Please use this identifier to cite or link to this item:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/23808
Title: | 建立同步監測尿液中Cotinine與8-OHdG線上固相萃 取質譜分析方法探討餐飲業人員油煙暴露與氧化傷害指標之相關性。 The study of relationship between cooking oil fume exposure and DNA oxidative stress by simultaneous analysis of urinary Cotinine and 8-Hydroxy-2’-deoxyguanosine with On-line Solid Phase Extraction Isotope-dilution and LC-MS/MS. |
Authors: | Ming-Huan Lin 林明煥 |
Advisor: | 吳焜裕 |
Keyword: | tt-DDE,8-OHdG,Cotinine,線上固相萃取,質譜儀,油煙, tt-DDE,8-OHdG,Cotinine,On-line SPE LC/MS/MS,cooking oil fume, |
Publication Year : | 2011 |
Degree: | 碩士 |
Abstract: | Lung cancer has been the first cause of death for a long time in Taiwan. Smoking is considered as the primary carcinogen, but the smoking rate of female is even lower in Taiwan. Epidemiology research shows that cooking oil fume is the significant risk factor of lung cancer.
Restaurant workers are study subjects of this research. There were 46 waiters, 59 cooks and 20 vendors recruited to join this study. Urine samples of pre-work and post-work were collected. We use tt-DDE (trans, trans-2,4-decadienal) to represent the exposure of cooking oil fume. Cooks and Vendors used personal air sampling equipment to collect the tt-DDE while they were working. We wanted to develop an LC-MS/MS analysis method for simultaneously quantification of urinary 8-OHdG and cotinine. To monitor the oxidative stress after the exposure of cooking oil fume. The simultaneously analysis method for quantification of urinary 8-OHdG and Cotinine has been established. Quantification range of cotinine is from 0.5ng/mL to 1000 ng/mL. The limit of detection (LOD) is 0.5ng/mL. Accuracy is from -0.22% to 3.76%. Precision is from 0.86% to 7.67%. The quantification range of 8-OHdG is from 0.5ng/mL to 15ng/mL. the limit of detection (LOD) is 0.5ng/mL. Accuracy is from -2.28% to 0.19%. Precision is from 1.42% to 8.24%. R2 values are larger than 0.995. Urinary 8-OHdG concentrations of cooks and vendors are higher than waiters (p-value <0.0001) and urinary 8-OHdG concentrations of post-work are higher than of pre-work. Urinary cotinine concentrations of cooks and vendors are also higher than waiters.( p-value<0.0001) |
URI: | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/23808 |
Fulltext Rights: | 未授權 |
Appears in Collections: | 職業醫學與工業衛生研究所 |
Files in This Item:
File | Size | Format | |
---|---|---|---|
ntu-100-1.pdf Restricted Access | 627.31 kB | Adobe PDF |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.