請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/61800
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 李百祺 | |
dc.contributor.author | Yi-Ching Ho | en |
dc.contributor.author | 何宜靜 | zh_TW |
dc.date.accessioned | 2021-06-16T13:13:41Z | - |
dc.date.available | 2013-08-06 | |
dc.date.copyright | 2013-08-06 | |
dc.date.issued | 2012 | |
dc.date.submitted | 2013-07-30 | |
dc.identifier.citation | [1]M.O’Donnell, D. Bauwens, J.W. Minbs, and J.G. Miller, “Broadband integrated backscatter: an approach to spatially localized tissue characterization in vivo,” Proc. IEEE Ultrason. Symp., pp. 175–178, Sep. 1979.
[2]J.G. Mottley, and J.G. Miller, “Anisotropy of the ultrasonic attenuation in soft tissues: measurements in vitro,” J. Acoust. Soc. Am., vol. 88, pp. 1203–1210, 1990. [3]B.K. Hoffmeister, A.K. Wong, E.D. Verdonk, and S.A. Wickline, “Comparison of the anisotropy of apparent integrated ultrasonic backscatter from fixed human tendon and fixed human myocardium,” J. Acoust. Soc. Am., vol. 97, pp. 1307–1313, 1995. [4]J.G. Mottley, and J.G. Miller, “Anisotropy of the ultrasonic backscatter of myocardial tissue: I. Theory and measurements in vitro,” J. Acoust. Soc. Am.,, vol. 83, pp. 755-761, 1988. [5]M.O’Donnell, J.W. Mimbs, and J.G. Miller, “Relationship between collagen and ultrasonic backscatter in myocardial tissue,” J. Acoust. Soc. Am., vol. 69, pp. 580-588, 1981. [6]S.A. Wickline, “Identification of human myocardial infarction in vitro based on the frequency dependence of ultrasonic backscatter,” J. Acoust. Soc. Am., vol. 91, pp. 3018-25, 1992. [7]A.K. Wong, “Detection of unique transmural architecture of human idiopathic cardiomyopathy by ultrasonic tissue characterization,” Circulation, vol. 86, pp. 1108-1115, Oct. 1992. [8]C.T. Nguyen, “Age-related alterations of cardiac tissue microstructure and material properties in Fischer 344 rats,” Ultrasound Med. Biol., vol. 27, pp. 611-619, May. 2001. [9]http://link.springer.com/content/pdf/10.1007%2F0-387-22825-X_6.pdf [10]S.A. Wickline, “A relationship between ultrasonic integrated backscatter and myocardial contractile function,” J. Clin. Invest., vol. 76, pp. 2151-2160, Dec. 1985. [11]http://www.alkutnet.com/vb/showthread.php/23930-connective-tissue [12]F.H. Silver, J.W. Freeman, and G.P. Seehra, “Collagen self-assembly and the development of tendon mechanical properties,” J. Biomech., vol. 36, pp. 1529–1553, Oct. 2003. [13]J.H. Rose, “A proposed microscopic elastic wave theory for ultrasonic backscatter from myocardial tissue,” J. Acoust. Soc. Am., vol. 97, pp. 656-668, 1995. [14]M.R. Holland, et al., “Effects of myocardial fiber orientation in echocardiography: quantitative measurements and computer simulation of the regional dependence of backscattered ultrasound in the parasternal short-axis view,” J. Am. Soc. Echocardiogr., vol. 11, pp. 929-937,Oct. 1998. [15]http://uw.physics.wisc.edu/~timbie/P325/Spike_photoacoustic_effect.pdf [16]P. Beard, “Biomedical photoacoustic imaging,” Interface focus, vol. 1, pp. 602–31, Aug. 2011. [17]C.W. Hsu, “Glucose concentration measurements utilizing a photoacoustic technique,” National Taiwan University, 2006. [18]T. Hiro, C.Y. Leung, H. Karimi, and J. M. Tobis, “Angle dependence of intravascular ultrasound imaging and its feasibility in tissue characterization of human atherosclerotic tissue,” Amer. Heart J., vol. 137, pp. 476–481, Mar. 1999. [19]S. Sethuraman, S.R. Aglyamov, J.H. Amirian, R.W. Smalling, and S.Y. Emelianov, “Intravascular photoacoustic imaging using an IVUS imaging catheter.,” IEEE tran. Ultra. Ferroelec. Freq. Con., vol. 54, pp. 978–86, May 2007. [20]S. Sethuraman, S.R. Aglyamov, J.H. Amirian, R.W. Smalling, and S.Y. Emelianov, “Spectroscopic intravascular photoacoustic imaging to differentiate atherosclerotic plaques,” Optics express, vol. 16, pp. 3362–3367, Mar. 2008. [21]P.H. Wang, J.J. Luh, W.S. Chen, and M.L. Li, “In vivo photoacoustic micro-imaging of microvascular changes for Achilles tendon injury on a mouse model,” Biomed. opt. exp., vol. 2, pp. 1462–1469, Jun. 2011. [22]X. Wang, Y. Pang, G. Ku, X. Xie, G. Stoica, and L.V Wang, “Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain,” Nat. Biotech., vol. 21, pp. 803–806, Jul. 2003. [23]S.K. Rathore, P.Munshi, and N.N. Kishore, “A new tomographic reconstruction method for anisotropic materials,” Nondes. Test. Eva., vol. 18, pp. 171–182, Sep. 2002. [24]R.A. Kline and Y.Q. Wang, “A technique for ultrasonic tomography in anisotropic media,” J. Acoust. Soc. Am., vol. 91, pp. 878–884, 1992. [25]G.H. Brandenburger, J.R. Klepper, J.B. Miller, and D.L. Synder, “Effects of Anisotropy in the Ultrasonic Attenuation of Tissue on Computed Tomography,” Ultrason. Imag., vol. 3, pp. 113–143, 1981. [26]J.R. Klepper, G.H. Brandenburger, J.W. Mimbs, B.E. Sobel, and J.G. Miller, “Application of phase-insensitive detection and frequency-dependent measurements to computed ultrasonic attenuation tomography,” IEEE tran. biomed. eng., vol. 28, pp. 186–201, Feb. 1981. [27]L.V Wang, “Multiscale photoacoustic microscopy and computed tomography,” Nature photonics, vol. 3, pp. 503–509, Aug. 2009. [28]A. Ishimaru, Wave propagation and scattering in random media, New York: Academic, 1978. [29]L.V. Wang, Photoacoustic imaging and spectroscopy, Boca Raton: CRC Press, 2009. [30]A. Charalambopoulos and G. Dassios, “Scattering of a spherical wave by a small ellipsoid,” IMA J. Appl. Math., vol. 62, pp. 117–136, 1999. [31]Y.L. Sheu and P.C. Li, “Simulations of photoacoustic wave propagation using a finite-difference time-domain method with Berenger’s perfectly matched layers,” J. Acoust. Soc. Amer., vol. 124, pp. 3471–3480, Dec. 2008. [32]Y.L. Sheu and P.C. Li, “Simulations of thermally induced photoacoustic wave propagation using a pseudospectral time-domain method,” IEEE Tran. Ultrason.Ferro.Freq. Cont., vol. 56, pp. 1104–12, May 2009. [33]B.E. Treeby and B.T. Cox, “k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields.,” J. Biomed. opt., vol. 15, pp. 021314, Mar. 2013. [34]A. Papoulis, The Fourier integral and its applications, New York: McGraw-Hill, pp. 198–212, 1962. [35]Y.L. Sheu, Y.C. Ho, P.C. Li, “Acoustic and photoacoustic scattering from transverse isotropic tissues,” Proc. SPIE, Photons Ultra: Imag. Sens., vol. 8581, pp. 85814C-85814C, 2013. [36]H. Rijsterborgh, F. Mastik, C.T. Lancee, P. verdouw, J. roelandt, N. Bom, “Ultrasound myocardial integrated backscatter signal processing:frequency domain versus time domain,” Ultra. Med. & Biol., vol. 19, pp. 211–219, 1993. [37]P.C. Li, C.W. Wei and Y.L. Sheu, “Subband photoacoustic imaging for contrast improvement,” Optics Express, vol. 16, pp. 20215–20226, Dec. 2008. [38]S. Manohar, G.H. Willemink, “Concomitant speed-of-sound tomography in photoacoustic imaging,” Appl. Phys. Lett., vol. 91, pp. 131911, Apr. 2007. [39]X. Wang, Y. Xu and L.V. Wang, “Photoacoustic tomography of biological tissues with high cross-section resolution: reconstruction and experiment,” Med. Phys., vol. 29, pp. 2799-2805, Sep. 2002. [40]http://www.medison.ru/uzi/eng/all/cardio.htm [41]http://www.msdlatinamerica.com/ebooks/CoreCurriculumTheUltrasound/sid102252.html [42]Y.L. Sheu, C.Y. Chou, B.Y. Hsieh, and P.C. Li, “Image reconstruction in intravascular photoacoustic imaging,” IEEE Tran. Ultra. Ferroelec. Freq. Con., vol. 58, pp. 2067-2077, Oct., 2011. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/61800 | - |
dc.description.abstract | 聲波傳遞方向與纖維性組織走向對於超音波散射有相當大的關聯性,纖維性組織像是肌腱、肌肉、神經皆有此特性,對於傳統的超音波B-mode影像會造成亮暗不均勻的現象造成醫師診斷的困難。本研究比較超音波與光聲現象對於纖維性組織的散射特性。我們使用肌腱做為實驗樣本,並使用許多文獻提出的參數積分散射值(AIB) 來計算超音波散射能量,實驗結果也證實非等向性組織排列與超音波傳遞方向夾角的改變的確對探頭收到的能量改變有相當大的關聯性。量測結果顯示能量改變隨著不同的纖維排列方向與探頭夾角改變有一定的規則性,在纖維方向與探頭方向垂直時,散射能量最大,而在平行時,散射能量則最小。我們定義由聲波與纖維走向垂直至平行的能量差異值稱作最大能量衰減,實驗結果顯示高頻聲波會造成較大的能量衰減,另外比較超音波和光聲波的實驗結果,我們發現光聲波傳遞方向較不受纖維性組織排列方向影響。因此我們提出一個假說來解釋超音波和光聲波對於纖維性組織會有不同能量衰減幅度的原因。以探頭產生的超音波面積遠大於組織散射子,對於散射子類似為平面波,對排列整齊的散射子造成等方向的散射,相同方向加成的結果造成散射波在不同方向有不同大小的振幅;相對的,光聲波由光纖產生熱膨脹接著產生聲波,產生聲波是以類似球面波的方向傳遞,造成傳遞方向對於每個散射子相關性低,相互抵銷的結果造成光聲波對於組織排列較不敏感,我們同時以實驗和模擬驗證這個假說。因此從此項發現我們推測光聲影像在纖維性組織上的診斷也許會比傳統超音波影像診斷更有優勢。 | zh_TW |
dc.description.abstract | Anisotropy of ultrasound scattering in fibrous tissue depends on the specific direction of transducer with respect to the fiber orientation. The uneven brightness displayed on an ultrasound B-mode image depends on tissue fiber orientation, which causes difficulties in diagnosis. This study is aimed to investigate both the ultrasonic and photoacoustic wave scattering in anisotropic tissues. Tendon samples were used, and results showed that the apparent integrated scatter (AIS) from fibrous tissues was highly dependent on the angle of insonification. The energy scattered from tendon exhibited maximum scatter intensity when the direction of transducer was perpendicular to the fibers, and minimum scatter intensity for parallel incidence. The results show that higher detection frequency resulted in a larger maximum AIS decrement from perpendicular to parallel direction. Furthermore, significant angular dependence of ultrasound scattering was observed in the measurements as compared to photoacoustic scattering, which is less sensitive to the fiber orientation. A hypothesis is proposed to explain why photoacoustic waves are relatively less affected by the fibrous tissue. In ultrasonic scattering, incident direction for each scatterer was similar due to the relatively planar wavefront, hence the signal amplitudes scattered at the transducer direction are also similar. In photoacoustic scattering, the spherical-like wavefront causes different incident directions for different scatterers, therefore the variation of the signal amplitude collected by the transducer increases, resulting in a lower correlation with the microstructure. The smaller angular dependence in photoacoustic scattering implies that photoacoustic imaging may have the advantage to be applied to image anisotropic tissue. | en |
dc.description.provenance | Made available in DSpace on 2021-06-16T13:13:41Z (GMT). No. of bitstreams: 1 ntu-101-R00945009-1.pdf: 2629234 bytes, checksum: d43e0e3ca7c73a1304d10d0879437e3e (MD5) Previous issue date: 2012 | en |
dc.description.tableofcontents | 致謝I
中文摘要 II ABSTRACT III 目錄 IV 圖目錄 VI 表目錄 VIII CHAPTER 1. 緒論 1 1.1. 研究動機 1 1.2. 非等向組織特性 1 1.2.1. 超音波心肌特性分析 2 1.2.2. 超音波背向散射在心肌上的應用 3 1.2.3. 臨床心肌特性分析 4 1.2.4. 肌腱的結構 6 1.2.5. 非等向性散射 7 1.3. 光聲效應簡介 9 1.3.1. 光聲效應原理 9 1.3.2. 光聲訊號接受方式 11 1.4. 研究目標 12 1.5. 論文架構 13 CHAPTER 2. 非等向性組織對醫學影像的影響 14 2.1. 超音波影像 14 2.1.1. 血管內造影 14 2.1.2. 超音波斷層掃描 15 2.2. 光聲影像 16 2.2.1. 血管內造影 16 2.2.2. 光聲斷層掃描 17 2.2.3. 非等向組織在光聲影像的應用 18 CHAPTER 3. 實驗架構與方法 19 3.1. 理論方法 19 3.2. 訊號分析 22 3.3. 非等向性組織與仿體實驗 24 3.3.1. 碳纖維仿體製作 24 3.3.2. 旋轉探頭方式 24 3.3.3. 旋轉樣本方式 25 3.4. 平面波與球面波假說驗證 26 3.5. 超音波斷層掃描的非等向性現象 28 CHAPTER 4. 結果與分析 30 4.1. 理論模擬結果 30 4.2. 旋轉探頭方式 31 4.3. 旋轉樣本方式 32 4.3.1. 時域與頻域分析 32 4.3.1. 訊雜比分析 36 4.3.2. 不同中心頻率 38 4.3.3. 驗證 42 4.4. 超音波斷層掃描模擬 44 CHAPTER 5. 討論與結論 47 5.1. 影響最大能量衰減幅度大小的原因 47 5.1.1. 實驗上的誤差 47 5.1.2. 模擬上的誤差 48 5.2. 頻域分析的優勢 49 5.3. 驗證 51 5.3.1. 三種驗證實驗的討論 51 5.3.2. 陣列探頭聚焦/非聚焦 52 5.4. 超音波/光聲成像深度 53 5.4.1. 肌腱的超音波/光聲影像 53 5.4.2. 影響影像深度的原因 55 5.5. 非等向性對斷層掃描影像的影響 57 5.5.1. 平面波/球面波源斷層掃描比較 57 5.5.2. 非等向性對超音波/光聲斷層掃描的影響 60 5.6. 比較超音波與光聲訊號積分散射值的應用 61 5.7. 未來工作 62 參考資料 63 | |
dc.language.iso | zh-TW | |
dc.title | 超音波與光聲波在纖維性組織中的非均勻散射現象 | zh_TW |
dc.title | Anisotropy of ultrasonic scattering and photoacoustic signal generation from fibrous tissues | en |
dc.type | Thesis | |
dc.date.schoolyear | 101-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 郭柏齡,沈哲州,宋孔彬,周呈霙 | |
dc.subject.keyword | 超音波,光聲效應,非等向性,散射,纖維性組織, | zh_TW |
dc.subject.keyword | ultrasound,photoacoustic effect,anisotropy,scattering,fibrous tissue, | en |
dc.relation.page | 66 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2013-07-30 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 生醫電子與資訊學研究所 | zh_TW |
顯示於系所單位: | 生醫電子與資訊學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-101-1.pdf 目前未授權公開取用 | 2.57 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。