請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/3780
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 黃世建 | |
dc.contributor.author | Ming-Hong Huang | en |
dc.contributor.author | 黃銘弘 | zh_TW |
dc.date.accessioned | 2021-05-13T08:36:42Z | - |
dc.date.available | 2016-08-24 | |
dc.date.available | 2021-05-13T08:36:42Z | - |
dc.date.copyright | 2016-08-24 | |
dc.date.issued | 2016 | |
dc.date.submitted | 2016-08-09 | |
dc.identifier.citation | [1] 財)国土開發技術研究Й⑦Уみ,“建設省総合技術開發к①ЖラヱЬ:鉄筋ヵ⑦ヱэみЬ造建築物之超軽量化˙超高層化技術ソ開發(New RC)”,平成四年度構造性能分科会報告書,1993。
[2] Aoyama, H., “Design of Modern High-rise Reinforced Concrete Structures,” Imperial College, London, 2002. [3] 蔡仁傑,「鋼筋混凝土開孔牆之側力位移曲線預測」,碩士論文,國立台灣大學,土木工程學系,台北,民國104年7月,181頁。 [4] ACI Committee 318, (2014). “Building Code Requirments for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14),” American Concrete Institute, Farmigton Hills, Mich., 519 pp. [5] AIJ, (2010). “Standard for Structural Calculation of Reinforced Concrete Structures,” Architectural Institute of Japan, Tokyo, Japan, 525 pp. [6] Shimazaki, K., “Evaluation of Shear Crack Width Based on Shear force Ratio,” AIJ Journal of Technology and Design, V. 15, No. 29, pp. 139-142. [7] 邱建國、陳崇慶、林芳慶、紀凱甯,「實尺寸高強度鋼筋混凝土梁之剪力裂縫行為研究」,結構工程,第29卷,第4期,2014,第19-43頁。 [8] 邱建國、林芳慶、陳少謙、紀凱甯,「考慮構件剪力跨深比影響之高強度鋼筋混凝土梁剪力裂縫控制」,結構工程,第30卷,第3期,2015,第5-26頁。 [9] 蕭輔沛,鍾立來,葉勇凱,簡文郁,沈文成,邱聰智,周德光,趙宜峰,翁樸文,楊耀昇,褚有倫,凃耀賢,柴駿甫,黃世建,「校舍結構耐震評估與補強技術手冊(第三版)」,國家地震工程研究中心研究報告,NCREE 13-023,台北,2013。 [10] Lehman, D. E. and Moehle, J. P., 'Seismic Performance of Well-Confined Concrete Bridge Columns,' Pacific Earthquake Engineering Research Center Report, PEER 1998/01, California, 2000, 295 pp. [11] Paulay, T. and Priestley, M. J. N., 'Seismic Design of Reinforced Concrete and Masonry Buildings,' John Wiley & Sons, Inc., New York, 1992, 744 pp. [12] 翁樸文、李翼安、蔡仁傑、黃世建,「低矮型鋼筋混凝土剪力牆之側力位移曲線預測」,結構工程,已接受出版中,2016。 [13] 李宏仁,黃世建,「鋼筋混凝土結構不連續區域之剪力強度評估—軟化壓拉桿模型簡算法之實例應用」,結構工程,第17卷,第4期,2002,第53-70頁。 [14] Hwang, S. J. and Lee, H. J., 'Strength Prediction for Discontinuity Regions by Softened Strut-and-Tie Model,' Journal of Structural Engineering, ASCE, V. 128, No. 12, Dec., 2002, pp. 1519-1526. [15] Comité Euro-International du Béton, (2010). 'CEB-FIP Model Code 1990. Design Code,' Comité Euro-International du Béton, Thomas Telford, London, 402 pp. [16] 洪詩晴,「高強度鋼筋於低矮剪力牆往復載重行為研究」,碩士論文,國立台灣科技大學,營建工程系,台北,民國104年4月,111頁。 [17] 林永健,「開孔鋼筋混凝土剪力牆之側力位移曲線預測」,碩士論文,國立台灣大學,土木工程學系,台北,民國105年7月,195頁。 [18] 陳威志,「梁翼切削與弱梁柱交會區共存型梁柱接頭韌性行為研究」,碩士論文,國立台灣大學土木工程系,台北,民國88年,120頁。 [19] AIJ, (2004). 'Draft of Guidelines for Performance Evaluation of Earthquake Resistant Reinforced Concrete Buildings,' Architectural Institute of Japan, Tokyo, Japan 400 pp. [20] 中華民國地震工程學會,鋼筋混凝土建築物補強及修復參考圖說及解說,科技圖書,台北,第151-164頁(2015)。 | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/3780 | - |
dc.description.abstract | 台灣住宅在功能需求上為求防漏雨水、防盜與私密性隔音,常在構架中增設許多的RC牆版。其又為使用需求,住宅之填充牆版常設開門、開窗等之開孔型式。這些著重使用及功能需求的RC開孔填充牆,非為結構桿件,但其勁度相對結構桿件而言甚高,致使地震來襲時常是整體結構較先損傷的部分。
當這些RC開孔填充牆遭受嚴重破壞時,即便其他結構桿件尚屬良好,民眾仍無法信任住宅之安全性而繼續居住。若依此震損提出修繕計畫之解決辦法,住戶需遷離原址以便整體建築修復,此將造成民眾流離失所。另提整體拆除重建計畫,復又造成巨大的社會成本。時下民眾對此情況因無法信任住宅之安全性仍多採後者拆建之措施,將對社會造成相當損失。由此而知RC開孔填充牆之震損是一影響震後恢復的重要因素。 然而工程界對於RC開孔填充牆之耐震能力不甚了解,以致於耐震分析上常忽略RC開孔填充牆之貢獻以及RC開孔填充牆因震害而損壞的可能。此對建築之耐震設計、評估與補強工作非常不利。 本研究製作四座試體,測試牆體區域之長、寬、高分別為200 cm、20 cm、190 cm;設定邊界構材尺寸和是否開孔為變因以試驗方式進行研究,開孔型式皆為左右對稱、距基礎頂面85 cm之一 之窗型開孔。試驗是以單曲率、單向往復載重進行,欲了解高強度鋼筋混凝土開孔牆之裂縫行為與結構行為。試驗之後,藉所觀察之遲滯迴圈、裂縫寬度、裂縫長度、混凝土剝落面積、影像量測和應變計讀值,以探討試體之力學行為和裂縫發展行為。 就力學行為上,ACI 318-14要求若牆墩位於開孔牆之邊緣,則須於牆墩上下端設計水平鋼筋以傳遞牆墩之剪力至毗連牆段,但並未說明其定量設計方法。本研究藉應變計之讀值確定: 關於開孔上下方之水平鋼筋與邊界構材之剪力容量,僅開孔上下方之水平鋼筋可對剪力元素提供其水平承載能力。另就應變計結果亦顯示,本研究試體設計足以使高強度鋼筋發展其降伏強度( )。 就裂縫行為上具開孔之試體,其裂縫寬度發展、裂縫密度和混凝土剝落面積比明顯指出其相較未開孔試體較易達到損害標準。而殘餘裂縫之發展和尖峰裂縫發展與層間變位角之關係並非為一線性之發展。二者於混凝土剝落或擠碎前皆具一迅速發展期。 試驗後根據現有之損害評估與控制方法,評估本研究之試體損傷情形。本研究探討日本AIJ 2010與日本AIJ 2004之修復性能界限規定,建議以日本AIJ 2004修復性能界限I為修復性能界限較為適當。 | zh_TW |
dc.description.abstract | High-strength materials as concrete and steel are commonly used in high-rise, residential buildings. There are a lot of walls constructed in residential buildings. Due to functional requirement, openings of doors and windows are often required for these walls. The stiffness of the walls with openings is relatively high that the walls with openings are the first elements to be broken under earthquake.
These walls with openings are not the structural elements which provide the capacity of the building. When they are broken, the owners of the damaged buildings usually lose their confidence on building safety. In consequence, those buildings with damaged non-structural walls are demolished and rebuilt. Thus we need to investigate the damage control of the walls with openings. This study tested four specimens whose size of the test area is 200×20×190 cm. The test parameters are the size of the boundary element and the window openings. The walls with openings have the same size of the openings, 55×55 cm. The designed concrete strength is 70 MPa, and the nominal yielding strength of steel is 785 MPa. Test objective is to observe the relationship between the lateral force and the deformation, crack width, crack length, and concrete spalling ACI 318-14 requires to detail the horizontal reinforcement above and below the wall pier, but it doesn’t describe how to design clearly. By the strain gages attached on the steel, we can confirm that the horizontal reinforcement can surely play the role to transfer the shear from the wall pier to adjacent wall segments. By comparing the crack width, crack length, and the spalling area, it is found that the walls with openings have more severe damage than the walls without opening. As comparing the ratio of the peak crack width to the residual crack width, the ratio is not a constant. Finally, as for the reparability limit state defined in AIJ 2004 and AIJ 2010, this study recommends to adopt the reparability limit stage I provided by AIJ 2004. | en |
dc.description.provenance | Made available in DSpace on 2021-05-13T08:36:42Z (GMT). No. of bitstreams: 1 ntu-105-R03521221-1.pdf: 11655126 bytes, checksum: b0cac999701a55db2a2a39e84161464a (MD5) Previous issue date: 2016 | en |
dc.description.tableofcontents | 審定書 I
誌謝 III 摘要 V Abstract VII 目錄 IX 表目錄 XIII 圖目錄 XV 第一章 緒論 1 1.1 研究動機與目的 1 1.2 研究內容與方法 2 第二章 文獻回顧 5 2.1 裂縫控制之相關規範 5 2.1.1 美國混凝土學會ACI 318-14[4]規範之相關規定 5 2.1.2 日本建築學會AIJ 2010 [5]規範之相關規定 5 2.2 邱建國梁剪力裂縫行為與控制研究[7,8] 7 2.3 鋼筋混凝土開孔牆之力學分析 7 2.3.1 美國混凝土學會ACI 318-14[4]規範之相關規定 8 2.3.2 校舍結構耐震評估與補強技術手冊第三版 8 2.3.3 蔡仁傑預測之鋼筋混凝土開孔牆側力位移曲線 13 2.4 CEB-FIP 2010裂縫發展模型[15] 14 第三章 試驗計劃 17 3.1 試體設計 17 3.2 試體布置 20 3.3 量測規劃 22 3.3.1 外部量測 22 3.3.2 內部量測 22 3.4 試體製作 23 3.5 測試步驟 26 第四章 試驗結果 29 4.1 材料性質 29 4.2 試體載重與位移關係行為 29 4.2.1 試體個別行為 29 4.2.2 比較與討論 31 4.3 裂縫發展模式 32 4.3.1 試體個別行為 32 4.3.2 比較與討論 35 4.4 變形量測 37 4.4.1 應變計量測 37 4.4.2 影像量測 39 第五章 分析與討論 41 5.1 強度分析 41 5.1.1撓曲強度分析 41 5.1.2 剪力強度分析 41 5.1.3 比較及判斷破壞模式 42 5.2 損害分析 42 5.2.1 AIJ 2004 [19]關於各界限狀態定義 42 5.2.2 AIJ 2010 [5]之容許應力與剪力裂縫寬度 43 5.2.3 AIJ 2010 [5]與AIJ 2004 [19]之損害評估比較 45 5.3 剪力裂縫寬度分析 45 第六章 分析與討論 47 6.1 結論 47 6.2 未來研究展望 48 參考文獻 49 | |
dc.language.iso | zh-TW | |
dc.title | 高強度鋼筋混凝土開孔牆之震損控制研究 | zh_TW |
dc.title | Study on Damage Control of High-Strength Reinforced Concrete Wall with Openings | en |
dc.type | Thesis | |
dc.date.schoolyear | 104-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 邱建國,鄭敏元,林克強 | |
dc.subject.keyword | 開孔填充牆,裂縫行為,高強度,震損控制, | zh_TW |
dc.subject.keyword | high-strength,reinforced concrete,wall with opening,damage control, | en |
dc.relation.page | 119 | |
dc.identifier.doi | 10.6342/NTU201601722 | |
dc.rights.note | 同意授權(全球公開) | |
dc.date.accepted | 2016-08-09 | |
dc.contributor.author-college | 工學院 | zh_TW |
dc.contributor.author-dept | 土木工程學研究所 | zh_TW |
顯示於系所單位: | 土木工程學系 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-105-1.pdf | 11.38 MB | Adobe PDF | 檢視/開啟 |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。