Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
    • 指導教授
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 理學院
  3. 物理學系
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/48147
標題: 在屏蔽磁場下使用紅外線加熱的鉀原子測磁計
Shielded Potassium Atomic Magnetometer with Infrared Heating
作者: Ying-Chen Lin
林盈甄
指導教授: 石明豐
關鍵字: 原子測磁計,紅外線加熱,拉馬旋進,磁光效應,不受自旋交換衰弛影響,
Atomic magnetometer,Spin-Exchange Relaxation Free,Larmor precession,Magneto-optical effect,Infrared heating,
出版年 : 2011
學位: 碩士
摘要: 理論上,鹼金屬原子測磁計的高敏感度可和現今最敏感測磁計的超導量子干涉磁量儀(Superconducting Quantum Interference Device)媲美。在本實驗中,利用溫度約 的高密度鉀原子氣體,在外圍以μ合金(mu-metal)圍住使其可以在微小磁場下進行作用,再將原子共振態的半導體雷射光照射在原子上,使得原子在磁場下和光產生了非線性的磁光效應,接著利用量測原子自旋角動量的拉馬旋進(Larmor Precession),我們就可以得知磁場大小。在高原子密度和微小磁場下,原子和原子之間碰撞所產生的自旋角動量互相交換且衰減的情況並不明顯,所以稱為不受自旋交換衰弛影響(Spin-Exchange Relaxation Free)的鉀原子測磁計。
在這套系統,為了改善以熱空氣加熱使得荷姆霍茲線圈和 合金會過熱的情形,我們改善了加熱系統,利用375W紅外線燈泡為熱源,以石英棒為熱源傳輸,成功將原子氣體加熱到160±10℃左右,而且荷姆霍茲線圈和 合金保持在室溫狀態。此外,我們設計新的方法來找零點磁場,進而得到幾十個 頻寬的共振分佈曲線,但是此訊號並不穩定,接著我們做了一連串的測試排除各種原因和對此系統做分析。
Theoretically, Alkali-metal magnetometers can be accurate as SQUID which is currently the most sensitive magnetic field sensors. We use high density Potassium atom vapor as our measurement sample, which is heated to 160±10℃, and is shielded by mu-metal for near zero magnetic field operation condition to reduce the noise from the spin exchange collision. The principle of the magnetometer is based on the resonant nonlinear magneto-optical effect that Larmor precession can be used to measure the spins of polarized atoms under the influence of the magnetic field.
In order to eliminate the overheating problem of the Helmholtz Coils and mu-metal caused by the hot-air heating method, we use an infrared light bulb as a thermal source and a quartz bar to transfer the heat to the Potassium cell. The temperature of the cell has been successfully raised up to 160±10℃ with no overheating problem and the system is more stable. Furthermore, a new method of finding zero magnetic fields is presented, in which the resonant signal with around 10μG width is observed. However, the signal drifts over time. To solve this problem, we have assumed some causes and target to solve them one by one.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/48147
全文授權: 有償授權
顯示於系所單位:物理學系

文件中的檔案:
檔案 大小格式 
ntu-100-1.pdf
  未授權公開取用
2.18 MBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved