請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/46559完整後設資料紀錄
| DC 欄位 | 值 | 語言 |
|---|---|---|
| dc.contributor.advisor | 林正芳 | |
| dc.contributor.author | Cheng-Yu Huang | en |
| dc.contributor.author | 黃晟祐 | zh_TW |
| dc.date.accessioned | 2021-06-15T05:15:35Z | - |
| dc.date.available | 2012-07-29 | |
| dc.date.copyright | 2010-07-29 | |
| dc.date.issued | 2010 | |
| dc.date.submitted | 2010-07-21 | |
| dc.identifier.citation | Abdel-Jawad, M., Ebrahim, S., Al-Atram, F. and Al-Shammari, S. (1997) Pretreatment of the municipal wastewater feed for reverse osmosis plants. Desalination 109(2), 211-223.
Adham, S.S., Snoeyink, V.L., Clark, M.M. and Anselme, C. (1993) Predicting and verifying TOC removal by PAC in pilot-scale UF system. J. Am. Water Works Ass. 85(12), 58-68. Allison, R.P. (1995) Electrodialysis reversal in water reuse applications. Desalination 103(1-2), 11-18. Ang, W.S., Lee, S. and Elimelech, M. (2006) Chemical and physical aspects of cleaning of organic-fouled reverse osmosis membranes. Journal of Membrane Science 272(1-2), 198-210. Bartels, C., Hirose, M. and Fujioka, H. (2008) Performance advancement in the spiral wound RO/NF element design. Desalination 221(1-3), 207-214. Bourgeous, K.N., Darby, J.L. and Tchobanoglous, G. (2001) Ultrafiltration of wastewater: effects of particles, mode of operation, and backwash effectiveness. Water Research 35(1), 77-90. Bowen, W.R., Calvo, J.I. and Hernandez, A. (1995) Steps of membrane blocking in flux decline during protein microfiltration. Journal of Membrane Science 101(1-2), 153-165. Buer, T. and Cumin, J. (2010) MBR module design and operation. Desalination 250(3), 1073-1077. Mulder, M. (1996) Basic principles of membrane technology. Kluwer Academic Publishers. Pearce, G.K. (2008) UF/MF pre-treatment to RO in seawater and wastewater reuse applications: a comparison of energy costs. Desalination 222(1-3), 66-73. Qin, J.-J., Htun Oo, M., Nyunt Wai, M., Lee, H., Hong, S.P., Kim, J.E., Xing, Y. and Zhanga, M. (2005) Pilot study for reclamation of secondary treated sewage effluent. Desalination 171(3), 299-305. Qin, J.-J., Kekre, K.A., Tao, G., Oo, M.H., Wai, M.N., Lee, T.C., Viswanath, B. and Seah, H. (2006) New option of MBR-RO process for production of NEWater from domestic sewage. Journal of Membrane Science 272(1-2), 70-77. Qin, J.-J., Oo, M.H., Kekre, K.A. and Liberman, B. (2009) Development of novel backwash cleaning technique for reverse osmosis in reclamation of secondary effluent. Journal of Membrane Science 346(1), 8-14. Raval, H.D., Trivedi, J.J., Joshi, S.V. and Devmurari, C.V. (2010) Flux enhancement of thin film composite RO membrane by controlled chlorine treatment. Desalination 250(3), 945-949. Sagiv, A. and Semiat, R. (2005) Backwash of RO spiral wound membranes. Desalination 179(1-3), 1-9. Suzuki, Y., Ogoshi, M., Yamagata, H., Ozaki, M. and Asano, T. (2002) Large-Area and On-site Water Reuse in Japan. World Day for Water International Seminar, March. Vrouwenvelder, J.S., Graf von der Schulenburg, D.A., Kruithof, J.C., Johns, M.L. and van Loosdrecht, M.C.M. (2009) Biofouling of spiral-wound nanofiltration and reverse osmosis membranes: A feed spacer problem. Water Research 43(3), 583-594. Zhao, Y., Song, L. and Ong, S.L. (2010) Fouling behavior and foulant characteristics of reverse osmosis membranes for treated secondary effluent reclamation. Journal of Membrane Science 349(1-2), 65-74. FILMTECTM,逆滲透和奈濾膜元件-產品與技術手冊,2008版 經濟部水利署水利規劃試驗所,廢污水再生利用技術研究台中市福田水資源回收中心再生水試用計畫(1/2),民國96年12月 FILMTECTM,逆滲透和奈濾膜元件-產品與技術手冊,2008版 經濟部水利署水利規劃試驗所,污水再生利用技術研究-環境新興污染物流佈調查及評估,民國97年 | |
| dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/46559 | - |
| dc.description.abstract | 本研究以迪化污水廠二沉池出流水為對象,利用逆滲透(reverse osmosis, RO)薄膜系統進行污水回收再利用,以達新加坡NEWater再生水水質標準,增加回收水的可利用性,並探討不同前處理設備、操作通量及CIP(clean in place)清洗薄膜時間對薄膜積垢行為的影響,進而以經濟效益分析找出最佳操作條件。
原水經RO系統處理後,其pH值為4.82-7.41,低於水質標準7-8.5,故需加藥調整,其他項目如氨氮、硝酸鹽氮、電導度、總溶解固體及總有機碳皆符合NEWater水質標準。 在無前處理的情況下,薄膜積垢速率為微濾(microfiltration, MF)及超濾(ultrafiltration, UF)膜作為前處理時的10-16倍,故前處理設備能大幅降低薄膜積垢速率。 以MF為前處理時,RO膜最佳操作條件為CIP清洗時間6小時,標準化通量回復率清洗後達96 %,操作通量為10 LMH,單位產水耗電量為15 及20 LMH的73 %及55 %。 以UF為前處理時,RO膜最佳操作條件為CIP清洗時間12小時,標準化通量回復率清洗後達96-100 %,操作通量為10 LMH,單位產水耗電量為20 LMH的63 %。 比較前處理MF及UF在最佳操作條件時之經濟效益,以UF作為前處理時,其最佳操作條件時的單位產水耗電量為MF的69 %。故在利用RO膜回收迪化污水廠二沉池出流水時,其最佳條件為UF作為前處理、CIP時間為12小時及操作通量為10 LMH。 | zh_TW |
| dc.description.abstract | The objective of the present study is to monitor the fouling of reverse osmosis (RO) membrane system in terms of economic analysis by optimization of pretreatment, operation flux rate and frequency of membrane cleaning, and also to achieve the RO permeate water quality to match the Singapore NEWater quality standards.
Two types of membranes processes microfiltration (MF) and ultrafiltration (UF) were used for pretreatment before RO filtration at various operating fluxes. The performances of MF and UF processes were monitored in terms of flux recovery and the over all process pretreatment including RO filtration performance was monitored with energy consumption. The RO treatment with MF was carried out at initial operating fluxes of 10, 15 and 20 LMH with an intermittent chemical cleaning for every 6 hr. Results show that a good recovery of about 96 % normalized flux after chemical cleaning was achieved. The energy consumption calculations for only RO membrane filtration after the MF pretreatment at an initial flux of 10 LMH is 68.5 kWh/m3. In comparison the energy consumption for RO filtration after MF pretreatment at low operating flux (10 LMH) is 1.38 and 1.81 times lower than the energy consumptions at operating fluxes of 15 and 20 LMH respectively. In the case of RO system with UF, the pretreatment was carried out with initial operating fluxes of 10 and 20 LMH followed with an intermittent chemical cleaning for every 12 hr. Excellent recovery of 96-100 % was achieved. The energy consumption for only RO membrane filtration after the MF pretreatment at an initial flux of 10 LMH is calculated as 80.5 kWh/m3 and is 1.58 times lower than 20 LMH flux. The energy consumption comparison of whole process of RO filtration including MF and UF pretreatments by taking in to consideration of frequency of chemical cleaning shows that the process involving UF pretreatment results an energy consumption of 69 % with that of MF process. Further the RO permeate quality in terms of turbidity, NO3--N, NH4+-N, conductivity, total dissolved solids (TDS) and total organic carbon (TOC) matches with the Singapore NEWater quality standards, but the pH values of RO permeate was 4.82-7.41 that is lower than the standard values 7.0-8.5. In conclusion, from the energy consumption in achieving high quality standards of permeate, the RO system with a pretreatment of UF membrane is suggestible in the reclamation of water. | en |
| dc.description.provenance | Made available in DSpace on 2021-06-15T05:15:35Z (GMT). No. of bitstreams: 1 ntu-99-R97541103-1.pdf: 1235667 bytes, checksum: 4e7ea32ca9f2c1c3f92156da8b888ff0 (MD5) Previous issue date: 2010 | en |
| dc.description.tableofcontents | 致謝 I
中文摘要 II Abstract III 目錄 IV 圖目錄 VI 表目錄 VII 第一章 緒論 1 1-1 研究緣起 1 1-2 研究目的與內容 1 第二章 文獻回顧 3 2-1 水回收再利用 3 2-1-1 國外水回收再利用技術發展 3 2-1-2 國內水回收再利用技術發展 5 2-2 薄膜 7 2-2-1 薄膜種類與型式 7 2-2-2 薄膜積垢 9 2-3 逆滲透膜系統於水回收再利用 11 2-3-1 前處理設備 12 2-3-2 膜通量影響 13 2-3-3 薄膜清洗 14 第三章 實驗材料與方法 16 3-1 實驗內容 16 3-2 實驗設備 18 3-2-1 前處理設備 18 3-2-2 RO實驗室模型廠 19 3-3 實驗步驟與方法 21 3-3-1 RO膜調理 21 3-3-2 前處理與操作通量試驗 22 3-3-3 CIP清洗頻率試驗 22 3-4 分析儀器設備與方法 23 第四章 結果與討論 24 4-1 回收水處理程序 24 4-2 前處理與操作通量試驗 25 4-2-1 前處理之產水水質 25 4-2-2 薄膜積垢情形 25 4-3 CIP清洗時間之試驗 30 4-4 RO膜系統之最佳化 35 4-4-1 各操作條件下之單位產水耗電量 35 4-4-2 各操作條件下之平均標準化通量下降速率 41 4-5 最佳化流程 43 第五章 結論與建議 45 5-1 結論 45 5-2 建議 46 參考文獻 47 附錄 50 | |
| dc.language.iso | zh-TW | |
| dc.subject | 水回收 | zh_TW |
| dc.subject | RO膜 | zh_TW |
| dc.subject | 膜積垢 | zh_TW |
| dc.subject | 前處理 | zh_TW |
| dc.subject | 操作通量 | zh_TW |
| dc.subject | CIP清洗 | zh_TW |
| dc.subject | fouling | en |
| dc.subject | water reuse | en |
| dc.subject | CIP | en |
| dc.subject | operation flux | en |
| dc.subject | pretreatment | en |
| dc.subject | RO membrane | en |
| dc.title | 逆滲透系統於水回收之最佳操作與維護 | zh_TW |
| dc.title | The Optimal Operation and Maintenance Process in Reverse Osmosis System for Water Reclamation | en |
| dc.type | Thesis | |
| dc.date.schoolyear | 98-2 | |
| dc.description.degree | 碩士 | |
| dc.contributor.oralexamcommittee | 林郁真,康佩群 | |
| dc.subject.keyword | RO膜,膜積垢,前處理,操作通量,CIP清洗,水回收, | zh_TW |
| dc.subject.keyword | RO membrane,fouling,pretreatment,operation flux,CIP,water reuse, | en |
| dc.relation.page | 65 | |
| dc.rights.note | 有償授權 | |
| dc.date.accepted | 2010-07-22 | |
| dc.contributor.author-college | 工學院 | zh_TW |
| dc.contributor.author-dept | 環境工程學研究所 | zh_TW |
| 顯示於系所單位: | 環境工程學研究所 | |
文件中的檔案:
| 檔案 | 大小 | 格式 | |
|---|---|---|---|
| ntu-99-1.pdf 未授權公開取用 | 1.21 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。
