請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/68551
標題: 球狀陣列式超音波換能器應用於非侵入式腦部短時間
熱治療之研究
Investigation of spherical ultrasound arrays for noninvasive
short-time brain hyperthermia
作者: Chun-Chiang Shen
沈浚強
指導教授: 林文澧,陳景欣
關鍵字: 超音波,顱骨,超音波熱治療,
ultrasound,skull,hyperthermia,
出版年 : 2017
學位: 碩士
摘要: Abstract
Background:
About 40% of cancer patients develop brain metastasis and it is a major cause of mortality and mobility. Brain metastasis is prevalent in lung cancer, melanoma, and breast cancer. The standard managements of brain metastasis are chemotherapy, radiation therapy and surgery. Therapeutic ultrasound creates a new opportunity to treat brain tumor non-invasively. However skull and blood brain tumor barrier (BTB) are needed to be overcome. In this study, our purpose is to design an ultrasound transducer that can deliver enough energy through skull for short-time brain hyperthermia without damaging normal tissues.
Material and Methods
Rayleigh integral and secondary source model were used to calculate pressure field inside the brain at 1 MHz and 0.5 MHz, and then pressure were used to calculate the temperature distribution and thermal dose to identify treatment area for short-time brain hyperthermia. The transducer was mechanically moved to see the treatment area of 1 MHz home-made transducer for different location. Skull phantom and 42℃ hydrogel were further used to characterize the transducer.
Results
The simulation results showed that the position of peak pressure was slightly offset (<1mm) when the transducer was mechanically moved 3cm in X, Y or Z directions. There was no significant sidelobe when transducer mechanically moved 2cm in all directions. Temperature distribution showed that the shape of heating zone was an ellipsoid (2.2mm*2.3mm*3.9mm) with the temperature beyond 42℃ at a max intensity 119W/cm2 was used. Phantom study showed 42℃ hydrogel would change the color when the transducer was moved ± 2cm in y direction and +2cm in z direction and turned on with an electrical power 55W.
Conclusion:
An 1MHz sphere array transducer could successfully deliver enough energy with a low electrical reflection through skull phantom for short-time brain hyperthermia. The transducer can move ±1, ± 2 cm in x, y and z direction without developing significant side lobes, and the transducer is able to create a local hyperthermia.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/68551
DOI: 10.6342/NTU201703809
全文授權: 有償授權
顯示於系所單位:醫學工程學研究所

文件中的檔案:
檔案 大小格式 
ntu-106-1.pdf
  目前未授權公開取用
7.55 MBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved