Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 機械工程學系
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/74944
Title: 具微針結構電容式流量感測器應用於器官晶片微流道系統
Development of a Capacitive Flow Rate Sensor with Microstructured Dielectric for Microfluidic Organ-On-Chip System
Authors: Chuang Yin Wang
王傳印
Advisor: 楊燿州
Keyword: 流量,器官晶片,浮動電極,電容式壓力感測器,微結構,
Flow rate,organ-on-chip,floating electrode,capacitive pressure sensor,microstructure,
Publication Year : 2019
Degree: 碩士
Abstract: 本研究開發高靈敏度的微型壓力感測器,並將其整合於器官晶片微流道系統以應用於非侵入式且即時量測微流道的流量變化。感測器包含上方浮動式電極與下方電極對,中間之介電層則是採用聚二甲基矽氧烷(Polydimethylsiloxane, PDMS)之微結構薄膜。浮動式電極的設計可以有效減少電容感測器接線上的困難度,使感測器更容易整合於微流道系統。加入PDMS微結構薄膜可以使電容感測器擁有高靈敏度、廣大的量測區間、更線性的電容變化程度與降低遲滯現象等優勢。此外,本研究亦利用Ansys Fluent商用軟體進行流體模擬,分析微流道之流體在層流情況下之運動狀態。因為微流道內流量的改變會造成流道腔體內壓力的變化,因此可以藉由偵測流道內壓力的變化來預估流量。此微流道流量感測器在0~900μl/min的流量範圍內擁有良好的且線性的電容變化。同時在浮動電極結構厚度為100μm時,微流道流量感測器有最佳的靈敏度0.0207%.min/μL。
This work presents the design and fabrication of a highly-sensitive miniaturized pressure sensor that can be integrated with an organ-on-chip system for nonintrusive and rapid monitoring of flow rate in microfluidic channels. The proposed device employs a variable capacitor for pressure sensing. The capacitor consists of a sensing electrode pair, a common floating electrode, and a microstructured PDMS dielectric layer sandwiched between the electrodes. The design with the floating electrode can effectively reduce the complexity of the device interconnects for retrieving signals. The microstructured thin film gives advantages such as wide sensing range, low hysteresis, and good linearity. Three dimensional Navier–Stokes simulations is carried out by a Finite Volume Method (FVM) solver in a laminar flow condition in order to investigate the behavior of the fluid in the channel. The pressure in the microfluidic channel can deform the PDMS membrane on the top of the floating electrode, which in turn changes the gap of the capacitance and thus changes the capacitance. Therefore, the pressure change can be detected by measuring the capacitance change. The sensor has the linear response in the range of 0~900μl/min for the optimal sensor performance. The highest sensitivity is about 0.0207%.min/μL for the membrane with a thickness of 100μm.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/74944
DOI: 10.6342/NTU201902643
Fulltext Rights: 有償授權
Appears in Collections:機械工程學系

Files in This Item:
File SizeFormat 
ntu-108-1.pdf
  Restricted Access
24.49 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved