Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 公共衛生學院
  3. 職業醫學與工業衛生研究所
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/23808
標題: 建立同步監測尿液中Cotinine與8-OHdG線上固相萃 取質譜分析方法探討餐飲業人員油煙暴露與氧化傷害指標之相關性。
The study of relationship between cooking oil fume exposure and DNA oxidative stress by simultaneous analysis of urinary Cotinine and 8-Hydroxy-2’-deoxyguanosine with On-line Solid Phase Extraction Isotope-dilution and LC-MS/MS.
作者: Ming-Huan Lin
林明煥
指導教授: 吳焜裕
關鍵字: tt-DDE,8-OHdG,Cotinine,線上固相萃取,質譜儀,油煙,
tt-DDE,8-OHdG,Cotinine,On-line SPE LC/MS/MS,cooking oil fume,
出版年 : 2011
學位: 碩士
摘要: Lung cancer has been the first cause of death for a long time in Taiwan. Smoking is considered as the primary carcinogen, but the smoking rate of female is even lower in Taiwan. Epidemiology research shows that cooking oil fume is the significant risk factor of lung cancer.
Restaurant workers are study subjects of this research. There were 46 waiters, 59 cooks and 20 vendors recruited to join this study. Urine samples of pre-work and post-work were collected. We use tt-DDE (trans, trans-2,4-decadienal) to represent the exposure of cooking oil fume. Cooks and Vendors used personal air sampling equipment to collect the tt-DDE while they were working. We wanted to develop an LC-MS/MS analysis method for simultaneously quantification of urinary 8-OHdG and cotinine. To monitor the oxidative stress after the exposure of cooking oil fume.
The simultaneously analysis method for quantification of urinary 8-OHdG and Cotinine has been established. Quantification range of cotinine is from 0.5ng/mL to 1000 ng/mL. The limit of detection (LOD) is 0.5ng/mL. Accuracy is from -0.22% to 3.76%. Precision is from 0.86% to 7.67%.
The quantification range of 8-OHdG is from 0.5ng/mL to 15ng/mL. the limit of detection (LOD) is 0.5ng/mL. Accuracy is from -2.28% to 0.19%. Precision is from 1.42% to 8.24%. R2 values are larger than 0.995.
Urinary 8-OHdG concentrations of cooks and vendors are higher than waiters (p-value <0.0001) and urinary 8-OHdG concentrations of post-work are higher than of pre-work. Urinary cotinine concentrations of cooks and vendors are also higher than waiters.( p-value<0.0001)
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/23808
全文授權: 未授權
顯示於系所單位:職業醫學與工業衛生研究所

文件中的檔案:
檔案 大小格式 
ntu-100-1.pdf
  目前未授權公開取用
627.31 kBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved