請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/5860
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 林文澧(Win-Li Lin) | |
dc.contributor.author | Guan-Ming Chen | en |
dc.contributor.author | 陳冠銘 | zh_TW |
dc.date.accessioned | 2021-05-16T16:17:52Z | - |
dc.date.available | 2015-08-25 | |
dc.date.available | 2021-05-16T16:17:52Z | - |
dc.date.copyright | 2013-08-25 | |
dc.date.issued | 2013 | |
dc.date.submitted | 2013-08-16 | |
dc.identifier.citation | 1. Brenin, D.R., Focused ultrasound ablation for the treatment of breast cancer. Ann Surg Oncol, 2011. 18(11): p. 3088-94.
2. Sapareto, S.A. and W.C. Dewey, Thermal dose determination in cancer therapy. Int J Radiat Oncol Biol Phys, 1984. 10(6): p. 787-800. 3. Kim, Y.S., et al., High-intensity focused ultrasound therapy: an overview for radiologists. Korean J Radiol, 2008. 9(4): p. 291-302. 4. Hynynen, K., MRI-guided focused ultrasound treatments. Ultrasonics, 2010. 50(2): p. 221-9. 5. Hynynen, K., et al., MR imaging-guided focused ultrasound surgery of fibroadenomas in the breast: a feasibility study. Radiology, 2001. 219(1): p. 176-85. 6. M. Malinen, T.H., K. Hynynen, and J.P. Kaipio, Simulation study for thermal dose optimization in ultrasound surgery of the breast. Med Phys, 2004. 31: p. 1296-1307. 7. Bakker, J.F., et al., An ultrasound cylindrical phased array for deep heating in the breast: theoretical design using heterogeneous models. Phys Med Biol, 2009. 54(10): p. 3201-15. 8. Ho, C.S., et al., Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: a preliminary numerical study. Phys Med Biol, 2007. 52(15): p. 4585-99. 9. 馮若, 超聲診斷設備原理與設計. 1993年4月: 中國醫葯科技出版社. 10. Klicker, K.A., J.V. Biggers, and R.E. Newnham, Composites of PZT and Epoxy for Hydrostatic Transducer Applications. Journal of the American Ceramic Society, 1981. 64(1): p. 5-9. 11. 劉信志, 1-3壓電複合材料應用於高強度聚焦超音波換能器之研究, in 機械工程學系碩士班. 2011, 中華大學: 新竹市. 12. Savakus, H.P., K.A. Klicker, and R.E. Newnham, PZT-epoxy piezoelectric transducers: A simplified fabrication procedure. Materials Research Bulletin, 1981. 16(6): p. 677-680. 13. Clipsham, T.J. and T.W. Button, 1-3 Piezocomposites realised from small feature size, high aspect ratio, hot embossed moulds. Part II: piezocomposite fabrication. Microsystem Technologies, 2010. 16(11): p. 1983-1988. 14. Chen, G.S., et al., Experimental analysis of 1-3 piezocomposites for high-intensity focused ultrasound transducer applications. IEEE Trans Biomed Eng, 2013. 60(1): p. 128-34. 15. 吳朗, 電子陶瓷-壓電陶瓷. 民國83年12月2號: 全欣資訊圖書股份有限公司. 16. 林伯憲, 環形相位陣列聚焦式超音波結合磁振造影系統應用於乳房腫瘤治療的研究, in 醫學工程學研究所. 2011, 臺灣大學: 台北市. 17. 謝岳成, 壓電電荷常數d33特性之量測, in 電子工程系. 2004, 國立交通大學: 新竹市. 18. Duck FA, B.A., Starritt HC, Ultrasound in Medicine. 1998: Institute of Physics Publishing. 19. 蕭義正, 溫度感應型水膠應用於聚焦型超音波熱治療之研究. 大同大學 機械工程研究所 碩士論文, 2007. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/5860 | - |
dc.description.abstract | 高強度聚焦性超音波(High-Intensity Focused Ultrasound, HIFU)是利用聲波傳遞的特性達到非侵入式治療腫瘤的效果。本研究針對乳房腫瘤開發了一套高頻高強度聚焦性環形超音波換能器,期望能針對頂部的乳房腫瘤產生聚焦效果,而對底部的乳房腫瘤能施以熱治療。
在HIFU換能器的材料選擇方面,使用的是複合壓電陶瓷,其具有降低聲阻抗且提高機電耦合係數的優點;換能器的尺寸為半徑100mm、聚焦半徑100mm、高25mm、工作頻率為2.5MHz,且將其環形超音波換能器分成16個單元。換能器的特性方面,對其量測壓電係數d33、聲阻抗以及電聲轉換效率,來驗證換能器的輸出效率以及穩定性。 目前所開發的高頻超音波環形換能器無法有效將電功率轉換成聲功率,不能達到HIFU等級的加熱效果,但仍能對組織加溫。另外在仿體實驗結果證實此環形超音波換能器能將能量集中在直徑6 cm的水膠之中心位置。 | zh_TW |
dc.description.abstract | High Intensity Focused Ultrasound (HIFU) can achieve a non-invasive treatment using sound wave transmission to heat the desired region. In this study, we tried to develop a ring-shaped HIFU transducer for breast tumors to generate thermal lesions in the tip region of the breast and to execute thermal therapy in the bottom of the breast.
Using piezocomposite material for ultrasonic transducer can lower the acoustic impedance as well as increase the electro-mechanical coupling factor. The size of transducer is 100 mm in radius, 100 mm in radius of curvature, 25 mm in height and 2.5 MHz in working frequency. The transducer consists of 16 elements. To verify the output efficiency and stability, we measured the piezoelectric parameter d33, acoustic impedance and electro-acoustic efficiency. At the present, the high frequency ring-shaped ultrasound transducer cannot reach the requirements for a HIFU, while it can heat fresh pork tissues. This ultrasound transducer can transmit the acoustic power to the center of a 6 cm gelatin phantom to effectively raise the temperature. | en |
dc.description.provenance | Made available in DSpace on 2021-05-16T16:17:52Z (GMT). No. of bitstreams: 1 ntu-102-R00548044-1.pdf: 2181846 bytes, checksum: 0008ca6712fd2fcdc28d6c0964fc79ce (MD5) Previous issue date: 2013 | en |
dc.description.tableofcontents | 致謝 i
摘要 ii Abstract iii 目錄 iv 圖目錄 vii 表目錄 x 第1章 緒論 1 1.1 乳癌 1 1.2 熱治療的發展 3 1.3 磁振導引之高強度聚焦性超音波 3 1.4 研究目的 4 第2章 材料與方法 5 2.1 壓電效應 5 2.1.1 壓電材料 7 2.1.2 1-3複合壓電材料 7 2.1.3 壓電材料統御方程式 9 2.1.4 壓電材料特性參數 11 2.2 超音波換能器 13 第3章 磁振造影相容之換能器製備及特性量測方法 14 3.1 磁振造影相容之超音波換能器 14 3.2 換能器設計 15 3.3 換能器的材料及其製備 15 3.3.1 挑選特性相同的壓電陶瓷 16 3.3.2 製作成複合材料 17 3.3.3 工作頻率之選擇 17 3.3.4 熱壓成型 18 3.3.5 沉積導電層 19 3.3.6 封裝成換能器 21 3.4 阻抗匹配電路 22 3.4.1 LC電路阻抗匹配 24 3.5 換能器特性化量測 24 3.5.1 壓電應變常數d33量測 24 3.5.2 複合壓電陶瓷之聲阻抗 25 3.5.3 電聲轉換效率 26 3.6 換能器加熱效果實驗 27 3.6.1 組織仿體實驗 27 3.6.2 離體動物實驗 29 第4章 結果與討論 31 4.1 換能器製作 31 4.1.1 磁振造影相容之超音波換能器 31 4.1.2 壓電陶瓷挑選 32 4.1.3 複合材料晶相圖 33 4.1.4 複合壓電陶瓷厚度 33 4.1.5 環形換能器機構 36 4.1.6 阻抗匹配電路 37 4.2 換能器特性量測 39 4.2.1 複合壓電陶瓷的壓電應變係數d33量測 39 4.2.2 聲阻抗量測 40 4.2.3 電聲轉換效率量測 41 4.3 換能器加熱實驗結果 49 4.3.1 組織仿體實驗 50 4.3.2 離體動物實驗 52 第5章 結論與未來展望 54 參考文獻 55 | |
dc.language.iso | zh-TW | |
dc.title | 研發應用於磁振造影導引乳房腫瘤熱治療之高頻超音波環形陣列探頭 | zh_TW |
dc.title | Development and Investigation of High Frequency MR-guided Ring-Shaped Phased-Array Ultrasound Transducer for Breast Tumor Thermal Therapy | en |
dc.type | Thesis | |
dc.date.schoolyear | 101-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 陳景欣,陳永耀 | |
dc.subject.keyword | 環形高頻超音波換能器,熱治療,乳房腫瘤,複合壓電材料,陣列式探頭, | zh_TW |
dc.subject.keyword | ring-shaped phased-array ultrasound transducer,hyperthermia,breast tumors,piezocomposite material,HIFU, | en |
dc.relation.page | 56 | |
dc.rights.note | 同意授權(全球公開) | |
dc.date.accepted | 2013-08-16 | |
dc.contributor.author-college | 工學院 | zh_TW |
dc.contributor.author-dept | 醫學工程學研究所 | zh_TW |
顯示於系所單位: | 醫學工程學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-102-1.pdf | 2.13 MB | Adobe PDF | 檢視/開啟 |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。