完整後設資料紀錄
DC 欄位值語言
dc.contributor.advisor蘇侃
dc.contributor.authorYuan-Chang Kuanen
dc.contributor.author管原璋zh_TW
dc.date.accessioned2021-06-13T07:50:18Z-
dc.date.available2005-07-30
dc.date.copyright2005-07-30
dc.date.issued2005
dc.date.submitted2005-07-25
dc.identifier.citation1. 蘇建融‚ “人工椎間盤之設計與力學分析‚”碩士論文‚ 國立台灣大學‚ 2004.
2. A. DiMeglio, F. Bonnel, “Chapter 3 Growth of the spine,” Springer-Verlag New York Inc., 1989.
3. M. Sharma, N. A.Langrana, J. Rodriguez, “Role of ligaments and facets in lumbar spinal stability,” Spine, Vol. 20, No. 8, 1995, pp. 887-900.
4. I. A. F. Stokes, “Mechanical function of facet joints in the lumbar spine,” Clin Biomech. Vol.3, No.2, 1988, pp. 101-105.
5. D. J. Botsford, S. I. Esses, and D. J. Ogilivie-Harris, “In-vivo diurnal variation in intervertebral disc volume and morphology,” Spine, Vol.l9, No.8, 1994, pp. 935-940.
6. 參考資料網址 http://www.spineuniverse.com/
7. 參考資料網址http://taiwanspinecenter.com.tw/tsc_c/index.htm
8. H. Nadim, D. L. Helmut, and C. M. Paul, “Biomaterial optimization in total disc arthroplasty,” Spine, Vol.28, No.20s, 2003, pp. s139-s152.
9. J. Goffin, A. Casey, P. Kehr, K. Liebig, B. Lind, C. Logroscino, V. Pointillart, F. Van Calenbergh, J. van Loon , “Preliminary clinical experience with the Bryan Cervical Disc Prosthesis,” Neurosurgery, 51(3), 840-5; discussion 845-7, 2002 Sep.
10. W. C. Bryan, D. G. Jeffrey, E. D. Anton, H. M. Nianbin,and C. M. Paul, “Biomechanical evaluation of total disc replacement arthroplasty:an in vitro human cadaveric model,” Spine, Vol. 28, No. 20S, 2003, pp. S110-S117.
11. A. A. Paul, P. R. Jeffrey, E. B. Vincent, and S. C. Cathy, “Wear Analysis of the Bryan cervical disc prosthesis,” Spine,
Vol. 28, No. 20S, 2003, pp. S186-S194.
12. H. D. Link, “History, design and biomechanics of the Link SB Charité artificial disc,” Eur Spine J, (2002) 11 (Suppl. 2), :S98– S105
13. Andre´ van Ooij, F. Cumhur Oner, Ab J. Verbout, “Complications of Artificial Disc Replacement:A Report of 27 Patients with the SB Charité artificial disc,” Journal of Spinal Disorders & Techniques, 2003, Vol. 16, No. 4, pp. 369–383
14. P. Tropiano, R. C. Huang, F. P. Girardi, T. Ma rnay, “Lumbar Disc Replacement: Preliminary Results with ProDisc Ⅱ After a Minimum Follow-up Period of 1 Year,” Journal of Spinal Disorders & Techniques, 2003, Vol. 16, No. 4, pp. 362-368.
15. E. Z. Jack, A. B. Timothy, N. V. Emiliano, L. S. Barton, F. R. Rashbaum, “Clinical results with ProDisc:European experience and U.S. investigation device exemption study,” Spine, Vol. 28, No. 20S, 2003, pp. S163-S166.
16. Charles D. Ray, “The PDN prosthetic disc-nucleus device,”
Eur Spine J, (2002) 11 (Suppl. 2), S137–S142
17. A. Shirazi-Adl, “Biomechanics of the lumbar spine in sagittal/lateral moments,” Spine, Vol. 19, No. 21, 1994, pp. 2407-2414.
18. J. L. Berry, J. M. Moran, W. S. Berg, and A. D. Steffee, “A morphometric study of human lumbar and selected thoracic vertebrae,” Spine, Vol. 12, No. 4, 1987, pp. 362-367.
19. M. Choux, C. D. Rocco, “The Pediatric Spine Ι,” Spron-Verlag New York Inc., 1989.
20. D. B. Chaffin, M. S. Redfern, M. Erig, S. A. Goldstein, “Lumbar muscle size and location from CT scans of 96 women of age 40 to 60 years,” Clin. Biomech., 5, 1990, pp. 9-16
21. S. H. Teoh, W. H. Chan, R. Thampuran, “An elacto-plastic finite element model for polyethylene wear in total hip arthroplasty,” Journal of Biomechanics, 35, 2002, pp. 323-330.
22. I. Yamamoto, M. M. Panjabi, J. Crisco, S. Bonar, “Three-
dimensional movements of the whole lumbar spine and lumbosacral joint,” Spine, Vol.14, No.11, 1989, pp. 1256-1260.
23. V. K. Goel, Y. Kim, T. Lim, J. Weinstein, “An analytical investigation of the mechanics of spinal instrumentation”, Spine, Vol. 13, No. 9, 1988, pp. 1003-1011.
24. V. K. Goel, W. Kong , JS. Han, JN.Weinstein, LG. Gilbertson, “A combined finite element and optimization investigation of lumbar spine mechanics with and without muscles,” Spine, 18, 1993, pp. 1591-1541.
25. T. D. Brown, K. J. Stewart, J. C. Nieman, D. R. Pedersen, J. J. Callaghan, “Local head roughening as a factor contributing to variability element analysis,” Journal of biomechanical engineering, Vol .124, December, 2002, pp. 691-698.
26. Young Kim, “Prediction of mechanical behaviors at interfaces between bone and two interbody cages of lumbar spine segmemts,” Spine, Vol. 26, No. 13, 2001, pp. 1437-1442.
27. S. K. Field, K. Cooke, A. H. S. Jones, D. G. Teer, “Sputtered coatings for medical applications” Teer Coatings LTD.
28. 范昌源,“椎籠對於腰椎機械性質之參數分析,”碩士論文,國立台灣科技大學,2003.
29. 李勇達,“人工膝關節脛股骨接觸面的最佳化研究及其磨耗行為探討,”博士論文,國立台灣大學,2003.
30. 傅彬豪,“人工腰椎之設計與力學分析,”碩士論文,國立台灣大學, 2004.
31. 林鼎勝, “脊椎基本生物力學之有限元素分析,” 碩士論文,國立成功大學, 1998.
dc.identifier.urihttp://tdr.lib.ntu.edu.tw/jspui/handle/123456789/36046-
dc.description.abstract本研究主要在探討人工椎間盤之接觸面的最佳化設計,人工椎間盤可分為上盤、核心與下盤三個元件,本文即以上盤與核心之接觸面的最佳化設計為主軸。
現今人工椎間盤的研究,以設計出一個可以前彎、後彎與側彎的機構,但對於扭轉的動作並不能有效的提供其活動度。故本研究在人工椎間盤上盤與核心的接觸面改良成橢圓形的機構,以提供人體在扭轉時所需的活動度。
本研究以有限元素法來分析人工椎間盤的接觸面,以應力、應變、變形量與磨耗量為考量,在施以正向壓力與扭轉、前彎等負載,以三個階段來做分析,(1)上盤與核心之接觸面檔板之設計,(2)上盤與核心之接觸面曲率半徑最佳化,(3)在前彎、扭轉時之受力情形下,上盤與核心之接觸面曲率半徑最佳化。
經過分析之後,本研究提供了上盤與核心接觸面的最佳化設計,並且研究其在人體的安全性,並希望未來能夠作植入人體測試,以期達到最適合人體使用之人工椎間盤。
zh_TW
dc.description.abstractThe optimum shape of artificial disc were studied is this research. The artificial disc constructed of superior and inferior cobalt-chromium-molybdenum endplates with a polyethylene articulating bearing. The analysis of the contact face between the upper endplate and the central core was derived in this research.
According the former research, the artificial disc was similar to the activities of the real vertebral disc but the angle of rotation was restrained completely. So in this research, we design an ellipse contact face between the upper endplate and the central core for the activities of rotation.
Using the finite element analysis for the contact stress, wear and displacement of the contact face between the upper endplate and the central core, we derive an optimum shape for the contact face in three stages. The first stage is the design of the blocking plate of the contact face. The second stage is comparing four kinds of radius of curvature of the contact face. The third stage is comparing two kinds of radius of curvature of the contact face under flexion and rotation.
After analysis, we obtain the optimum shape of the artificial disc and prove the safety of the artificial disc is well for human using. However, only after long-term follow-up of clinical experience with the artificial disc is this research could prove the optimum shape of the artificial disc.
en
dc.description.provenanceMade available in DSpace on 2021-06-13T07:50:18Z (GMT). No. of bitstreams: 1
ntu-94-R92522520-1.pdf: 1430928 bytes, checksum: 3a3848708aedd902944865044bc3d709 (MD5)
Previous issue date: 2005
en
dc.description.tableofcontents目錄
Abstract……………………………………………………………Ι
摘要…………………………………………………………………Ⅲ
目錄…………………………………………………………………Ⅳ
表目錄………………………………………………………………Ⅶ
圖目錄………………………………………………………………Ⅷ
第一章 緒論
1-1 簡介…………………………………………………………… 1
1-2 人體椎間盤與小面關節的簡介……………………………… 2
1-2-1 椎間盤之簡介…………………………………………… 2
1-2-2 小面關節之簡介………………………………………… 3
1-3 人工椎間盤之簡介…………………………………………… 4
1-3-1 Bryan Cervical Disc Prosthesis……………………4
1-3-2 SB Charitè…………………………………………………………………………………5
1-3-3 Prodisc………………………………………………… 6
1-3-4 Prestige…………………………………………………6
1-3-5 Prosthetic Disc Nucleus…………………………… 7
1-4 文獻回顧……………………………………………………… 8
1-4-1 椎間盤與小面關節之相關文獻回顧………………… 8
1-4-2 人工椎間盤之相關文獻回顧………………………… 8
1-4-3 腰椎之相關文獻回顧…………………………………10
1-4-4 有限元素法分析之相關文獻回顧……………………11
第二章 人工椎間盤接觸面的最佳化
2-1 人工椎間盤接觸面的設計……………………………………13
2-1-1 人工椎間盤模型簡介…………………………………13
2-1-2 人工替代物的使用材質………………………………14
2-1-3 人工椎間盤接觸面最佳化設計………………………18
2-2 有限元素法……………………………………………………19
2-3 人工椎間盤接觸面的分析……………………………………20
2-3-1 分析方法………………………………………………21
2-4 有限元素運算參數的設定……………………………………22
2-4-1 材料性質………………………………………………22
2-4-2 負載與邊界條件……………………………………………23
2-4-3 接觸問題………………………………………………24
2-4-4 網格設定………………………………………………25
2-4-5 分析參數與破壞準則………………………………………27
第三章 有限元素法分析結果
3-1 簡介……………………………………………………………29
3-2 上盤與核心之接觸面檔板之設計的結果比較………………30
3-3 上盤與核心之接觸面曲率半徑的結果比較…………………31
3-4 在前彎、扭轉之受力情形下,上盤與核心之接觸面曲率半
徑的結果比較…………………………………………………32
第四章 討論
4-1 上盤與核心之接觸面檔板之設計討論………………………35
4-2 上盤與核心之接觸面曲率半徑的討論………………………37
4-3 在前彎、扭轉之受力情形下,上盤與核心之接觸面曲率半
徑的討論………………………………………………………40
4-4 人工椎間盤活動度的探討……………………………………43
第五章 結論與未來研究方向
5-1 結論……………………………………………………………44
5-2 未來研究方向…………………………………………………45
參考文獻………………………………………………………………47
表目錄
表一 腰椎之前彎、後彎與伸展平均活動範圍…………………53
表二 腰椎之軸向扭轉平均活動範圍……………………………53
表三 腰椎之側彎平均活動範圍…………………………………54
表四 前彎與伸展之平均活動範圍標準差………………………54
表五 Mechanical properties of dominant orthopedic biomaterials…
…………………………………………………………… 55
表六 本研究所使用之材料性質…………………………………56
表七 各設計方案之節點數與總元素數…………………………56
表八 第一階段有限元素法分析後各元件之平均與最大應力結
果……………………………………………………………57
表九 第二階段有限元素法分析後各元件之平均與最大應力結
果……………………………………………………………57
表十 第三階段有限元素法分析後各元件之平均與最大應力結
果……………………………………………………………58
表十一 各階段之核心變化比例…………………………………59
表十二 人工椎間盤和Prodisc、SB charite與真實腰椎的活動度
……………………………………………………………60
圖目錄
圖一 脊椎側視圖…………………………………………………61
圖二 脊椎構造圖…………………………………………………61
圖三 椎間盤構造圖………………………………………………62
圖四 椎間盤構造圖………………………………………………62
圖五 椎間盤病變圖………………………………………………63
圖六 小面關節構造圖……………………………………………63
圖七 Bryan Cervical Disc Prosthesis構造圖…………………64
圖八 SB Charitè構造圖…………………………………………64
圖九 Prodisc構造圖…………………………………………… 65
圖十 Prestige Disc構造圖………………………………………65
圖十一 Prosthetic Disc Nucleus構造圖………………………66
圖十二 蘇建融設計之人工椎間盤………………………………66
圖十三 蘇建融設計之人工椎間盤模型之二等角視圖…………67
圗十四 COSMOSWorks之接觸組定義…………………………68
圖十五 網格品質定義……………………………………………69
圗十六 人工椎間盤模型網格化…………………………………69
圖十七 第一階段各元件之平均von Mises應力結果………… 70
圖十八 第一階段各元件之最大von Mises應力結果………… 70
圖十九 上盤12mm/核心11mm有檔板之最大von Mises應
力與降服強度之比………………………………… 71
圖二十 上盤12mm/核心11mm無檔板之最大von Mises應
力與降服強度之比………………………………… 71
圖二十一 第一階段核心之變形比例………………………… 72
圖二十二 第二階段各元件之平均von Mises應力結果………72
圖二十三 第二階段各元件之最大von Mises應力結果………73
圖二十四 12/11.5之最大von Mises應力與降服強度之比……73
圖二十五 13/12之最大von Mises應力與降服強度之比…… 74
圖二十六 13/12.5之最大von Mises應力與降服強度之比……74
圖二十七 第二階段核心之變形比例……………………………75
圖二十八 第三階段12/11各元件之平均von Mises應力結果…75
圖二十九 第三階段12/11各元件之最大von Mises應力結果…76
圖三十 第三階段13/12各元件之平均von Mises應力結果…76
圖三十一 第三階段13/12各元件之最大von Mises應力結果…77
圖三十二 12/ 11前彎之最大von Mises應力與降服強度之比較…77
圖三十三 12/ 11扭轉之最大von Mises應力與降服強度之比較…78
圖三十四 13/ 12前彎之最大von Mises應力與降服強度之比較…78
圖三十五 13/ 12扭轉之最大von Mises應力與降服強度之比較…79
圖三十六 第三階段之變形比例……………………………………79
dc.language.isozh-TW
dc.subject替代物zh_TW
dc.subject人工椎間盤zh_TW
dc.subject有限元素法zh_TW
dc.subject腰椎zh_TW
dc.subjectlumbaren
dc.subjectfinite elementen
dc.subjectartificial discen
dc.title人工椎間盤接觸面之設計與分析zh_TW
dc.typeThesis
dc.date.schoolyear93-2
dc.description.degree碩士
dc.contributor.oralexamcommittee陳博光,吳興盛
dc.subject.keyword人工椎間盤,有限元素法,腰椎,替代物,zh_TW
dc.subject.keywordartificial disc,finite element,lumbar,en
dc.relation.page79
dc.rights.note有償授權
dc.date.accepted2005-07-26
dc.contributor.author-college工學院zh_TW
dc.contributor.author-dept機械工程學研究所zh_TW
顯示於系所單位:機械工程學系

文件中的檔案:
檔案 大小格式 
ntu-94-1.pdf
  未授權公開取用
1.4 MBAdobe PDF
顯示文件簡單紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved