1. 韓選棠,2002/10,綠房子宣言-具體而微的綠建築實例,豐年社,P33。 2. 建築学大系編集委員會,1969,新訂建学學大系,株式会社彰國社,P374。 3. 周伯丞,2000/06,建築軀殼開口部自然通風效果之研究,博士論文,P26。 4. 石宏杰,1998,直射光環境下水平與格柵遮陽板之採光效能評估,碩士論文。 5. 黃俊程,1997,居室空間格柵遮陽板暨導光板在直射光環境下之採光效能評估,碩士論文。 6. 劉澄泰,1996,建築物垂直遮陽板之採光與遮蔽效能綜合研究,碩士論文。 7. 李義鴻,1996,建築物開口部外部遮陽系統電腦模擬探討,碩士論文。 8. 賴光邦,1990/07,台灣地區建築物開口部遮陽裝置之電腦模擬,P47-50。 9. 韓選棠及侯文祥,2003/12,兩棟為幕牆辦公大樓節約能源比較暨塑鋼框與鋁框門窗格熱係數計測,南亞塑膠工業股份有限公司,P71-81。 10. 李靖男,2002,建築節約能源設計分析與全尺度實驗印證,碩士論文。 11. 陳逸倫,2001/06,電腦模擬建築物自然採光與外部遮陽節約能源綜合評估之研究,碩士論文。 12. 徐瑞鐘及李浩銓,1999/06,住宅與商業建築耗能總量調查研究,工業技術研究院能源與資源研究所,P4及P30。 13. 游義琦,1990/06,遮陽、晝光利用與空調的綜合省能效果評估,碩士論文,P39-40。 14. 楊冠雄等,1988/07,外氣冷房與省能建築外殼設計節能效果之實驗印證與分析(二),經濟部能源委員會,P32-33。 15. 田中俊六等,簡裕榮等譯,2004/06,最新建築環境工學,六合出版社,P62。 16. 同文15,P16。 17. 陳啟中,1998/08,建築物理概論,詹氏書局,P100。 18. 同文15,P209。 19. 同文15,P206。 20. 吳讓治等,建築技術規則節約能源篇規範,內政部營建署專題研究。 21. 同文15,P197。 22. 同文17,P80。 23. 同文15,P46。 24. 同文17,P81。 25. 日本建築學會編,崔征國譯,1997/08,建築設計資料集成,詹氏書局,P58。 26. 林啟瑞及劉垂芳,1886/09,機械工程實驗(三)-熱工實驗,全華科技圖書股份有限公司,P52。 27. 同文15,P7。 28. 同文15,P15。 29. 谷家恆及楊冠雄,2000/09,建築外殼耗能管制實施現況檢討研究,內政部建築研究所研究,P38。 30. 林憲德等,1996/07,建築節約能源基本教材,內政部建築研究所, P58-59。 31. 吳協勳,2002/06,由建築節能觀點探討外牆構法上隔熱功能改善之研究,碩士論文,P33。 32. 陳錦賜及張世典,1999/06,建築節約能源綜合指標研究,內政部建築研究所,P59-66。 33. 楊冠雄及王士紘,2001/12,建築技術規則建築外殼節約能源設計部份條文及其技術規範之修訂研究,內政部建築研究所研究,P17-P19。 34. 賴榮平等,1991/08,建築物理環境,六合出版社,P3-11及P61-78。 35. 顏貽乙及簡國祥,2001/12,建築外殼性能檢測分析研究(二) -玻璃日光輻射熱取得率量測實驗室建置與建築外殼建材隔熱性能資料庫建立,內政部建築研究所研究,P78。 36. 蕭江碧等,2002/12,建材性能檢測分析實驗研究-子計畫1.建築外殼構材隔熱性能實驗,內政部建築研究所,P8-9。 | |
| dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/39249 | - |
| dc.description.abstract | 「能源」相關議題自石油危機以來受到普遍的重視與發展,國內在建築節能思潮衝擊下,窗戶部位的隔熱及耗能問題也就廣受重視。鋁捲窗是歐洲常用於窗戶部位做為保溫的手法之ㄧ,但由於氣候的差異,鋁捲窗實際應用在台灣的隔熱功效為何卻是不得而知?
本研究希冀藉由窗戶部位隔熱及耗能問題的探討與鋁捲窗應用時的實際測試,能瞭解鋁捲窗是否合適做為台灣窗戶部位隔熱問題之改善良策,期此學術研究之成果未來能落實至實際的運用上,作為設計者與業界之參酌,並期未來能提供予政府機關,作為推廣節約能源時,窗戶部位的設計手法之ㄧ。 研究結論歸納如下: 1.鋁捲窗關閉,不論是單獨使用鋁捲窗或是鋁捲窗與玻璃窗均關閉,其造成的內外溫差與熱阻隔比率均是較高的。 2.冷氣使用後,約可保有5.48℃/h的保溫時間。 3.本研究雖僅針對鋁捲窗隔熱進行探討,但實際上鋁捲窗若全部關閉,裡面窗戶多數也是密閉狀態。當玻璃厚度為3mm,鋁捲窗加玻璃的平均熱傳透率為2.7 W/m2K,而15cmR.C.牆平均熱傳透率為3.5 W/m2K,可知鋁捲窗加玻璃的隔熱效果可達外牆平均熱傳透率標準。在此情況下,外殼等價開窗率及其折減因子規定是否應檢討,才不會使得出於良好立意的綠建築法規,造成建築立面設計時的不合理限制。 | zh_TW |
| dc.description.abstract | Since the petroleum crisis, the subjects in energy shortage became a popular value and development well. Heat insulation and energy consume of windows are valued ethos under energy-saving of architecture in Taiwan. In Europe, rolling shutters with window to be used in heat insulate, but the effects and application in Taiwan are unknown as result in different kinds of climate.
The research hope to discuss heat insulation and energy consume about rolling Shutters, and test the actual application timing to find out appropriately heat insulation questions and improvements for local window spots. This research will be able to contribute the actual apply technique to all designers when the governmental agency promote the save-energy policy in the future. The research method as follows: 1. Realize the analytic conditions of Taiwan heat environment from the climatic data, and use the simple 3D simulation and computer data to discus the heat insulation and heat detrition of rolling Shutters window with improvements and influence. 2. Using thermocouple wire , data-logger and electronic hygrometer account the material superficial temperature diff and humidity diff inside and outside when the rolling shutters off. Research conclusion induction as follows: 1. When rolling Shutters off , using rolling Shutters alone or window with rolling Shutters closure off both make temperature range and surface resistance to become higher. 2. After the air conditioner uses, approximately may hold 5.48 ℃/H. 3. This research only discuss in heat insulation of the rolling Shutters. When the rolling shutters closed completely, glass window was almost in closed state. When glass thickness is 3mm, mean heat transmission coefficient of rolling shutters adds the glass t is 2.7 W/M²K. And mean heat transmission coefficient of 15cm R.C wall is 3.5 W/ M²K, we prove out the heat insulation efficiencies of rolling shutters with glass window can accord mean heat transmission coefficient of outside wall. In this situation, the equal value window-opening rate of outer wall ( Req) and reduction factor should be examined ,or frontispiece design will be bounded unreasonably from the Green Building Laws which have good decides. | en |
| dc.description.provenance | Made available in DSpace on 2021-06-13T17:24:50Z (GMT). No. of bitstreams: 1 ntu-94-R90622039-1.pdf: 8574594 bytes, checksum: 3dc02792fbea4a9450a7613060ec7d6b (MD5) Previous issue date: 2005 | en |
| dc.description.tableofcontents | 目 錄
誌謝 i 中英文摘要 ii 圖表目錄 V 第一章 緒論 第一節 研究緣起與目的 1-1 第二節 研究內容與範圍 1-3 第三節 研究方法與流程 1-4 第四節 鋁捲窗簡介 1-6 第二章 窗戶部位造成隔熱及耗能問題分析 第一節 台灣熱環境 2-1 第二節 窗戶部位日射熱及外氣溫度隔熱缺失 2-4 第三節 窗戶部位耗能缺失 2-6 第三章 文獻回顧 第一節 隔熱及節能效益相關文獻 3-1 第二節 建築熱傳相關理論 3-3 第三節 室內熱環境評估指標 3-10 第四節 温溼度量測方法 3-15 第四章 鋁捲窗與傳統遮陽設備比較 第一節 鋁捲窗與傳統遮陽設備對日射遮蔽效果比較 4-1 第二節 鋁捲窗與傳統遮陽設備節能差異 4-5 第五章 鋁捲窗隔熱實驗量測方法 第一節 實驗目的及地點 5-1 第二節 構造裝置及儀器 5-3 第三節 測點配置及過程 5-8 第六章 隔熱與節能效益量測評估 第一節 隔熱效果量測評估 6-1 第二節 空調電力節能推算 6-8 第七章 結論與建議 第一節 結論 7-1 第二節 建議 7-2 附錄 附錄-1 參考文獻 文-1 | |
| dc.language.iso | zh-TW | |
| dc.subject | 平均熱傳透率 | zh_TW |
| dc.subject | 鋁捲窗 | zh_TW |
| dc.subject | 隔熱 | zh_TW |
| dc.subject | 能源 | zh_TW |
| dc.subject | 熱阻隔比率 | zh_TW |
| dc.subject | surface resistance | en |
| dc.subject | mean heat transmission coefficient | en |
| dc.subject | Heat Insulation Efficiencies | en |
| dc.subject | Rolling Shutters | en |
| dc.subject | energy | en |
| dc.title | 鋁捲窗應用在窗戶部位隔熱及節能效益實測研究
-以台大綠房子為例- | zh_TW |
| dc.title | The Research on Heat Insulation Efficiencies and Energy-saving of the Application in Window with Rolling Shutters —Example for N.T.U.「SMART HOME」 | en |
| dc.type | Thesis | |
| dc.date.schoolyear | 93-1 | |
| dc.description.degree | 碩士 | |
| dc.contributor.oralexamcommittee | 陳宗鵠,侯文祥 | |
| dc.subject.keyword | 鋁捲窗,隔熱,能源,熱阻隔比率,平均熱傳透率, | zh_TW |
| dc.subject.keyword | energy,surface resistance,Rolling Shutters,Heat Insulation Efficiencies,mean heat transmission coefficient, | en |
| dc.relation.page | 75 | |
| dc.rights.note | 有償授權 | |
| dc.date.accepted | 2005-01-26 | |
| dc.contributor.author-college | 生物資源暨農學院 | zh_TW |
| dc.contributor.author-dept | 生物環境系統工程學研究所 | zh_TW |
| 顯示於系所單位: | 生物環境系統工程學系 | |
文件中的檔案:
| 檔案 | 大小 | 格式 | |
|---|---|---|---|
| ntu-94-1.pdf 未授權公開取用 | 8.37 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。