Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 電機資訊學院
  3. 電機工程學系
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/29111
完整後設資料紀錄
DC 欄位值語言
dc.contributor.advisor郭德盛
dc.contributor.authorJin-Kae Jangen
dc.contributor.author張津愷zh_TW
dc.date.accessioned2021-06-13T00:40:40Z-
dc.date.available2012-07-27
dc.date.copyright2007-07-27
dc.date.issued2007
dc.date.submitted2007-07-25
dc.identifier.citationAkin, A, and Sun, HH, Time-frequency methods for detecting spike activity of stomach. Med. Biol. Eng. Comput. 1999; 37: 381–390.
Akin, A, and Sun, HH, Non-invasive gastric motility monitor: fast electrogastrogram (fEGG). Physiol. Meas. 2002; 23: 505–19.
Alvarez, WC, The electrogastrogram and what it shows. J. Am. Med. Assoc. 1921; 78:1116–1119.
Bagwell, PJ, and Chappell PH, Real time microcontroller implementation of an adaptive myoelectric filter. Med. Eng. Phys. 1995; 17: 151-160.
Bieger-Farhan, AK, Chadha, NK, Camilleri, AE, Stone, P, and McGuinness, K, Portable method for the determination of snoring site by sound analysis. J. Laryngol. Otol. 2004; 118: 135-138.
Bortoff, A, Michaels, D, and Mistretta, P, Dominance of longitudinal muscle in propagation of intestinal slow waves. Am. J. Physiol.: Cell Physiol. 1981; 240: C135–C147.
Bortolotti, M, Annese, V, and Coccia, G, Twenty-four hour ambulatory antroduodenal manometry in normal subjects (co-operative study). Neurogastroenterol. Motil. 2000; 12: 231-238.
Chen, C-L, Hu, Ci-T, Lin, H-H, and Yi, C-H, Clinical utility of electrogastrography and the water load test in patients with upper gastrointestinal symptoms. J. Smooth. Muscle Res. 2006; 42: 149-157.
Chen, J, Yeaton, P, and McCallum RW, Effect of erythromycin on gastric myoelectrical activity in normal human subjects. Am. J. Physiol., 1992; 263: G24-G28.
Chen, J, McCallum, RW, and Richards, R, Frequency components of the electrogastrogram and their correlations with gastrointestinal contractions in humans. Med. Biol. Eng. Comput. 1993; 31: 60-57.
Chen, J-Y, Assistant system for evaluation of the gastric motility-Gastric Sound measurement. Master thesis, National Taiwan University 2003.
Chu, K.-C., Evaluation of EGG Parameters and ultrasound measurement. Master thesis, National Taiwan University 2001.
Daskalov, I, Christov, I, and Kolev, V, High-pass filtering of the electrogastrogram. Med. Biol. Eng. Comput. 1997; 35: 279-282.
Evenson, KR, Welch, VL, Cascio, WE, and Simpson, RJ Jr, Validation of a short rhythm strip compared to ambulatory ECG monitoring for ventricular ectopy. J. Clin. Epidemiol. 2000; 53: 491-497.
Forbes, AD, and Helfenbein, ED, Intramyocardial anomalous activity detection by subtracting modeled respiratory effect. U.S.Patent 6132381, 2000.
Guler, NF, and Hardalac, F, Design of microcontroller-based EMG and the analysis of EMG signals. J. Med. Syst. 2002; 26: 151-157.
Hansson, GA, Asterland, P, and Kellerman, M, Modular data logger system for physical workload measurements. Ergonomics 2003; 46: 407-415.
Hu, S, Grant, WF, Stern, RM, and Koch, KL, Motion sickness severity and physiological correlates during repeated exposures to a rotating optokinetic drum. Aviat. Space Environ. Med. 1991; 62: 308-314.
Huang, NE, Shen, Z, Long, SR, Wu, MC, Shih, HH, Zheng, Q, Yen, N, Tung, CC, and Liu, HH, The Empirical Mode Decomposition and the Hilbert Spectrum for Nonlinear and Non-stationary Time Series Analysis. Proc. R. Soc. Lond. A 1998; 454: 903-995.
Ibrahimy, MI, Ahmed, F, Mohd, AMA, and Zahedi, E, Real-time signal processing for fetal heart rate monitoring. IEEE Trans. Biomed. Eng. 2003; 50: 258-262.
Irimia, A, Richards, WO, and Bradshaw, LA, Magnetogastrographic detection of gastric electrical response activity in humans. Phys. Med. Biol. 2006; 51: 1347–1360.
Jang, JK, Kuo, TS, and Shieh, MJ, Microcontroller-based EGG recording system. Biomed. Eng. Appl. Basis Comm. 2001; 13: 226-230.
Jang, JK, Shieh, MJ, Kuo, TS, and Jaw, FS, Portable EGG recording system based on a digital voice recorder. J Med. Eng. Technol. 2007; accepted.
Jaw, FS, Optimal sampling of electrophysiological signals. Neurosci. Res. Commun. 2001; 28: 75–84.
Jovanov, E, Raskovic, D, and Hormigo, R, Thermistor-based breathing sensor for circadian rhythm evaluation. Biomed. Sci. Instrum. 2001; 37: 493-497.
Koch, KL, Stern, RM, Stewart, WR, Vasey, MW, and Sullivan, ML, Gastric emptying and gastric myoelectrical activity in patients with symptomatic diabetic gastroparesis: effect of long-term domperidone treatment. Am. J. Gastroenterol. 1989; 84: 1069-1075.
Koch, KL, Illusory self-motion and motion sickness: a model for brain-gut interactions and nausea. Dig. Dis. Sci. 1999; 44: 53S-57S.
Lathi, BP, Modern Digital and Analog Communication Systems (New York: Oxford) 1998.
Lindberg, G, Iwarzon, M, and Hammarlund, B, 24-hour ambulatory electrogastrography in healthy volunteers. Scand. J. Gastroenterol. 1996; 31: 658-664.
Naszlady, A, and Naszlady, J, Patient health record on a smart card. Int. J. Med. Inform. 1998; 48: 191-194.
McCreesh, Z, Evans, NE, and Scanlon WG, Vaginal temperature sensing using UHF radio telemetry. Med. Eng. Phys. 1996; 18: 110-114.
MettingVanRijn, AC, Peper, A, and Grimbergen, CA, Amplifiers for bioelectric events: a design with a minimal number of parts. Med. Biol. Eng. Comput. 1994; 32: 305–310.
Neuman, MR, Biopotential electrodes. In: J.G. Webster (Ed.) Medical Instrumentation: application and design (Hoboken: John Wiley & Sons Inc) 1998.
Orr, WC, Crowell, MD, Lin, B, Harnish, MJ, and Chen, JDZ, Sleep and gastric function in irritable bowel syndrome derailing the brain-gut axis. GUT 1997; 41: 390-393.
Penning, C, Gielkens, HA, Hemelaar, M, Lamers, CB, and Masclee, AA, Reproducibility of antroduodenal motility during prolonged ambulatory recording. Neurogastroenterol. Motil. 2001; 13: 133-141.
Saidi, AS, Moodie, DS, Garson, A Jr, Lipshultz, SE, Kaplan, S, Lai, WW, Colan, SD, Starc, TJ, Shanbhag, S, Easley, KA, and Bricker, JT, Electrocardiography and 24-hour electrocardiographic ambulatory recording (Holter monitor) studies in children infected with human immunodeficiency virus type 1. The Pediatric Pulmonary and Cardiac Complications of Vertically Transmitted HIV-1 Infection Study Group. Pediatr. Cardiol. 2000; 21: 189-196.
Sakagami, R, Horii, T, Ino, S, Matoba, K, Kato, H, and Kawanami, M, Development of a portable bruxism monitoring and analysis device equipped with a microcomputer and its practical application. Front. Med. Biol. Eng. 2002; 11: 295–306.
Schuster, MM, Atlas of Gastrointestinal Motility in Health and Disease (Baltimore: Williams & Wilkins) 1993.
Smit, HW, Verton, K, and Grimbergen, CA, A low-cost multichannel preamplifier for physiological signals. IEEE Trans. Biomed. Eng. 1987; 34: 307-310.
Smout, AJ, van der Schee, EJ, and Grashuis, JL, What is measured in electrogastrography? Dig. Dis. Sci. 1980; 25: 179-187.
Smout, AJ, Jebbink, HJA, and Samson, M, Acquisition and analysis of electrogastrographic data. In: J.D. Chen (Ed.) Electrogastrography Principle and Aplications (New York: Raven Press Ltd) 1994.
Spinelli, EM, Martinez, NH, and Mayosky, MA, A single supply biopotential amplifier. Med. Eng. Phys. 2001; 23: 235-238.
Spinelli, EM, Martinez, NH, and Mayosky, MA, A transconductance driven-right-leg circuit. IEEE Trans. Biomed. Eng. 1999; 46: 1466-1470.
Verghagen, MA, Samsom, M, and Smout, JP, Effects of intraduodenal glucose infusion on gastric myoelectrical activity and antropyloroduodenal motility. Am. J. Physiol. 1998; 274: G1038-G1044.
Wang, Z, He, Z, and Chen, J, Filter banks and neural network-based feature extraction and automatic classification of electrogastrogram. Ann. Biomed. Eng. 1999; 27: 88-95.
Waterhouse, E, New horizons in ambulatory electroencephalography. IEEE Eng. Med. Biol. Mag. 2003; 22: 74-80.
Winter, BB, and Webster, JG, Driven-right-leg circuit design. IEEE Trans. Biomed. Eng. 1983; 30: 62-66.
Zucconi, M, Caprioglio, A, Calori, G, Ferini-Strambi, L, Oldani, A, Castronovo, C, and Smirne, S, Craniofacial modifications in children with habitual snoring and obstructive sleep apnoea: a case-control study. Eur. Respir. J. 1999; 13: 411-417.
Zhou, M, Zhang, H, Shaw, R, and Barnes, FS, Real-time Multi-channel computerized Electrograph. IEEE Trans. Biomed. Eng. 1997; 44: 1228-1236.
dc.identifier.urihttp://tdr.lib.ntu.edu.tw/jspui/handle/123456789/29111-
dc.description.abstract表皮胃電圖(EGG)是一種經由表皮電極,對胃的電氣活動非侵入性的量測,是胃的活動力指標,通常用於有消化功能性障礙病人的診察。功能性障礙可能是胃部肌肉或是控制肌肉的神經異常,胃電記錄可以協助臨床醫師診察噁心或想吐等功能性疾病,為了進行胃電的研究,本論文設計了一組床邊胃電記錄系統與其擷取及分析程式。
攜帶型生理信號系統對陣發性或突發性症狀的偵測及診斷有其重要性,經由長時間以攜帶方式來記錄信號,臨床醫師和研究者將更有機會來記錄到這些急性症狀,基於床邊胃電記錄系統的設計經驗,本文也設計了兩款攜帶型胃電記錄器。第一組是以微控制器為主的模組式記錄器,並在其上建構了記錄胃電(EGG)、心電圖(ECG)、以及腦電圖(EEG)的子板,是一模組化多功能生理信號記錄器。第二組是利用數位錄音棒來進行胃電記錄,我們設計了一個小型的電路模組,要讓一般市面上的數位錄音棒,可以記錄極低頻的胃電信號。而這兩組記錄器的設計都是小型化且低耗電的設計,很適合進行長時間生理信號的攜帶式記錄。
本文並以床邊胃電記錄系統配合超音波影像探討在胃排空時胃電與其之關係。由超音波影像量測到胃的體積變化,可以觀察到胃的排空(體積由大變小),而胃電的主頻率之功率變化和超音波影像一致,對胃排空有相同的變化趨勢。我們也使用床邊記錄系統,探討胃音和胃電的關係,從研究結果可以得知,在胃音發生時,胃電的主頻率將明顯降低而主頻率之功率則會有明顯的增加。
zh_TW
dc.description.abstractCutaneous electrogastrogram (EGG) is the electrical activity of the stomach. It is a non-invasive measurement via cutaneous electrodes. EGG is considered to be a motility index to of the stomach. A recording of EGG is usually used when a patient is suspected of having a functional disorder. The functional disorder means that the muscles of the stomach or the nerves controlling the muscles do not work as they should be. The EGG can help clinicians to diagnose the cause of chronic nausea and vomiting they are functional disorder of the stomach. For studying EGG signal, an EGG bedside recording system in addition to the software for acquisition and analysis was created.
Ambulatory recording systems for biomedical signals are very important in detecting and diagnosing paroxysmal attack or sudden onset of symptoms. With a long-term ambulatory recording of signals, researchers and clinicians could have more opportunities to investigate and analyse these acute symptoms. Based on the experiences of the bedside EGG recording system, two types of portable EGG recorders were designed in this thesis. First one was designed based on a microcontroller. This portable recorder is a modular design, which contains a motherboard and daughterboards for the recording of electrogastrogram (EGG), electrocardiogram (ECG), and electroencephalogram (EEG) signals. The second one was based on a digital voice recorder. A compact circuit was designed to make the commercial audio recording device being able to record the low frequency EGG. Both of them are compact dimension yet low power consumption. They are suitable for long-term portable recording of biomedical signals.
Based on our bedside EGG system and the ultrasonic image of the stomach, the relationship between the emptying and the EGG was studied. The decrease in volume measured by the ultrasound showed the gastric emptying, while the power of the dominant frequency displayed the same trend as the ultrasonic measurement. We also use this system to study the relationship of gastric sound and EGG. The result showed that the dominant frequency decreased and the dominant power increased when the gastric sound appeared.
en
dc.description.provenanceMade available in DSpace on 2021-06-13T00:40:40Z (GMT). No. of bitstreams: 1
ntu-96-D87921038-1.pdf: 2036774 bytes, checksum: 0ace6610a35f84fc0171db7d963bcd91 (MD5)
Previous issue date: 2007
en
dc.description.tableofcontents中文摘要 ……………………………………………………… I
ABSTRACT ……………………………………………………… II
LIST OF FIGURES …………………………………………… VI
LIST OF TABLES …………………………………………… VIII
1. INTRODUCTION …………………………………………… 1-1
2. RECORDING SYTEMS ……………………………………… 2-1
2.1. Bed side EGG recording system……………………… 2-3
2.1.1. Design concept ……………………………… 2-3
2.1.2. System design ……………………………… 2-4
2.1.2.a. Amplifiers and filters ………………………… 2-4
2.1.2.b. Digital circuit ……………………………… 2-5
2.1.2.c. Software design ……………………………… 2-6
2.1.2.d. EGG measurement ……………………………… 2-6
2.1.3. Result …………………………………………… 2-7
2.1.4. Discussion ………………………………………… 2-7
2.2. Modular design for Portable signal recording… 2-15
2.2.1. Design concept ……………………………… 2-15
2.2.2. System design ……………………………… 2-16
2.2.2.a. Motherboard ……………………………… 2-16
2.2.2.b. Modularized signal conditioning ……… 2-18
2.2.2.c. Interface to host computer ………………… 2-19
2.2.3. Result …………………………………………… 2-20
2.2.4. Discussion …………………………………………… 2-20
2.3. Portable EGG recording system based on a DVR…… 2-28
2.3.1. Design concept ……………………………… 2-28
2.3.2. System design ……………………………… 2-29
2.3.3. Practical application of the system…………… 2-33
2.3.4. Discussion …………………………………………… 2-34
3. APPLICATIONS……………………………………………… 3-1
3.1. Ultrasound measurement vs. EGG ………………… 3-1
3.1.1. Motivation ………………………………………… 3-1
3.1.2. Experiment & protocol …………………………… 3-2
3.1.3. Results & discussion ……………………………… 3-3
3.2. Gastric sound measurement vs. EGG ……………… 3-11
3.2.1. Motivation ………………………………………… 3-11
3.2.2. Experiment setup ……………………………… 3-11
3.2.3. Results & discussion ……………………………… 3-12
4. CONCLUSION ………………………………………… 4-1
REFERENCES ………………………………………… A-1
dc.language.isoen
dc.title可攜式記錄系統- 胃電之應用zh_TW
dc.titlePortable Recording System- for Electrogastrogram Applicationen
dc.typeThesis
dc.date.schoolyear95-2
dc.description.degree博士
dc.contributor.coadvisor趙福杉,謝銘鈞
dc.contributor.oralexamcommittee曹恆偉,黃基礎,鄭國順,謝建興,王正一,楊順聰
dc.subject.keyword攜帶式記錄,微控制器,胃電圖,放大器,濾波器,數位錄音棒,zh_TW
dc.subject.keywordportable recording,microcontroller,Electrogastrogram,amplifier,filter,DVR,en
dc.relation.page84
dc.rights.note有償授權
dc.date.accepted2007-07-25
dc.contributor.author-college電機資訊學院zh_TW
dc.contributor.author-dept電機工程學研究所zh_TW
顯示於系所單位:電機工程學系

文件中的檔案:
檔案 大小格式 
ntu-96-1.pdf
  目前未授權公開取用
1.99 MBAdobe PDF
顯示文件簡單紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved