華
Keyword: 頸動脈,內膜中層厚度,超音波B-mode,機械特性,危險因子,
CCA,IMT,B-mode ultrasound,Echo tracking,Mechanical property,Risk factor,Cardiovascular events,
Publication Year : 2007
Degree: 碩士
Abstract: 頸動脈內膜中層厚度(Carotid Intima-Media Thickness, CIMT)的量測結果,在近十年來已被視為診斷心血管疾病的重要危險因子之一,並且也常被用來當作患者接受治療的療效評估指標。但是過去的量測都只關心CIMT的厚度上的變化,往往因為量測技術上的限制,無法進一步的研究頸動脈管壁本身材質的變化,只從外觀的改變來當作臨床指標,很可能會遺漏一些重要生理資訊的表現。因此本實驗的研究目的在於利用現有的臨床檢測技術上,能否改進量測與計算的定義,在可靠的力學根據下,提供更為精確的臨床診療應用。
根據橡皮管的體外實驗結果,利用超音波以及影像分析所得到的橡皮管尺寸,與實際尺寸間的誤差只有3%,而使用超音波B-mode量測頸動脈的實驗結果顯示,在把頸動脈當作完全彈性體的假設下,所得到的CIMT硬度指標,於十位平均年齡為23.6歲的年輕健康男性中, 結果與過去文獻中常使用的Peterson’s elastic modulus相比較 ,結果顯示 容易受到不同受試者間,不同的生理狀態(血壓、舒張壓時管徑)之影響,而 在考慮受試者的IMT變化情況下,比 能夠反映更多的受試者頸動脈材料性質,因此得到了較為穩定的實驗結果。
由實驗結果顯示,本實驗所提出的頸動脈硬度指標,為一個有效且能反映更多生理資訊的指標,並且利用現有的超音波儀器,只要經過後端的影像處理分析,便能克服以往在量測上的限制,在將來經過更多的實驗驗證後,以期可以降低臨床診斷以及評估治療成效的難度,並提高其準確性。
Aims Measurement of change in carotid intima-media thickness (CIMT) has been proposed as an alternative for the occurrence of cardiovascular events in the assessment of therapeutic interventions. This study attempted to use the current technique of the clinical examination to improve diagnosis not only by the evolving technology but also by the mathematical progressing.
Methods and results We assume the carotid arterial wall is the elastic material so we can use the Hooke's law to analyze it. The experiment is based on the use of ultrasound B-mode imaging technique and the off-line image analysis. Elastic tube phantom experiments demonstrated the validity of the technique, providing the size of the tube within 3% of the actual values. The system was also tested in the common carotid arteries of 10 healthy males (age 23.6 y). According to the experimental result, it shows that our index is less variant than Peterson’s elastic modulus. The results of and are and respectively.
Conclusion The new index shows the ability to reveal more physiological information and is more adaptable to be a risk factor of the cardiovascular events, but it needs more evidence to verify the observation.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/25302
Fulltext Rights: 未授權
Appears in Collections:應用力學研究所

Files in This Item:
File SizeFormat 
ntu-96-1.pdf
  Restricted Access
4.49 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved