Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 應用力學研究所
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/68622
Title: 以靜電紡絲研製高排列性壓電薄膜壓力感測器及其指叉式電極之最佳化研究及開發
Development of a piezoelectric pressure sensor based on highly aligned electrospun fibers and the optimization of Interdigitated Electrodes
Authors: Jun-Yi Ke
柯君逸
Advisor: 李世光
Co-Advisor: 許聿翔
Keyword: 聚(偏氟乙烯-三氟乙烯),靜電紡絲,可撓式感測器,壓電材料,血壓量測,
P(VDF-TrFE),electrospinning,flexible sensor,piezoelectric material,blood pressure measurement,
Publication Year : 2017
Degree: 碩士
Abstract: 本論文旨在開發高靈敏度之可撓式壓電薄膜感測器,以應用在穿戴式血壓計。為了達到高靈敏度且具可撓性,選用聚(偏氟乙烯-三氟乙烯)(polyvinylidene fluoride/trifluoroethylene, P(VDF-TrFE))高分子壓電材料,並使用滾筒式靜電紡絲製程,製作出具排列性的絲線壓電薄膜,可做為具有可撓性和感測能力的壓力感測器。然而,因為薄膜厚度與絲線間具有孔隙,使用夾層式電極容易短路,因此採用指叉式電極設計,並對不同指叉間距電極之感測薄膜作彎曲訊號測試,另外,本研究亦探討絲線排列方向與指叉方向對靈敏度影響。而為了提升訊號靈敏度,利用X光繞射儀量測薄膜晶相,證明經最佳化退火和電暈極化製程所得薄膜具有較佳之β相晶相,達成壓電性質之製程之最佳化開發。並利用高壓交流電設備量測電滯曲線,證明退火後之薄膜鐵電性質有顯著提升。最後,所得最佳化的指叉設計,量測其彎曲訊號靈敏度15.21 nA/g,所能測定之最小重量為0.1 g,並驗證在2 mm指叉間距時訊號由靜電效應主導,而0.5 mm指叉間距時訊號由壓電效應主導。本研究並應用所開發的絲線壓電薄膜壓力感應器量測到頸動脈之血壓訊號。
The goal of this thesis is to develop a highly sensitive and flexible piezoelectric pressure sensor for the application of wearable blood pressure. To create a high sensitivity and flexibility piezoelectric pressure sensor, the polymer-based piezoelectric P(VDF-TrFE) was chosen in this study. Electrospinning process was applied to electrospun P(VDF-TrFE) into an ultra-flexible thin-film like structure. Using electrospinning process with a rotating drum collector, fibers with different levels of alignment are created and studied. In order to enhance the sensitivity and prevent shortage between electrodes, inter-digitated electrodes (IDEs) were developed. Design parameters include gaps distance between electrodes, and orientations between IDEs and the direction of fiber alignments. Furthermore, the β crystal phase of P(VDF-TrFE) is optimized by studying its X-ray Diffraction (XRD) patterns under the conditions of annealing and corona discharge poling processes. It was found that the β phase can be enhanced and the sensitivity can be much improved by 1.92 ~ 5.84 times. Measurements of P-E curves are also conducted to verified the experimental findings. The maximum sensitivity was 15.21 nA/g by using bending test, and the lightest weight that can be measured is 0.1 g. Finally, it is verified that the developed thin-film piezoelectric pressure sensor can be used to measure the blood pressure signal on the skin near the carotid artery.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/68622
DOI: 10.6342/NTU201703757
Fulltext Rights: 有償授權
Appears in Collections:應用力學研究所

Files in This Item:
File SizeFormat 
ntu-106-1.pdf
  Restricted Access
6.49 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved