Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
    • 指導教授
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 醫學工程學研究所
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/42907
標題: 環形相位陣列式超音波結合多聚焦型態於乳房腫瘤熱手術之研究
Cylindrical Phased-array Ultrasound Transducer with Multifocal Patterns for Breast Tumor Thermal Therapy
作者: Chiang-Tien Lin
林江典
指導教授: 林文澧(Win-Li Lin)
共同指導教授: 陳永耀(Yung-Yaw chen)
關鍵字: 環形相位陣列超音波換能器,多聚焦點,乳房腫瘤,目標區域。,
cylindrical phased-array ultrasound transducer,multifocus patterns,breast tumor,planning target volume,
出版年 : 2009
學位: 碩士
摘要: 此研究的目的為探討環形相位陣列超音波換能器搭配多聚焦點掃描之加熱策略應用於乳癌熱手術之可行性。為了避免在治療時傷害過多的正常組織,一個1.2cm*1.2cm*1cm的目標區域(PTV)被選定為單一治療單元。若是目標區域大於單一治療單元的大小,則會將目標區域切割為數個子治療單元,並依序分別進行加熱,並且在各個子治療單元之間給予冷卻時間,以降低對周圍正常組織之傷害。同時亦探討血液灌流率以及腫瘤在不同位置下所造成之影響。除此之外,也針對一個淺層乳房腫瘤在不同周圍冷卻水的狀態下之治療情形進行探討。模擬結果顯示,較高的血液灌流率會減少整體的治療時間,目標區域在偏離乳房中心位置後,熱劑量輪廓有微量的變形。基於環形相位陣列超音波換能器擁有較大的聲窗口搭配上周圍冷卻水所帶來的冷卻效應,由模擬結果可以得知,以本系統進行淺層乳房腫瘤治療時,可以在目標區域產生一個均勻治療單元,且有效減少皮膚上的溫升。本研究中所提出的環形相位陣列超音波換能器系統以及加熱策略為乳房腫瘤之熱手術提供了一個有效的治療方法,並且可以大幅降低肋骨以及皮膚發生過熱之情況。
This study investigated the feasibility of using a 0.5 MHz cylindrical phased-array ultrasound transducer with multifocus patterns scanning to produce uniform heating for breast tumor thermal therapy. The breast was submerged in water and surrounded by the cylindrical phased-array ultrasound transducer. Multifocus patterns are electrically scanned by the phased-array to enlarge the treatment lesion in a single heating. To prevent overheating normal tissues, a large planning target volume (PTV) would be divided into several subunits and sequentially treated with a cooling phase between two successive heatings of the subunit. Heating results for different blood perfusion rates and locations of the PTV have been studied. Furthermore, a superficial breast tumor with different water temperatures was also studied. Simulation results show that perfusion rate reduces the treatment time significantly and the location of PTV affects the thermal lesion shape slightly. Due to large acoustic window and the effect of surrounding cooling water, this system was able to achieve a uniform heating without overheating the skin within a short treatment time. This study demonstrated that the proposed cylindrical phased-array ultrasound transducer can provide effective heating for breast tumor thermal therapy without overheating the skin and ribs within a reasonable treatment time.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/42907
全文授權: 有償授權
顯示於系所單位:醫學工程學研究所

文件中的檔案:
檔案 大小格式 
ntu-98-1.pdf
  未授權公開取用
6.01 MBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved