標題: "開發聚(3,4-乙烯二氧噻吩)/氧化石墨烯修飾之電極作為美沙拉秦電化學感測應用"
Development of PEDOT/GO-modified Electrode for Mesalazine Electrochemical Sensing Application
作者: Shu-Yun Hsiao
蕭姝芸
指導教授: 羅世強(Shyh-Chyang Luo)
關鍵字: 美沙拉秦,導電高分子,聚(3,4-乙烯二氧噻吩),氧化石墨烯,玻璃碳電極,電化學感測器,循環伏安法,微分脈衝伏安法,
mesalazine,conducting polymer,poly(3,4-ethylenedioxythiophene),graphene oxide,glassy carbon electrode,electrochemical sensor,cyclic voltammetry,differential pulse voltammetry,
出版年 : 2020
學位: 碩士
摘要: 本研究利用聚3,4-乙烯二氧噻吩(poly(3,4-Ethylenedioxythiophene), PEDOT)與氧化石墨烯(graphene oxide, GO)來修飾玻碳電極,並利用循環伏安法和微分脈衝伏安法等電化學方法在此修飾後的電極上偵測美沙拉秦。相較於未修飾的玻璃碳電極,所有經過聚3,4-乙烯二氧噻吩修飾的玻璃碳電極都顯示出對美沙拉秦的電流響應有顯著的增強效果,這是因為聚3,4-乙烯二氧噻吩具帶正電荷的主鏈可以吸引帶有負電荷的美沙拉秦。此外,我們發現與其他pH值和緩衝液相比,當美沙拉秦在pH 6.0的磷酸鹽緩衝溶液中做電化學偵測時會在氧化電位 +0.22 V處產生最高的氧化峰值電流。最後,與PEDOT/GC和PEDOT-GO修飾的玻璃碳電極相比,PEDOT/GO表現出最大的美沙拉秦氧化峰電流增加,且美沙拉秦的氧化峰電流值會隨濃度在0.01 mM到1.00 mM的範圍線性增加,校準方程為y = 21.94x + 0.01(R^2 = 0.971),偵測極限為10 μM。為了進一步證明PEDOT/GO修飾的玻璃碳電極的應用性,我們還在維生素C、尿酸以及人類血清蛋白的干擾下對MES進行微分脈衝伏安法測量。
A simple electrochemical method was investigated for the detection of mesalazine (MES) on three kinds of poly(3,4-ethylenedioxythiophene) (PEDOT) and graphene oxide (GO)-modified glassy carbon electrode (GCE) by both cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. Compared with bare GCE, the PEDOT-modified GC electrodes shows a significant enhancement in the current responses for MES due to the positively charged backbones of PEDOT, which can attract the negatively charged MES. Moreover, we found the oxidation of MES reached a maximum current at + 0.22 V vs Ag/AgCl in PBS at pH = 6.0 compared in other PBS buffer at other pH values. Finally, PEDOT/GO/GC electrode presented the best MES detection performance and showed the greatest increases in MES oxidation current compared among all the modified GC electrodes. The oxidation current increased linearly with the MES concentration from 0.01 mM to 1.00 mM with a calibration equation of y=21.94x+0.01 (R^2 = 0.971), and the limit of detection is 10 μM. To demonstrate the application of the PEDOT/GO/GC electrode, we applied the DPV measurement of MES in the presence of three interferences, including ascorbic acid, uric acid and human serum albumin, respectively.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/17432
DOI: 10.6342/NTU202002468
全文授權: 未授權
顯示於系所單位:材料科學與工程學系

文件中的檔案:
檔案 大小格式 
U0001-0508202014561300.pdf
  目前未授權公開取用
3.8 MBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved