Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 電機資訊學院
  3. 資訊工程學系
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/47756
Title: 動態乳房彈性超音波之腫瘤診斷
Tumor Diagnosis of Dynamic Breast Elastography
Authors: Jen-Wei Kuo
郭任瑋
Advisor: 張瑞峰
Keyword: 彈性超音波,乳房,腫瘤,信號雜訊比,對比雜訊比,
sonoelastography,breast,tumor,SNRe,CNRe,
Publication Year : 2010
Degree: 碩士
Abstract: 乳癌一直是全球婦女的主要死因之一。近年來,乳房彈性超音波已被使用來測量腫瘤彈性,醫生需要對腫瘤組織施與輕微的壓力以便取得一段動態彈性視訊,藉由腫瘤組織的位移得到軟硬資訊,最後,醫生將會從視訊中選出一張代表性的影像來協助腫瘤的診斷。此篇論文的目的為使用影像量化的方法來自動地選出最具代表性的一張影像,並且自動切割出腫瘤輪廓來擷取特徵診斷腫瘤。首先,根據腫瘤內部的一致性(信號雜訊比,SNRe)以及腫瘤與周圍正常組織的對比性(對比雜訊比,CNRe)分別取得兩種彈性影像品質比率來找到代表性的彈性影像,接著使用Level Set方法來切割出腫瘤輪廓,最後藉由腫瘤輪廓來擷取B-mode與彈性特徵,並且結合兩者來診斷腫瘤。本實驗中以151個經過病理驗證的病例進行測試,包含89個良性以及62個惡性的病例,並且使用本篇論文的方法所選之影像比較醫生所選的影像。經由實驗結果,當使用彈性特徵時,CNRe的準確率為82.12%,SNRe為82.12%,醫生選圖則是82.78%;當使用B-mode特徵時,CNRe的準確率為80.78%,SNRe為87.42%,醫生選圖則是84.11%;當結合B-mode與彈性特徵時,CNRe的準確率為86.09%,SNRe為90.07%,醫生選圖則是89.40%。因此,使用SNRe與CNRe所選擇的代表性影像可以取代醫生所選,並且將B-mode與彈性特徵結合時會有明顯的提升。
The breast cancer is always the main causes of death for women. In recent years, the sonoelastography has been used to measure the tumor strain. In the sonoelastography, the physicians need to lightly compress a tumor to obtain a dynamic elastographic image sequence. According to the displacement of the tumor, the tumor strain will be obtained on sonoelastography video. Finally, the physicians will choose the representative slice from the dynamic elastographic image sequence to diagnose the tumor. The purpose of this study is to use image quantification method to automatically choose a representative slice, and automatically segment the tumor contour to evaluate the features to diagnose the tumor. First, according to the uniformity inside the tumor (the signal to noise ratio, SNRe) or the contrast of the tumor and the surrounding normal tissue (contrast to noise ratio, CNRe), the two kinds of quality quantification methods will be used to select the representative slice. Then, the level set method is used to segment the tumor contour. Finally, the B-mode and elastography features by the tumor contour are extracted for diagnosis. Furthermore, the two kinds of features are combined to diagnose the tumors to improve the performance. In this study, 151 biopsy-proved sonoelastography composed of 89 benign and 62 malignant masses are used to evaluate the performance of the quantification methods and the representative slices selected by the proposed methods will be compared to the physician-selected slice. In the experiment result, as using elastography features, the diagnosis performance of accuracy is 82.12% (124/151) on representative slice of CNRe, 82.12% (124/151) on representative slice of SNRe, 82.78% (125/151) on the physician-selected slice; as using B-mode features, the diagnosis performance of accuracy is 80.79% (122/151) on representative slice of CNRe, 87.42% (132/151) on representative slice of SNRe, 84.11% (127/151) on the physician-selected slice; as combining the B-mode and elastography features, the diagnosis performance of accuracy is 86.09% (130/151) on representative slice of CNRe, 90.07% (136/151) on representative slice of SNRe, 89.40% (135/151) on the physician-selected slice. Therefore, the representative slice selected by SNRe and CNRe colud replace the physician-selected slice to reduce the physician’s load, and combining the B-mode and elastography features will increase the diagnosis performance.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/47756
Fulltext Rights: 有償授權
Appears in Collections:資訊工程學系

Files in This Item:
File SizeFormat 
ntu-99-1.pdf
  Restricted Access
3.34 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved