請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/89132
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 李佳翰 | zh_TW |
dc.contributor.advisor | Jia-Han Li | en |
dc.contributor.author | 張家瑜 | zh_TW |
dc.contributor.author | Chia-Yu Chang | en |
dc.date.accessioned | 2023-08-16T17:15:54Z | - |
dc.date.available | 2023-11-09 | - |
dc.date.copyright | 2023-08-16 | - |
dc.date.issued | 2023 | - |
dc.date.submitted | 2023-08-09 | - |
dc.identifier.citation | [1] Gullstrand, A. L. L. V. A. R. (1901). How I found the mechanism of intracapsular accommodation. Nobel Lectures, Physiology or Medicine, 1921, 414.
[2] Rayamajhi, A., Helmer, M., Hetz, M., & Neumann, C. (2021). The human eye: From Gullstrand’s eye model to ray tracing today. In Lux junior 2021: 15. Internationales Forum für den lichttechnischen Nachwuchs, 04.–06. Juni 2021, Ilmenau: Tagungsband (pp. 201-209). [3] Yen, C. T., Tsai, C. M., & Fang, Y. C. (2013). A study of optical design of aspheric optical glasses based on Kiou & Brennan eyes spherical model. Optik, 124(14), 1726-1729. [4] Atchison, D. A., & Thibos, L. N. (2016). Optical models of the human eye. Clinical and Experimental Optometry, 99(2), 99-106. [5] Greivenkamp, J. E., Schwiegerling, J., Miller, J. M., & Mellinger, M. D. (1995). Visual acuity modeling using optical raytracing of schematic eyes. American journal of ophthalmology, 120(2), 227-240. [6] Liou, H. L., & Brennan, N. A. (1997). Anatomically accurate, finite model eye for optical modeling. JOSA A, 14(8), 1684-1695. [7] Almeida, M. S. D., & Carvalho, L. A. (2007). Different schematic eyes and their accuracy to the in vivo eye: a quantitative comparison study. Brazilian Journal of Physics, 37(2A), 378-387. [8] Bakaraju, R. C., Ehrmann, K., Papas, E., & Ho, A. (2008). Finite schematic eye models and their accuracy to in-vivo data. Vision research, 48(16), 1681-1694. [9] Atchison, D. A., & Thibos, L. N. (2016). Optical models of the human eye. Clinical and Experimental Optometry, 99(2), 99-106. [10] Greivenkamp, J. E., Schwiegerling, J., Miller, J. M., & Mellinger, M. D. (1995). Visual acuity modeling using optical raytracing of schematic eyes. American journal of ophthalmology, 120(2), 227-240. [11] Liou, H. L., & Brennan, N. A. (1997). Anatomically accurate, finite model eye for optical modeling. JOSA A, 14(8), 1684-1695. [12] Bakaraju, R. C., Ehrmann, K., Papas, E., & Ho, A. (2008). Finite schematic eye models and their accuracy to in-vivo data. Vision research, 48(16), 1681-1694. [13] Kirilenko, M. S., Khorin, P. A., & Porfirev, A. P. (2016). Wavefront analysis based on Zernike polynomials. In CEUR Workshop Proceedings (Vol. 1638, pp. 66-75). [14] Lakshminarayanan, V., & Fleck, A. (2011). Zernike polynomials: a guide. Journal of Modern Optics, 58(7), 545-561. [15] Carpio, M., & Malacara, D. (1994). Closed Cartesian representation of the Zernike polynomials. Optics communications, 110(5-6), 514-516. [16] McAlinden, C., McCartney, M., & Moore, J. (2011). Mathematics of Zernike polynomials: a review. Clinical & experimental ophthalmology, 39(8), 820-827. [17] Rampat, R., & Gatinel, D. (2021). Multifocal and extended depth-of-focus intraocular lenses in 2020. Ophthalmology, 128(11), e164-e185. [18] Sudhir, R. R., Dey, A., Bhattacharrya, S., & Bahulayan, A. (2019). AcrySof IQ PanOptix intraocular lens versus extended depth of focus intraocular lens and trifocal intraocular lens: a clinical overview. Asia-Pacific Journal of Ophthalmology (Philadelphia, Pa.), 8(4), 335. [19] Alio, J. L., Plaza-Puche, A. B., Férnandez-Buenaga, R., Pikkel, J., & Maldonado, M. (2017). Multifocal intraocular lenses: an overview. Survey of ophthalmology, 62(5), 611-634. [20] Alio, J. L., Plaza-Puche, A. B., Férnandez-Buenaga, R., Pikkel, J., & Maldonado, M. (2017). Multifocal intraocular lenses: an overview. Survey of ophthalmology, 62(5), 611-634. [21] Gordon, R. A., & Donzis, P. B. (1985). Refractive development of the human eye. Archives of ophthalmology, 103(6), 785-789. [22] de Carvalho, L. M., de Lima Monteiro, D. W., & de Oliveira, O. G. (2020). Computational modeling and optimization of a diffractive trifocal intraocular lens with step heights modulated by a cosine function. Optics Communications, 476, 126325. [23] Hwey-Lan Liou and Noel A. Brennan, "Anatomically accurate, finite model eye for optical modeling," J. Opt. Soc. Am. A 14, 1684-1695 (1997) [24] Zoulinakis, G., Esteve-Taboada, J. J., Ferrer-Blasco, T., Madrid-Costa, D., & Montés-Micó, R. (2017). Accommodation in human eye models: a comparison between the optical designs of Navarro, Arizona and Liou-Brennan. International journal of ophthalmology, 10(1), 43. [26] G. Smith, B. K. Pierscionek, and D. A. Atchison, “The optical modelling of the human lens,” Ophthalmic. Physiol. Opt. 11, 359–369 (1991). [27] J. M. Royston, M. C. M. Dunne, and D. A. Barnes, “Measurement of the posterior corneal radius using slit lamp and Purkinje image techniques,” Ophthalmic. Physiol. Opt. 10, 385–388 (1990). [28] N. Brown, “The change in lens curvature with age,” Exp. Eye Res. 19, 175–183 (1974). [29] A. Gullstrand, Helmholtz’s Physiological Optics (Optical Society of America, New York, 1924), Appendix, pp. 350–358. [30] J. G. Sivak and T. Mandelman, “Chromatic dispersion of the ocular media,” Vision Res. 22, 997–1003 (1982). [31] Zhang, A. (2020). Multifocal diffractive lens design in ophthalmology. Applied Optics, 59(31), 9807-9823. [32] Al-Hamdani, A. H., Rashid, H. G., & Hashim, H. T. (2021). Optimum design of the hybrid (diffractive/refractive) multifocal intraocular lenses implanted within human eye. Kuwait journal of science, 48(1). [33] Vega, F., Valentino, M., Rigato, F., & Millán, M. S. (2021). Optical design and performance of a trifocal sinusoidal diffractive intraocular lens. Biomedical Optics Express, 12(6), 3338-3351. [34] Hashim, H. A., & Mohammed, M. F. (2023). Design and modeling of corneal aberration correction with diffractive IOL based on ZEMAX. Results in Optics, 11, 100398. [35] Alshami, M., Wabby, A., & Mousselly, M. F. (2015). Design and development of Binary Diffractive Germanium Lens by thin film deposition. Journal of the European Optical Society-Rapid publications, 10. [36] Leyland, M., & Zinicola, E. (2003). Multifocal versus monofocal intraocular lenses in cataract surgery: a systematic review. Ophthalmology, 110(9), 1789-1798. [37] Ma, R., Ji, L., & Yan, T. (2020). Laser multi-focus precision cutting of thick sapphire by spherical aberration rectification. Optics and Lasers in Engineering, 126, 105876. [38] Hartmann, P., Jedamzik, R., Reichel, S., & Schreder, B. (2010). Optical glass and glass ceramic historical aspects and recent developments: a Schott view. Applied optics, 49(16), D157-D176. [39] Reardon, P. J., & Chipman, R. A. (1989). Buchdahl’s glass dispersion coefficients calculated from Schott equation constants. Applied optics, 28(16), 3520-3523. [40] Sigler, R. D. (1986). Glass selection for airspaced apochromats using the Buchdahl dispersion equation. Applied optics, 25(23), 4311-4320. [41] GHOSH, Gorachand. Sellmeier coefficients and dispersion of thermo-optic coefficients for some optical glasses. Applied optics, 1997, 36.7: 1540-1546. [42] Suvarnaphaet, P., Suksan, P., Pechprasarn, S., & Albutt, N. (2019). Optical Device Adapted to Smartphone for Direct Imaging Retinal Blood Vessels. In Applied Mechanics and Materials (Vol. 891, pp. 275-279). Trans Tech Publications Ltd. [43] Vega, F., Valentino, M., Rigato, F., & Millán, M. S. (2021). Optical design and performance of a trifocal sinusoidal diffractive intraocular lens. Biomedical Optics Express, 12(6), 3338-3351. [44] Lang A, Portney V. Interpreting multifocal intraocular lens modulation transfer functions. J Cataract Refract Surg. 1993;19(4):505–12. [45] Carson D, et al. Optical bench performance of AcrySof((R)) IQ ReSTOR((R)), AT LISA((R)) tri, and FineVision((R)) intraocular lenses. Clin Ophthalmol. 2014;8:2105–13. [46] CARSON, Daniel, et al. Optical bench performance of 3 trifocal intraocular lenses. Journal of Cataract & Refractive Surgery, 2016, 42.9: 1361-1367. [47] Gatinel, D., & Houbrechts, Y. (2013). Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench. Journal of Cataract & Refractive Surgery, 39(7), 1093-1099. [48] https://www.thorlabs.com/thorproduct.cfm?partnumber=LC1258 [49] Jones, L. H. (1963). Raman spectra of the linear dicyanides. Spectrochimica Acta, 19(10), 1675-1681. [50] Wang, Y., Spencer, P., Yao, X., & Ye, Q. (2006). Effect of coinitiator and water on the photoreactivity and photopolymerization of HEMA/camphoquinone‐based reactant mixtures. Journal of Biomedical Materials Research Part A: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials, 78(4), 721-728. [51] Loader, E. J. (1971). Laser Raman spectra of styrene adsorbed on silica. Journal of Catalysis, 22(1), 41-48. | - |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/89132 | - |
dc.description.abstract | 隨著人類平均壽命的增長,越來越多人受到眼睛退化的困擾,水晶體的退化使得需要更換人工水晶體的患者增加,國際組織也開始關注此議題,為了更精準的提供患者所需的人工水晶體,有許多研究關於人眼數據的量測、人工水晶體的設計和植入人眼後的成像品質。從最初使患者能看到遠距離勢力範圍的單焦人工水晶體到現在視力範圍擴大到多焦的人工水晶體,而設計方面則是從折射光學結構到折射和繞射混和式的結構,因此本研究設計朝折射和繞射混和式的三焦人工水晶體並分析其成像品質,並和其他市售多焦的人工水晶體比較,在增加焦距範圍且維持成像品質為設計多焦人工水晶體的挑戰。
此外,利用紫外光-可見光-近紅外光光譜儀、Shack-Hartmann波前量測系統和多功能顯微拉曼分析儀對此研究水凝膠材料的性質有更進一步的了解,提供未來人工水晶體設計的參考。 | zh_TW |
dc.description.abstract | With the increasing average lifespan of humans, more and more people are experiencing age-related eye degeneration. The degeneration of the intraocualr lens leads to an increasing number of patients requiring intraocualr intraocular lens. International organizations have also begun to pay attention to this issue. In order to provide more accurate intraocualr intraocular lens to patients, there are many studies focused on measuring human eye data, designing intraocualr lenses, and evaluating the imaging quality after implantation.
From the first monofocal intraocular lens that allowed patients to see in the distance, to the current multifocal intraocular lens that expand the range of vision. The design has evolved from refractive optical structures to a combination of refraction and diffraction. Therefore, this study aims to design a trifocal intraocular lens with a combination of refraction and diffraction and analyze its imaging quality. A comparison is made with other commercially available multifocal lenses. The challenge of increasing the focal range while maintaining imaging quality in designing multifocal intraocular intraocular lens. In addition, the use of ultraviolet-visible-near-infrared spectroscopy , Shack-Hartmann wavefront measurement system and multifunctional micro-Raman analysis provides material properties of the hydrogel material in this study, offering references for future intraocular lens design. | en |
dc.description.provenance | Submitted by admin ntu (admin@lib.ntu.edu.tw) on 2023-08-16T17:15:54Z No. of bitstreams: 0 | en |
dc.description.provenance | Made available in DSpace on 2023-08-16T17:15:54Z (GMT). No. of bitstreams: 0 | en |
dc.description.tableofcontents | 致謝 ii
中文摘要 iii Abstract iv CONTENTS iv LIST OF FIGURES vi LIST OF TABLES viii 第一章、緒論 1 1.1 研究背景 1 1.2 研究目的與動機 2 第二章、文獻回顧 3 2.1 人眼光學模型選擇 3 2.2 波前像差分析中的Zernike多項式 6 2.3 人工水晶體光學設計 9 第三章 研究方法 11 3.1 建構人眼光學模型 11 3.2 後曲面-三焦人工水晶體光學設計 14 3.3 前曲面結構設計 15 3.4 人工水晶體材料折射率及色散相關參數 17 3.5 前後曲面皆優化的設計 19 3.6 自適應Shack-Hartmann波前量測系統實驗架設 20 第四章 結果與討論 23 4.1 人眼模型 23 4.2 人工水晶體材料-水凝膠樣品量測 25 4.3 前後曲面結構設計 27 4.4 前後曲面皆優化的結構設計 29 4.5 成像分析 30 4.5.1 MTF值 30 4.5.2 Zernike像差值 32 4.5.3 光扇圖(Ray Fan) 33 4.5.4 光斑圖(Spot Diagram) 34 4.5.5 繞射圖像分析(Diffraction image analysis) 36 4.6 拉曼光譜儀量測樣品結果 39 第五章 結論與未來研究方向 41 參考文獻 42 | - |
dc.language.iso | zh_TW | - |
dc.title | 三焦人工水晶體之光學設計及成像品質分析 | zh_TW |
dc.title | Trifocal Intraocular Lens Optical Design and Retinal Image Quality | en |
dc.type | Thesis | - |
dc.date.schoolyear | 111-2 | - |
dc.description.degree | 碩士 | - |
dc.contributor.oralexamcommittee | 王一中;張恆華;顏家鈺;戴子安 | zh_TW |
dc.contributor.oralexamcommittee | I-Jong Wang;Herng-Hua Chang;Jia-Yush Yen;Chi-An Dai | en |
dc.subject.keyword | 三焦人工水晶體,成像品質,水凝膠材料,紫外光-可見光-近紅外光光譜儀,多功能顯微拉曼分析儀,Shack-Hartmann波前量測系統, | zh_TW |
dc.subject.keyword | trifocal intraocular lens,imaging quality,hydrogel material,ultraviolet-visible-near-infrared spectroscopy,multifunctional micro-Raman analysis,Shack-Hartmann wavefront measurement system, | en |
dc.relation.page | 45 | - |
dc.identifier.doi | 10.6342/NTU202303310 | - |
dc.rights.note | 同意授權(全球公開) | - |
dc.date.accepted | 2023-08-10 | - |
dc.contributor.author-college | 工學院 | - |
dc.contributor.author-dept | 工程科學及海洋工程學系 | - |
顯示於系所單位: | 工程科學及海洋工程學系 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-111-2.pdf | 3.37 MB | Adobe PDF | 檢視/開啟 |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。