Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 公共衛生學院
  3. 公共衛生碩士學位學程
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/71202
Title: 一個新型遠紅外線體溫監測預警系統的產品開發經驗
THE EXPERIENCE OF DEVELOPING OF AN INNOVATIVE NON-CONTACT REAL-TIME INFRARED THERMOGRAPHY SYSTEM
Authors: TUNG-CHUN CHAN
詹東峻
Advisor: 楊銘欽(MING-CHIN YANG)
Co-Advisor: 湯相峰(HSIANG-FENG TANG)
Keyword: 紅外線,體溫,發燒,預防醫學,熱成像,
Infrared,Body Temperature,Fever,Preventive Medicine,Thermography,
Publication Year : 2018
Degree: 碩士
Abstract: 本論文提供一種新型遠紅外線體溫監測預警系統的產品開發經驗。藉由發燒個體偵測系統與方法,以偵測一區域內發燒的個體。此系統包括相連接之感測模組與處理模組。感測模組持續地產生此區域的熱影像、將熱影像劃分為多個網格影像,並判斷是否存在溫度超過門檻溫度的網格影像,最後根據超過門檻溫度的網格影像判斷出目標熱影像。處理模組產生目標熱影像之溫度對時間的關係圖,並據此判斷目標熱影像的溫度是否隨時間上升,且若是,則根據目標熱影像的溫度與目標熱影像中每個網格影像的座標發出警示訊息,以回報發燒之個體於此區域內的位置及其體溫。
Disclosed are a system and a method for monitoring a patient with fever in an area. The system includes a detection module and a process module. The detection module continually generates a thermal image of this area, divides the thermal image into a plurality of mesh images, determines whether there is a mesh image showing a temperature over a threshold temperature, and determines a target thermal image according to the mesh images showing a temperature over the threshold temperature. After that, the process module generates a diagram showing the temperature variation of the mesh images of the target thermal image with time, and accordingly determines whether the temperature of the target image increases with time. If yes, the process module sends an alarming message according to the temperature of the target thermal image and coordinates of each mesh image of the target thermal image, to report where the patient with fever is in this area and his body temperature.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/71202
DOI: 10.6342/NTU201801941
Fulltext Rights: 有償授權
Appears in Collections:公共衛生碩士學位學程

Files in This Item:
File SizeFormat 
ntu-107-1.pdf
  Restricted Access
16.59 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved