請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/9136
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 黃榮山(Long-Sun Huang) | |
dc.contributor.author | Yung-Jen Cheng | en |
dc.contributor.author | 鄭詠仁 | zh_TW |
dc.date.accessioned | 2021-05-20T20:10:29Z | - |
dc.date.available | 2014-08-18 | |
dc.date.available | 2021-05-20T20:10:29Z | - |
dc.date.copyright | 2011-08-18 | |
dc.date.issued | 2011 | |
dc.date.submitted | 2011-08-14 | |
dc.identifier.citation | [1] G. Binnig, C. F. Quate, Ch Gerber, 'Atomic force
microscope,' Physical Review Letters 56 (9), 930 (1986). [2] T. Itoh, T. Suga, 'Force sensing microcantilever using sputtered zinc oxide thin film,' Applied Physics Letters 64 (1), 37-39 (1994). [3] J. P. Cleveland, S. Manne, D. Bocek, P. K. Hansma, 'A nondestructive method for determining the spring constant of cantilevers for scanning force microscopy,' Review of Science Instruments 64 (2), 403-405 (1993). [4] J. K. Gimzewski, Ch Gerber, E. Meyer, R. R. Schlittler, 'Observation of a chemical reaction using a micromechanical sensor,' Chemical Physics Letters 217 (5-6), 589-594 (1994). [5] T. Thundat, R. J. Warmack, G. Y. Chen, D. P. Allison, 'Thermal and ambient induced deflections of scanning force microscope cantilevers,' Applied Physics Letters 64 (21), 2894-2896 (1994). [6] T. Thundat, G. Y. Chen, R. J. Warmack, D. P. Allison, E. A. Wachter, 'Vapor detection using resonating microcantilevers,' Analytical Chemistry 67 (3), 519- 521 (1995). [7] http://scholar.google.com.tw. [8] J. Lai, T. Perazzo, Z. Shi, A. Majumdar, 'Optimization and performance of high-resolution micro- optomechanical thermal sensors,' Sensors and Actuators A: Physical 58 (2), 113-119 (1997). [9] R. H. Ma, C. Y. Lee, Y. H. Wang, H. J. Chen, 'Microcantilever-based weather station for temperature, humidity and flow rate measurement,' Microsystem Technologies 14 (7), 971-977 (2008). [10] J. Mertens, E. Finot, T. Thundat, A. Fabre, M. H. Nadal, V. Eyraud, E. Bourillot, 'Effects of temperature and pressure on microcantilever resonance response,' Ultramicroscopy 97 (1-4), 119-126. [11] A. Kooser, R. L. Gunter, W. D. Delinger, T. L. Porter, M. P. Eastman, 'Gas sensing using embedded piezoresistive microcantilever sensors,' Sensors and Actuators B: Chemical 99 (2-3), 474-479 (2004). [12] M. Alvarez, A. Calle, J. Tamayo, L. M. Lechuga, A. Abad, A. Montoya, 'Development of nanomechanical biosensors for detection of the pesticide DDT,' Biosensors and Bioelectronics 18 (5-6), 649-653 (2003). [13] S. Cherian, R. K. Gupta, B. C. Mullin, T. Thundat, 'Detection of heavy metal ions using protein- functionalized microcantilever sensors,' Biosensors and Bioelectronics 19 (5), 411-416 (2003). [14] A. Vidic, D. Then, Ch Ziegler, 'A new cantilever system for gas and liquid sensing,' Ultramicroscopy 97 (1-4), 407-416 (2003). [15] Bryan C. Fagan, Christopher A. Tipple, Ziling Xue, Michael J. Sepaniak, Panos G. Datskos, 'Modification of micro-cantilever sensors with sol-gels to enhance performance and immobilize chemically selective phases,' Talanta 53 (3), 599-608 (2000). [16] R. Berger, E. Delamarche, H. P. Lang, C. Gerber, J. K. Gimzewski, E. Meyer, H. J. Guntherodt, 'Surface Stress in the Self-Assembly of Alkanethiols on Gold,' Science 276 (5321), 2021-2024 (1997). [17] A. Bietsch, J. Y. Zhang, M. Hegner, H. P. Lang, C. Gerber, “Rapid functionalization of cantilever array sensors by inkjet printing,” Nanotechnology 15(8), 873-880 (2004) [18] G. Shekhawat, S. H. Tark, V. P. Dravid, 'MOSFET- embedded microcantilevers for measuring deflection in biomolecular Sensors,' Science 311 (5767), 1592-1595 (2006). [19] S. H. Tark, A. Srivastava, S. Chou, G. Shekhawat, V. P. Dravid, 'Nanomechanoelectronic signal transduction scheme with metal-oxide-semiconductor field-effect transistor-embedded microcantilevers,' Applied Physics Letters 94 (10) (2009). [20] S. Mostafa, I. Lee, S. K. Islam, S. A. Eliza, G. Shekhawat, V. P. Dravid, F. S. Tulip, 'Integrated MOSFET-embedded-cantilever-based biosensor characteristic for detection of anthrax simulant,' IEEE Electron Device Letters 32 (3), 408-410 (2011). [21] H. Mori, K. Hata, T. Hashimoto, I. W. Wu, A. G. Lewis, M. Koyanagi. 'Low-temperature operation of oolycrystalline tilicon thin-film transistors,' Japanese Journal of Applied Physics Part 1-Regular Papers Short Notes & Review Papers 30, 3710-3714 (1991). [22] C. H. Kim, K. S. Sohn, J. Jang. 'Temperature dependent leakage currents in polycrystalline silicon thin film transistors.' Journal of Applied Physics 81, 8084-8090 (1997). [23] J. Thaysen, A. Boisen, O. Hansen, S. Bouwstra, 'Atomic force microscopy probe with piezoresistive read-out and a highly symmetrical Wheatstone bridge arrangement,' Sensors and Actuators A: Physical 83 (1- 3), 47-53 (2000). [24] A. Johansson, J. Hales, 'Temperature effects in Au piezoresistors integrated in SU-8 cantilever chips,' Journal of Micromechanics and Microengineering 16(12), 2564-2569 (2006). [25] J. Thaysen, R. Marie, A. Boisen, presented at the Micro Electro Mechanical Systems, 2001. MEMS 2001. The 14th IEEE International Conference on, 2001. [26] A. Johansson, J. Hales, 'Temperature effects in Au piezoresistors integrated in SU-8 cantilever chip, 'journal of Micromechanics and Microengineering 16(12), 2564-2569 (2006). [27] 辜煜夫, '壓阻式微懸臂樑生物感測器溫度效應量測、消除與應用'. 國 立台灣大學工學院應用力學所碩士論文, 2009. [28] 林品延, '薄膜電晶體式微懸臂樑生物感測器之設計與製作'. 國立台灣 大學工學院應用力學所碩士論文, 2010. [29] J. M. Engasser and C. Horvath, 'Diffusion and kinetics with immobilized enzymes In: L.B. Wingard, E. Katchalski-Katzir and L. Goldstein, Editors, Applied Biochemistry and Bioengineering,' vol. 1. Immobilized Enzyme Principles, Academic Press, New York, 127–220 (1976). [30] 莊榮輝, http://juang.bst.ntu.edu.tw/BC2008/index.htm. 2008. [31] S. Liming, A. Bhagwat, 'Application of a molecular beacon—real-time PCR technology to detect Salmonella species contaminating fruits and vegetables,' International Journal of Food Microbiology 95(2), 177- 187 (2004). [32] H A Lee, G M Wyatt, S Bramham, M R Morgan, 'Enzyme- linked immunosorbent assay for Salmonella typhimurium in food: feasibility of 1-day Salmonella detection,' Appl. Environ. Microbiol. 56 (6), 1541-1546 (1990). [33] J. Homola, S. Yee, G. Gauglitz, 'Surface plasmon resonance sensors: review, ' Sensors & Actuators: B. Chemical 54(1-2), 3-15 (1999). [34] Q. Cai, E. Zellers, 'Dual-chemiresistor GC detector employing monolayer-protected metal nanocluster interface,' Analytical Chemistry Washington DC 74(14), 3533-3539, (2002). [35] E. C. Walter, R. M. Penner, H. Liu, K. H. Ng, M. P. Zach, F. Favier, 'Sensors from electrodeposited metal nanowires,' Surface and Interface Analysis 34(1), 409- 412 (2002). [36] E. S. Snow, F. K. Perkins, E. J. Houser, S. C. Badescu, T. L. Reinecke, 'Chemical detection with a single-walled carbon nanotube capacitor,' Science 307 (5717), 1942-1945 (2005). [37] B. Matthews, Li Jing, S. Sunshine, L. Lerner, J. W. Judy, 'Effects of electrode configuration on polymer carbon-black composite chemical vapor sensor performance,' IEEE Sensors Journal 2 (3), 160-168 (2002). [38] D. A. Buttry, M. D. Ward, 'Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalance,' Chemical Reviews 92 (6), 1355-1379 (1992). [39] C. Caliendo, E. Verona, V. Anisimkin, 'Surface acoustic wave humidity sensors: a comparison between different types of sensitive membrane,' Smart Materials and Structures 6, 707-715 (1997). [40] C. Ziegler, 'Cantilever-based biosensors,' Analytical and Bioanalytical Chemistry 379 (7), 946-959 (2004). [41] G. Campbell, Detection and quantification of pathogens, proteins, and molecules using piezoelectric-excited millimeter-sized cantilever (PEMC) sensors, 2006. [42] P. Bergveld, 'Development of an ion-sensitive solid- state device for neurophysiological measurements,' IEEE Transactions on Biomedical Engineering 17 (1), 70-71 (1970). [43] M. J. Schoning, A. Poghossian, 'Bio FEDs (Field-Effect devices): State-of-the-art and new directions,' Electroanalysis 18, 1893-1900 (2006). [44] P. Estrela, P. Li, S. D. Keighley, P. Migliorato, 'Label-free electrical biosensor arrays: a new challenge for TFT technology,' Journal of Korean Physical Society 54, 498-504 (2009). [45] R. W. Cattral, Chemical Sensors, Oxford University Press, (1997). [46] F. Yan, P. Estrela, Y. Mo, P. Migliorato, H. Maeda, S. Inoue, T. Shimoda, 'Polycrystalline silicon ion sensitive field effect transistors,' Applied Physics Letters 86 (5), 053901-053901-053903 (2005). [47] P. Estrela, A. G. Stewart, F. Yan, P. Migliorato, 'Field effect detection of biomolecular interactions,' Electrochimica Acta 50 (25-26), 4995-5000 (2005). [48] P. Estrela, D. Paul, P. Li, S. D. Keighley, P. Migliorato, S. Laurenson, P. K. Ferrigno, 'Label-free detection of protein interactions with peptide aptamers by open circuit potential measurement,' Electrochimica Acta 53 (22), 6489-6496 (2008). [49] A. S. Sedra, K. C. Smith, Microelectronic circuits, Oxford University, (2004). [50] 施敏, 半導體元件物理與製作技術. 2 ed. 2002: 國立交通大學 [51] Y. S. Ma, Thin-film transistors for microelectronics, UMI, 1999. [52] 劉漢文,影像顯示科技導論,國立中興大學電機工程系暨光電工程所 [53] http://www.ioffe.rssi.ru/SVA/NSM/Semicond/Si/ electric.html [54] Y. Kuo, Thin film transistors 2 volume set: materials and processes, Springer, 2003 [55] C. H. Nan, L. C. Len, L. T. Fu, 'An analytical model for the above-threshold characteristics of polysilicon thin-film transistors,' IEEE Transactions on Electron Devices, 42 (7), 1240-1246 (1995). [56] F. V. Farmakis, J. Brini, G. Kamarinos, C. T. Angelis, C. A. Dimitriadis, M. Miyasaka, 'On-current modeling of large-grain polycrystalline silicon thin-film transistors,' IEEE Transactions on Electron Devices, 48 (4), 701-706 (2001). [57] J. G. Fossum, A. Ortiz-Conde, 'Effects of grain boundaries on the channel conductance of SOl MOSFET's,' IEEE Transactions on Electron Devices, 30 (8), 933-940 (1983). [58] H. I. Chan, C. Y. Wu, 'An analytical grain-barrier Height Model and its Characteristic for Intrinsic poly-si thin-film transistor,' IEEE Transactions on Electron Devices 45, 2245 ( 1998). [59] A. Cacciato, F. Benyaich, C. Spinella, E. Rimini, P. Romano, P. Ward, “Electrical characterization of polycrystalline silicon films on si substrate processed by rapid thermal annealing”, Semiconductor Science and Technology 8, 327 (1993). [60] Y. Morimoto, Y. Jinno, K. Hirai, H. Ogata, T. Yamada, K. Yoneda, 'Influence of the grain boundaries and intragrain defects on the performance of poly-si thin film transistors,' Journal of The Electrochemical Society 144 (7), 2495-2501 (1997). [61] H. Kuriyama, T. Nohda, S. Ishida, T. Kuwahara, S. Noguchi, S. Kiyama, S. Tsuda, S. Nakano, 'Lateral grain-growth of poly-si films with a specific orientation by an excimer-laser annealing method,' Japanese Journal of Applied Physics Part 1 - Regular Papers Short Notes & Review Papaper 32 (12B), 6190- 6195 (1993). [62] F. V. Farmakis, J. Brini, G. Kamarinos, C. T. Angelis, C. A. Dimitriadis, M. Miyasaka, 'On-current modeling of large-grain polycrystalline silicon thin-film transistors,' IEEE Transactions on Electron Devices, 48 (4), 701-706 (2001). [63] J. H. Cheon, J. H. Bae, J. Jang, ' Mechanical stability of poly-Si TFT on metal foil,' Solid –State Electronics 52(3), 473-477 (2008). [64] P. C. Kuo, A. Jamshidi-Roudbari, M. Hatalis, 'Effects of mechanical strain on characteristics of polycrystalline silicon thin-film transistors fabricated on stainless steel foil,' Journal of Display Technology 5 (6), 202-205 (2009). [65] P. C. Kuo, A. Jamshidi-Roudbari, M. Hatalis, 'Electrical characteristics and mechanical limitation of polycrystalline silicon thin-film transistor on steel foil under strain,' Journal of Applied physics 106 (11), 114502-5 (2009). [66] G. G. Stoney, 'The Tension of Metallic Films Deposited by Electrolysis.' Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character 82(553), 172-175 (1909). [67] K. M. Goeders, J. S. Colton, L. A. Bottomley, 'Microcantilevers: sensing chemical interactions via mechanical motion,' Chemical Review 108 (2), 522-542 (2008). [68] D. Sarid, 'Scanning force microscopy-with Applications to electric,magnetic and atomic forces, ' Microscopy Microanalysis Microstructures 2(6), 649-649 (1991).. [69] L. Torrijo, L. Guillermo, Development of cantilevers for biomolecular measurements, 2008. [70] A. Choudhury, P. J. Hesketh, T. Thundat, Z. Y. Hu, 'A piezoresistive microcantilever array for surface stress measurement: curvature model and fabrication,' Journal of Micromechanical and Microengineering 17 (10), 2065-2076 (2007). [71] F. T. Goericke, W. P. King, 'Modeling piezoresistive microcantilever sensor response to surface stress for biochemical sensors,' IEEE Sensors Journal 8 (8), 1404-1410 (2008). [72] F. Goericke, Simulation, fabrication and characterization of piezoresistive bio-/chemical sensing microcantilevers, 2007. [73] P. Townsend, D. Barnett, T. Brunner, 'Elastic relationships in layered composite media with approximation for the case of thin films on a thick substrat,' Journal of Applied Physics 62, 4438 (1987). [74] S. Hong, T. P. Weihs, O. K. Kwon, J. C. Bravman, presented at the Electronic Manufacturing Technology Symposium, 1989, Proceedings. Seventh IEEE/CHMT International, 1989. [75] H. Tada, A. E. Kumpel, R. E. Lathrop, J. B. Slanina, P. Nieva, P. Zavracky, I. N. Miaoulis, P. Y. Wong, 'Thermal expansion coefficient of polycrystalline silicon and silicon dioxide thin films at high temperatures,' Journal of Applied Physics 87 (9), 4189-4193 (2000). [76] N. C. C. Lu, L. Gerzberg, Lu Chih-Yuan, J. D. Meindl, 'Modeling and optimization of monolithic polycrystalline silicon resistors,' IEEE Transactions on Electron Devices 28 (7), 818-830 (1981). | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/9136 | - |
dc.description.abstract | 近幾年隨著生物技術及微系統的發展,各國社會趨勢逐漸走向高齡化,醫療資源的需求日益增大。有別於傳統相形笨重和高成本且速度緩慢之檢驗設備,一種具有微小化、可攜式、高靈敏度、少量檢體、免螢光標定以及具快速檢測的生物晶片,已經成為生物領域、微機電領域一重要指標性研究發展方向。
本論文利用微機電技術與半導體技術製作出以多晶矽薄膜場效電晶體作為訊號轉換機制的微懸臂樑感測器。本研究所製作出薄膜電晶體之電子遷移率為30~34cm2/Vs,並利用力學為基礎於固定VG=7V探討感測元件最佳靈敏度為0.034μA/μm。本研究所作之薄膜場效電晶體(CONTROL)與薄膜場效電晶體式微懸臂樑(TFT-MCL)受溫度效應時的電流變化(ΔI/ΔT)分別為0.51μA/℃與0.60μA/℃,可以發現薄膜電晶體受溫度效應影響十分顯著。將其分別對載子遷移率(Mobility)、臨限電壓(Threshold Voltage)、汲極電流(ID-VD) 於溫度效應下作研究。由研究結果,在薄膜場效電晶體式微懸臂樑與控制組溫度效應中,發現載子遷移率隨溫度上升而增加、臨限電壓趨勢雖然相同,對溫度的靈敏度分別有1.45倍與0.76倍的差距存在。藉由ID-VD實驗發現飽和電流訊號受溫度效應影響的變化,在控制組與場效電晶體式微懸臂樑上的變化量是不同的,將其微懸臂樑溫度效應分別於力學特性、熱傳特性、電特性做研究探討。實驗結果發現到其主要分別來自電阻熱效應(Temperature Coefficient of Resistance)佔74%、雙膜效應(Bimorph Effect)佔1%、熱消散效應(Heat Dissipation Effect)佔9%以及微懸臂樑之起始翹曲不同所造成的本質溫度效應差異(Initial Deformation Induced Variation of Temperature Effect)佔16%,由實驗結果發現溫度效應於微懸臂樑在訊號量測時,造成訊號值誤判的可能性很高,故探討溫度效應補償的可行性。 本論文最後利用溫度補償方法,將上述所列出微懸臂樑溫度效應之因素,利用控制組當作補償參照組來扣除微懸臂樑之溫度效應。研究結果顯示經過溫度補償後,可將微懸臂樑受溫度效應影響減少約60倍。應用在單點負荷施加於微懸臂樑上,並用溫度補償將溫度效應消除,得到單點負荷真實訊號值。此溫度補償方法優點是不論是在溫差範圍多大情況下,皆可進行溫度效應之補償,此補償方法讓薄膜場效電晶體式微懸臂樑感測器不需要龐大的恆溫儀器。因此溫度補償機制的研究,無疑的對於感測儀器是一重大的貢獻。本實驗所使用之方法非常簡易,將對薄膜場效電晶體式微懸臂樑的穩定性與應用面有所提升,並期許對於微流道生醫晶片或其他領域,存在溫度效應相關問題的,能有所助益。 | zh_TW |
dc.description.abstract | In recent year, with the development of biotechnology and microsystems, the aging society is gradually coming. Portable biosensors offer advantages over conventional instruments on miniaturization, label-free feature, portability, real-time rapid diagnosis, and potential low cost, showing the direction of research and development.
This study successfully utilized thin-film transistor(TFT) as a sensing transducer to convert induced stresses of a microcantilever(MCL) sensor. The thin-film transistor–based microcantilever(TFT-based MCL) was fabricated by semiconductor and micro-electromechanical system(MEMS) fabrication technology. Meanwhile, the mobility of the TFT device was measured to be 30~34 cm2/Vs, and the sensitivity of TFT-based MCL device was 0.034 μA/μm. For sensing purpose of the TFT-based MCL sensor, the device was very sensitive to temperature effect, which induced a result of a considerable current change. The sensitivity of the TFT-based MCL for temperature to saturation current was measured to be 0.6 μA/℃. In addition, the temperature effect induced changes of mobility and threshold voltage simultaneously. By the test of ID-VD with respect to temperature effect, five major factors were found to play considerable roles in the TFT-based MCL, including temperature coefficient of resistance of 74%, bimorph effect of about 1%, heat dissipation of 9%, and initial residual stress deformation-induced variation of temperature effect of 15%. Finally, this study utilized a fixed TFT on a substrate as temperature sensor for thermal effect compensation to eliminate the temperature effect of the TFT-based MCL. The temperature feedback has been proved to demonstrate the device with a large scale of temperature variation. As a result, the TFT-based MCL sensor has been expected for biochemical detection with the elimination of temperature-sensitive effect. | en |
dc.description.provenance | Made available in DSpace on 2021-05-20T20:10:29Z (GMT). No. of bitstreams: 1 ntu-100-R98543026-1.pdf: 11853153 bytes, checksum: cc829b79e74795219e54358b75b1572c (MD5) Previous issue date: 2011 | en |
dc.description.tableofcontents | 謝誌......................................................I
摘要....................................................III Abstract.................................................V 目錄....................................................VII 圖目錄...................................................XI 表目錄..................................................XIX 第一章、序論...............................................1 1.1引言...................................................1 1.2文獻回顧................................................2 1.2.1微懸臂樑感測器文獻回顧..................................2 1.2.2電晶體溫度效應文獻回顧..................................5 1.3研究動機與目的...........................................8 1.4論文大綱...............................................10 第二章、生物感測器之原理與應用...............................12 2.1生物感測器基本原理......................................12 2.2生物分子固定化技術......................................13 2.3辨識分子專一性鍵結原理...................................14 2.4生物感測器之類型與機制比較...............................17 2.5微懸臂樑生物感測器量測方式...............................19 2.6薄膜電晶體式生物感測器...................................21 第三章、薄膜電晶體式微懸臂樑感測器運作原理與理論...............23 3.1薄膜電晶體的運作原理....................................23 3.2電晶體原件電性參數萃取方法...............................25 3.3薄膜電晶體的結構與通道材料...............................27 3.4多晶矽通道的晶格缺陷與電性影響............................29 3.5多晶矽材料晶格大小改善之製程方法..........................32 3.6多晶矽材料晶格受應變理論.................................36 3.7微懸臂樑機械特性分析....................................37 3.7.1微懸臂樑受應力變化分析.................................37 3.7.2微懸臂樑表面應力計算..................................41 3.7.3彈簧常數與共振頻......................................42 第四章、薄膜電晶體式微懸臂樑生物感測系統之設計與製作.............45 4.1薄膜電晶體之設計........................................45 4.1.1通道材料.............................................45 4.1.2摻雜離子.............................................45 4.1.3摻雜濃度.............................................46 4.1.4通道長寬比...........................................46 4.2薄膜電晶體式微懸臂樑之設計...............................47 4.2.1中性軸與殘留應力......................................47 4.2.2薄膜電晶體結構選擇....................................49 4.2.3薄膜厚度.............................................49 4.2.4電晶體的位置與形狀設計.................................50 4.2.5微懸臂樑幾何尺寸設計..................................51 4.3薄膜電晶體式微懸臂樑製作流程..............................55 4.4製程問題討論與改善......................................63 第五章、薄膜電晶體式微懸臂樑的溫度效應.........................70 5.1雙膜效應(Bimorph Effect)...............................70 5.2電阻溫度效應(Temperature coefficient resistance).......77 5.3雜質散射(impurity scattering)..........................79 5.4微懸臂樑之熱消散效應(Heat Dissipation Effect)...........80 第六章、薄膜電晶體式微懸臂樑於力學特性量測與溫度效應之量測與補償...82 6.1薄膜電晶體式微懸臂樑共振頻量測與探討.......................82 6.1.1實驗架構與方法........................................82 6.1.2實驗結果.............................................83 6.1.3討論................................................83 6.2薄膜電晶體式微懸臂樑於施加單點負荷之量測與探討..............84 6.2.1實驗架構與方法........................................84 6.2.2實驗結果.............................................85 6.2.3討論................................................87 6.3薄膜電晶體式微懸臂樑之懸浮與未懸浮溫度效應影響與探討.........87 6.3.1實驗架構與方法........................................87 6.3.2溫度效應於電子遷移率與臨限電壓上影響.....................88 6.3.3溫度效應於ID-VD上影響.................................91 6.3.4討論................................................95 6.4雙膜效應於薄膜電晶體式微懸臂樑之影響量測...................96 6.4.1實驗步驟與方法........................................96 6.4.2實驗結果.............................................97 6.4.3討論...............................................101 6.5薄膜電晶體式微懸臂樑與控制組之熱消散影響量測...............101 6.5.1實驗步驟與方法.......................................101 6.5.2實驗結果............................................102 6.5.3討論...............................................105 6.6微懸臂樑起始翹曲與溫度效應關係之量測......................105 6.6.1實驗步驟與方法.......................................105 6.6.2實驗結果............................................107 6.6.3討論...............................................110 6.7應用薄膜電晶體當作溫感測器..............................111 6.7.1實驗步驟與方法.......................................111 6.7.2薄膜電晶體線性誤差大小................................112 6.7.3薄膜電晶體於不同溫度下雜訊大小.........................113 6.7.4薄膜電晶體於不同溫度下訊號偏移量大小....................116 6.7.5討論...............................................117 6.8利用薄膜電晶體熱效應作為微膜電晶體式微懸臂樑溫度補償........119 6.8.1實驗架構............................................121 6.8.2消除薄膜電晶體電阻熱效應..............................122 6.8.3將薄膜電晶體電阻熱效應與雙膜效應消除....................125 6.8.4溫度補償應用於薄膜電晶體微懸臂樑之力學特性量測...........128 6.8.5溫度補償總結........................................120 6.8.5.1溫度補償誤差討論...................................130 6.8.5.2溫度補償前後雜訊討論...............................130 6.8.5.3不同起始翹曲微懸臂樑於溫度補償前後性能討論.............134 6.8.5.4電晶體與壓阻溫度補償比較討論.........................136 第七章、結論與未來展望.....................................138 7.1結論.................................................138 7.2未來展望..............................................141 參考文獻.................................................143 | |
dc.language.iso | zh-TW | |
dc.title | 場效電晶體式微懸臂樑感測器於力學特性與溫度效應之研究 | zh_TW |
dc.title | Mechanical Characteristics and Temperature Effect of a Field-effect Transistor Microcantilever Sensor | en |
dc.type | Thesis | |
dc.date.schoolyear | 99-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 陳俊杉(Chuin-Shan Chen),趙福杉(Fu-Shan Jaw) | |
dc.subject.keyword | 微懸臂樑,薄膜電晶體,生醫感測器,表面應力,溫度效應,溫度補償,載子遷移率,臨限電壓, | zh_TW |
dc.subject.keyword | Microcantilever,Thin-film transistor (TFT),Micro-electromechanical system (MEMS),Temperature effect,Temperature coefficient of resistance (TCR),surface stress, | en |
dc.relation.page | 148 | |
dc.rights.note | 同意授權(全球公開) | |
dc.date.accepted | 2011-08-15 | |
dc.contributor.author-college | 工學院 | zh_TW |
dc.contributor.author-dept | 應用力學研究所 | zh_TW |
顯示於系所單位: | 應用力學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-100-1.pdf | 11.58 MB | Adobe PDF | 檢視/開啟 |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。