Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 生物資源暨農學院
  3. 獸醫專業學院
  4. 獸醫學系
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/35368
Title: 運用高效液相層析法對飼料中安默西林及安比西林檢測方法之建立
Simultaneous determination of amoxicillin and ampicillin in feed by liquid chromatography with fluorescence detection
Authors: Chi-Ho Liu
劉其和
Advisor: 張紹光
Keyword: 安默西林,安比西林,高效液相層析儀,飼料,
Amoxicillin,Ampicillin,HPLC,feed,
Publication Year : 2005
Degree: 碩士
Abstract: 本實驗目的在以高效液相層析法建立同時檢測飼料中安默西林(amoxicillin)及安比西林(ampicillin)的方法。移動相為0.01 M 磷酸二氫鉀緩衝液(pH 2.5):乙腈(82: 18, v/v),層析管柱使用SymmetryShield® column(RP8, 5μm, I.D. 4.6 × 250 mm),螢光檢測器檢測波長設定為λex 358 nm、λem 440 nm進行檢測。兩種藥物均以三種不同濃度添加於飼料中之平均回收率介於93.28∼102.69 % 及88.35∼106.14 %;回收率之天內及天間變異係數皆在4 % 以下。安默西林及安比西林於飼料中之檢測極限分別為0.3536及0.0269 mg/kg,定量極限分別為1.1787及0.0896 mg/kg。本試驗所建立之檢測方法通過準確度、精密度、專一性、線性等各項確效,可實際應用於檢測飼料中安默西林及安比西林之含量。
The study was to develop a high performance liquid chromatography (HPLC) method for determination of amoxicillin and ampicillin in feeds. Fluorescence detector was set at excitation wavelength of 358 nm and emission wavelength of 440 nm. A SymmetryShield® column (RP8, 5 μm, 4.6 × 250 mm I.D.) with a mobile phase consisting of 0.01 M potassium dihydrogen phosphate (pH 2.5):acetonitrile (82: 18, v/v) was used. The average recoveries of amoxicillin and ampicillin from spiked samples were 93.28 – 102.69 % and 88.35 – 106.14 % with repeatabilities below 4 % R.S.D.. The limits of detection of amoxicillin and ampicillin were 0.3536 and 0.0269 mg/kg, the limits of quantitation were 1.1787 and 0.0896 mg/kg for feed, respectively. Not only the method of validation was performed, but also specificity, reproducibility, precision and accuracy were confirmed. This assay has been applied to the measurement of amoxicillin and ampicillin in feeds.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/35368
Fulltext Rights: 有償授權
Appears in Collections:獸醫學系

Files in This Item:
File SizeFormat 
ntu-94-1.pdf
  Restricted Access
653.65 kBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved