請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/65196完整後設資料紀錄
| DC 欄位 | 值 | 語言 |
|---|---|---|
| dc.contributor.advisor | 陳發林(Fa-Lin Chen) | |
| dc.contributor.author | Zhu-wei Chu | en |
| dc.contributor.author | 朱梓維 | zh_TW |
| dc.date.accessioned | 2021-06-16T23:29:26Z | - |
| dc.date.available | 2015-08-01 | |
| dc.date.copyright | 2012-08-01 | |
| dc.date.issued | 2012 | |
| dc.date.submitted | 2012-07-30 | |
| dc.identifier.citation | [1] BP2010、WorldNuclearAssociation(2010)
[2] 經濟部能源局http://www.moeaboe.gov.tw [3] 永續能源政策綱領 [4] IEA(2009),Energy Balances of OECD Countries 2009 Edition. [5] 飛利浦(Philips)光源產品型錄,飛利浦2007/2008 [6] 中德技術合作”中國既有建築節能改造”項目,2010年9月 [7] 95年工商普查資料,行政院主計處 [8] 內政部營建署http://www.cpami.gov.tw/ [9] IPCC - Intergovernmental Panel on Climate Change http://www.ipcc.ch/ [10] 能源發展綱領政策評估說明書 [11] 台灣低碳電力結構分析,陳發林,2011 [12] 照明系統Q&A節能技術手冊,2008 [13] Energy Saving Measures for Taiwan’s Built Environment,2009 [14] 建築物能源管理技術研究服務計畫,林憲德,2009 [15] 2010年能源產業技術白皮書,經濟部能源局,99年4月 [16] 百貨業節能技術手冊,97年撰 [17] 量販店節能技術手冊 [18] 產業節約能源服務報告,中技社節能技術發展中心 [19] 中華徵信所-集團研究資料庫資料統計 [20] 百貨業技術手冊,89 [21] 專家診斷系統應用於建築節能之應用以百貨類建築為例,李魁鵬、張哲榮,93年 [21] 台灣地區集團便利商店自願性節約能源推動,綠基會通訊,96年1月 [22] 大專院校建築耗能特性與節能設計對策,郭柏嚴 [23] 教育部資料下載區, http://www.edu.tw/download_list.aspx [24] 學校節約能源技術手冊,經濟部能源局,2006年7月 [25] 台電高壓用電戶資料,中技社節能中心資料 [26] 行政院衛生署統計室http://www.doh.gov.tw/ [27] 衛生署99年度臺灣地區歷年公私立醫療院所數統計 [28] 醫療百貨類建築耗能總量調查之研究,內政部,89年 [29] 行政院主計處,國情統計通報(第232號) [30] 醫院節能技術手冊 [31] 交通部觀光局行政資訊系統網站,旅館分類標準及統計資料,2010 [32] 國情統計通報(第032號),行政院主計處,101年2月 [33] 旅館類建築耗能總量調查之研究,陳瑞玲、黃漢泉,2000。 [34] 2011年非生產性質行業能源查核年報,行政院,2011 [35] 高耗能辦公大樓耗能因子解析之研究,林憲德、楊開翔,2008年 [36] 政府機關辦公室節能技術手冊,經濟部 [37] 蕭弘清教授,台灣科技大學電機系,從綠色照明潮流探討照明省能新方向,2007 年7 月 [38] 建築用電密度標準之研究,林憲德、陳介慧,2009 [39] 高效率小型空調設備技術開發及應用推廣',能源研究發展基金計畫工作總報告及各技術報告,工研院能環所,97-D0232,2009年2月 [40] 高效率產業與住商冷凍技術開發,能源研究發展基金計畫98年期中報告及各技術報告,工研院能環所,97-D0249,2009年7月 | |
| dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/65196 | - |
| dc.description.abstract | 由於台灣高速的經濟成長與科技進步,使人類生活帶來便利且繁榮,但伴隨著是能源大量的消耗及自然環境的破壞。導致近年來氣候異常現象頻傳,國際間也紛紛訂定規範。為使未來產業更具競爭力,故本研究調查台灣住宅與商辦服務業全年用電情況,做一最大節能量評估並給予未來規劃建議。
本研究分四階段進行,第一階段為調查目前電力使用情形,根據台灣電力公司公開資料及非製造業能源查核網路填報資料進行比對。第二階段為制訂研究範圍與調查相關文獻探討。第三階段為調查國內外之節能技術,並以BAT (Best available technology)方法討論,設備分為照明、空調及動力(電梯、馬達)等探討。第四階段為根據前三項所蒐集之資料進行評估分析,並對未來提出建議方案。 經過調查評估,住宅部分使用市面上一般節能家電及美國能源之星設備計算,使用現行設備最大節能比為19.77%,節能量達85.73億度電。使用美國能源之星節能家電置換,照明以LED估算,最大節能比為40.76%,節能量達177.01億度電。服務業部分使用省電燈泡及T5燈管置換現行照明設備,其他設備以市面節能設備估算,其節能比為21.62%,其節能量達72.36億度電。若使用能源之星調查設備進行估算,其節能潛力達38.98%,其節能量達130.49億度電。 | zh_TW |
| dc.description.abstract | Rapid economic growth and technology progress bring not only convenience but prosperity into human life; however, great consumption of energy resources and serious devastation of natural environment also come after. To ensure the competitiveness of future industry, this research investigates the annual electricity consumption of residential and commercial services, and estimates the greatest amount of energy-saving, and then gives suggestions to future plans
This research was conducted in four phase. First, to investigate current power usage, we compared the public information and Energy audit of non-manufacturing data provided by Taiwan Power Company. Second, we set up the scope of this research and did literature review. And then, this research uses BAT (Best available technology) method to survey national energy-related equipment, included lighting equipment, air conditioning and power (elevators, motors and others). In the final phase, this research analyzes the data achieved in the first three phases, and makes recommendations for future plans and recommendations. After investigating and evaluating, this research has discovered that using general energy-saving appliances, the largest energy-saving ratio of the residential services was 19.77%, energy-saving amounted to 8.5 billion kWh. On the other hands, using U.S. Energy Star energy-saving appliances, and LED for lighting, the maximum energy saving is 40.76%, energy saving amounted to 17.7 billion kWh. In the case of commercial services, we used energy-saving bulbs and T5 lamp to replace the lighting, and other equipments were calculated as ordinary equipments in the market. The results show that the energy-saving ratio is 21.62%, and the energy-saving amounted to 7.2 billion kWh. Services part, lighting use the energy saving bulbs and T5 lamp replace existing lighting and other equipment use market equipment.Calculation results energy saving ratio of 38.98%, energy-saving amounted to 1.34billion kWh. | en |
| dc.description.provenance | Made available in DSpace on 2021-06-16T23:29:26Z (GMT). No. of bitstreams: 1 ntu-101-R99543094-1.pdf: 2402838 bytes, checksum: 06035a4d680130b39c0f77697f71a423 (MD5) Previous issue date: 2012 | en |
| dc.description.tableofcontents | 摘要 i
Abstract ii 目錄 iv 圖目錄 vii 表目錄 viii 第一章 緒論 1 1.1 前言 1 1.2 研究動機 3 1.3研究方法 6 1.4文獻回顧 10 1.4.1空調熱負荷 12 1.4.2照明負載 12 1.4.3外觀節能 13 1.4.4用電現況調查 13 第二章 住宅 14 2.1 住宅現況統計 14 2.2 住宅耗能項目 18 2.2.1螢光燈管 21 2.2.2空調技術 21 2.2.3電視機 22 2.2.4洗衣機 22 2.3住宅節能項目技術內容 25 2.4住宅節能潛力分析 27 2.4.4住宅節能方案A 27 2.4.2美國能源之星方案 29 第三章 商辦服務業 32 3.1商辦服務業現況 32 3.2商辦服務業耗能統計 35 3.2.1批發零售業 35 3.2.2教育服務業 56 3.2.3醫院類 59 3.2.4飯店、旅館 68 3.2.5綜合辦公大樓 75 3.2.6通信業者 78 3.2.7運輸倉儲業 81 3.2.8娛樂服務業 83 3.3商辦節能項目技術內容 87 3.3.1空調節能技術 87 3.3.2照明技術 88 3.3.3冷凍冷藏技術 89 3.3.4 電梯設備 89 3.4商辦節能潛力分析 90 3.4.1商辦方按A 91 3.4.2商辦方案B 92 3.4.3商辦方案C 93 第四章 結果與討論 95 4.1 結論 95 4.2 未來展望 97 參考文獻 98 | |
| dc.language.iso | zh-TW | |
| dc.subject | 能源之星 | zh_TW |
| dc.subject | 節能策略 | zh_TW |
| dc.subject | BAT | zh_TW |
| dc.subject | 節能 | zh_TW |
| dc.subject | energy saving | en |
| dc.subject | BAT | en |
| dc.subject | Energy Star | en |
| dc.subject | Energy-saving Strategy | en |
| dc.title | 台灣住宅與商辦節能量統計 | zh_TW |
| dc.title | The Analysis of Residential and Commercial Energy-saving in Taiwan | en |
| dc.type | Thesis | |
| dc.date.schoolyear | 100-2 | |
| dc.description.degree | 碩士 | |
| dc.contributor.oralexamcommittee | 左峻德(Jiun-De Tzuo),陳朝光(Chao-Kuang Chen),席時昶(Shr-Chang Shi),陳誠亮(Cheng-Liang Chen) | |
| dc.subject.keyword | 節能,BAT,能源之星,節能策略, | zh_TW |
| dc.subject.keyword | energy saving,BAT,Energy Star,Energy-saving Strategy, | en |
| dc.relation.page | 100 | |
| dc.rights.note | 有償授權 | |
| dc.date.accepted | 2012-07-31 | |
| dc.contributor.author-college | 工學院 | zh_TW |
| dc.contributor.author-dept | 應用力學研究所 | zh_TW |
| 顯示於系所單位: | 應用力學研究所 | |
文件中的檔案:
| 檔案 | 大小 | 格式 | |
|---|---|---|---|
| ntu-101-1.pdf 未授權公開取用 | 2.35 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。