Please use this identifier to cite or link to this item:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/55907
Full metadata record
???org.dspace.app.webui.jsptag.ItemTag.dcfield??? | Value | Language |
---|---|---|
dc.contributor.advisor | 陳力騏(Richie L. C. Chen) | |
dc.contributor.author | Wei-Cheng Chen | en |
dc.contributor.author | 陳韋成 | zh_TW |
dc.date.accessioned | 2021-06-16T05:10:34Z | - |
dc.date.available | 2014-08-22 | |
dc.date.copyright | 2014-08-22 | |
dc.date.issued | 2014 | |
dc.date.submitted | 2014-08-18 | |
dc.identifier.citation | 1. 三軍總醫院感染管制室。2012。醫院消毒劑的介紹。臺北:三軍總醫院感染管制室。網址:http://wwwu.tsgh.ndmctsgh.edu.tw/inf/。上網日期:2014-06-02。
2. 吳宗桓。2009。應用於生化感測器之可攜帶循環伏安式恆電位儀設計與實現。碩士論文。臺南:國立臺南大學通訊工程研究所。 3. 顏旭亨、陳淑慧、黃美麗、林麗珍。2012。內視鏡高層次消毒液之使用及管理。感染控制雜誌 22(4):163-169。 4. Ahmadi, M.M., G.A. Jullien. 2009. Current-mirror-based potentiostats for three-electrode amperometric electrochemical sensors. Circuits and Systems I: Regular Papers, IEEE Transactions on 56(7): 1339-1348. 5. Alfa, M.J., D.L. Sitter. 1994. In-hospital evaluation of orthophthalaldehyde as a high level disinfectant for flexible endoscopes. J. Hosp. Infect. 26(1): 15-26. 6. Allison, M.C., C.R. Bradley, R. Tighe, A. Fraise, J. Holton, D. Campbell, L. Thomson, R.L. Gray, B.W. Taylor, D.J. Cbe, K.R. Palmer. 2008. Guidelines for decontamination of equipment for gastrointestinal endoscopy. London: British Society of Gastroenterology. Available at: www.bsg.org.uk. Accessed 28 May 2014. 7. Avdikos, E.M., M.I. Prodromidis, C.E. Efstathiou. 2005. Construction and analytical applications of a palm-sized microcontroller-based amperometric analyzer. Sensors Actuators B: Chem. 107(1): 372-378. 8. Ayers, S., K.D. Gillis, M. Lindau, B.A. Minch. 2007. Design of a cmos potentiostat circuit for electrochemical detector arrays. IEEE Transactions on Circuits and Systems I: Regular Papers 54(4): 736-744. 9. Bard, A.J., L.R. Faulkner, 2001. Electrochemical methods: Fundamentals and applications, 632-658. New Jersey: Wiley. 10. Blanco, J.R., F.J. Ferrero, J.C. Campo, J.C. Anton, J.M. Pingarron, A.J. Reviejo, J. Manso. 2006. Design of a low-cost portable potentiostat for amperometric biosensors, Instrumentation and Measurement Technology Conference, 2006. IMTC 2006. Proceedings of the IEEE, pp. 690-694. 11. Brett, C.M.A., A.M.O. Brett, 1993. Electrochemistry: Principles, methods, and applications. New York: Oxford University Press, Incorporated. 12. Busoni, L., M. Carla, L. Lanzi. 2002. A comparison between potentiostatic circuits with grounded work or auxiliary electrode. Rev. Sci. Instrum. 73(4): 1921-1923. 13. Cai, X., K. Kalcher. 1994. Studies on the electrocatalytic reduction of aliphatic aldehydes on palladium-modified carbon paste electrodes. Electroanalysis 6(5-6): 397-404. 14. Chen, R.L.C., 2012. Electrochemistry for biomedical researchers, 29-37. Taipei and Singapore: National Taiwan University Press and World Scientific Publishing Company Incorporated. 15. Chiorcea-Paquim, A.-M., A.M. Oliveira-Brett. 2013. Redox behaviour of g-quadruplexes. 16. Cooke, R.P.D., S.V. Goddard, A. Whymant-Morris, J. Sherwood, R. Chatterly. 2003. An evaluation of cidex opa (0.55% ortho-phthalaldehyde) as an alternative to 2% glutaraldehyde for high-level disinfection of endoscopes. J. Hosp. Infect. 54(3): 226-231. 17. Doelling, R. 2000. Potentiostats—an introduction to the principle of potentiostatic control, including basic potentiostatic circuits, electrochemical applications, and some notes on electrode and cell design. 2nd ed. Germany: Bank Elektronik - Intelligent Controls GmbH. 18. Forsberg, G., J.W. O'laughlin, R.G. Megargle, S.R. Koirtyihann. 1975. Determination of arsenic by anodic stripping voltammetry and differential pulse anodic stripping voltammetry. Analytical Chemistry 47(9): 1586-1592. 19. Genov, R., M. Stanacevic, M. Naware, G. Cauwenberghs, N.V. Thakor. 2006. 16-channel integrated potentiostat for distributed neurochemical sensing. IEEE Transactions on Circuits and Systems I: Regular Papers 53(11): 2371-2376. 20. Ghica, M.E., R. Pauliukaite, N. Marchand, E. Devic, C.M.A. Brett. 2007. An improved biosensor for acetaldehyde determination using a bienzymatic strategy at poly(neutral red) modified carbon film electrodes. Anal. Chim. Acta 591(1): 80-86. 21. Gil, E.S., R.O. Couto. 2013. Flavonoid electrochemistry: A review on the electroanalytical applications. Brazilian Journal of Pharmacognosy 23(3): 542-558. 22. Gopinath, A.V., D. Russell. 2006. An inexpensive field-portable programmable potentiostat. The Chemical Educator 11(1): 23-28. 23. Greef, R. 1978. Instruments for use in electrode process research. Journal of Physics E: Scientific Instruments 11(1): 1. 24. Hamidi-Asl, E., E. Hasheminejad, M. Mascini. 2013. A review on the electrochemical biosensors for determination of micrornas. Talanta 115: 74-83. 25. Harvey, D., 2000. Modern analytical chemistry, 461-542. New York: McGraw-Hill. 26. Harwood, G.W.J., C.W. Pouton. 1996. Amperometric enzyme biosensors for the analysis of drugs and metabolites. Adv. Drug Del. Rev. 18(2): 163-191. 27. Huang, C.-Y., M.-H. Lee, Z.-H. Wu, H.-Y. Tseng, Y.-C. Huang, B.-D. Liu, H.-Y. Lin. 2009. A portable potentiostat with molecularly imprinted polymeric electrode for dopamine sensing, 2009 IEEE Circuits and Systems International Conference on Testing and Diagnosis, ICTD'09, April 28, 2009 - April 29, 2009. IEEE Computer Society, Chengdu, China, pp. Institute of Electrical and Electronics Engineers, IEEE; IEEE Circuits and Systems Society, CASS. 28. Huang, C.Y., M.J. Syu, Y.S. Chang, C.H. Chang, T.C. Chou, B.D. Liu. 2007. A portable potentiostat for the bilirubin-specific sensor prepared from molecular imprinting. Biosensors Bioelectron. 22(8): 1694-1699. 29. Huang, Y., Y. Liu, B.L. Hassler, R.M. Worden, A.J. Mason. 2013. A protein-based electrochemical biosensor array platform for integrated microsystems. IEEE Transactions on Biomedical Circuits and Systems 7(1): 43-51. 30. Iniewski, K., 2008. Vlsi circuits for biomedical applications, 265-286. Boston: Artech House. 31. Jackowska, K., P. Krysinski. 2013. New trends in the electrochemical sensing of dopamine. Anal. Bioanal. Chem. 405(11): 3753-3771. 32. Jane Maxwell, E., A.D. Mazzeo, G.M. Whitesides. 2013. Paper-based electroanalytical devices for accessible diagnostic testing. MRS Bulletin 38(4): 309-314. 33. JHU. 2000. Reliability assured with CIDEXR solution test strips. Baltimore: Johns Hopkins Hospital. Available at: www.hopkinsmedicine.org. Accessed 10 March 2014. 34. JHU. 2004. CidexR opa solution test strips. Baltimore: Johns Hopkins Hospital. Available at: www.hopkinsmedicine.org. Accessed 10 March 2014. 35. King, D., J. Friend, J. Kariuki. 2010. Measuring vitamin c content of commercial orange juice using a pencil lead electrode. Journal of Chemical Education 87(5): 507-509. 36. Kotanen, C.N., F.G. Moussy, S. Carrara, A. Guiseppi-Elie. 2012. Implantable enzyme amperometric biosensors. Biosensors Bioelectron. 35(1): 14-26. 37. Kwakye, S., A. Baeumner. 2007. An embedded system for portable electrochemical detection. Sensors Actuators B: Chem. 123(1): 336-343. 38. Lee, S.W., J.C. Meranger. 1981. Determination of total arsenic species by anodic stripping voltammetry. Analytical Chemistry 53(1): 130-131. 39. Liu, K.E., H.D. Abruna. 1989. Electroanalysis of aromatic aldehydes with modified carbon paste electrodes. Analytical Chemistry 61(23): 2599-2602. 40. Loncaric, C., Y.T. Tang, C. Ho, M.A. Parameswaran, H.Z. Yu. 2012. A USB-based electrochemical biosensor prototype for point-of-care diagnosis. Sens. Actuator B-Chem. 161(1): 908-913. 41. Lorenzo, E., F. Pariente, L. Hernandez, F. Tobalina, M. Darder, Q. Wu, M. Maskus, H.D. Abruna. 1998. Analytical strategies for amperometric biosensors based on chemically modified electrodes. Biosensors Bioelectron. 13(3–4): 319-332. 42. Maloy, J.T. 1983. Factors affecting the shape of current-potential curves. Journal of Chemical Education 60(4): 285. 43. Mascini, M., F. Lucarelli, I. Palchetti, G. Marrazza. 2001. Electrochemical application of DNA biosensors, International Conference on Sensor Technology (ISTC 2001), October 10, 2001 - October 12, 2001. SPIE, Wuhan, China, pp. 8-19. 44. Narula, H.S., J.G. Harris. 2006. A time-based vlsi potentiostat for ion current measurements. Sensors Journal, IEEE 6(2): 239-247. 45. Palecek, E., M. Bartoik. 2012. Electrochemistry of nucleic acids. Chemical Reviews 112(6): 3427-3481. 46. Petersen, B.T.M.D.F., J.M.D. Chennat, J.M.D.F. Cohen, P.B.M.D.F. Cotton, D.a.M.D.F. Greenwald, T.E.M.D. Kowalski, M.L.D.O. Krinsky, W.G.M.D. Park, I.M.M.D.F. Pike, J.M.D.F. Romagnuolo, A.Q.a.I.E.C. For The, W.a.P.M.P.H. Rutala, A. For the Society for Healthcare Epidemiology Of. 2011. Multisociety guideline on reprocessing flexible gi endoscopes: 2011. Infect. Control Hosp. Epidemiol. 32(6): 527-537. 47. Ramfos, I., N. Vassiliadis, S. Blionas, K. Efstathiou, A. Fragoso, C.K. O'sullivan, A. Birbas. 2013. A compact hybrid-multiplexed potentiostat for real-time electrochemical biosensing applications. Biosensors Bioelectron. 47: 482-489. 48. Rezaul Hasan, S.M. 2007. Stability analysis and novel compensation of a cmos current-feedback potentiostat circuit for electrochemical sensors. Sensors Journal, IEEE 7(5): 814-824. 49. Rodriguez-Mozaz, S., M.-P. Marco, M.J. Lopez De Alda, D. Barcelo. 2004. Biosensors for environmental monitoring of endocrine disruptors: A review article. Anal. Bioanal. Chem. 378(3): 588-598. 50. Rowe, A.A., A.J. Bonham, R.J. White, M.P. Zimmer, R.J. Yadgar, T.M. Hobza, J.W. Honea, I. Ben-Yaacov, K.W. Plaxco. 2011. Cheapstat: An open-source, 'do-it-yourself' potentiostat for analytical and educational applications. PLoS One 6(9): 1-7. 51. Rutala, W.A., D.J. Weber, HICPAC. 2008. Guideline for disinfection and sterilization in healthcare facilities, 2008. Atlanta: Centers for Disease Control and Prevention. Available at: www.cdc.gov. Accessed 29 May 2014. 52. Rutala, W.a.P.M.P.H., D.J.M.D.M.P.H. Weber. 1999. Disinfection of endoscopes: Review of new chemical sterilants used for high‐level disinfection •. Infect. Control Hosp. Epidemiol. 20(1): 69-76. 53. Scozzari, A. 2008.Electrochemical sensing methods: A brief review. In: Evangelista, V., Barsanti, L., Frassanito, A., Passarelli, V., Gualtieri, P. (Eds.), Algal toxins: Nature, occurrence, effect and detection, 335-351. Netherlands: Springer. 54. SGNA. 2012. Standards of infection control in reprocessing of flexible gastrointestinal endoscopes. Chicago: Society of Gastroenterology Nurses and Associates. Available at: www.sgna.org. Accessed 29 May 2014. 55. Shen, L., Z. Chen, Y. Li, S. He, S. Xie, X. Xu, Z. Liang, X. Meng, Q. Li, Z. Zhu, M. Li, X.C. Le, Y. Shao. 2008. Electrochemical dnazyme sensor for lead based on amplification of DNA−au bio-bar codes. Analytical Chemistry 80(16): 6323-6328. 56. Shiddiky, M.J.A., A.a.J. Torriero. 2011. Application of ionic liquids in electrochemical sensing systems. Biosensors Bioelectron. 26(5): 1775-1787. 57. Spaulding, E.H. 1968.Chemical disinfection of medical and surgical materials. In: Lawrence, C.A., Block, S.S., Reddish, G.F. (Eds.), Disinfection, sterilization, and preservation, 517-531. Philadelphia: Lea & Febiger. 58. Suginta, W., P. Khunkaewla, A. Schulte. 2013. Electrochemical biosensor applications of polysaccharides chitin and chitosan. Chemical Reviews 113(7): 5458-5479. 59. Vashook, V., J. Zosel, U. Guth. 2012. Oxygen solid electrolyte coulometry (OSEC). J. Solid State Electrochem. 16(11): 3401-3421. 60. Vergani, M., M. Carminati, G. Ferrari, E. Landini, C. Caviglia, A. Heiskanen, C. Comminges, K. Zor, D. Sabourin, M. Dufva, M. Dimaki, R. Raiteri, U. Wollenberger, J. Emneus, M. Sampietro. 2012. Multichannel bipotentiostat integrated with a microfluidic platform for electrochemical real-time monitoring of cell cultures. Biomedical Circuits and Systems, IEEE Transactions on 6(5): 498-507. 61. Vergnes, J.S., B. Ballantyne. 2002. Genetic toxicology studies with glutaraldehyde. J. Appl. Toxicol. 22(1): 45-60. 62. Walsh, S.E., J.Y. Maillard, A.D. Russell, A.C. Hann. 2001. Possible mechanisms for the relative efficacies of ortho-phthalaldehyde and glutaraldehyde against glutaraldehyde-resistant mycobacterium chelonae. J. Appl. Microbiol. 91(1): 80-92. 63. Wang, J., 2006. Analytical electrochemistry, 29-42. New Jersey: Wiley. 64. Wang, W.S., H.Y. Huang, S.C. Chen, K.C. Ho, C.Y. Lin, T.C. Chou, C.H. Hu, W.F. Wang, C.F. Wu, C.H. Luo. 2011. Real-time telemetry system for amperometric and potentiometric electrochemical sensors. Sensors 11(9): 8593-8610. 65. Weng, J.-L., M.H. Ho, W.K. Nonidez. 1990. Amperometric determination of formaldehyde via the hexacyanoferrate(iii) -coupled dehydrogenase reaction. Anal. Chim. Acta 233(0): 59-63. 66. Xu, Y., E. Wang. 2012. Electrochemical biosensors based on magnetic micro/nano particles. Electrochimica Acta 84: 62-73. 67. Zhang, X.-B., R.-M. Kong, Y. Lu. 2011. Metal ion sensors based on dnazymes and related DNA molecules. Annual Review of Analytical Chemistry 4: 105-128. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/55907 | - |
dc.description.abstract | 本研究採用具有高輸入阻抗、低輸入偏壓電流與低輸入補償電壓等特性之運算放法器(OPA2336P,Texas Instruments),搭配USB供電的DAQ(NI 6008/6009,National Instruments)與LabVIEWTM撰寫的圖形化使用者介面,組裝一台平行輸入自動換檔並且便於攜帶之小型恆電位儀,可應用於實驗室外的現場檢測並且與商用實驗室泛用型儀器(AutolabTM,Eco Chemie)相比所得到之檢測結果幾乎相同。本研究所提出之恆電位儀操作電位的範圍約從-1.3 V到1.1 V,最佳量測的解析度可到100 pA。以本研究所提出之恆電位儀搭配流動式注射系統,對鄰苯二甲醛濃度做初步的的濃度檢測,所量測到的氧化電流大小在0.2%-0.65%(w/v)範圍內呈線性相關(R2 = 0.9911),且變異係數小於5%,靈敏度為0.18 μA/cm2 mM,可應用於評估消毒內視鏡常用之鄰苯二甲醛最低有效濃度(Minimum effective concentration, MEC)。 | zh_TW |
dc.description.abstract | An auto ranging mini-potentiostat was constructed by parallel reading architecture and using operational amplifiers (OPA2336P, Texas Instruments) with high input impedance, low input bias current and low input offset voltage. After implementing with a USB-powered DAQ (NI 6008/6009, National Instruments) and LabVIEWTM based graphical user interface, the portable electrochemical device can be used for on-site analysis with a performance comparable to a commercialized laboratory machine (AutolabTM, Eco Chemie). The operating voltage ranges from -1.3 V to 1.1 V and the resolution can reach 100 pA level. The mini-potentiostat was served as the amperometric detector of a conventional flow injection analysis system for measuring o-phthalaldehyde concentration. The current outputs (the peak heights of FIAgram) are reproducible (CV < 5%) and showed good linearity (R2 = 0.9911) in the range of 0.2%-0.5% (w/v), which can be used to evaluate the antiseptic efficiency (minimum effective concentration of o-phthalaldehyde) of the disinfectant used for cleaning endoscope. The sensitivity is 0.18 μA/cm2 mM. | en |
dc.description.provenance | Made available in DSpace on 2021-06-16T05:10:34Z (GMT). No. of bitstreams: 1 ntu-103-R01631016-1.pdf: 4825191 bytes, checksum: 10835953c3455b7dc37812b2035fee34 (MD5) Previous issue date: 2014 | en |
dc.description.tableofcontents | 摘要 i
目錄 iii 圖目錄 vi 表目錄 viii 第一章 研究目的 1 第二章 文獻探討 2 2.1 電化學分析 2 2.1.1 二極與三極式電極架構 2 2.1.2 電位測定法(Potentiometry) 4 2.1.3 庫倫量測法(Coulometry) 5 2.1.4 伏安法(Voltammetry) 6 2.1.5 電流測定法(Amperometry) 9 2.2 恆電位儀(Potentiostat) 11 2.2.1 電位控制組態 13 2.2.1.1 工作電極接地 13 2.2.1.2 輔助電極接地 14 2.2.2 電流量測組態 15 2.3.2.1 轉阻放大器量測 (Transimpedance amplifier measurement) 15 2.2.2.2 電流經純電阻跨壓差動量測 17 2.2.2.3 電流傳輸器量測 (Current conveyor measurement) 19 2.3 內視鏡消毒劑 20 2.3.1 鄰苯二甲醛 (o-phthalaldehyde, OPA) 20 2.3.2 鄰苯二甲醛現行檢測方法與棄置 23 第三章 研究方法 23 3.1 實驗藥品與製備 25 3.2 實驗儀器與器材 26 3.3 恆電位儀電路元件建置與選擇 27 3.3.1 分段電阻檔位 27 3.3.2 檔位合併無段量測 29 3.3.3 元件選擇 33 3.4 恆電位儀基本性能校正與測試 34 3.4.1 Dummy cell 測試 34 3.4.2 Electrochemical cell測試 35 3.4.3 樣品循環伏安法測試 36 3.4.4 定電位電流測定法(Amperometry) 37 3.5 以電化學法檢測消毒劑鄰苯二甲醛(o-phthalaldehyde, OPA) 38 3.5.1 鄰苯二甲醛與甘胺酸反應後之氧化電位檢測 38 3.5.2 流動注射式系統架設 39 3.5.3 鄰苯二甲醛定電位電流測定 41 第四章 結果與討論 42 4.1 恆電位儀基本性能分析 42 4.1.1 Dummy cell 測試結果與限制 42 4.1.2 Electrochemical cell測試結果與限制 44 4.1.3 樣品循環伏安圖之比較與分析 46 4.1.4 定電位電流測定圖之比較與分析 48 4.2 OPA濃度檢測分析) 51 第五章 結論 54 第六章 參考文獻 55 第七章 附錄 63 | |
dc.language.iso | zh-TW | |
dc.title | USB驅動型迷你恆電位儀之開發與鄰苯二甲醛消毒劑之檢測 | zh_TW |
dc.title | Development of a USB-powered Mini-potentiostat and the Detection of o-phthalaldehyde Disinfectant | en |
dc.type | Thesis | |
dc.date.schoolyear | 102-2 | |
dc.description.degree | 碩士 | |
dc.contributor.coadvisor | 陳仲瑄(Chung-Hsuan Chen) | |
dc.contributor.oralexamcommittee | 鄭宗記(Tzong-Jih Cheng),陳林祈(Lin-Chi Chen) | |
dc.subject.keyword | 恆電位儀,鄰苯二甲醛,消毒劑, | zh_TW |
dc.subject.keyword | potentiostat,o-phthalaldehyde,disinfectant, | en |
dc.relation.page | 67 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2014-08-19 | |
dc.contributor.author-college | 生物資源暨農學院 | zh_TW |
dc.contributor.author-dept | 生物產業機電工程學研究所 | zh_TW |
Appears in Collections: | 生物機電工程學系 |
Files in This Item:
File | Size | Format | |
---|---|---|---|
ntu-103-1.pdf Restricted Access | 4.71 MB | Adobe PDF |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.