標題: 以微電極陣列對細胞阻抗之量測分析
Measuring Cell Impedance by Microelectrode Array
作者: Yu-Chung Chen
陳昱中
指導教授: 林啟萬
關鍵字: 微電極陣列,細胞阻抗,
Microelectrode Array,Cell Impedance,
出版年 : 2010
學位: 碩士
摘要: Microelectrode array (MEA) has been used in cell physiology for many years. It features the non-invasive, long-term, and space resolution method to record cell signals. By applying MEA, the neuron extracellular voltage could be record and the electrophysiology could be further researched.
Cell impedance is another method to evaluate the condition of the cell culture. Previous researches showed that the cell attachment and spread on the electrode could be detected by the change of the impedance. Thus the impedance could be a method to evaluate the condition of the cell growth, proliferation or apoptosis.
In this research, microelectrode array has been fabricated by photolithography process. Indium-Tin Oxide (ITO) was chosen as the conducting material for its conductivity and transparency, and was regarded to be non-toxicity for cell culture. The ITO pattern was covered with Silicon-dioxide (SiO2) insulating layer. A large reference electrode was made by Silver/Silver Chloride (Ag/AgCl) on top of the SiO2 layer.
Human kidney epithelial cells were cultured on the surface of the MEA. Impedance of the cells was measured from 1 kHz to 100 kHz. High impedance could be measured if the cells attached to the surface in good condition. While the cells grow quite well on the SiO2 covered surface, the AgCl surface had an inhibitive effect on cell attachment and proliferation. Also the measuring process involved input high frequency voltage wave, which might had deteriorated effect on the attached cells.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/45981
全文授權: 有償授權
顯示於系所單位:醫學工程學研究所

文件中的檔案:
檔案 大小格式 
ntu-99-1.pdf
  未授權公開取用
11.02 MBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved