dc.identifier.citation | 1. 彭柏硯. 使用減白血品之效益評估. 2007; Available from: http://www.blood.org.tw.
2. Foundation, T.B.S., Leukocyte-Reduced Blood Components Supplied ,2007. 2008. 3. Foundation, T.B.S., Leukocyte-Reduced Blood Components Supplied,2008. 2009. 4. 洪正昇. 減除白血球血品的好處. 2007; Available from: http://www.blood.org.tw. 5. 羅仕錡, ed. 臨床輸血醫學. 2002, 合記圖書出版社: 台北. 41. 6. 張進祿. 如何提供安全的醫療用血. 2004; Available from: http://www.blood.org.tw. 7. 陳雯. 淺談輸血與輸血反應. 2006; Available from: http://www.blood.org.tw. 8. Perkins HA, P.R., Fergusson J, Wood M. , Non Haemolytic transfusion reactions. Quantitative effects of blood components with emphasis on isoantigenic incompatibility of leucocytes. Vox Sang, 1966. 11: p. 578-600. 9. Eisenfield L, S.H., McLaughlin J, et al Prevention of transfusion-associated cytomegalovirus infection in neonatal patients by the removal of white cells from blood Transfusion, 1992. 32: p. 205-209. 10. Vakkila J, M.i.G., Amount and type of leukocytes in 'leukocyte-free' red cell and platelet concentrates. Vox Sang, 1987. 53: p. 76-82. 11. S, S., ed. Platelet alloimmunization, in Anderson KC, Ness PM (eds):Scientific Basis of Transfusion Medicine. ed. P. Philadelphia, Saunders. 1994. p.527-543. 12. Saarinnen UM, K.R., Slimes MA, et al, Effective prophylaxis against platelet refractoriness in multitransfused patients by use of leukocyte-free blood components. Blood, 1990. 75: p. 512-517. 13. HA, P., Is white cell reduction cost-effective. Transfusion, 1993. 33: p. 626-628. 14. Friedman LI, S.R., Wagner S J, ed. Reducing the ineffectivity of blood components: what we have learned, in Nance ST (ed): Blood Supply: Perceptions and Prospects for the Future. ed. V. Arlington, American Association of Blood Banks. 1994. p. 139-167. 15. HA, P., Transfusion-induced immunologic unresponsiveness. Transfus Med Rev, 1988. 2: p. 196-203. 16. Gulter K, L.N., ed. Transfusion-transmitted cytomegalovirus and EBV disease. Principles of Transfusion Medicine, 2nd ed, ed. S.T. Rossi EC, Moss G, Gould S. 1996, Williams and Wilkins: Baltimore. p. 717–732. 17. Sazama K, H.P., ed. Transfusion-induced graft-versus-host disease. Immunobiology of Transfusion Medicine, ed. G. G. 1994, Marcel Dekker: New York. p. 631–656. 18. Ward, H.N., Pulmonary Infiltrates Associated with Leukoagglutinin Transfusion Reactions. Annals of Internal Medicine, 1970. 73: p. 689-694. 19. Heddle NM, K.L., Griffith L, et al, A prospective study to identify the risk factors associated with acute reactions to platelet and red cell transfusions. Transfusion, 1993. 33: p. 794-797. 20. Klein M, F.R., Flechsig E, Raeber AJ, Kalinke U, Bluethmann H, Bootz F, Suter M, Zinkernagel RM, Aguzzi A, A crucial role for B cells in neuroinvasive scrapie. Nature, 1997. 390: p. 687– 690. 21. B, W., ed. Leukocyte-free red cells:The evolution of a safer blood product. Controversies of Leukocyte-Poor Blood and Components, ed. B.M.e. McCarty LJ. 1989, American Association of Blood Banks: Arlington, VA. p. 27-48 22. James J, M.R., Holdsworth RF, et al, The role of filtration in the provision of leukocyte-poor red cells to multitransfnsed patients. Pathology, 1986. 18: p. 127-130. 23. Bruil, A., et al., The mechanisms of leukocyte removal by filtration. Transfus Med Rev, 1995. 9(2): p. 145-66. 24. B, W., Leukocyte-poor blood. CRC Crit Rev ClinLab Sci, 1986. 24: p. 1-20. 25. Meryman HT, B.J., Lebovitz R, The preparation of leukocyte-poor red cells: A comparative study. Transfusion, 1980. 20: p. 285-292. 26. Chaplin H, B.T., Cassell M, Methods for preparation of suspensions of buffy-coat-poor red blood cells for transfusion. Am J Clin Pathol, 1959. 31: p. 373-383. 27. Sirchia G, P.A., Rebulla P, et ah, Evaluation of three procedures for the preparation of leukocyte-poor and leukocyte-free red blood cells for transfusion. Vox Sang, 1980. 38: p. 197-204. 28. AU, S., Prevention of hemolysis during freezing and thawing of red cells. Lancet, 1950. 2: p. 901-903. 29. Crowley JP, W.P., Wish C, The purification of red ceils for transfusion by freeze-preservation and washing. V. Red cell recovery and residual leukocytes after freezepreservations with high concentrations of glycerol and washing in various systems. Transfusion, 1977. 17: p. 1-7. 30. Amer KA, P.D., Urbaniak SJ, Lymphocyte, granulocyte and platelet contamination of blood frozen by the low glycerol liquid nitrogen technique. Br J Haematol, 1980. 44: p. 253-261. 31. Reverberi R, M.C., Clinical efficacy of five filters specific for leukocyte removal. Vox Sang, 1990. 58: p. 188-191. 32. A, F., A simple method of removing leucocytes from blood. Br J Exp Pathol, 1926. 7: p. 281-286. 33. Diepenhorst P, E.C., Removal of leucotyes from whole blood and erythrocyte suspensions by filtrations through cotton wool. V, Results after transfusion of 1,820 units of filtered erythrocytes. Vox Sang, 1975. 29: p. 15-8. 34. Heertjes PM, Z.P., Clarification of liquids using filter aids--Part II--Depth filtration. Powder Technol, 1978. 19: p. 31-43. 35. DB, P., Device and method for depletion of the leukocyte content of blood and blood components. EP Patent, 1987. Appl 0.313.348. 36. Nishimura T, K.T., Umegae M, et al, ed. A trial of leukocyte removal without platelet loss. Transactions of the Third World Biomaterials Congress. 1988, Kyoto: Japan. p. 481. 37. Bock M, W.M., Knuppel W, et al, Preparation of white cell-depleted blood---Comparison of two bedside filter systems. Transfusion, 1990. 30: p. 26-29. 38. Pietersz, R.N., et al., Comparison of five different filters for the removal of leukocytes from red cell concentrates. Vox Sang, 1992. 62(2): p. 76-81. 39. AuBuchon, J.P., et al., Evaluation of a new prestorage leukoreduction filter for red blood cell units. Vox Sang, 1997. 72(2): p. 101-6. 40. Yoshihiro Endo, T.T., Tohru Yokota, et al, 106 Depletion of WBC With CF-2, a New Leukocyte Removal Filter. American Journal of Hematology, 1993. 44: p. 38-41. 41. Sadoff BJ, S.R., Friedman LI, ed. Six logl0 leuko-depletion red cell filters, in Abstracts of Papers to be Presented at the International Society of Blood Transfusion/American Association of Blood Banks Joint Congress. ed. V. Arlington, American Association of Blood Banks. 9. 42. Kao, W.J., et al., Complement-mediated leukocyte adhesion on poly(etherurethane ureas) under shear stress in vitro. J Biomed Mater Res, 1996. 32(1): p. 99-109. 43. Lin-Yue L. Yung, R.W.C.b., Stuart L. Cooper, The effect of high molecular weight kininogen on neutrophil adhesion to polymer surfaces. Immunopharmacology, 1999. 43: p. 281-286. 44. Kao, W.J., Evaluation of leukocyte adhesion on polyurethanes: the effects of shear stress and blood proteins. Biomaterials, 2000. 21(22): p. 2295-303. 45. Kim, E.J., et al., Preparation of surface-modified poly(butylene terephthalate) nonwovens and their application as leukocyte removal filters. J Biomed Mater Res B Appl Biomater, 2009. 90(2): p. 849-56. 46. Lewis, A.L., et al., Wettable phosphorylcholine-containing polymers useful in blood filtration. J Mater Sci Mater Med, 2003. 14(1): p. 39-45. 47. Natori, S.H., Y. Gomei, and A. Higuchi, Synthesis and performance of amphiphilic copolymers for blood cell separation. J Biomed Mater Res B Appl Biomater, 2006. 78(2): p. 318-26. 48. Higuchi A, S.Y., Gomei Y, Mori T, Uyama T, Umezawa A, Fleming, Cell separation between mesenchymal progenitor cells through porous polymeric membranes. J Biomed Mater Res: p. in press. 49. Higuchi A, Y.S., Yoon BO, Sakurai N, Hara M, Peripheral blood cell separation through surface-modified polyurethane membranes. J Biomed Mater Res, 2004. 68: p. 34-42. 50. Blackshear PL, A.R., Hemolysis thresholds in microporous structures. Blood Cells, 1977. 3: p. 377-395. 51. Blackshear PL, C.T., Majerle ILl, et al, Resistance of erythrocyte flow into pores. J Rheol, 1979. 23: p. 681-702. 52. Bruil, A., et al., Asymmetric membrane filters for the removal of leukocytes from blood. J Biomed Mater Res, 1991. 25(12): p. 1459-80. 53. Guidoin R, T.K., Bain WH, Blood filter evaluation. Biomat Med Dev Art Org, 1977. 5: p. 317-336. 54. Bruil A, B.L., Terlingen JGA, et al, ed. In vitro leukocyte adhesion on modified polyurethane surfaces. Transactions of the Fourth World Biomaterials Congress. 1992, Berlin: Germany.p. 282. 55. Bruil A, T.J., Beugeling T, et al, In vitro leukocyte adhesion to modified polyurethane surfaces--I--Effect of ionizable functional groups. Biomaterials, 1992. 13: p. 915-923. 56. Lee JH, P.J., Lee liB, Cell adhesion and growth on polymer surfaces with hydroxyl groups prepared by water vapour plasma treatment. Biomaterials, 1991. 12: p. 443-448. 57. Ertel SI, C.A., Horbett TA, et al, Endothelial cell growth on oxygen-containing films deposited by radiofrequency plasmas:The role of surface carbonyl groups. J Biomater Sci Polymer Ed, 1991. 3: p. 163-183. 58. Kataoka K, S.Y., Maruyama A, et al, Controlled adsorption of cells on microdomain structured polymer surfaces. Polymer Mater Sci Eng, 1985. 53: p. 37-41. 59. Grasel TG, C.S., Properties and biological interactions of polyurethane anionomers: Effect of sulphonate incorporation. J Biomed Mater Res, 1989. 23: p. 311-338. 60. ASG, C., Cell adhesion. Progr Biophys Mol Biol, 1973. 27: p. 317-375. 61. Vassar PS, H.J., Seaman GVF, Surface properties of human lymphocytes. Biochim Biophys Acta, 1973. 291: p. 107-115. 62. Harkes G, F.J., Dankert J, Adhesion of Escherichin coil on to a series of poly(methacrylates) differing in charge and hydrophobicity. Biomaterials, 1991. 12: p. 853-860. 63. Hypotension and Bedside Leukocyte Reduction Filters. 1999; Available from: http://www.fda.gov/cdrh/safety/hypoblrf.html. 64. Bruil A, B.L., Terlingen JGA, et al, In vitro leukocyte adhesion to modified polyurethane surfaces--II--Effect of wettability. J Colloid Interface Sci, 1994. 165: p. 72-81. 65. Kottke-Marchant K, A.J., Miller KM, et al, Vascular graft-associated complement activation and leukocyte adhesion in an artificial circulation. J Biomed Mater Res, 1987. 21: p. 379-397. 66. Geiger, T.L., et al., Removal of anaphylatoxins C3a and C5a and chemokines interleukin 8 and RANTES by polyester white cell-reduction and plasma filters. Transfusion, 1997. 37(11-12): p. 1156-62. 67. Kazatchkine MD, C.M., Activation of the complement system at the interface between blood artificial surfaces. Biomaterials, 1988. 9: p. 30-35. 68. Morley DJ, F.I., Adhesion of polymorphonuclear leukocytes to protein-coated and platelet adherent surfaces. Thromb Haemost, 1989. 62: p. 1023-1028. 69. Hamburger SA, M.R., GMP-140 mediates adhesion of stimulated platelets to neutrophils. Blood, 1990. 75: p. 550-554. 70. Yeo EL, K.J., Feuerstein IA, Role of PADGEM/GMP-140 in leukocyte-adherent platelet interaction under flow conditions. Blood, 1991. 78: p. 278. 71. Barber TA, L.L., Mosber DL, et alBarber TA, Influence of serum proteins on thrombosis and leukocyte adherence on polymer surfaces. Scan Electron Microsc, 1979. 3: p. 881-890. 72. Forrester JV, L.J., Adhesion of neutrophil leukocytes under conditions of flow. J Cell Sci, 1984. 87: p. 93-110. 73. Garcia-Pardo A, F.O., Adhesion of human T-lymphoid cells to fibronectin is mediated by two different fibronectin domains. Immunology, 1990. 69: p. 121-126. 74. Steneker, I., et al., Electronmicroscopic examination of white cell reduction by four white cell-reduction filters. Transfusion, 1992. 32(5): p. 450-7. 75. Col Harsh Kumar, L.C.P.G., Lt Col DK Mishra, Lt Col RS Sarkar, Brig M Jaiprakash, 2006. MJAFI, Leucodepletion and Blood Products. 62: p. 174-177. 76. EL, S., Clinical use of white-cell poor blood components. Transfusion, 1989. 29: p. 568-571. 77. Bowden RA, S.S., Sayers MH, Use of leukocyte-depleted platelets and cytomegalovirus seronegative red blood cells for prevention of primary cytomegalovirus infection after marrow transplant. Blood, 1991. 78: p. 246-250. 78. AI EJM, V.S., Broersen SM, et al, Reduction of HTLVl-infected cells in blood by leukocyte filtration. Ann Hematol, 1993. 67: p. 295-300. 79. VV., T., ed. Technical Manual. 13th edition, ed. AABB. 1999, Mayland: USA. 80. 羅仕錡, I 血小板,血小板微小顆粒與白血球之交互作用 II 輸血病人血小板抗體之研究, in 醫學院藥理學研究所. 2006, 國立台灣大學: 台北. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/46052 | - |
dc.description.abstract | 許多相關的輸血反應及輸血後的感染疾病已被研究顯示由血液及血品中的白血球所引起。為了降低輸血治療造成的不良反應及疾病感染,去除治療血品中白血球含量是主要的目標;故本研究的目的在於應用與市售商品不同的材料,來開發出可達高效能的紅血球專用之減除白血球過濾器。首先,主要用聚酯纖維(Polyester fiber,PET)搭配不同基重的聚丙烯熔噴不織布(melt-blown nonwoven Polypropylene,PP-NW),利用物理結構性質孔洞大小的不同,來進行血液過濾的實驗;並且再利用高分子乙烯乙烯醇(Poly ethylene-vinyl alcohol,EVAL)聚合物塗佈(coated)於聚酯纖維(Polyester fiber,PET)上,利用化學性質的吸附特性,以增加白血球的去除率。此外,更對市售的紅血球專用之白血球過濾器也同樣做功能性的測試;而在血液方面,將過濾後的血液以自動血球計數分析儀(Automated haematology cell counting device)進行血球的計數,並以 Nageotte血球計數器(Nageotte counting chamber)來做計數的校正,換算出本研究材料及市售商品過濾的效能(Efficiency)以進行比較;在材料方面將以掃描式電子顯微鏡(Scanning Electron Microscope,SEM)來觀察過濾前後不同基重的聚丙烯熔噴不織布,及用高分子乙烯乙烯醇聚合物塗佈的聚酯纖維,共四種材料的微細構造,以及材料上血球的形態學變化。目前研究結果發現,市售過濾器經測試的效能並沒有如標榜的好,推測原因為血液較為黏稠而導致;而本研究所使用的材料其白血球去除率已可達到98.94%,紅血球回收率可達到94.87%以上;幾乎可與市售之商品的效能相提並論,甚至更勝一籌。 | zh_TW |
dc.description.abstract | Many papers have proven that transfusion reactions and infections after transfusions are caused by leukocytes in blood and blood components. In order to decrease above side effects , leucoreduction of blood products is the most important aspect. In this study, the researcher used different materials from commercial filters to develop a new, highly efficient leukocyte removal filter for red blood cell concentrates. Firstly, the principal used melt-blown nonwoven Polypropylene (PP-NW) and was coated with poly(ethylene-co-vinyl alcohol)(EVAL) on a Polyester fiber (PET) to take advantage of chemical adhesion properties and the physical porosity structure for studying the blood filtration research. Secondly, the functions of commercial filters were tested, then post-filtration blood counted by Automated haematology cell counting device and Nageotte counting chamber, to compare the efficiency with the study filter. Finally, the surface structure and blood cell morphology on the materials of PP-NW and PET coated EVAL were observed under Scanning Electron Microscope (SEM). At present, the results have shown that three kinds of commercial filters were not good enough, due to the blood samples having higher viscosity. The study filter could remove 98.94% of the leukocytes and recover over 94.87% of the erythrocytes, thus the efficiency was greater than that of current commercial filters, and had potential for such. | en |
dc.description.provenance | Made available in DSpace on 2021-06-15T04:52:27Z (GMT). No. of bitstreams: 1 ntu-99-R97548001-1.pdf: 7024561 bytes, checksum: 6c41edb9e8432ee3b46ef5906679259d (MD5) Previous issue date: 2010 | en |
dc.description.tableofcontents | 中文摘要……………………………………………………I
英文摘要……………………………………………………II 目錄…………………………………………………………III 圖目錄………………………………………………………V 表目錄………………………………………………………VIII 第一章 緒論 ………………………………………………1 第一節 全球現況…………………………………………1 第二節 台灣現況……………………………………1 第三節 未來趨勢……………………………………………………………2 第四節 研究動機………………………………………………………………3 第二章 文獻回顧 ………………………………………………………4 第一節 輸血安全………………………………………………………………4 第二節 減除白血球的好處……………………………………………………4 第三節 去除白血球的方法……………………………………………………5 第四節 白血球過濾的發展與材料應用………………………………………7 第五節 血液過濾的原理………………………………………………………8 第六節 白血球過濾器標準效能規範 ………………………………………10 第三章 實驗材料與方法………………………………………………12 第一節 實驗藥品 ……………………………………………………………12 第二節 實驗儀器 ……………………………………………………………13 第三節 藥品配置 ……………………………………………………………17 第四節 實驗材料與器材 ……………………………………………………19 第五節 實驗商品 ……………………………………………………………20 第六節 實驗方法 ……………………………………………………………21 第四章 結果與討論……………………………………………………28 第一節 過濾基材選用 ………………………………………………………28 第二節 不同基重PP-NW過濾效能比較……………………………………29 第三節 不對稱排列PP-NW過濾效能比較…………………………………30 第四節 白血球貼附測試比較 ………………………………………………31 第五節 高分子材料分析與選用 ……………………………………………31 第六節 市售商品效能測試比較 ……………………………………………33 第七節 市售商品材料測試比較 ……………………………………………35 第八節 過濾容器改造後測試比較 …………………………………………35 第九節 過濾前後材料微觀與血球型態 ……………………………………37 第五章 結論……………………………………………………………39 參考文獻 ………………………………………………………………40 附錄 ……………………………………………………………………46 | |
dc.language.iso | zh-TW | |
dc.title | 研發聚丙烯熔噴不織布/乙烯乙烯醇聚合物塗佈聚酯纖維之白血球過濾器 | zh_TW |
dc.title | The development of leukocyte removal filter by using PP-nonwoven and EVAL-coated Polyester fibers | en |
dc.type | Thesis | |
dc.date.schoolyear | 98-2 | |
dc.description.degree | 碩士 | |
dc.contributor.coadvisor | 林東燦(Dong-Tsamn Lin) | |
dc.contributor.oralexamcommittee | 黃鯤雄,胡衍榮,洪智煌(Chih-Huang Hung) | |
dc.subject.keyword | 白血球過濾器,乙烯乙烯醇,聚丙烯熔噴不織布,聚酯纖維,過濾,效能,塗佈, | zh_TW |
dc.subject.keyword | leukocyte removal filter,EVAL,PP-NW,PET,filtration,efficiency,coated, | en |
dc.relation.page | 76 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2010-08-02 | |
dc.contributor.author-college | 工學院 | zh_TW |
dc.contributor.author-dept | 醫學工程學研究所 | zh_TW |
顯示於系所單位: | 醫學工程學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-99-1.pdf 目前未授權公開取用 | 6.86 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。