Skip navigation

DSpace JSPUI

DSpace preserves and enables easy and open access to all types of digital content including text, images, moving images, mpegs and data sets

Learn More
DSpace logo
English
中文
  • Browse
    • Communities
      & Collections
    • Publication Year
    • Author
    • Title
    • Subject
    • Advisor
  • Search TDR
  • Rights Q&A
    • My Page
    • Receive email
      updates
    • Edit Profile
  1. NTU Theses and Dissertations Repository
  2. 電機資訊學院
  3. 生醫電子與資訊學研究所
Please use this identifier to cite or link to this item: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/73038
Full metadata record
???org.dspace.app.webui.jsptag.ItemTag.dcfield???ValueLanguage
dc.contributor.advisor鍾孝文(Hsiao-Wen Chung)
dc.contributor.authorCheng-Ping Chienen
dc.contributor.author錢政平zh_TW
dc.date.accessioned2021-06-17T07:14:53Z-
dc.date.available2021-01-20
dc.date.copyright2021-01-20
dc.date.issued2020
dc.date.submitted2021-01-06
dc.identifier.citation1. Becker CD, Grossholz M, Mentha G, de Peyer R, Terrier F. MR cholangiopancreatography: technique, potential indications, and diagnostic features of benign, postoperative, and malignant conditions. Eur Radiol 1997;7:865-74.
2. Takehara Y. Can MRCP replace ERCP? J Magn Reson Imaging 1998;8:517-34.
3. Vitellas KM, Keogan MT, Spritzer CE, Nelson RC. MR cholangiopancreatography of bile and pancreatic duct abnormalities with emphasis on the single-shot fast spin-echo technique. Radiographics 2000;20:939-57.
4. Sodickson A, Mortele KJ, Barish MA, Zou KH, Thibodeau S, Tempany CM. Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques. Radiology 2006;238:549-59.
5. Glockner JF, Saranathan M, Bayram E, Lee CU. Breath-held MR cholangiopancreatography (MRCP) using a 3D Dixon fat-water separated balanced steady state free precession sequence. Magn Reson Imaging 2013;31:1263-70.
6. Fulcher AS, Turner MA, Capps GW, Zfass AM, Baker KM. Half-Fourier RARE MR cholangiopancreatography: experience in 300 subjects. Radiology 1998;207:21-32.
7. Yamashita Y, Abe Y, Tang Y, Urata J, Sumi S, Takahashi M. In vitro and clinical studies of image acquisition in breath-hold MR cholangiopancreatography: single-shot projection technique versus multislice technique. AJR Am J Roentgenol 1997;168:1449-54.
8. Textor HJ, Flacke S, Pauleit D, Keller E, Neubrand M, Terjung B, Gieseke J, Scheurlen C, Sauerbruch T, Schild HH. Three-dimensional magnetic resonance cholangiopancreatography with respiratory triggering in the diagnosis of primary sclerosing cholangitis: comparison with endoscopic retrograde cholangiography. Endoscopy 2002;34:984-90.
9. Morita S, Ueno E, Suzuki K, Machida H, Fujimura M, Kojima S, Hirata M, Ohnishi T, Imura C. Navigator-triggered prospective acquisition correction (PACE) technique vs. conventional respiratory-triggered technique for free-breathing 3D MRCP: an initial prospective comparative study using healthy volunteers. J Magn Reson Imaging 2008;28:673-7.
10. Hand JW, Lagendijk JJ, Hajnal JV, Lau RW, Young IR. SAR and temperature changes in the leg due to an RF decoupling coil at frequencies between 64 and 213 MHz. J Magn Reson Imaging 2000;12:68-74.
11. Chu ML, Chien CP, Wu WC, Chung HW. Gradient- and spin-echo (GRASE) MR imaging: a long-existing technology that may find wide applications in modern era. Quant Imaging Med Surg 2019;9:1477-84.
12. Oshio K, Feinberg DA. GRASE (Gradient- and spin-echo) imaging: a novel fast MRI technique. Magn Reson Med 1991;20:344-9.
13. Feinberg DA, Oshio K. GRASE (gradient- and spin-echo) MR imaging: a new fast clinical imaging technique. Radiology 1991;181:597-602.
14. Yoshida M, Nakaura T, Inoue T, Tanoue S, Takada S, Utsunomiya D, Tsumagari S, Harada K, Yamashita Y. Magnetic resonance cholangiopancreatography with GRASE sequence at 3.0T: does it improve image quality and acquisition time as compared with 3D TSE? Eur Radiol 2018;28:2436-43.
15. Nam JG, Lee JM, Kang HJ, Lee SM, Kim E, Peeters JM, Yoon JH. GRASE revisited: breath-hold three-dimensional (3D) magnetic resonance cholangiopancreatography using a Gradient and Spin Echo (GRASE) technique at 3T. Eur Radiol 2018;28:3721-8.
16. Mugler JP 3rd, Brookeman JR. Off-resonance image artifacts in interleaved-EPI and GRASE pulse sequences. Magn Reson Med 1996;36:306-13.
17. Johnson G, Feinberg DA, Venkataraman V. A comparison of phase encoding ordering schemes in T2-weighted GRASE imaging. Magn Reson Med 1996;36:427-35.
18. Jenkins JT, Glass G, Ballantyne S, Fullarton GM. Effect of MRCP introduction on ERCP practice: are there implications for service and training? Gut 2006;55:1365-6.
19. Irie H, Honda H, Kuroiwa T, Yoshimitsu K, Aibe H, Shinozaki K, Masuda K. Pitfalls in MR cholangiopancreatographic interpretation. Radiographics 2001;21:23-37.
20. Riordan RD, Khonsari M, Jeffries J, Maskell GF, Cook PG. Pineapple juice as a negative oral contrast agent in magnetic resonance cholangiopancreatography: a preliminary evaluation. Br J Radiol 2004;77:991-9.
21. Espinosa MG, Sosa M, De León-Rodríguez LM, Córdova T, Bernal-Alvarado J, Avila-Rodríguez M, Reyes-Aguilera JA, Ortíz JJ, Barrios FA. Blackberry (Rubus spp.): a pH-dependent oral contrast medium for gastrointestinal tract images by magnetic resonance imaging. Magn Reson Imaging 2006;24:195-200.
22. Chavhan GB, Almehdar A, Moineddin R, Gupta S, Babyn PS. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children. Pediatr Radiol 2013;43:1086-92.
23. Masui T, Katayama M, Kobayashi S, Nozaki A, Sugimura M, Ikeda M, Sakahara H. Magnetic resonance cholangiopancreatography: comparison of respiratory-triggered three-dimensional fast-recovery fast spin-echo with parallel imaging technique and breath-hold half-Fourier two-dimensional single-shot fast spin-echo technique. Radiat Med 2006;24:202-9.
24. Zhang J, Israel GM, Hecht EM, Krinsky GA, Babb JS, Lee VS. Isotropic 3D T2-weighted MR cholangiopancreatography with parallel imaging: feasibility study. AJR Am J Roentgenol 2006;187:1564-70.
25. Lohöfer FK, Kaissis GA, Rasper M, Katemann C, Hock A, Peeters JM, Schlag C, Rummeny EJ, Karampinos D, Braren RF. Magnetic resonance cholangiopancreatography at 3 Tesla: Image quality comparison between 3D compressed sensing and 2D single-shot acquisitions. Eur J Radiol 2019;115:53-8.
26. Zhu L, Xue H, Sun Z, Qian T, Weiland E, Kuehn B, Asbach P, Hamm B, Jin Z. Modified breath-hold compressed-sensing 3D MR cholangiopancreatography with a small field-of-view and high resolution acquisition: clinical feasibility in biliary and pancreatic disorders. J Magn Reson Imaging 2018;48:1389-99.
27. Nandalur KR, Hussain HK, Weadock WJ, Wamsteker EJ, Johnson TD, Khan AS, D'Amico AR, Ford MK, Nandalur SR, Chenevert TL. Possible biliary disease: diagnostic performance of high-spatial-resolution isotropic 3D T2-weighted MRCP. Radiology 2008;249:883-90.
28. Chung HW, Chen CY, Zimmerman RA, Lee KW, Lee CC, Chin SC. T2-Weighted fast MR imaging with true FISP versus HASTE: comparative efficacy in the evaluation of normal fetal brain maturation. AJR Am J Roentgenol 2000;175:1375-80.
29. Reinhold C, Guibaud, L, Genin G, Bret PM (1995) MR cholangiopancreatography: comparison between two-dimensional fast spin-echo and three-dimensional gradient-echo pulse sequences. J Magn Reson Imaging 4: 379–384.
30. Hennig J, Nauerth A, Friedburg H. RARE imaging: a fast imaging method for clinical MR. Magn Reson Med 1986;3:823-33.
31. Keller PJ, Karis JP, Fram EK, Heiserman JE, Drayer BP. An alternative to GRASE: toward spin-echo-like contrast with independent reconstruction of gradient-echo images. Magn Reson Med 1996;36:804-8.
32. Fellner F, Schmitt R, Trenkler J, Fellner C, Böhm-Jurkovic H. Turbo gradient-spin-echo (GRASE): first clinical experiences with a fast T2-weighted sequence in MRI of the brain. Eur J Radiol 1995;19:171-6.
33. Umek W, Ba-Ssalamah A, Prokesch R, Mallek R, Heimberger K, Hittmair K. Imaging of the brain using the fast-spin-echo and gradient-spin-echo techniques. Eur Radiol 1998;8:409-15.
34. Patel MR, Klufas RA, Shapiro AW. MR imaging of diseases of the brain: comparison of GRASE and conventional spin-echo T2-weighted pulse sequences. AJR Am J Roentgenol 1995;165:963-6.
35. Fellner F, Held P, Fellner C, Schmitt R, Obletter N. Fast spin-echo (FSE) and gradient- and spin-echo (GRASE) in fast MRI of the pelvis. Magn Reson Imaging 1997;15:517-24.
36. Postema S, Pattynama PM, van Rijswijk CS, van Erkel A, Tjin A Ton ER. MR imaging of uterine cervical carcinoma: comparison between fast spin-echo MRI and GRASE. Eur Radiol 1998;8:45-9.
37. Welch KM, Windham J, Knight RA, Nagesh V, Hugg JW, Jacobs M, Peck D, Booker P, Dereski MO, Levine SR. A model to predict the histopathology of human stroke using diffusion and T2-weighted magnetic resonance imaging. Stroke 1995;26:1983-9.
38. Mitchell DG, Vinitski S, Burk DL Jr, Levy D, Rifkin MD. Variable-flip-angle spin-echo MR imaging of the pelvis: more versatile T2-weighted images. Radiology 1989;171:525-9.
39. Röschmann P. Radiofrequency penetration and absorption in the human body: limitations to high-field whole body nuclear magnetic resonance imaging. Med Phys 1987;14:922-31.
40. Nitz WR. Fast and ultrafast non-echo-planar MR imaging techniques. Eur Radiol 2002;12:2866-82.
41. Jovicich J, Norris DG. GRASE imaging at 3 Tesla with template interactive phase-encoding. Magn Reson Med 1998;39:970-9.
42. Mugler JP 3rd. Improved three-dimensional GRASE imaging with the SORT phase-encoding strategy. J Magn Reson Imaging 1999;9:604-12.
43. Kim H, Kim DH, Park J. Variable-flip-angle single slab 3D GRASE imaging with phase-independent image reconstruction. Magn Reson Med 2015;73:1041-52.
44. Itatani R, Namimoto T, Kajihara H, Yoshimura A, Katahira K, Nasu J, Matsushita I, Sakamoto F, Kidoh M, Yamashita Y. Preoperative evaluation of the cystic duct for laparoscopic cholecystectomy: comparison of navigator-gated prospective acquisition correction- and conventional respiratory-triggered techniques at free-breathing 3D MR cholangiopancreatography. Eur Radiol 2013;23:1911-8.
45. Schmidt S, Chevallier P, Novellas S, Gelsi E, Vanbiervliet G, Tran A, Schnyder P, Bruneton JN. Choledocholithiasis: repetitive thick-slab single-shot projection magnetic resonance cholangiopancreaticography versus endoscopic ultrasonography. Eur Radiol 2007;17:241-50.
46. Lee JH, Lee SS, Kim JY, Kim IS, Byun JH, Park SH, Lee MG. Parallel imaging improves the image quality and duct visibility of breathhold two-dimensional thick-slab MR cholangiopancreatography. J Magn Reson Imaging 2014;39:269-75.
dc.identifier.urihttp://tdr.lib.ntu.edu.tw/jspui/handle/123456789/73038-
dc.description.abstract我們利用3T磁振造影儀,比較兩種不同序列所呈現出的膽道胰管影像(MRCP),在不同位置其清晰程度差異性比較分析。所採用的兩種序列分別為gradient- and spin-echo (GRASE) 3D影像,以及thick-slab fast spin-echo (FSE) 2D影像。全部受檢測者總共為95人(男/女 = 49:46,年齡介於 25-75歲),3T磁振造影參數調校以一次呼吸閉氣的時間內能夠完成影像,且不超過組織安全可曝露能量(SAR)的上限值為原則。膽道及胰管依解剖構造分為八個區段來比較影像呈現,依是否符合臨床診斷所能接受之影像品質,採用4個等第分類。
在總膽管、總肝管區段,3D GRASE MRCP 的表現比2D FSE MRCP 來得好 (兩者p < 0.001),在右前肝內膽管(p < 0.001)、右後肝內膽管(p < 0.005) 、胰管遠段 (p < 0.05)區域,則為2D FSE MRCP比3D GRASE MRCP 的表現好。另外可以發現同時合併這兩個序列的影像一起判讀,左肝內膽管無法診斷的情形可以減少至10個受測者(5.3%),而原本3D GRASE MRCP有31個(16.3%)受測者左肝內膽管無法診斷,2D FSE MRCP有21個(11.1%)受測者左肝內膽管無法診斷。
儘管在單一次呼吸閉氣的MRCP檢查中,3D GRASE MRCP 對於總膽管及總肝管的診斷較為有利,但2D FSE MRCP在較小管徑的位置仍舊有較好的表現,兩者為互補性的關係。
zh_TW
dc.description.abstractWe compare the depiction conspicuity of three-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP) based on gradient- and spin-echo (GRASE) and two-dimensional (2D) thick-slab MRCP using fast spin-echo (FSE) in different segments of hepatic and pancreatic ducts at 3T. There were 95 subjects (M/F = 49:46, age range = 25-75) performed for at 3T. The parameters are adjusted under the constraints of specific absorption rate and scan time within single breath-hold. Conspicuity of eight ductal segments was graded by two experienced raters using a 4-point score.
3D GRASE MRCP outperformed 2D thick-slab FSE MRCP in the common bile duct and common hepatic duct (both with p < 0.001), but compared inferiorly in the right anterior hepatic duct (p < 0.001), right posterior hepatic duct (p < 0.005) and pancreatic duct distal (p < 0.05). Performing both 3D and 2D MRCP would reduce the number of non-diagnostic readings in the left hepatic duct to 10 remaining (5.3%), compared with 31 (16.3%) or 21 (11.1%) out of 190 readings if using 3D GRASE or 2D thick-slab FSE alone, respectively.
Although 3D GRASE MRCP is preferential to visualize the common bile duct and common hepatic duct within one single breath-hold, the complementary role of 2D thick-slab FSE MRCP in smaller hepatic and pancreatic ducts makes it a useful adjunct if performed additionally.
en
dc.description.provenanceMade available in DSpace on 2021-06-17T07:14:53Z (GMT). No. of bitstreams: 1
U0001-2612202012031800.pdf: 6605958 bytes, checksum: 680ef152be34ad8fb9d569e393422331 (MD5)
Previous issue date: 2020
en
dc.description.tableofcontents口試委員審定書…………………………………………………………i
誌謝………………………………………………………………………ii
中文摘要…………………………………………………………………iii
Abstract…………………………………………………………………..iv
Contents…………………………………………………………………..v
List of figures…………………………………………………………….vii
List of tables……………………………………………………………..viii
Chapter 1 Introduction ………………………………………………….. 1
Chapter 2 FSE and GRASE sequences …………………………………. 4
2.1 FSE technique for MRCP ………………………………….. 4
2.2 GRASE technique …………………………………………. 7
2.3 Disadvantages of GRASE ………………………………..10
2.4 Unique advantages of GRASE ……………………………11
Chapter 3 Materials and Methods ………………………………………..14
3.1 Subjects …………………………………………………...14
3.2 Image acquisition …………………………………………15
3.3 Performance evaluation …………………………………..18
Chapter 4 Results ………………………………………………………...21
Chapter 5 Discussions and Conclusion …………………………………..29
5.1 Discussion ………………………………………………...29
5.2 Limitation …………………………………………………30
5.3 Conclusion ………………………………………………...34
Appendage ………………………………………………………………..35
Reference …………………………………………………………………38
dc.language.isoen
dc.subject2D厚片取樣zh_TW
dc.subject3D影像zh_TW
dc.subject單一次閉氣zh_TW
dc.subject梯度及自旋回聲zh_TW
dc.subject磁振膽道胰管造影zh_TW
dc.subjectMR cholangiopancreatographyen
dc.subject3D imagingen
dc.subjectbreath-holden
dc.subjectgradient- and spin-echoen
dc.subject2D thick-slab acquisitionen
dc.title3T MRI單次閉氣之膽道胰管磁振造影:比較3D GRASE 及 2D FSE 成像結果
zh_TW
dc.titleMRCP at 3T in a single breath-hold: comparative effectiveness between 3D gradient- and spin-echo and 2D thick-slab fast spin-echo acquisitions
en
dc.typeThesis
dc.date.schoolyear109-1
dc.description.degree博士
dc.contributor.oralexamcommittee李潤川(Run-Chuan Lee),劉昌憲(Chang-Sian Liou),阮春榮(Chun-Jung Juan),黃騰毅(Teng-Yi Huang),林益如(Yi-Ru Lin)
dc.subject.keyword2D厚片取樣,3D影像,單一次閉氣,梯度及自旋回聲,磁振膽道胰管造影,zh_TW
dc.subject.keyword2D thick-slab acquisition,3D imaging,breath-hold,gradient- and spin-echo,MR cholangiopancreatography,en
dc.relation.page43
dc.identifier.doi10.6342/NTU202004465
dc.rights.note有償授權
dc.date.accepted2021-01-06
dc.contributor.author-college電機資訊學院zh_TW
dc.contributor.author-dept生醫電子與資訊學研究所zh_TW
Appears in Collections:生醫電子與資訊學研究所

Files in This Item:
File SizeFormat 
U0001-2612202012031800.pdf
  Restricted Access
6.45 MBAdobe PDF
Show simple item record


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved