Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
    • 指導教授
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 公共衛生學院
  3. 環境衛生研究所
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/26247
標題: 以固相微萃取技術結合微波輔助建立尿中三鹵甲烷與鹵乙酸之同步分析方法
Determination of Trihalomethanes and Halogenated Acetic Acids in Urine with Microwave-Assisted Solid-Phase Microextraction
作者: Ying-Hsun Chen
陳盈絢
指導教授: 蔡詩偉(Shih-Wei Tsai)
關鍵字: 三鹵甲烷,鹵乙酸,微波輔助,固相微萃取,尿液,
THMs,HAAs,microwave assisted,SPME,urine,
出版年 : 2009
學位: 碩士
摘要: Trihalomethanes(THMs) and haloacetic acids(HAAs) are well known disinfection-by products (DBPs). DBPs can be formed by the reaction between the residual chlorine and the humic acids in raw water. People expose to DBPs through various daily activities, including swimming, for example. Due to poor ventilation and continuing adding organic matter from the swimmers, the concentrations of DBPs in swimming pools are usually higher than what was found in tap water.
The concentrations of DBPs in water as well as in air can be determined through environmental assessment. However, there are variations with human activities, rate of absorption, distribution, metabolism, and excretion. Therefore, it is difficult to assess the actual exposure through environmental monitoring. On the other hand, biological monitoring can be applied to evaluate the amounts human body absorbed, while blood, urine and expired breath were common specimens for biomonitoring. Among them, urine sample is favored because the procedure for sample taking is invasive, easily operated with convenience.
Current analytical method utilized different techniques to determine THMs and HAAs in urine, respectively. The procedures were cumbersome and time consuming. Therefore, the purpose of this study was to develop a co-analyzed method for THMs and HAAs in urin. The analytical procedure involved derivatization and extraction of THMs and HAAs simultaneously in urine with microwave assisted headspace solid phase microextraction(MAE-HS-SPME). Gas chromatography with electron capture detector (GC/ECD) was used for the determination. Parameters that might affect the derivatization and the extraction efficiency were optimized. The Carboxen/Polydimethylsiloxane (CAR/PDMS) fiber appeared to be most suitable for the analysis of THMs and HAAs. Besides, the efficiencies of the derivatization and extraction were increased by adding the same volume of acidic methanol as the sample for the derivatization. The esterification/extraction temperature was set at 45°C for 40 min with low stirring rate and without salt addition. For the desosrption and analysis, GC/ECD was used and the temperature of the injection port was set at 250°C and the SPME fiber was desorbed for 2 min. The matrix effect was observed in this study, hence the standard addition method is recommended to be applied. The relative standard deviations (RSDs) for the analysis were between 3.333%-24.052% and 3.615%-15.914% for THMs and HAAs, respectively. The accuracies were between 100±2.53% ~ 100±18.97% and 100±1.19% ~ 100±16.66% for THMs and HAAs, respectively. The method detection limits ranged from 0.043 to 30.33 ng/mL.
The effects of decomposition from trihaloacetic acids on the determination of THMs were also investigated.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/26247
全文授權: 未授權
顯示於系所單位:環境衛生研究所

文件中的檔案:
檔案 大小格式 
ntu-98-1.pdf
  未授權公開取用
646.78 kBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved