Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 醫學院
  3. 牙醫專業學院
  4. 臨床牙醫學研究所
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/26397
Title: ProFile鎳鈦旋轉器械經臨床使用及消毒後之影響
Influence after Clinical Use and Sterilization on
ProFile Nickel-Titanium Rotary Instruments
Authors: Ji-Uei Liou
劉季煒
Advisor: 林俊彬 博士(Chun-Pin Lin)
Keyword: 鎳鈦根管銼,高溫消毒,示差掃描熱量測定,靜態彎曲測試,疲勞斷裂,
rotary endodontic Ni–Ti instruments,heat sterilization,differential scanning calorimetric (DSC),bending test,cyclic fatigue,
Publication Year : 2008
Degree: 碩士
Abstract: 鎳鈦根管銼在使用上有減低醫師手部疲勞及克服彎曲根管的優點,但是無法克服器械斷裂的缺點。本實驗是將臨床使用後的鎳鈦根管銼做分析探討,並利用示差掃描熱量測定,靜態彎曲測試以及疲勞斷裂實驗,以瞭解鎳鈦根管銼經高壓消毒鍋、乾熱消毒鍋及卡夾式快速消毒鍋對ProFile鎳鈦根管銼做多次高溫消毒後其晶相轉變和機械性質的影響。臨床使用後的鎳鈦根管銼以斷裂比例(58.4%)較變形比例(41.6%)高,較大號數以斷裂比例較變形比例高。斷裂中以疲勞斷裂比例(58.6%)高於扭轉斷裂比例(41.4%)。示差掃描熱量測定其結果顯示經多次高溫消毒之鎳鈦根管銼其晶相轉變時之降溫熱焓降低,靜態彎曲測試則發現經多次高溫消毒之鎳鈦根管銼彈性增加且較容易產生變形甚至於容易疲勞斷裂,尤其是經多次乾熱消毒鍋消毒較高壓消毒鍋及卡夾式快速消毒鍋明顯。
A major concern with use of nickel-titanium engine-driven rotary instruments is fracture without warning. The purpose of this study was to analyze the type and frequency of defects in ProFile nickel-titanium rotary endodontic files after routine clinical use and to draw conclusions regarding the reasons for failure. The differential scanning calorimetric (DSC) studies were utilized to undergo phase transformation within rotary nickel-titanium (Ni-Ti) endodontic instruments of the as-received condition and after more heat sterilization cycles. Static Bending Test was tested on the mechanical behavior and cyclic fatigue devices were tested on fatigue resistance of rotary endodontic Ni–Ti instruments after more heat sterilization cycles. The result was nickel-titanium rotary endodontic files after routine clinical used had more percentage on fracture (58.4%) than distortion (41.6%). The large size file had more percentage on fracture than distortion. Fracture of endodontic rotary instruments could occur under two circumstances: torsional fracture and cyclic fatigue. The cyclic fatigue (58.6%) was the major type than torsional fracture (41.4%). The differential scanning calorimetric (DSC) studies exhibit the total enthalpy change decrease within rotary nickel-titanium (Ni-Ti) endodontic instruments after 11 heat sterilization cycles. The heat cycle of the hybrid Ni–Ti instruments may be effective to increase the flexibility and decrease on cyclic fatigue cycle, specially with dry heat sterilization than steam autoclave and cassette autoclave.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/26397
Fulltext Rights: 未授權
Appears in Collections:臨床牙醫學研究所

Files in This Item:
File SizeFormat 
ntu-97-1.pdf
  Restricted Access
6.24 MBAdobe PDF
Show full item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved