Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 化學工程學系
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/45022
Title: 化學修飾電極及分子模版修飾電極在電化學式生物感測器之應用
Chemically Modified Electrodes and Molecularly Imprinted Polymer Electrodes for Electrochemical Biosensors
Authors: Po-Yen Chen
陳柏延
Advisor: 何國川
Keyword: 化學修飾電極,媒子,分子模版,自我組裝,感測器,
Chemically modified electrode,Mediator,Molecularly imprinted polymer,Self-assembly monolayer,Sensor,
Publication Year : 2010
Degree: 博士
Abstract: 本論文主要探討化學修飾電極及分子模版修飾電極在電化學生物感測器之應用。所研究的電化學生物感測器是利用媒子(mediators)以及分子模版(MIPs)對電極進行修飾。在研究的初期,首先使用一個新型的導電高分子-poly(PD-BCD)製備分子模版電極,並將此電極應用在尿酸(uric acid)的感測上,研究結果發現:改變高分子含量達到0.6 wt%時電極具有最佳的模版效率(3.73),此時分子模版以及非分子模版的靈敏度分別為24.72以及 6.63 μA/mM cm2。此感測器的偵測下限可達到0.3
This dissertation deals with chemically modified electrodes and molecularly imprinted polymer (MIP) electrodes for electrochemical biosensors. The electrochemical biosensors were based on modifying mediators and MIP. Initially, a novel amine-imide type conducting polymer, denoted as poly(PD-BCD), was molecularly imprinted with uric acid (UA). The results revealed that the imprinting efficiency (IE) was highly associated with the polymer content. It was found that the optimum polymer content at 0.6 wt% gives the highest imprinting efficiency of 3.73. The sensitivities of the MIP and the non-MIP (NMIP) electrodes made with 0.6 wt% of polymer were calculated to be 24.72 and 6.63 μA/ mM cm2, respectively. The limit of detection (LOD) for the MIP electrode was found to be 0.3 μM. This MIP electrode was used as a biosensor for the detection of UA in the presence of ascorbic acid (AA) in a sample containing these species in the same concentrations as those in a human serum. Only 7% increase in current was noticed when sensing the mixed sample, as compared to the UA sample alone. In further research, a non-conducting polymer, poly-methacrylic acid (PMAA) was polymerized on the surface of multi-walled carbon nanotubes (MWCNTs) for sensing UA. The adsorption isotherms suggest that a good IE of 4.41 for UA. The adsorption isotherms were correlated successfully by the Freundlich model. Amperometric detection also revealed similar aspect, as compared to the adsorption data, and showed high selectivity toward AA, with an IE value of 2.05. For the extension of non-conducting polymers, a novel MIP electrode was fabricated by using a mediator as the reactive center and a MIP layer as the recognition part. Because of this new system, reactive mediators were investigated subsequently.
It was found that quercetin (Q), an ideal mediator, possesses catalytic effect to the neurotransmitter which was named dopamine (DA). Glassy carbon (GC) electrode was modified using MWCNTs, quercetin and Nafion® in this sequence. A possible reaction mechanism between Q and DA was proposed. The amperometric detection potential was fixed at 0.45 V (vs. Ag/AgCl sat’d KCl) as determined by the linear sweep voltammetry (LSV). The GC/MWCNTs/Q/Nafion® electrode shows a current density of about 900 µA cm-2 for DA, comparing to that of 80 µA cm-2 for the GC electrode. The 11-fold sensitivity enhancement for the modified GC electrode in sensing DA is attributed to the composite modification of the electrode. The composite electrode does eliminate the interference against AA. Calibration curves of batch and flow systems were obtained by amperometry for the detection of DA. Moreover, another mediator, flavin adenine dinucleotide (FAD), which plays a role of reducing agent for hydrogen peroxide (H2O2), was found. FAD was immobilized on a poly(3,4-ethylenedioxy-thiophene) (PEDOT) conducting polymer-modified GC electrode and was proposed to detect H2O2. The amperometric detection potential was fixed at -0.40 V (vs. Ag/AgCl sat’d KCl) as determined by the LSV. The sensitivity and the LOD for the GC/PEDOT-FAD electrode were 92.3 mA/M cm2 and 143
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/45022
Fulltext Rights: 有償授權
Appears in Collections:化學工程學系

Files in This Item:
File SizeFormat 
ntu-99-1.pdf
  Restricted Access
3.68 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved