Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 生物資源暨農學院
  3. 農藝學系
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/63268
標題: 成對部分ROC曲線下面積差之非劣性檢定
A non-inferiority test for diagnostic accuracy in the absent of a gold standard test based on the paired partial areas under ROC curves
作者: Shu-Man Shih
石舒嫚
指導教授: 蘇秀媛(Hsiu-Yuan Su)
關鍵字: 部分ROC曲線下面積,EM演算法,拔靴法,黃金診斷標準,最大概似估計,疾病狀況缺失,
partial area under the ROC curve,EM algorithm,bootstrap method,gold standard test,maximum likelihood estimation,missing disease status,
出版年 : 2012
學位: 碩士
摘要: 在診斷試驗中,比較新診斷工具與舊(標準)診斷工具的準確性是一項重要的課題。當新的診斷工具其準確性不比舊的診斷工具差,
同時使用上更為安全、相關費用較為經濟亦或是較少侵入性等。這類型的臨床試驗稱之為非劣性試驗 (non-inferiority test)。
接受者操作特徵曲線(receiver operating characteristic curve)簡稱ROC曲線,是用來評估診斷工具準確性的統計方法。ROC
曲線下面積(AUROC)則是用來評估診斷性的方法之一。當考慮兩個診斷工具時,在相同的AUROC之下,可能有部分的區域是具有臨床相關性,但容易被忽略。
而ROC曲線下部分面積(PAUROC)則是更能全面性的評估其精確性,並克服AUROC面臨的難題。

當黃金標準試驗(gold standard test; GS)存在時,一般常以ROC曲線下部分面積(PAUROC)作為評估兩個診斷工具準確性的指標。
然而在某些情況下,黃金標準試驗容易因執行費用太昂貴或是不易取得而不存在(no-gold standard test; NGS)。
本篇論文討論在常態性假設之下,利用EM演算法及拔靴法(bootstrap method),提出以最大概似法為基礎(maximum likelihood based method; ML-based method)的統計程序,
討論當黃金標準不存在(NGS),針對成對部分ROC曲線(PAUROC)下面積的非劣性檢定。
經由模擬研究可驗證,當黃金標準試驗不存在時, ML-based方法足以將Emipirical size控制在0.05左右,同時針對新診斷方法的非劣性檢定也提供的充分的檢定力。
最後利用提出之方法針對胰臟癌(Pancreatic cancer)的實際診斷資料進行分析。
The non-inferiority test is an approach to assess the accuracy of a new diagnostic test if it reduces the cost.
Receiver operating characteristic (ROC) curves can be used to assess the accuracy of tests measured on ordinal or continuous scales.
The area under ROC curve (AUROC) is widely applied in many kinds of field and is used as a tool to decide the accuracy of diagnositic tests.
However, it may not differentiate the various shapes of the ROC curves with different diagnostic significances.
The partial area under ROC curve (PAUROC) is an attractive alternative that can provide additional and complimentary information for some
diagnostic procedures which require the false-positive rate (FPR) to be within a range of clinical interest.
A gold standard (GS) test on the true disease status is required to estimate the PAUROC.
However, a GS test may be too expensive or infeasible. In many medical researches, the true disease status of the subjects may remain unknown.
Under the normality assumption on test results from each disease group of subjects, we propose the maximum likelihood-based (ML-based) method
to construct a non-inferiority test for diagnostic accuracy based on the difference in paired PAUROCs in the absence of a GS test (NGS).
Simulation results shows that the proposed method for non-inferiority under the NGS case controls the size at the nominal level,
and the performance in empirical power is similar to GS case. The proposed method is illustrated with an example.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/63268
全文授權: 有償授權
顯示於系所單位:農藝學系

文件中的檔案:
檔案 大小格式 
ntu-101-1.pdf
  目前未授權公開取用
522.72 kBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved