請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/60327
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 李百祺(Pai-Chi Li) | |
dc.contributor.author | Yu-Hsin Wang | en |
dc.contributor.author | 王昱欣 | zh_TW |
dc.date.accessioned | 2021-06-16T10:15:37Z | - |
dc.date.available | 2018-09-06 | |
dc.date.copyright | 2013-09-06 | |
dc.date.issued | 2013 | |
dc.date.submitted | 2013-08-19 | |
dc.identifier.citation | [1] S. R. Cherry, “Multimodality in vivo imaging systems: Twice the power or double the trouble?,” Annu. Rev. Biomed. Eng., 8, 35–62 (2006).
[2] A. C. Tam, “Applications of photoacoustic sensing techniques,” Rev. Mod. Phy., 58(2), 381–431 (1986). [3] A. G. Bell, “Production of sound by radiant energy,” Manufacturer and builder, 13(7), 156–158 (1881). [4] R. M. White, “Elastic wave generation by electron bombardment or electromagnetic wave absorption,” J. App. Phys., 34(7), 2123–2134 (1963). [5] C. K. N. Patel, E. G. Burkhardt, C. A. Lambert, “Spectroscopic measurements of stratospheric nitric oxide and water vapor,” Science, 184(4142), 1173–1176 (1974). [6] C. Haisch and R. Niessner, “Light and sound–Photoacoustic spectroscopy,” Spectroscopy Europe, 14(5), 10–15 (2002). [7] A. Elia, C. Francoemail, P. M. Lugaraemail, and G. Scamarcioemail., “Photoacoustic spectroscopy with quantum cascade lasers for trace gas detection,” Sensors, 6, 1411–1419 (2006). [8] A. Petzold and R. Niessner, “Photoacoustic soot sensor for in-situ black carbon monitoring,” Appl. Phys. B., 63(2), 191–197 (1996). [9] I. Carrer, P. Cusmai, E. Zanzottera, W. Martinotti, and F. Realini, “Application of photoacoustic spectrometry to flow-injection analysis,” Anal. Chim. Acta., 308(1–3), 20–27 (1995). [10] T. Schmid, C. Helmbrecht, C. Haisch, U. Panne U, and R. Niessner, “On-line monitoring of opaque liquids by photoacoustic spectroscopy,” Anal. Bioanal. Chem., 375(8), 1130–1135 (2003). [11] W. Schrepp, R. Stumpe, J. I. Kim, and H. Walther, “Oxidation-state-specific detection of uranium in aqueous solution by photoacoustic spectroscopy,” Appl. Phys. B, 32 (4), 207–209 (1983). [12] A. N. Vasil'ev, V. A. Sablikov, and V. B. Sandomirskii, “Photothermal and photoacoustic effects in semiconductors and semiconductor structures,” Russ. Phys. J., 30(6), 544–554 (1987). [13] M. Maliński, J. Zakrzewski and F. Firszt, “Photoacoustic spectroscopy of surface defects states of semiconductor samples,” E. P. J., 153(1), 251–254(2008). [14] M. Xu and L.V. Wang, “Photoacoustic imaging in biomedicine,” Rev. Sci. Instrum., 77(4), 041101s (2006). [15] A. A. Karabutov, N. B. Podymova, V. S. Letokhov, “Time-resolved laser optoacoustic tomography of inhomogeneous media,” Appl. Phys. B, 63, 545–563 (1996). [16] A. D. Pierce, “Acoustics: An introduction to its physical principles and applications,” Acoustical Soc of America, New York, 1989. [17] V. E. Gusev, A. A. Karabutov, “Laser Optoacoustics,”, American institute of physics, New York, 1993 . [18] T. J. Allen, B. T. Cox, and P. C. Beard, “Generating photoacoustic signals using high-peak power pulsed laser diodes,” in Proc. of SPIE, 5697, 233–242 (2005). [19] Z. M. Zhao., et. al., “Production and detection theory of pulsed photoacoustic wave with maximum amplitude and minimum distortion in bbsorbing liquid,” IEEE Trans. Instrum. Meas., 47(2), 578–583 (1998). [20] C. G. A. Hoelen and F. F. M. de Mul, “A new theoretical approach to photoacoustic signal generation,”. J. Acoust. Soc. Am., 106(2), 695–706 (1999). [21] R.G. Kolkman, J. H. Klaessens, E. Hondebrink, J. C. Hopman, F. F. de Mul, W. Steenbergen, J. M. Thijssen, and T. G. van Leeuwen, “Photoacoustic determination of blood vessel diameter,” Phys. Med. Biol., 49(20), 4745–4756 (2004). [22] J. Jose, S. Manohar, R. G. Kolkman, W. Steenbergen, and T. G. van Leeuwen, “Imaging of tumor vasculature using Twente photoacoustic systems,” J. Biophotonics, 2(12), 701–717 (2009). [23] Z. M. Zhao and R. Myllyla, “The Effects of optical scattering on pulsed photoacoustic measurement in weakly absorbing liquids,” Meas Sci Technol., 12(2), 2172–2177 (2001). [24] E. L. Madsen, J. A. Zagzebski, R. A. Banjavie, R. E. Jutila., “Tissue mimicking materials for ultrasound phantoms,” Med. Phys., 5(5), 391–394 (1978). [25] P. C. Beared and B. Cox, “Modeling Photoacoustic propagation in tissue using k-space techniques”, in Wang, L. V. (Ed.), Photocoustic imaging and spectroscopy, CRC Press, London, 25–34 (2009). [26] J. R. Cook, R. R. Bouchard, and S. Y. Emelianov, “Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging,” Biomed. Opt. Express, 2(11), 3193–3206 (2011). [27] K. F. Ustuner and G. L. Holley, “Ultrasound imaging system performance assessment,“ AAPM 45th Annual Meeting, Aug. 10–14 (2003) [28] R. O. Esenaliev, A. A. Karabutov, and A. A. Oraevsky, “Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors,” IEEE J. Sel. Top. Quantum electron., 5(4), 981–988 (1999). [29] C. H. Li and L. V. Wang, “Photoacoustic tomography and sensing in biomedicine,” Phys. Med. Biol., 54, R59–R97 (2009). [30] P. Beard, “Biomedical photoacoustic imaging,” Interface Focus, 1, 602–631 (2011). [31] F. Kong, Y. C. Chen, H. O. Lloyd, R. H. Silverman, H. H. Kim, J. M. Cannata, and K. K. Shung, “High-resolution photoacoustic imaging with focused laser and ultrasonic beams,” Appl. Phys. Lett., 94(3), 033902 (2009). [32] R. G. M. Kolkman, E. Hondebrink, W. Steenbergen, and F.F.M. de Mul, “In vivo photoacoustic imaging of blood vessels using an extreme-narrow apeture sensor,” IEEE J. Sel. Top. Quantum Electron., 9(2), 343–346(2003). [33] H. F. Zhang, K. Maslov, G. Stoica, and L. V. Wang, “Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging,” Nat. biotechnol., 24(7), 848–851 (2006). [34] H. F. Zhang, K. Maslov, and L. V. Wang, “In vivo imaging of subcutaneous structures using functional photoacoustic microscopy,” Nat. Protocols, 2(4):797–804 (2007). [35] D. W. Yang, D. Xing, S. H. Yang, and L. Z. Xiang, “Fast full-view photoacoustic imaging by combined scanning with a linear transducer array,” Opt. Express, 15(23),15566–15575 (2007). [36] R. J. Zemp, L. Song, R. Bitton, K. K. Shung, and L. V. Wang, “Realtime photoacoustic microscopy in vivo with a 30-MHz ultrasound array transducer,” Opt. Express, 16(11), 7915–7928 (2008). [37] B. Rao, et al., “Real-time four-dimensional optical-resolution photoacoustic microscopy with Au-nanoparticle assisted sub-diffraction-limit resolution,” Opt. Letters, 36(7), 1137–1139 (2011). [38] Y. Jiang, T. Harrison, J. Ranasinghesagara, and R. J. Zemp, “Photoacoustic and high-frequency power Doppler ultrasound biomicroscopy: a comparative study,” J Biomed Opt., 15(5), 056008 (2010). [39] S. Park, et al., “Integrated system for ultrasonic, photoacoustic and elasticity imaging,” in Proc. of the SPIE, 6147, 148–155 (2006). [40] C. H. Seo and S. J. T. Yen “Sidelobe suppression in ultrasound imaging using dual apodization with cross-correlation,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 55 (10), 2198–2210 (2008). [41] D . A. Guenther and W. F. Walker, “Optimal apodization design for medical ultrasound using constrained least squares Part I: Theory,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 54 (2), 332–342 (2007). [42] J. F. Synnevag, A. Austeng, and S. Holm, “A low-complexity data-dependent beamformer,” IEEE Trans Ultrason Ferroelectr Freq Control., 58(2):281–289(2011). [43] J. Capon, “High-resolution frequency-wavenumber spectrum anaylsis,” in Proc. IEEE, 57(8), 1408–1418 (1969). [44] I.K. Holfort, F. Gran, and J. A.Jensen, “Broadband minimum variance beamforming for ultrasound imaging,” IEEE Trans Ultrason Ferroelectr Freq Control., 56(2), 314–325(2009). [45] B. M. Asl and A. Mahloojifar, “Minimum variance beamforming combined with adaptive coherence weighting applied to medical ultrasound imaging,” IEEE Trans Ultrason Ferroelectr Freq Control., 56(9), 1923–1931 (2009). [46] K. Maslov, H. F. Zhang, S. Hu, and L. V. Wang, “Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries,” Opt. Letters, 33(9), 929–931 (2008) [47] S. Hu, K. Maslov, V. Tsytsarev, and L. V. Wang, “Functional transcranial brain imaging by optical-resolution photoacoustic microscopy,” J. Biomed. Opt., 14(4), 040503 (2009). [48] G. P. Luke, D. Yeager D, and S. Y. Emelianov, “Biomedical applications of photoacoustic imaging with exogenous contrast agents,” Ann. Biomed. Eng., 40(2), 422–437(2012).. [49] G. Kim, et al., “Indocyanine-green-embedded PEBBLEs as a contrast agent for photoacoustic imaging,” J. Biomed. Opt., 12(4), 044020–044028(2007). [50] G. Ku and L V. Wang, “Deeply penetrating photoacoustic tomography in biological tissues enhanced with an optical contrast agent,” Opt. Letters, 30(5), 507–509 (2005). [51] X. Wang, et al, “Noninvasive photoacoustic angiography of animal brains in vivo with near-infrared light and an optical contrast agent,” Opt. Letters, 29(7), 730–732(2004). [52] K. H. Song, E. W. Stein, J. A. Margenthaler JA, and L. V. Wang, “Noninvasive photoacoustic identification of sentinel lymph nodes containing methylene blue in vivo in a rat model,” J. Biomed. Opt., 13(5), 054033–054036 (2008). [53] S. Ashkenazi, “Photoacoustic lifetime imaging of dissolved oxygen using methylene blue,” J. Biomed. Opt. Letters, 15(4), 040501s (2010). [54] X. Yang, E. W. Stein, S. Ashkenazi, and L. V. Wang, “Nanoparticles for photoacoustic imaging,” Wiley Interdiscip. Rev. Nanomed. Nanobiotechnol., 1(4), 360–368 (2009). [55] Q. Zhang, et al., “Gold nanoparticles as a contrast agent for in vivo tumor imaging with photoacoustic tomography,” Nanotechnol., 20(39), 395102 (2009). [56] K. Greish, “Enhanced permeability and retention of macromolecular drugs in solid tumors: a royal gate for targeted anticancer nanomedicines,” J. Drug Target., 15(7–8), 457–464 (2007). [57] J. E. Millstone, “Colloidal gold and silver triangular nanoprisms,” Small, 5(6), 646–64 (2009). [58] Y. Cheng, et al., “Highly efficient drug delivery with gold nanoparticle vectors for in vivo photodynamic therapy of cancer,” J. Am. Chem. Soc., 130 (32), 10643–10647 (2008). [59] D. S. M. Valenzuela and M. B. Cortie, “Therapeutic possibilities of plasmonically heated gold nanoparticles,” Trend Biotechnol., 24(2), 62–67 (2006). [60] J. J. Niederhauser, M Jaeger M, and M. Frenz, “Real-time three-dimensional optoacoustic imaging using an acoustic lens system,” Appl Phy Lett 85, 846–848 (2004). [61] S. Vaithilingam, et al., “Three-dimensional photoacoustic imaging using a two-dimensional CMUT array,” IEEE Trans Ultrason Ferroelec Freq Contr, 56, 2411–2419 (2009). [62] P. Ephrat, M. Roumeliotis, F. S. Prato, and J. J. Carson, “Four-dimensional photoacoustic imaging of moving targets,” Opt. Express, 16, 21570–21581 (2008). [63] C.-K. Liao, S.-W. Huang, C.-W. Wei, and P.-C. Li., “Nanorod-based flow estimation using a high-frame-rate photoacoustic imaging system,” J. Biomed. Opt., 12, 064006–064009 (2007). [64] R. Olafsson, L. Montilla, P. Ingram, and R. S. Witte., “Tracking contrast agents using real-time 2D photoacoustic imaging system for cardiac applications,” in Proc SPIE, 7177, 71771R (2009). [65] X Wang, J. B. Fowlkes, P. L. Carson, and L. Mo, “Experimental evaluation of a high-speed photoacoustic tomography system based on a commercial ultrasound unit,” in Proc. IEEE Ultrasonics Symp, 1234–1237 (2008). [66] L. Song, K. Maslov, R. Bitton, K. K. Shung, and L. V. Wang., “Fast 3D dark-field reflection-mode photoacoustic microscopy in vivo with a 30 MHz ultrasound linear array,” J. Biomed. Opt., 13, 054028 (2008). [67] L. Song, C. Kim, K. Maslov, K. K. Shung, and L. V. Wang., “High-speed dynamic 3D photoacoustic imaging of sentinel lymph node in a murine model using an ultrasound array,” Med. Phys., 36, 3724–3728 (2009). [68] L. Song, K. Maslov, and L. V. Wang, “Section-illumination photoacoustic microscopy for dynamic 3D imaging of microcirculation in vivo,” Opt. Letters, 15, 1482–1484 (2010). [69] C. H. Frazier and W. R. O'Brien, “Synthetic aperture technique with a virtual source element,” IEEE Trans Ultrason. Ferroelectr. Freq. Contr, 45, 196–207 (1998). [70] C. K. Liao, M. L. Li, and P. C.Li, “Optoacoustic imaging with synthetic aperture focusing and coherence weighting,” Opt. Letters, 29, 2506–2508 (2004). [71] S. I. Nikolov and J. A. Jensen, “3D synthetic aperture imaging using a virtual source element in the elevation plane,” in Proc IEEE Ultrasonics Symp, 1743–1747 (2000). [72] J. H. Liu, et al., “Design, fabrication, and testing of a dual-band photoacoustic transducer,” Ultrason. Imag., 30, 217–227 (2008). [73] R. Bitton, R. Zemp, J. Yen, L. V. Wang, and K. K. Shung, “A 3D high frequency array based 16 channel photoacoustic microscopy system for in vivo microvascular imaging,” IEEE Trans Med Imaging, 28, 1190–1197 (2009). [74] E. Cherin, et al., “Ultrahigh frame rate retrospective ultrasound microimaging and blood flow visualization in mice in vivo,” Ultrasound Med. Biol., 32(5), 683–691 (2006). [75] J. Bercoff, S. Chaffai, M. Tanter, and M. Fink, “Ultrafast imaging of beamformed shear waves induced by the acoustic radiation force in soft tissues. Application to transient elastography,” in Proc. IEEE Ultrason. Symp., 1899–1902 (2002). [76] S.I. Nilolov and J.A. Jensen, “In-vivo synthetic aperture flow imaging in medical ultrasound,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr., 50(7), 848–856 (2003). [77] S.-Y Wu, S.-L. Wang, P.-C. Li, “Tracking in high-frame rate imaging,” Ultrason. Imaging, 32(1), 1–15 (2010). [78] J. Bercoff, et al., “In vivo breast tumors detection using transient elastography,” Ultrasound Med. Biol., 29(10), 1387–1396 (2003) [79] G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, “Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography,” IEEE Trans. Ultrason. Ferroelec. Freq. Contr. , 56(3), 489–506 (2009). [80] S. I. Nikolov, J. Kortbek, and J. A. Jensen, “Practical applications of synthetic aperture imaging,” in Proc. IEEE Ultrason. Symp., 350–358 (2010). [81] J. A. Jensen, S. I. Nikolov, K. L. Gammelmark, M. H. Pedersen, “Synthetic aperture ultrasound imaging,” Ultrasonics, 44, e5–e15 (2006). [82] K.L. Gammelmark, J.A. Jensen, “Multielement synthetic transmit aperture imaging using temporal encoding,” IEEE Trans. Med. Imag., 22(4), 552–563 (2003). [83] I, K. Holfort, F. Gran, and J. A. Jensen, “Minimum variance beamforming for high frame-rate ultrasound imaging,” in Proc. IEEE Ultrason. Symp., 1541–1544(2007). [84] J. F. Synnevag, A. Austeng, and S. Holm, “Adaptive beamforming applied to medical ultrasound imaging,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 54(8), 1606–1613 (2007). [85] S.-L. Wang and P.-C. Li, “MVDR-based coherence weighting high-frame-rate adaptive Imaging,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 56(10), 2097–2110 (2009). [86] J. F. Synnevag, A. Austeng, and S. Holm, “Benefits of minimum-variance beamforming in medical ultrasound imaging,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 56(9), 1868–1879 (2009). [87] F. Vignon and M. R. Burcher, “Capon beamforming in medical ultrasound imaging with focused beams,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 55(3), 619–628 (2008). [88] K. W. Hollman, K. W. Rigby, and M. O’Donnell, “Coherence factor of speckle from a multi-row probe,” in Proc. IEEE Ultrason. Symp., 1257–1260 (1999). [89] P.-C. Li and M.-L. Li, “Adaptive imaging using the generalized coherence factor,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 50(2), 128–141 (2003). [90] S. Park, A. B. Karpiouk, S. R. Aglyamov, and S. Y. Emelianov, “Adaptive beamforming for photoacoustic imaging,” Opt. Lett., 33(12), 1291–1293 (2008). [91] C.-I. C. Nilsen and S. Holm, “Wiener beamforming and coherence factor in ultrasound imaging,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 57(6), 1329–1346 (2010). [92] K. U. Simmer, J. Bitzer and C. Marro, “Post-filtering techniques,” in Microphone Array: Signal Processing Techniques and Applications, M. S. Brandstein and D. B. Ward, Eds., Springer-Verlag, 39–57 (2001). [93] J. Chen, J. Benesty, Y. Huang, and S. Doclo, “New insights into the noise reduction Wiener filter,” IEEE Trans. Audio, Speech, Lang. Process., 14(4), 1218–1234 (2006). [94] C. Kim, T. N. Erpelding, L. Jankovic, M. D. Pashley, and L. V. Wang, “Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system,” Biomed. Opt. Exp., 1(1), 278–284 (2010). [95] C. Kim, et al., “Handheld array-based photoacoustic probe for guiding needle biopsy of sentinel lymph nodes,” J. Biomed. Opt., 15 (4), 046010 (2010). [96] T. Harrison and R. J. Zemp, “The applicability of ultrasound dynamic receive beamformers to photoacoustic imaging,” IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 58 (10), 2259–2263 (2011). [97] C.-K. Liao, M.-L. Li, and P.-C. Li, “Optoacoustic imaging with synthetic aperture focusing and coherence weighting,” Opt. Lett., 29(21), 2506–2508 (2004). [98] “American National Standard for the Safe Use of Lasers in Health Care Facilities: Standard Z136.1-2000,” A. N. S. Institute, Ed. ANSI, Inc., New York, 2000. [99] J. Benesty and J. Chen, Optimal time-domain noise reduction filters: a theoretical study. New York: Springer, 43–59 (2011). [100] H. L. Van Trees, Detection, Estimation, and Modulation Theory, Part IV: Optimum Array Processing. New York: Wiley (2003). [101] H. Yoon and H. Ko, “Microphone array post-filter using input-output ratio of beamformer noise power spectrum,” Electron. Lett., 43 (18), 1003–1005 (2007). [102] Y.-H. Wang and P.-C. Li, “Ultrafast photoacoustic imaging and its application to real-time 3D imaging with improved focusing,” Ultrason. Imag., 33(3), 189–196 (2011). [103] K. M. Abadir and J. R. Magnus, Matrix Algebra. Cambridge University Press, 321–350, (2002). [104] R. Zelinski, “A microphone array with adaptive post-filtering for noise reduction in reverberat rooms,” in Proc. 13th IEEE Intnat. Conf. Acoust. Speech Signal Process., ICASSP-88, 2578–2581 (1988). [105] I. A. McCowan and H. Bourlard, “Microphone array post-filter based on noise field coherence,” IEEE Trans. SAP, 11(6), 709–716 (2003). [106] K. U. Simmer and A. Wasiljeff, “Adaptive microphone arrays for noise suppression in the frequency domain,” in Proc. 2nd Cost-229 Workshop on Adaptive algorithms in Communications, 185–194 (1992). [107] S.-L.Wang, C.-H. Chang, H.-C Yang, Y.-H. Chou YH, P.-C Li, “Performance evaluation of coherence-based adaptive imaging using clinical breast data,” IEEE Trans. Ultrason Ferroelectr Freq Control., 54(8), 1669–1679 (2007). [108] D. R. Van Rheeden and S. C. Gupta, “A temporal smoothing approach to direction of arrival estimation of coherent signals in fading channels,” in Proc. IEEE WCNC, 286–890 (1999). [109] T. J. Shan, M. Wax, and T. Kailath, “On spatial smoothing for direction-of-arrival estimation of coherent signals,” IEEE Trans. Acoust. Speech Signal Process., 33(4), 806–811 (1985). [110] J. A. Jensen, “Field: a program for simulating ultrasound system,” Med. Biol. Eng. Comp., 4, suppl. 1, pt. 1, 351–353 (1996). [111] R. R. Nadakuditi and A. Edelman, “The bias of the MVDR beamformer outputs under diagonal loading,' in Proc. IEEE Acoustics, Speech, and Signal Processing, iv/793–iv/796 (2005). [112] J. F. Synnevag, C. I. C. Nilsen, and S. Holm, “Speckle statistics in adaptive beamforming,” in Proc. IEEE Ultrasonics Symp., 1545–1548 (2007). [113] P. C. Li, et al., “In vivo photoacoustic molecular imaging with simultaneous multiple selective targeting using antibody-conjugated gold nanorods,” Opt. Express, 16(23), 18605–18615 (2008). [114] K. Ferrara, R. Pollard, and M. Borden, “Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery,” Annu. Rev. Biomed. Eng., 9, 415–447 (2007). [115] K. Wilson, K. Homan, and S. Emelianov, “Biomedical photoacoustics beyond thermal expansion using triggered nanodroplet vaporization for contrast-enhanced imaging.,” Nat. Commun, 3, 618 (2012). [116] C. Kim, R. Qin, J. S. Xu, L. V. Wang, R. Xu, “Multifunctional microbubbles and nanobubbles for photoacoustic and ultrasound imaging,” J. Biomed. Opt., 15(1), 010510 (2010). [117] W. G. Pitt, G. A. Husseini, and B. J. Staples, “Ultrasonic drug delivery–a general review,” Expert Opin. Drug Deliv., 1(1), 37–56 (2004). [118] S. Paliwal and S. Mitragotri, “Ultrasound-induced cavitation: applications in drug and gene delivery,” Expert Opin. Drug Deliv., 3(6), 713–726 (2006). [119] A. F. H. Lum, et al., “Ultrasound radiation force enables targeted deposition of model drug carriers loaded on microbubbles,” J. Control. Release, 111(1-2), 128–134 (2006). [120] X. Huang, I. H. El-Sayed, W. Qian, M. A. El-Sayed, “Cancer cell imaging and photothermal therapy in near-infrared region by using gold nanorods,” J. Am. Chem. Soc., 128(6), 2115–2120 (2006). [121] R. O. Esenaliev, A. A. Oraevsky, K. V. Larin, I. V. Larina, and M. Motamedi, “Real-time optoacoustic monitoring of temperature in tissues,” in Proc. SPIE, 3601, 268–275 (1999). [122] R. O. Esenaliev, et al., “Laser optoacoustic technique for real-time measurement of thermal damage in tissues,” in Proc. SPIE, 3594, 98–109 (1999). [123] J. Kandulla, H. Elsner, R. Birngruber, and R. Brinkmann, “Noninvasive optoacoustic online retinal temperature determination during continuous-wave laser irradiation,” J. Biomed. Opt., 11(4), 041111 (2006). [124] J. Shah, et al., “Photoacoustic imaging and temperature measurement for photothermal cancer therapy,” J. Biomed. Opt., 13(3), 034024 (2008). [125] S. H. Wang, C.-W. Wei, S.-H. Jee, and P.-C. Li, “Photoacoustic temperature measurements for monitoring of thermal therapy,” in Proc. SPIE, 7177, 71771S (2009). [126] K. Kim, et al., “Tumor-homing multifunctional nanoparticles for cancer theragnosis: Simultaneous diagnosis, drug delivery, and therapeutic monitoring,” J. Control. Release, 146(2), 219–227 (2010). [127] G. M. Lanza, et al., “Theragnostics for tumor and plaque angiogenesis with perfluorocarbon nanoemulsions,” Angiogenesis, 13(2), 189–202 (2010). [128] A. H. Liao and P. C. Li, “The role of high frequency ultrasound in multimodality small animal imaging for cancer research,” J. Med. Ultrasound, 17(2), 86–97 (2009). [129] R. Olafsson, D. R. Bauer, L. G. Montilla, and R. S. Witte, “Real-time, contrast enhanced photoacoustic imaging of cancer in a mouse window chamber,” Opt. Express, 18(18), 18625–18632 (2010). [130] A. Louie, “Multimodality imaging probes: design and challenges,” Chem. Rev., 110(5), 3146–3195 (2010). [131] G. E. R. Weller, F. S. Villanueva, E. M. Tom, and W. R. Wagner, “Targeted ultrasound contrast agents: in vitro assessment of endothelial dysfunction and multi-targeting to ICAM-1 and sialyl Lewisx,” Biotechnol. Bioeng., 92(6), 780–788 (2005) [132] Y. Akiyama, T. Mori, Y. Katayama, and T. Niidome, “The effects of PEG grafting level and injection dose on gold nanorod biodistribution in the tumor-bearing mice,” J. Control. Release, 139(1), 81–84 (2009). [133] A. L. Klibanov, et al., “Targeting and ultrasound imaging of microbubble-based contrast agents,” MAGMA, 8(3), 177–184 (1999). [134] N. Deshpande, M. A. Pysz, and J. K. Willmann, “Molecular ultrasound assessment of tumor angiogenesis,” Angiogenesis, 13(2), 175–188 (2010). [135] J. K. Willmann, et al., “ Dual-targeted contrast agent for US assessment of tumor angiogenesis in vivo.” Radiology, 248(3), 936–944 (2008). [136] Y. Y. Yu, S.-S. Chang, C.-L. Lee, and C. R. C. Wang, “Gold nanorods: electrochemical synthesis and optical properties,” J. Phys. Chem. B, 101(34), 6661–6664 (1997). [137] J. A. Feshitan, C. C. Chen, J. J. Kwan, and M. A. Borden, “Microbubble size isolation by differential centrifugation,” J. Colloid Interface Sci., 329(2), 316–324 (2009). [138] A. F. Prokop, et al., “Polyacrylamide gel as an acoustic coupling medium for focused ultrasound therapy,” Ultrasound Med. Biol., 29(9), 1351–1358 (2003). [139] Y.-H. Chuang, P. W. Cheng, S. C. Chen, J. L. Ruan, and P. C. Li, “Effects of ultrasound-induced inertial cavitation on enzymatic thrombolysis”, Ultrasonic Imaging, 32, 33–47 (2010). [140] K. Kim, et al., “Tumor-homing multifunctional nanoparticles for cancer theragnosis: Simultaneous diagnosis, drug delivery, and therapeutic monitoring,” J. Control. Release, 146(2), 219–227 (2010). [141] M.A Pysz, SS. Gambhir and J. K. Willimann, “Molecular imaging: current status and emerging strategies,” Clin. Radiol, 65(7), 500–516 (2010). [142] M. M. Khalil, J. L. Tremoleda, T. B. Bayomy, and W. Gsell, “Molecular SPECT imaging: an overview,” Int. J. Mol. Imaging, 2011(2011), 796025 (2011). [143] Y.-E. Koo, et al., 'Brain cancer diagnosis and therapy with nanoplatforms,' Adv. Drug. Deliv. Rev., 58(14), 1556–1577, (2006). [144] H. Kobayashi, M.R. Longmire, M. Ogawa, P. L. Choyke, and S. Kawamoto, “Multiplexed imaging in cancer diagnosis: applications and future advances,” Lancet Oncol., 11(6), 589–595 (2010). [145] H.Y. Ko, K. J. Choi, C. H. Lee, S. Kim, “A multimodal nanoparticle-based cancer imaging probe simultaneously targeting nucleolin, integrin αvβ3 and tenascin-C proteins,” Biomaterials, 32(4), 1130–1138(2011). [146] Y. H. Wang, A. H. Liao, J. H. Chen, C.-R. Wang and P. C. Li, “A photoacoustic/ultrasound dual-modality contrast agent and its application to thermotherapy”, J. Biomed. Opt., 17(4), 045001 (2012). [147] X. Huang, P.K. Jain, I.H. El-Sayed, M.A. El-Sayed, 'Gold nanoparticles: interesting optical properties and recent applications in cancer diagnostics and therapy,' Nanomedicine, 2(5), 681–693 (2007). [148] P.-C. Li, et al., “In vivo photoacoustic molecular imaging with simultaneous multiple selective targeting using antibody-conjugated gold nanorods,” Opt. Exp., 16(23), 18605–18615, (2008). [149] T. Niidome, et al., “Poly(ethylene glycol)-modified gold nanorods as a photothermal nanodevice for hyperthermia,” J. Biomater. Sci. Polym. Ed., 20(9), 1203–1215, (2009). [150] W. G. Pitt, G. A. Husseini, and B. J. Staples, “Ultrasonic drug delivery–a general review,” Expert Opin. Drug Deliv., 1(1), 37–56 (2004). [151] C.R. Anderson, et al., “Ultrasound molecular imaging of tumor angiogenesis with an integrin targeted microbubble contrast agent, ” Invest. Radiol., 46(4), 215–24 (2011). [152] A.-H. Liao, S.-Y. Wu, H.-E. Wang, C.-H. Weng, M.-F. Wu and P.-C. Li, “Evaluation of 18F-labeled targeted perfluorocarbon-filled albumin microbubbles as a probe for microUS and microPET in tumor-bearing mice”, Ultrasonics, 53, 320–327 (2012). [153] C. Y. Lai, C. H. Wu, C. C. Chen, and P. C. Li, “Quantitative relations of acoustic inertial cavitation with sonoporation and cell viability,” Ultrasound Med. Biol., 32(12), 1931–1941 (2006). [154] P.A. Dijkmans, et al., “Microbubbles and ultrasound: from diagnosis to therapy,” Eur. J. Echocardiogr., 5(4), 245–246 (2004). [155] J. D. Hutcheson, R. K. Schlicher, H. K. Hicks, and M. R. Prausnitz, “Saving cells from ultrasound-induced apoptosis: quantification of cell death and uptake following sonication and effects of targeted calcium chelation,” Ultrasound Med. Biol., 36(6), 1008–1021 (2010). [156] S.-W. Chu, I-H. Chen, T.-M. Liu, P. C. Cheng, C.-K. Sun, and B.-L. Lin, “Multimodal nonlinear spectral microscopy based on a femtosecond Cr:forsterite laser,” Opt. Lett., 26(23), 1909–1911 (2001). [157] K. W. Hu, et al., “Efficient near-IR hyperthermia and intense nonlinear optical imaging contrast on the gold nanorod-in-shell nanostructures,” J. Am. Chem. Soc., 131(40), 14186–14187 (2009). [158] H. Y. Jun, H. H. Yin, S. H. Kim, S. H. Park, H. S. Kim, and K. H.Yoon, “Visualization of tumor angiogenesis using MR imaging contrast agent Gd-DTPA-anti-VEGF receptor 2 antibody conjugate in a mouse tumor model,” Korean J Radiol., 11(4), 449–456 (2010). [159] International Standard IEC 60825-1:1993+A:1997+A2:2001, “Safety of laser products—part 1: Equipment classification, requirements and user’s guide.,” International Electrotechnical Commission (IEC), Geneva, Switzerland. [160] Weintraub K., “Biomedicine: The new gold standard,” Nature.14:495(7440), S14–6 (2013). [161] J. M. Warram, A. G. Sorace, and K. Hoyt, “A triple-targeted ultrasound contrast agent provides improved localization to tumor vasculature,” J. Ultrasound Med., 30(7), 921–931(2011). [162] O. Couture, S. Bannouf, G. Montaldo, J. F. Aubry, M. Fink, and M. Tanter, “Ultrafast imaging of ultrasound contrast agents,” Ultrasound Med. Biol., 35(11), 1908–1916(2009). | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/60327 | - |
dc.description.abstract | 多模式影像乃結合不同的成像機制,在影像中提供互補性資訊,如解剖結構與分子功能,而可作為病情診斷、治療與監測的依據。為加速擷取動態資訊,本論文選擇以光聲與超音波雙模式影像為研究基礎,並從改善系統規格與影像品質出發,延伸至雙模式分子探針在診療的應用。影像的品質可以由解析度來評斷,它包括對時間、空間和對比的解析能力。現今大部分的光聲影像系統幀率限制於雷射規格,成像只在幾十赫茲;為了提高時間解析度,本論文以高重複率的脈衝雷射和商用超音波陣列系統來實現超快光聲成像,陣列可以做平行信號接收,以波束成型組成二維影像;若搭配發送平面波,則超音波影像亦可同時獲得。高速成像的方法則可應用於三維或四維的光聲影像,並且以合成孔徑聚焦技術來改善陣列的水平向聚焦、提升影像品質。除外,因高速成像下的影像信雜比較差,為改善空間和對比分辨率,論文中提出同調因子為基礎的可適性波束成像方法,加入對通道信雜比的評估,修改同調因子定義,改進傳統同調因子受環境雜訊的影響。以超音波和光聲的快速成像的影像作為測試,結果顯示此方式可改善空間解析度與對比度,且能在嘈雜的環境裡保持影像強度。
論文的第二部分為雙模式分子探針的開發,利用超音波顯影劑(微氣泡)與光聲顯影劑(奈米金桿)的結合,做成帶金微氣泡,能在雙模式中做為對比增強劑;而帶金微氣泡經由表面抗體修飾,能夠識別特定分子,增加在血管新生區域的附著量,累積效果可用超音波影像來觀察。該分子探針也能搭配雷射來進行光熱治療,藉由奈米金桿吸光來提升區域溫度,可同時以光聲方式進行溫度監測。並且利用微氣泡的穴蝕效應,可以促使奈米桿的釋放而增加療效,實驗以光聲、光熱方式做巨觀的觀察,再以非線性光學方式作微觀的確認。故以帶金微氣泡做為雙模式顯影劑,不單能提升在光聲與超音波影像對比,亦具有診療監測等多功用途。總結此光聲與超音波的雙模式研究,從系統改良以提高結構影像品質與動態量測的精準,而雙模式分子探針的引入,則結合了光學與聲學的特性,擴展其於生醫診療之應用與功能。 | zh_TW |
dc.description.abstract | Multi-modality imaging can provide complementary information, such as structure and function. It integrates the advantages from the different modalities and has been a promising approach to improve diagnosis and to monitor therapy. To speed up the acquisition and for accurate measurements, the photoacoustic/ultrasound (PA/US) dual-modality imaging is studied in the research. It starts with system improvement and array processing and explores the potential in theranosis with the PA/US contrast agent. The imaging performance is measured by the resolution, including temporal, spatial and contrast. Ultrafast PA imaging is first implemented with a high pulse-repetition-rate laser and an US array system. With transmitting plane wave, ultrafast US images can be simultaneously obtained. The system is applied to acquire 3D/4D data and its elevational focusing is improved by the synthetic aperture technique. Besides, because high-frame-rate imaging usually suffers from low signal to noise ratio (SNR) and poor spatial and contrast resolution, the coherence based adaptive beamforming is proposed. Specifically, it modifies the definition of coherence factor (CF) according to the aperture SNR. It is tested with US and PA data and found that the spatial resolution and contrast can be improved by the SNR-dependent CF while maintaining the image intensity in the noisy environment.
The other topic is to develop the dual-modality molecular probe. The gold microbubbles (AuMBs), which are composed by microbubbles (MB) and gold nanorods (AuNR), provide PA/US contrast enhancement. With surface modification, it can target to the angiogenesis region and the accumulation is observed by US imaging. Photothermal effect can be induced by the plasmonic heating of AuNRs and the temperature rise can be monitored by PA imaging. Moreover, MB cavitation helps to release AuNRs and the improved effect is proven with PA, photothermal, and nonlinear optical methods. In summary, the dual-modality research improves the structural imaging and dynamic measurements by ameliorating system performance and the introduction of dual-modality molecular probe expands the biomedical applications and functions. | en |
dc.description.provenance | Made available in DSpace on 2021-06-16T10:15:37Z (GMT). No. of bitstreams: 1 ntu-102-F95921046-1.pdf: 3937733 bytes, checksum: 4d71a090fa88f9889bcfdad75c493720 (MD5) Previous issue date: 2013 | en |
dc.description.tableofcontents | ABSTRACT I
中文摘要 III GLOSSARY OF SYMBOLS V TABLE OF CONTESTS VII LIST OF FIGURES X LIST OF TABLES XV Chapter 1 Introduction 1 1.1 Principles of photoacoustic (PA) imaging 1 1.2 Ultrasound (US) imaging system 5 1.3 PA contrast agents 8 1.4 Objectives 9 1.4.1 Ultrafast PA imaging and improved resolution method for US/PA imaging. 10 1.4.2 Dual-modality contrast agent 10 1.5 Dissertation organization 11 Chapter 2 Ultrafast photoacoustic imaging and its application to real-time 3D imaging with improved focusing 13 2.1 Introduction 13 2.2 Materials and methods 15 2.2.1 System setups 15 2.2.2 Image processing 17 2.3 Experiment results 19 2.3.1 Ultrafast PA/US imaging 19 2.3.2 Point spread function (PSF) 19 2.3.3 Phantom experiments 22 2.4 Discussions and conclusions 24 Chapter 3 Adaptive beamforming for US/PA imaging 26 3.1 Introduction 26 3.2 Formulations and methods 30 3.2.1 Formulation of array processing 30 3.2.2 Postfilter and CF 32 3.2.3 Proposed method 35 3.3. Simulations and experiments 38 3.3.1 Simulation of point pair data and US cyst images 38 3.3.2 Acquisition of clinical US images 39 3.3.3 Acquisition of PA images 40 3.4 Results and discussions 40 3.4.1 Simulated STA-US imaging 40 3.4.2 Clinical US imaging using the STA method 45 3.4.3. Ultrafast PA imaging 49 3.5 Conclusions 51 Chapter 4 Dual-Modality contrast agent and its applications 53 4.1 Introduction 53 4.2 Materials and methods 56 4.2.1 Preparing AuMBs and targeted AuMBs for flow cytometry and cell attachment 56 4.2.2 Experimental setup of the imaging system and LIT 58 4.3 Results 59 4.3.1 Particle analysis and TEM 59 4.3.2 PA characteristics 60 4.3.3 Dual-modality imaging 62 4.3.4 Targeted efficacy and LIT 64 4.4 Discussions and conclusions 67 Chapter 5 Demonstration of gold nanorods delivery with acoustic cavitation 69 5.1 Introduction 69 5.2 Materials and methods 72 5.2.1 Preparation of (non-)targeted AuMBs and the molecular ultrasound image 72 5.2.3 In vivo enhanced delivery of gold nanorods with acoustic cavitation 74 5.3 Results 76 5.3.1 In vivo demonstration of US molecular image 76 5.3.2 In vitro examination with acoustic cavitation 78 5.3.3 In vivo examination with acoustic cavitation 81 5.4 Discussion and conclusions 84 Chapter 6 Discussion, conclusion and future works 86 6.1 Discussion 86 6.2 Conclusion 87 6.3 Future works 88 References 89 Publication List 102 | |
dc.language.iso | en | |
dc.title | 光聲與超音波雙模式影像:系統發展與分子探針應用 | zh_TW |
dc.title | Photoacoustic and Ultrasound Dual-Modality Imaging: System Development and the Applications of Molecular Probes | en |
dc.type | Thesis | |
dc.date.schoolyear | 101-2 | |
dc.description.degree | 博士 | |
dc.contributor.oralexamcommittee | 江惠華(Huihua Chiang),廖愛禾(Ai-Ho Liao),宋孔彬(Kung-Bin Sung),劉子銘(Tzu-Ming Liu) | |
dc.subject.keyword | 光聲影像,超音波陣列系統,同調因子,微氣泡,奈米金桿, | zh_TW |
dc.subject.keyword | Photoacoustic,ultrasound array system,coherence factor,microbubbles,gold nanorods, | en |
dc.relation.page | 104 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2013-08-19 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 生醫電子與資訊學研究所 | zh_TW |
顯示於系所單位: | 生醫電子與資訊學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-102-1.pdf 目前未授權公開取用 | 3.85 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。