請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/27975
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 林立德(Li-Deh Lin) | |
dc.contributor.author | Wei-Li Cheng | en |
dc.contributor.author | 鄭偉立 | zh_TW |
dc.date.accessioned | 2021-06-12T18:31:09Z | - |
dc.date.available | 2007-08-08 | |
dc.date.copyright | 2007-08-08 | |
dc.date.issued | 2007 | |
dc.date.submitted | 2007-08-01 | |
dc.identifier.citation | 1. Adrian ED. Ivanhoe JR. Krantz WA. Trajectory surgical guide stent for implant placement. J Prosthet Dent 1992;67:687-91.
2. Allen F, Smith DG. An assessment of the accuracy of ridge-mapping in planning implant therapy for the anterior maxilla. Clin Oral Implants Res 2000;11:34–38. 3. Almog DM. Torrado E. Moss ME. Meitner SW. LaMar F. Use of imaging guides in preimplant tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2002;93:483-7. 4. Almog DM. Torrado E. Meitner SW. Fabrication of imaging and surgical guides for dental implants. J Prosthet Dent 2001;85:504-8. 5. Almog DM. Sanchez R. Correlation between planned prosthetic and residual bone trajectories in dental implants. J Prosthet Dent 1999;81:562-7. 6. Akca K. Iplikcioglu H. Cehreli MC. A surgical guide for accurate mesiodistal paralleling of implants in the posterior edentulous mandible. J Prosthet Dent 2002;87:233-5. 7. Atsu SS. A surgical guide for dental implant placement in edentulous posterior regions. J Prosthet Dent 2006;96:129-33. 8. Basten CHJ. The use of radiopaque templates for predictable implant placement. Quintessence Int 1995;26:609-612. 9. Becker CM. Kaiser DA. Surgical guide for dental implant placement. J Prosthet Dent 2000;83:248-51. 10. Belser U. Mericske RD. Bernard JP. Taylor TD. Prosthetic management of the partially dentate patient with fixed implant restorations. Clin Oral Implants Res 2000;11:126–145. 11. Besimo CE. Lambrecht JT. Guindy JS. Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography. Dentomaxillofac Radiol 2000;29:46–51. 12. Besimo, C. Lambrecht JT. Nidecker A. Dental implant treatment planning with reformatted computed tomography. Dentomaxillofac Radiol 1995; 4:264–267. 13. Birkfellner W. Solar P. Gahleitner A. Huber K. Kainberger F. Kettenbach J. Homolka P. Diemling M. Watzek G. Bergmann H. In-vitro assessment of a registration protocol for image guided implant dentistry. Clin Oral Implants Res 2001;12:69–78. 14. Blanchet E. Lucchini JP. Jenny R. Fortin T. An Image-Guided System Based on Custom Templates: Case Reports. Clin Implant Dent Related Res 2004; 6(1):40-47. 15. Borrow JW. Smith JP. Stent marker materials for computerized tomograph- assisted implant planning. Int J Periodont Rest Dent 1996;16:60- 7. 16. Bou Serhal C. Jacobs R. Persoon M. Hermans R. Van Steenberghe D. The Accuracy of Spiral Tomography to Assess Bone Quality for the Preoperative Planning of Implants in the Posterior Maxilla. Clin Oral Implants Res 2000;11:242-247. 17. Butterfield KJ. Dagenais M. Clokie C. Linear tomography's clinical accuracy and validity for presurgical dental implant analysis. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1997;84:203-9. 18. Campelo LD. Camara JRD. Flapless implant surgery: A 10-year clinical retrospective analysis. Int J Oral Maxillofac Implants 2002;17:271–276. 19. Çehreli MC. Sahin S. Fabrication of a dual-purpose surgical template for correct labiopalatal positioning of dental implants. Int J Oral Maxillofac Implants 2000;15:278-82. 20. Çehreli MC. Aslan Y. Sahin S. Bilaminar dual-purpose stent for placement of dental implants. J Prosthet Dent 2000;84:55-8. 21. Çehreli MC. Çalis AC.Sahin S. A dual-purpose guide for optimum placement of dental implants. J Prosthet Dent 2002;88:640-3. 22. Chiche GJ. Block MS. Pinault A. Implant surgical template for partially edentulous patients. Int J Oral Maxillofac Implants 1989;4:289-92. 23. Chiu WK. Luk WK. Cheung LK. Three-Dimensional Accuracy of Implant Placement in A Computer-Assisted Navigation System. Int J Oral Maxillofac Implant 2006;21:465-470. 24. Choi JY. Choi JH. Kim NK. Kim Y. Lee JK. Kim MK. Lee JH. Kim MJ. Analysis of errors in medical rapid prototyping models. Int J Oral Maxillofac Surg 2002;31:23–32. 25. Dixon DR. Morgan R. Hollender LG. Roberts FA. O’Neal RB. Clinical Application of Spiral Tomography in Anterior Implant Placement: Case Report. J Periodontol 2002;73:1202-1209. 26. Di Giacomo GAP. Cury PR. de Araujo NS. Sendyk WR. Sendyk CL. Clinical Application of Stereolithographic Surgical Guides for Implant Placement: Preliminary Results. J Periodontol 2005;76:503-507. 27. Duckmanton N. Austin BW. Lechner SK. Klineberg IJ. Imaging for predictable maxillary implants. Int J Prosthodont 1994;7:77-80. 28. Dula K. Mini R. van der Stelt PF. Buser D. The radiographic assessment of implant patients: Decision-making criteria. Int J Oral Maxillofac Implants 2001;16:80–89. 29. Eckert SE. Laney WR. Patient evaluation and prosthodontics treatment planning for osseointegrated implants. Dent Clin N Am 1989;33: 599-618. 30. Engelman MJ. Sorensen JA. Moy P. Optimum placement of osseointegrated implants. J Prosthet Dent 1988;59:467-73. 31. Ewer R. Schicho K. Truppe M. Seemann R. Reichwein A. Figl M. Wagner A. Computer-Aided Navigation in Dental Implantology: 7 Years of Clinical Experience. J Oral Maxillofac Surg 2004;62:329-334. 32. Ewer R. Schicho K. Undt G. Wanschitz F. Truppe M. Seemann R. Wagner A. Basic research and 12 years of clinical experience in computer-assisted navigation technology: a review. J Oral Maxillofac Surg 2005;34:1-8. 33. Fortin T. Isidori M. Blanchet E. Perriat M. Bouchet H. Coudert JL. An Image-Guided System–Drilled Surgical Template and Trephine Guide Pin to Make Treatment of Completely Edentulous Patients Easier: A Clinical Report on Immediate Loading. Clin Implant Dent Related Res 2004;6(2):111-119. 34. Fortin T. Champleboux G. Bianchi S. Buatois H. Coudert JL. Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine: An in vitro study. Clin Oral Implants Res 2002;13:651–656. 35. Fortin T. Bosson JL. Coudert JL.Isidori M. Reliability of Preoperative Planning of an Image-Guided System for Oral Implant Placement Based on 3-dimensional Images: An In Vivo Study. Int J Oral Maxillofac Implants 2003;18:886–893. 36. Fortin T. Champleboux G. Lorme´e J. Coudert JL. Precise dental implant placement on bone using surgical guides in conjunction with medical imaging techniques. J Oral Implantol 2000;2:300–303. 37. Ganz Scott D. Techniques for the use of CT imaging for the fabrication of surgical guides. Atlas Oral Maxillofac Surg Clin N Am 2006;14 (1):75-97. 38. Ganz Scott D. Use of Stereolithographic Models As Diagnostic And Restorative Aids For Predictable Immediate Loading Of Implants. Pract Proced Aesthet Dent 2003;15(10):763-771. 39. Garber DA, Belser UC. Restoration-driven implant placement with restoration- generated site development. Compend Contin Educ Dent 1995;16:796-804. 40. Garg AK. Computed Tomography: Reducing the Cost and Increasing the Effectiveness of Dental Implantology. Dental Implantol Update 2005;16(8):57-64. 41. Gher ME. Richardson AC. The accuracy of dental radiographic techniques used for evaluation of implant fixture placement. Int J Periodontics Restorative Dent 1995;15:268–283. 42. Guerrero ME. Jacobs R. Loubele M. Schutyser F. Suetens P. van Steenberghe D. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement. Clin Oral Invest 2006;10:1–7. 43. Harris D. Buser D. Dula K. European Association for Osseointegration guidelines for the use of diagnostic imaging in implant dentistry. Clin Oral Implants Res 2002;13:566–570. 44. Hassfeld S. Muhling J. Computer assisted oral and maxillofacial surgery—a review and an assessment of technology. Int J Oral Maxillofac Surg 2001:30:2–13. 45. Hassfeld SM. Muhling J. Zoller J. Intraoperative navigation in oral and maxillofacial surgery. Int J Oral Maxillofac Surg 1995;24:111–119. 46. Hoffmann J. Westendorff C. Schneider M. Reinert S. Accuracy Assessment of Image-Guided Implant Surgery: An Experimental Study. Int J Oral Maxillofac Implants 2005;20:382-386. 47. Israelson H. Plemons JM. Watkins P. Sory C. Barium-coated surgical stents and computer-assisted tomography in the preoperative assessment of dental implant patients. Int J Periodontics Restorative Dent 1992;12:52–61. 48. Jacobs R. Preoperative Radiologic Planning of Implant Surgery in Compromised Patient. Periodontol 2000 2003;33:12-25. 49. Jacobs R. Adriansens A. Naert I. Quirynen M. Hermans R. van Steenberghe D. Predictability of reformatted computed tomography for pre-operative planning of endosseous implants. Dentomaxillofac Radiol 1999;28:37–41. 50. Jacobs R. Adriansens A. Verstreken K. Suetens P. van Steenberghe D. Predictability of a three-dimensional planning system for oral implant surgery. Dentomaxillofac Radiol 1999;28:105–111. 51. Jacotti M. Simplified Onlay Grafting with a 3-dimensional Block Technique: A Technical Note. Int J Oral Maxillofac Implants 2006; 21:635-639. 52. Kennedy BD. Collins TA. Kline PCW. Simplified guide for precise implant placement: a technical note. Int J Oral Maxillofac Implants 1998;13:684–688. 53. Klein M. Abrams M. Computer-guided surgery utilizing a computer-milled surgical template. Pract Proced Aesthet Dent 2001; 13:165–169. 54. Kopp KC. Koslow AH. Abdo OS. Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. J Prosthet Dent 2003;89:611-5. 55. Koyanagi K. Development and clinical application of a surgical guide for optimal implant placement. J Prosthet Dent 2002;88:548-52. 56. Lal K. White G.S. Morea D.N. Wright R.F. Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. J Prosthodont 2006;15(1):51-58. 57. Lal K. White G.S. Morea D.N. Wright R.F. Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part II. A Clinical Report. J Prosthodont 2006;15(2): 117-122. 58. Marmulla R. Hilbert M. Niederdellmann H. Inherent precision of mechanical, infrared and laser-guided navigation systems for computer-assisted surgery. J Craniomaxillofac Surg 1997;25:192–197. 59. Marmulla R. Hassfeld S. Lüth T. Mühling J. Laser-scan-based navigation in cranio-maxillofacial surgery. J Craniomaxillofac Surgery 2003;31:267-277. 60. Marmulla R. Mühling J. The Influence of Computed Tomography Motion Artifacts on Computer-Assisted Surgery. J Oral Maxillofac Surg 2006; 64:466-470. 61. Meyer U. Wiesmann H.P. Runte C. Meier N. Joos U. Evaluation of accuracy of insertion of dental implants and prosthetic treatment by computer-aided navigation in minipigs. British J Oral Maxillofac Surg 2003;41:102-108. 62. Minoretti R. Merz BR. Triaca A. Predetermined implant positioning by means of a novel guide template technique. Clin Oral Implants Res 2000;11: 266–272. 63. Miyamoto M. Ichikawa T. Horiuchi M. Okamoto Y. Pilot hole preparation: technical note presenting a new technique for proper implant positioning. Int J Oral Maxillofac Implants 1994;9:319–325. 64. Mizrahi B. Thunthy KH. Finger I. Radiographic/surgical template incorporating metal telescopic tubes for accurate implant placement. Pract Periodontics Aesthet Dent 1998;10:757–765. 65. Naitoh M. Ariji E. Okumura S. Ohsaki C. Kurita K. Ishigami T. Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants? Clin Oral Impl Res 2000;11: 409–414. 66. Quirynen M. Lamoral Y. Dekeyser C. Peene P. Steenberghe D.V. Bonte J. & Baert AL. The CT scan standard reconstruction technique for reliable jaw bone volume determination. Int J Oral Maxillofac Implants 1990;5:384–389. 67. Pesun IJ. Gardner FM. Fabrication of a guide for radiographic evaluation and surgical placement of implants. J Prosthet Dent 1995; 73:548-52. 68. Rabbe A. Krishnan R. Wolff R. Hermann E. Zimmermann M. Seifert V. Laser Surface Scanning for Patient Registration in intracranial Image-guided Surgery. Neurosurg 2002;50:797-803. 69. Reddy MS. Mayfield-Donahoo T. Vanderven FJJ. Jeffcoat MK. A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implants. Clin Oral Implant Res 1994;5:229-238. 70. Reiskin AB. Implant Imaging. Dent Clin N Am 1998;42:47-56. 71. Rosenfeld AL. Mandelaris GA. Tardieu PB. Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 1: Diagnostics, imaging, and collaborative accountability. Int J Periodontics Restorative Dent 2006;26(3):215-221. 72. Rosenfeld AL. Mandelaris GA. Tardieu PB. Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 2: Rapid-prototype medical modeling and stereolithographic drilling guides requiring bone exposure. Int J Periodontics Restorative Dent 2006;26(4):347-353. 73. Rosenfeld AL. Mandelaris GA. Tardieu PB. Prosthetically Directed Implant Placement Using Computer Software to Ensure Precise Placement and Predictable Prosthetic Outcomes. Part 3: Stereolithographic Drilling Guides That Do Not Require Bone Exposure and the Immediate Delivery of Teeth. Int J Periodontics Restorative Dent 2006;26(5):493-499. 74. Rothman SLG. Chaftez N. Rhodes ML. Schwarz MS. CT in the preoperative assessment of the mandible and the maxilla for endosseous implant surgery. Radiol 1988;168:171–175. 75. Sarment DP. Al-Shammari K. Kazor CE. Stereolithographic Surgical Templates for Placement of Dental Implants in Complex Cases. Int J Periodontics Restorative Dent 2003;23:287–295. 76. Sammartino G. Della Valle A. Marenzi G. Gerbino S. Martorelli M. di Lauro A E. di Lauro F. Stereolithography in Oral Implantology A Comparison of Surgical Guides. Implant Dent 2004;13:133–139. 77. Santler G. Kärcher H. Ruda C. Indications and limitations of three-dimensional models in cranio-maxillofacial surgery. J Craniomaxillofac Surg 1998; 26 :11-16. 78. Scarfe WC. Farman AG. Sukovic P. Clinical applications of cone-beam computed tomography in dental practice. J Can Dent Assoc 2006;72(1):75-80. 79. Schwarz MS. Rothman SLG. Rhodes ML. Chafetz N. Computed tomography. Part I: Preoperative assessment of the mandible for endosseous implant surgery. Int J Oral Maxillofac Implants 1987;2:137–141. 80. Schwarz MS. Rothman SLG. Rhodes ML. Chafetz N. Computed tomography. Part II: Preoperative assessment of the maxilla for endosseous implant surgery. Int J Oral Maxillofac Implants 1987;2:143–148. 81. Sehti A. Precise site location for implants using CT scans: a technical note. Int J Oral Maxillofac Implants 1993;8:433–438. 82. Shotwell JL. Billy EJ. Wang HL. Oh TJ. Implant surgical guide fabrication for partially edentulous patients. J Prosthet Dent 2005;93:294-7. 83. Sicilia A. Noguerol B. Cobo J. Zabalegui I. Profile surgical template: a systematic approach to precise implant placement. A technical note. Int J Oral Maxillofac Implants 1998;13:109–114. 84. Sieβegger M. Schneider BT. Mischkowski RA. Lazar F. Krug B. Klesper B. Zöller JE. Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites. J Craniomaxillofac Surg 2001; 29:276-281. 85. Simon H. Use of transitional implants to support a surgical guide: Enhancing the accuracy of implant placement. J Prosthet Dent 2002;87:229-32. 86. Solow RA. Simplified radiographic-surgical template for placement of multiple, parallel implants. J Prosthet Dent 2001;85:26-9. 87. Takeshita F. Suetsugu T. Accurate presurgical determination for implant placement by using computerized tomography scan. J Prosthet Dent 1996; 76:590-1. 88. Tardieu P. Vrielinck L. Escolano E. Computer-assisted implant placement. A case report: treatment of the mandible. Int J Oral Maxillofac Implants 2003; 18:599–604. 89. Tsuchida F. Suetsugu T. Accurate presurgical determination for implant placement by using computerized tomography scan. J Prosthet Dent 1996;76:590-1. 90. Tsuchida F. Hosoi T. Imanaka M. Kobayashi K. A technique for making a diagnostic and surgical template. J Prosthet Dent 2004;91:395-7. 91. Todd AD. Gher ME. Quintero G. Richardson AC. Interpretation of linear and computed tomograms in the assessment of implant recipient sites. J Periodontol 1993;64:1243–1249. 92. Valente AF. Sbrenna A. Buoni C. CAD CAM drilling guides for transferring CT-based digital planning to flapless placement of oral implants in complex cases. Int J Comput Assist Radiol Surg 2006;(1) Suppl 1:413-415. 93. Vannier MW. Hildebolt CF. Conover G. Knapp RH. Naoko YC. Wang Ge. Three-dimensional dental imaging by spiral CT: A progress report. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1997;84:561-570. 94. Van Steenberghe D. Naert I. Andersson M. Brajnovic I. Van Cleynenbreugel J. Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants 2002;17:663–670. 95. Van Steenberghe D. Malavez C. Van Cleynenbreugel J. Accuracy of drilling guides for transfer from three-dimensional CT-based planning to placement of zygoma implants in human cadavers. Clin Oral Implants Res 2003;14:131–136. 96. Verstreken K. Van Cleynenbreugel J. Marchal G. Nert I. Suetens P. Van Streenberghe D. Computer-assisted planning of oral implant surgery: a three dimensional approach. Int J Oral Maxillofac Implants 1996;11: 806–810. 97. Verde MA. Morgano SM. A dual-purpose stent for the implant-supported prosthesis. J Prosthet Dent 1993;69:276-80. 98. Vrielinck L. Politis C. Schepers S. Pauwels M. Naert I. Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. Int J Oral Maxillofac Surg 2003;32:7–14. 99. Wagner A. Wanschitz F. Birkfellner W. Zauza K. Watzinger F. Schicho K. Kainberger F. Czerny C. Bergmann H. Ewers R. Computer-aided placement of endosseous oral implants in patients after ablative tumor surgery: assessment of accuracy. Clin Oral Implants Res 2003; 14:340–348. 100. Wagner A. Schicho K. Birkfellner W. Figl M. Seemann R. Konig F. Kainberger F. Ewers R. Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems. Med Phys 2002;29:905–912. 101. Wagner A. Ploder O. Enislidis G. Truppe M. Ewers R. Image-guided surgery. Int J Oral Maxillofac Surg 1996; 25:147–151. 102. Watzinger F. Wanschitz F. Wagner A. Enislidis G. Millesi W. Baumann A. Ewers R. Computer-aided navigation in secondary reconstruction of post-traumatic deformities of the zygoma. J Craniomaxillofac Surg 1997;25:198-202. 103. Watzinger F. Birkfellner W. Wanschitz F. Positioning of dental implants using computer-aided navigation and an optical tracking system: Case report and presentation of a new method. J Craniomaxillofac Surg 1999;27:77-81. 104. Wanschitz F. Birkfellner W. Watzinger F. Schopper C. Patruta S. Kainberger F. Figl M. Kettenbach J. Bergmann H. Ewers R. Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible. Clin Oral Implants Res 2002;13:59–64. 105. Wanschitz F. Birkfellner W. Figl M. Patruta S. Wagner A. Watzinger F. Yerit K. Schicho K. Hanel R. Kainberger F. Imhof H. Bergmann H. Ewers R. Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery. Clin Oral Implants Res 2002;13: 610–616. 106. Weinberg LA. CT scan as a radiologic data base for optimum implant orientation. J Prosthet Dent 1993;69:381-5. 107. Wells WM. Viola P. Atsumi H. Nakajima S. Kikinis R. Multi-modal volume registration by maximization of mutual information. Med Image Analy 1996;1:35–51. 108. Widmann G. Bale R.J. Accuracy in Computer-Aided Implant Surgery—A Review. Int J Oral Maxillofac Implants 2006;21:305-313. 109. Widmann G. Widmann R. Widmann E. Jaschke W. Bale R. Use of a Surgical Navigation System for CT-Guided Template Production. Int J Oral Maxillofac Implant 2007;22:72-78. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/27975 | - |
dc.description.abstract | 人工植牙是從60 年代才開始發展的新技術。它是將一鈦金屬人工牙根植入上、下顎骨,讓骨組織和植入的植體產生所謂的骨整合,之後再於癒合好的人工牙根上方置入牙科補綴物。相較於傳統的活動假牙,穩定性較好,病人的接受度也較高,因此近年來尋求植牙治療的病人也越來越多。然而植牙治療的成功與否,除了和植入的植體有無成功的達到骨整合外,也和植體植入的位置、角度及方向有關,唯有精確的將人工牙根植入術前預計的位置,才能成功的將上方的補綴物回復到理想的狀態,達到美觀及功能的要求。
許多電腦輔助植牙技術的應用,即是希望將術前計劃植體植入的位置,成功的轉移至手術過程中,確保將來補綴物製作能達到當初預期的結果。包括電腦導航式手術和電腦輔助設計手術模板的製作,都是為了達到上述目的而發展出的技術。目前市面上充斥各式各樣的商品,宣稱其產品能準確的將術前計劃轉移至手術過程,然而其精密度並未被審慎的評估,而且往往因價格昂貴而無法廣泛的應用在植牙的評估與治療。 在本實驗中,我們使用可重覆置換缺牙區塊的上顎模型,利用金屬套筒導引式的手術模板,來模擬植牙手術的進行。影像的擷取則採用錐體射線電腦斷層攝影, 並利用ImplantMax 植牙軟體系統分析。結果顯示,利用金屬套筒導引式的手術模板輔助植牙手術產生誤差來源的最主要原因是來自手術模板的穩定性,意即手術模板於術前評估時在模型上的位置和手術當中手術模板固定的位置是影響準確性最大的因素,而本實驗使用手術模板輔助植牙手術的方法,所達到的準確度和文獻上其他植牙導引系統並無明顯的差異性,而利用本實驗模型方式來評估Simplant SurgiGuide 的準確性所得結果也和本實驗使用的手術模板所達到的準確性相似。 | zh_TW |
dc.description.abstract | Introduction: Dental implantation is a recently developed treatment since mid 1960s. By placing a titanium fixture into the jaw bone, a predicable union (osseointegration) between bone tissue and the implant could be achieved. There seems an increasing demand in dental implantation due to its excellent performance compared to conventional dental prostheses. However, the position of the implants has decisive effect on the final results in terms of mastication, phonation, and esthetics.
In order to achieve a predicable treatment outcome, a comprehensive diagnostic work-up of the planed implant positions and then precisely transferring to the implant surgery is a paramount before surgery. Image guided navigation surgery or stereographic surgical guide by CAD-CAM technique are developed for this purpose. There are many software and hardware designed by different companies available in the market nowadays. Their convenience and preciseness had been documented in many publications. However, the precision achieved was not tested by other authorities with a standardized method. The high cost of these surgical equipments or products also made them unpopular in routine planning or performing dental implant surgery. Materials and Methods: In this study, we used a simulated dental cast model to test the precision between the planned pre-operative implant position and the actual placed implant position using metal tube guided surgical templates. The radiographic examination and analysis of the implant position were performed with cone-beam CT (i-CAT) and ImplantMax software respectively. Results: The results shown that through high image resolution and precise reference markers, the positions of the implant could be predictably reported repeatedly. The pre-operative implant positions can be precisely transferred with metal tube guided surgical template. The major influencing factor in causing transfer error was the stability of the surgical guide used. That is to say, in performing dental implantation using techniques in this study, the main error was from the repeatability of the position of the surgical guide placed on the model during pre-operative planning and the position placed during surgery. The mean translation deviation were 0.3 and 0.4mm and mean angle deviation were 2.9 and 4.8 degrees in bilateral and unilateral tooth supported surgical guides respectively, which were similar to other systems reported. The mean translation and angle deviation were 0.45 mm and 3.54 degree with Simplant SurgiGuide using our study design. Conclusion: The preoperative planning of implant position could be predictably transferred to the operative field using metal tube guided surgical template. The main source of the error would be caused by the stability of the surgical guide. Using the techniques described in our study, the implant could be placed as accurately as other commercialized products like SimPlant SurgiGuide. | en |
dc.description.provenance | Made available in DSpace on 2021-06-12T18:31:09Z (GMT). No. of bitstreams: 1 ntu-96-P93422009-1.pdf: 3593542 bytes, checksum: 8ad10e352f9497684d978889903544bb (MD5) Previous issue date: 2007 | en |
dc.description.tableofcontents | 目 錄
圖表目錄 ........................................... 4 誌謝 ............................................... 7 中文摘要 ……………………………………………………… 8 英文摘要 ……………………………………………………… 9 一、緒論 ........................................... 12 第一部份:研究動機與背景 ……………………… 12 第二部份:文獻回顧 ……………………………… 13 第三部份:研究假說 ……………………………… 15 二、研究方法與材料 ………………………………………… 16 第一部份:使用機器與模型 ……………………… 16 第二部份: 影像拍攝 …………………………… 19 第三部份: 影像分析軟體 ………………………… 19 第四部份:資料統計分析 ………………………… 20 三、結果 ……………………………………………………… 21 第一部份:前導試驗 …………………………… 21 第二部份:模型試驗 …………………………… 21 第三部份:比較試驗 …………………………… 22 四、討論 …………………………………………………… 24 五、結論 …………………………………………………… 27 六、展望 …………………………………………………… 28 七、參考文獻 ……………………………………………… 29 圖目錄 圖一.drillMax 機器外觀 ………………………………………… 38 圖二.實驗使用模型設計 ………………………………………… 38 圖三.手術模板製作方式 ………………………………………… 39 圖四.金屬套筒導引式手術模板 (1)雙側牙齒支持式 (2)單側牙齒支持式…39 圖五.模擬手術的進行 ………………………………………………… 40 圖六.SimPlant SurgiGuide 實驗模型上進行模擬手術 ………………… 40 圖七.影像定位裝置 …………………………………………………… 41 圖八.i-CAT 牙科電腦斷層機器及模型拍攝擺置 ……………………… 41 圖九.電腦斷層影像資料經由ImplantMax 影像軟體分析後所得的畫面 … 42 圖十.經影像定位直接以drillMax鑽入缺牙區塊所得5組角度差異分佈 (參考座標為活動式影像定位裝置--活動式定位座標) ………… 42 圖十一.經影像定位直接以drillMax鑽入缺牙區塊所得5組位移差異分佈 (參考座標為活動式影像定位裝置--活動式定位座標) ………… 43 圖十二.經影像定位直接以drillMax鑽入缺牙區塊所得5組影像比較(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (活動式定位座標) ……………………………………………………………… 43 圖十三.經影像定位直接以drillMax鑽入缺牙區塊所得5組角度差異分佈 (參考座標為固定於主模型上的影像定位球) ………………… 44 圖十四.經影像定位直接以drillMax鑽入缺牙區塊所得5組位移差異分佈 (參考座標為固定於主模型上的影像定位球) ………………… 44 圖十五.經影像定位直接以drillMax鑽入缺牙區塊所得5組影像比較(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (固定式定位座標) ……………………………………………………………… 45 圖十六.使用雙側牙齒固位式手術模板導引模擬手術的角度偏差分佈圖 (活動式參考座標) ………………………………………… 45 圖十七.使用雙側牙齒固位式手術模板導引模擬手術的位移偏差分佈圖 (活動式參考座標) ………………………………………… 46 圖十八.使用雙側牙齒固位式手術模板導引模擬手術的5組影像資料(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (活動式定位座標) …………………………………………………………… 46 圖十九.使用單側牙齒固位式手術模板導引模擬手術的角度偏差分佈圖 (活動式參考座標) ……………………………………… 47 圖二十.使用單側牙齒固位式手術模板導引模擬手術的位移偏差分佈圖 (活動式參考座標) ……………………………………… 47 圖二十一.使用單側牙齒固位式手術模板導引模擬手術的5組影像資料(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (活動式定位座標) ………………………………………………………… 48 圖二十二.使用雙側牙齒固位式手術模板導引模擬手術的角度偏差分佈圖 (固定式參考座標) ……………………………………… 48 圖二十三. 使用雙側牙齒固位式手術模板導引模擬手術的位移偏差分佈圖 (固定式參考座標) ……………………………………… 49 圖二十四.使用雙側牙齒固位式手術模板導引模擬手術的5組影像資料(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (固定式定位座標) ………………………………………………………… 49 圖二十五.使用單側牙齒固位式手術模板導引模擬手術的角度偏差分佈圖 (固定式參考座標) ……………………………………… 50 圖二十六.使用單側牙齒固位式手術模板導引模擬手術的位移偏差分佈圖 (固定式參考座標) …………………………………… 50 圖二十七.使用單側牙齒固位式手術模板導引模擬手術的5組影像資料(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (固定式定位座標) …………………………………………………………… 51 圖二十八.使用SimPlant SurgiGuide手術模板導引模擬手術的角度偏差分佈圖 (活動式參考座標) ……………………………………… 51 圖二十九. 使用SimPlant SurgiGuide手術模板導引模擬手術的位移偏差分佈圖 (活動式參考座標) ……………………………………… 52 圖三十. 使用SimPlant SurgiGuide手術模板導引模擬手術的角度偏差分佈圖 (固定式參考座標) ……………………………………… 52 圖三十一.使用SimPlant SurgiGuide手術模板導引模擬手術的位移偏差分佈圖 (固定式參考座標) ……………………………………… 53 圖三十二.使用SimPlant SurgiGuide手術模板導引模擬手術的5組影像資料(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (活動式定位座標) ……………………………………………………… 53 圖三十三.使用SimPlant SurgiGuide手術模板導引模擬手術的5組影像資料(1)經ImplantMax 重組之3D影像 (2) 入口處之俯視圖 (固定式定位座標) ……………………………………………………… 54 表目錄 表一. 影像分析軟體針對同一影像重複分析的差異性(活動式定位座標)…54 表二. 影像分析軟體針對同一影像重複分析的差異性(固定式定位座標)…55 | |
dc.language.iso | zh-TW | |
dc.title | 電腦輔助設計製作手術模板應用於植牙手術的準確性 | zh_TW |
dc.title | The Precision of the Surgical Guide Used in Dental Implantation with CAD-CAM Technique | en |
dc.type | Thesis | |
dc.date.schoolyear | 95-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 蕭裕源(Yuh-Yuan Shiau),王兆麟(Jaw-Lin Wang) | |
dc.subject.keyword | 人工植牙,手術模板,錐體射線電腦斷層,電腦輔助植牙, | zh_TW |
dc.subject.keyword | accuracy,precision,dental implant,surgical guide,surgical template,cone-beam CT,computer aided implantation, | en |
dc.relation.page | 55 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2007-08-02 | |
dc.contributor.author-college | 醫學院 | zh_TW |
dc.contributor.author-dept | 臨床牙醫學研究所 | zh_TW |
顯示於系所單位: | 臨床牙醫學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-96-1.pdf 目前未授權公開取用 | 3.51 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。