Title: 以數學規劃法做冷卻水和製程用水網路最適化設計之研究
Superstructure-based MINLP Formulation for Synthesis of
Cooling-Water and Water-Using Networks with Intermediate Mains
Authors: Li-Feng Lin
林立峰
Advisor: 陳誠亮
Co-Advisor: 陳文智
Keyword: 整合,冷卻水網路,超結構圖,
Synthesis,Cooling Water Network,Superstructure,
Publication Year : 2006
Degree: 碩士
Abstract: 水資源是地球上非常重要的資源之一,而在許多方面,地球人對於水的依賴性也相當高。
在工廠製程方面,作者以工廠用水量超大的兩個部分來做介紹,分別是冷卻水網路與
製程用水網路,因為水在這兩個部分扮演著極為重要的角色。
在傳統型的冷卻水網路設計型態上,熱交換器單元間的管線連接方式是以串聯的方式去設計,
不但增加了冷卻水網路結構管線的複雜度,而且整個冷卻水網路系統的韌性也大大降低。
為了解決這方面的問題,可以在冷卻水網路系統中加入中間儲存槽的設計,
不但降低了冷卻水網路結構管線的複雜度,而且整個冷卻水網路系統的韌性也大大提升。
另外在本研究設計中,在網路結構中加入少數根冷卻器單元間的管線連接,
不但對於整個系統的韌性沒有很大的影響,且冷卻水的使用量也節省了不少。
最後將產生一個混合整數非線性規劃的問題;在本研究的後面也設計的幾個簡單的問題,
根據問題設計數種不同的情況,並依不同的情況進行分析與討論。另外,
在製程用水網路的部份,水不但可以當作反應物或產物,且在吸收、萃取的製程中,
水也可以當作質量分離溶劑。
A novel superstructure-based MINLP formulation is proposed for synthesis of cooling water networks with intermediate mains.
The proposed mathematical model considers the generic problem confronted
in the design of a re-circulating cooling water system, including
stretching the cooler network design and setting the operation constraints.
Besides the original design items, this research probes into how the number of
intermediate cooling water mains influence the re-circulating cooling water
system's performance.
We also study how the conditional direct connections among cooling units
can decrease the consumption of the re-circulating cooling water with
a little sacrifice of piping complexity.
Typical representative examples are presented to demonstrate
the viability of proposed superstructure-based MINLP formulation.
Supported by the results of computer analysis, the network superstructure and its
design scheme can effectively accomplish the goal of unraveling the design problem
of the re-circulating cooling water system with intermediate cooling water
mains, and proffering the optimal structure in designing the re-circulating
cooling water systems.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/33224
Fulltext Rights: 有償授權
Appears in Collections:化學工程學系

Files in This Item:
File SizeFormat 
ntu-95-1.pdf
  Restricted Access
1.29 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved