Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
    • 指導教授
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 機械工程學系
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/88422
完整後設資料紀錄
DC 欄位值語言
dc.contributor.advisor蕭浩明zh_TW
dc.contributor.advisorHao-Ming Hsiaoen
dc.contributor.author王俊傑zh_TW
dc.contributor.authorJyun-Jie Wangen
dc.date.accessioned2023-08-15T16:13:52Z-
dc.date.available2023-11-09-
dc.date.copyright2023-08-15-
dc.date.issued2023-
dc.date.submitted2023-07-28-
dc.identifier.citationL. Floridi, "Metaverse: a matter of experience," Philosophy & Technology, vol. 35, no. 3, p. 73, 2022.
C. Lo, C. Chen, and R. Y. Zhong, "A review of digital twin in product design and development," Advanced Engineering Informatics, vol. 48, p. 101297, 2021.
"What is a Digital Twin," International Business Machines Corporation, 2022. [Online]. Available:https://www.ibm.com/topics/what-is-a-digital-twin, Accessed on Dec 8, 2022.
W. B. III, “Boeing CEO talks ‘Digital Twin’ era of aviation,” Avionics International, 2018. [Online]. Available: https://www.aviationtoday.com/2018/09/14/boeing-ceo-talks-digital-twin-era-aviation/, Accessed on Dec 8, 2022.
G. Bischof, A. Bischof, and H.-J. Rumpf, "Motivational interviewing: An evidence-based approach for use in medical practice," Deutsches Ärzteblatt International, vol. 118, no. 7, p. 109, 2021.
"Leading Causes of Death," Centers for Disease Control and Prevention, 2023. [Online]. Available:https://www.cdc.gov/nchs/fastats/leading-causes-of-death.htm, Accessed on Apr 13, 2023.
"110年國人死因統計結果," 中華民國衛生福利部, 2022. [Online]. Available:https://www.mohw.gov.tw/cp-16-70314-1.html, Accessed on Apr 13, 2023.
M.-Y. Wu, C.-J. Li, M.-F. Hou, and P.-Y. Chu, "New insights into the role of inflammation in the pathogenesis of atherosclerosis," International journal of molecular sciences, vol. 18, no. 10, p. 2034, 2017.
M. Batty, M. R. Bennett, and E. Yu, "The Role of Oxidative Stress in Atherosclerosis," Cells, vol. 11, no. 23, p. 3843, 2022.
D. L. Fischman, M. B. Leon, D. S. Baim, et al., "A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease," New England Journal of Medicine, vol. 331, no. 8, pp. 496-501, 1994.
"Angioplasty & Stenting in Patchogue, New Hyde Park & Hicksville," Brookhaven Heart, 2017. [Online]. Available:https://brookhavenheart.com/services/angioplasty-stenting/, Accessed on Apr 18, 2023.
J. B. Hermiller, A. Raizner, L. Cannon, et al., "Outcomes with the polymer-based paclitaxel-eluting TAXUS stent in patients with diabetes mellitus: the TAXUS-IV trial," Journal of the American College of Cardiology, vol. 45, no. 8, pp. 1172-1179, 2005.
J. E. Sousa, P. W. Serruys, and M. A. Costa, "New frontiers in cardiology: drug-eluting stents: Part I," Circulation, vol. 107, no. 17, pp. 2274-2279, 2003.
J. Bil, and R. J. Gil, "Bioresorbable vascular scaffolds—what does the future bring?," Journal of thoracic disease, vol. 8, no. 8, p. E741, 2016.
I. Skalidis, O. Muller, and S. Fournier, "CardioVerse: The cardiovascular medicine in the era of Metaverse," Trends in Cardiovascular Medicine, 2022.
陳永麒, "有限元素分析於心導管氣球及氣囊之應用," 碩士論文, 機械工程學研究所, 國立台灣大學, 臺北市, pp. 17-21, 2016.
謝沛廷, "血管分叉病變介入治療之有限元素分析," 碩士論文, 機械工程學研究所, 國立臺灣大學, 臺北市, 2021.
"Phantom Coronary Artery Models," National Institutes of Health, 2019. [Online]. Available:https://3d.nih.gov/entries/3dpx-012589, Accessed on Apr 20, 2023.
J. F. Lassen, N. R. Holm, A. Banning, et al., "Percutaneous coronary intervention for coronary bifurcation disease: 11th consensus document from the European Bifurcation Club," EuroIntervention, vol. 12, no. 1, pp. 38-46, 2016.
G. W. Stone, S. G. Ellis, D. A. Cox, et al., "One-year clinical results with the slow-release, polymer-based, paclitaxel-eluting TAXUS stent: the TAXUS-IV trial," Circulation, vol. 109, no. 16, pp. 1942-1947, 2004.
D. R. Holmes, M. B. Leon, J. W. Moses, et al., "Analysis of 1-Year Clinical Outcomes in the SIRIUS Trial," Circulation, vol. 109, no. 5, pp. 634-640, 2004.
E. Schampaert, J. W. Moses, J. Schofer, et al., "Sirolimus-eluting stents at two years: a pooled analysis of SIRIUS, E-SIRIUS, and C-SIRIUS with emphasis on late revascularizations and stent thromboses," The American journal of cardiology, vol. 98, no. 1, pp. 36-41, 2006.
K. Grodecki, M. P. Opolski, A. D. Staruch, et al., "Comparison of computed tomography angiography versus invasive angiography to assess medina classification in coronary bifurcations," The American Journal of Cardiology, vol. 125, no. 10, pp. 1479-1485, 2020.
A. Medina, J. S. de Lezo, and M. Pan, "A new classification of coronary bifurcation lesions," Revista espanola de cardiologia, vol. 59, no. 2, p. 183, 2006.
Y. Louvard, M. Thomas, V. Dzavik, et al., "Classification of coronary artery bifurcation lesions and treatments: Time for a consensus!," Catheterization and Cardiovascular Interventions, vol. 71, no. 2, pp. 175-183, 2008.
V. Legrand, M. Thomas, M. Zelisko, et al., "Percutaneous coronary intervention of bifurcation lesions: state-of-the-art. Insights from the second meeting of the European Bifurcation Club," EuroIntervention: journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, vol. 3, no. 1, 2007.
J. F. Lassen, N. R. Holm, G. Stankovic, et al., "Percutaneous coronary intervention for coronary bifurcation disease: consensus from the first 10 years of the European Bifurcation Club meetings," EuroIntervention, vol. 10, no. 5, pp. 545-560, 2014.
F. Burzotta, J. F. Lassen, Y. Louvard, et al., "European Bifurcation Club white paper on stenting techniques for patients with bifurcated coronary artery lesions," Catheterization and Cardiovascular Interventions, vol. 96, no. 5, pp. 1067-1079, 2020.
E. Alegria-Barrero, N. Foin, A. Lindsay, et al., "How to optimize the percutaneous treatment of bifurcated lesions: Dedicated stents vs. provisional stenting," Minerva Cardioangiol, vol. 5, pp. 575-590, 2013.
M. Pan, A. Medina, M. Romero, et al., "Assessment of side branch predilation before a provisional T-stent strategy for bifurcation lesions. A randomized trial," American Heart Journal, vol. 168, no. 3, pp. 374-380, 2014.
P. Zamani, and S. Kinlay, "Long‐term risk of clinical events from stenting side branches of coronary bifurcation lesions with drug‐eluting and bare‐metal stents: An observational meta‐analysis," Catheterization and Cardiovascular Interventions, vol. 77, no. 2, pp. 202-212, 2011.
S.-J. Kang, G. S. Mintz, W.-J. Kim, et al., "Changes in left main bifurcation geometry after a single-stent crossover technique: an intravascular ultrasound study using direct imaging of both the left anterior descending and the left circumflex coronary arteries before and after intervention," Circulation: Cardiovascular Interventions, vol. 4, no. 4, pp. 355-361, 2011.
S. J. Kang, W. J. Kim, J. Y. Lee, et al., "Hemodynamic impact of changes in bifurcation geometry after single‐stent cross‐over technique assessed by intravascular ultrasound and fractional flow reserve," Catheterization and Cardiovascular Interventions, vol. 82, no. 7, pp. 1075-1082, 2013.
S. K. Sharma, "Simultaneous kissing drug‐eluting stent technique for percutaneous treatment of bifurcation lesions in large‐size vessels," Catheterization and cardiovascular interventions, vol. 65, no. 1, pp. 10-16, 2005.
S. K. Sharma, A. Choudhury, J. Lee, et al., "Simultaneous kissing stents (SKS) technique for treating bifurcation lesions in medium-to-large size coronary arteries," The American journal of cardiology, vol. 94, no. 7, pp. 913-917, 2004.
C. T. Stinis, S. P. Hu, M. J. Price, and P. S. Teirstein, "Three‐year outcome of drug‐eluting stent implantation for coronary artery bifurcation lesions," Catheterization and Cardiovascular Interventions, vol. 75, no. 3, pp. 309-314, 2010.
P. D. Morris, J. Iqbal, C. Chiastra, et al., "Simultaneous kissing stents to treat unprotected left main stem coronary artery bifurcation disease; stent expansion, vessel injury, hemodynamics, tissue healing, restenosis, and repeat revascularization," Catheterization and Cardiovascular Interventions, vol. 92, no. 6, pp. E381-E392, 2018.
I. Iakovou, L. Ge, and A. Colombo, "Contemporary stent treatment of coronary bifurcations," Journal of the American College of Cardiology, vol. 46, no. 8, pp. 1446-1455, 2005.
A. Colombo, G. Stankovic, D. Orlic, et al., "Modified T‐stenting technique with crushing for bifurcation lesions: immediate results and 30‐day outcome," Catheterization and cardiovascular interventions, vol. 60, no. 2, pp. 145-151, 2003.
G. Sianos, S. Vaina, A. Hoye, and P. W. Serruys, "Bifurcation stenting with drug eluting stents: Illustration of the crush technique," Catheterization and cardiovascular interventions, vol. 67, no. 6, pp. 839-845, 2006.
A. R. Galassi, A. Colombo, M. Buchbinder, et al., "Long‐term outcomes of bifurcation lesions after implantation of drug‐eluting stents with the “mini‐crush technique”," Catheterization and Cardiovascular Interventions, vol. 69, no. 7, pp. 976-983, 2007.
J. A. Ormiston, E. Currie, M. W. Webster, et al., "Drug‐eluting stents for coronary bifurcations: insights into the crush technique," Catheterization and cardiovascular interventions, vol. 63, no. 3, pp. 332-336, 2004.
L. Räber, P. Jüni, L. Löffel, et al., "Impact of stent overlap on angiographic and long-term clinical outcome in patients undergoing drug-eluting stent implantation," Journal of the American College of Cardiology, vol. 55, no. 12, pp. 1178-1188, 2010.
K. WANG, X. R. ZHOU, E. Verbeken, et al., "Overlapping coronary stents result in an increased neointimal hyperplasia: insight from a porcine coronary stent model," Journal of Interventional Cardiology, vol. 13, no. 3, pp. 173-177, 2000.
J. Xu, J. Yang, S. Sohrabi, et al., "Finite element analysis of the implantation process of overlapping stents," Journal of medical devices, vol. 11, no. 2, 2017.
H. Zahedmanesh, and C. Lally, "Determination of the influence of stent strut thickness using the finite element method: implications for vascular injury and in-stent restenosis," Medical & biological engineering & computing, vol. 47, pp. 385-393, 2009.
A. Schiavone, C. Abunassar, S. Hossainy, and L. Zhao, "Computational analysis of mechanical stress–strain interaction of a bioresorbable scaffold with blood vessel," Journal of biomechanics, vol. 49, no. 13, pp. 2677-2683, 2016.
C. Conway, J. McGarry, E. Edelman, and P. McHugh, "Numerical simulation of stent angioplasty with predilation: an investigation into lesion constitutive representation and calcification influence," Annals of biomedical engineering, vol. 45, pp. 2244-2252, 2017.
T. Qiu, R. He, C. Abunassar, et al., "Effect of two-year degradation on mechanical interaction between a bioresorbable scaffold and blood vessel," Journal of the Mechanical Behavior of Biomedical Materials, vol. 78, pp. 254-265, 2018.
R. He, L. Zhao, V. Silberschmidt, et al., "Finite element evaluation of artery damage in deployment of polymeric stent with pre-and post-dilation," Biomechanics and modeling in mechanobiology, vol. 19, pp. 47-60, 2020.
R. He, L. Zhao, V. V. Silberschmidt, and Y. Liu, "Mechanistic evaluation of long-term in-stent restenosis based on models of tissue damage and growth," Biomechanics and Modeling in Mechanobiology, vol. 19, pp. 1425-1446, 2020.
S. Y. Lim, M. H. Jeong, S. J. Hong, et al., "Inflammation and delayed endothelization with overlapping drug-eluting stents in a porcine model of in-stent restenosis," Circulation Journal, vol. 72, no. 3, pp. 463-468, 2008.
R. He, L. Zhao, V. Silberschmidt, et al., "Patient-specific modelling of stent overlap: Lumen gain, tissue damage and in-stent restenosis," journal of the mechanical behavior of biomedical materials, vol. 109, p. 103836, 2020.
Y. S. Chatzizisis, A. U. Coskun, M. Jonas, et al., "Role of endothelial shear stress in the natural history of coronary atherosclerosis and vascular remodeling: molecular, cellular, and vascular behavior," Journal of the American College of Cardiology, vol. 49, no. 25, pp. 2379-2393, 2007.
C. Cheng, D. Tempel, R. Van Haperen, et al., "Atherosclerotic lesion size and vulnerability are determined by patterns of fluid shear stress," Circulation, vol. 113, no. 23, pp. 2744-2753, 2006.
M. I. Papafaklis, C. V. Bourantas, P. E. Theodorakis, et al., "The effect of shear stress on neointimal response following sirolimus-and paclitaxel-eluting stent implantation compared with bare-metal stents in humans," JACC: Cardiovascular Interventions, vol. 3, no. 11, pp. 1181-1189, 2010.
J. J. Wentzel, F. J. Gijsen, J. C. Schuurbiers, et al., "The influence of shear stress on in-stent restenosis and thrombosis," EuroIntervention, vol. 4, 2008.
D. Matsumoto, J. Shite, T. Shinke, et al., "Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography," European heart journal, vol. 28, no. 8, pp. 961-967, 2007.
F. Rikhtegar, C. Wyss, K. S. Stok, et al., "Hemodynamics in coronary arteries with overlapping stents," Journal of biomechanics, vol. 47, no. 2, pp. 505-511, 2014.
S. G. Ellis, M. Savage, D. Fischman, et al., "Restenosis after placement of Palmaz-Schatz stents in native coronary arteries. Initial results of a multicenter experience," Circulation, vol. 86, no. 6, pp. 1836-1844, 1992.
D. J. Kereiakes, H. Wang, J. J. Popma, et al., "Periprocedural and late consequences of overlapping Cypher sirolimus-eluting stents: pooled analysis of five clinical trials," Journal of the American College of Cardiology, vol. 48, no. 1, pp. 21-31, 2006.
F. Alfonso, M.-J. Pérez-Vizcayno, M. Ruiz, et al., "Coronary aneurysms after drug-eluting stent implantation: clinical, angiographic, and intravascular ultrasound findings," Journal of the American College of Cardiology, vol. 53, no. 22, pp. 2053-2060, 2009.
A. V. Finn, F. D. Kolodgie, J. Harnek, et al., "Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus-or paclitaxel-eluting stents," Circulation, vol. 112, no. 2, pp. 270-278, 2005.
F. Fogarotto, "Finite element analysis of coronary artery stenting," M.S. thesis, Biomedical Engineering, Pavia Univ., Pavia PV, Italy, 2011.
G. Mouktadiri, and B. Bou-Sa, "Aortic endovascular repair modeling using the finite element method," Journal of biomedical science and engineering, vol. 2013, 2013.
"SPRINTER LEGEND RX SEMICOMPLIANT BALLOON DILATATION CATHETER," Medtronic, 2016. [Online]. Available:http://www.medtronic.com/for-healthcare-professionals/products-therapies/cardiov ascular/catheters/balloon-dilatation-catheters/sprinter-legend-rx-semicompliant-balloon-dilatation-catheter/#tab2, Accessed on Apr 13, 2023.
M. De Beule, "Finite element stent design," Ph.D. dissertation, Biomedical Engineering Techniques, Ghent Univ., Ghent, Belgium, pp.49-54, 2008.
S. Timoshenko,"", Strength of Materials.-1: Elementary Theory and Problems: Van Nostrand, 1955.
蘇冠傑, "應用機器視覺於藥物載具自動塗佈系統之設計與實現," 碩士論文, 機械工程學研究所, 國立台灣大學, 臺北市, p. 59, 2017.
"XIENCE SIERRA PRODUCT DETAILS," Abbott, 2019. [Online]. Available:https://www.xiencestent.com/us/stent-design/?L=0, Accessed on May 22, 2023.
"薬剤溶出型冠動脈ステント Orsiro," Japan Lifeline, 2019. [Online]. Available:https://www.jll.co.jp/medical/coronary_stent.html, Accessed on May 22, 2023.
M. A. Z. Valencia, "Methods for automation of vascular lesions detection in computed tomography images," M.S. thesis, Human Health and Pathology, Université Claude Bernard-Lyon I; Universidad de los Andes, p.2, 2011.
A. Gupta, S. Sett, S. Varahoor, and B. Wolf, "Investigation of interaction between guidewire and native vessel using finite element analysis," Proceedings of the 2010 Simulia Customer Conference, 2010.
G. A. Holzapfel, G. Sommer, C. T. Gasser, and P. Regitnig, "Determination of layer-specific mechanical properties of human coronary arteries with nonatherosclerotic intimal thickening and related constitutive modeling," American Journal of Physiology-Heart and Circulatory Physiology, vol. 289, no. 5, pp. H2048-H2058, 2005.
D. A. Vorp, "Biomechanics of abdominal aortic aneurysm," Journal of biomechanics, vol. 40, no. 9, pp. 1887-1902, 2007.
D. M. Ebenstein, D. Coughlin, J. Chapman, et al., "Nanomechanical properties of calcification, fibrous tissue, and hematoma from atherosclerotic plaques," Journal of Biomedical Materials Research Part A: An Official Journal of The Society for Biomaterials, The Japanese Society for Biomaterials, and The Australian Society for Biomaterials and the Korean Society for Biomaterials, vol. 91, no. 4, pp. 1028-1037, 2009.
J. Ohayon, G. Finet, F. Treyve, et al., "A three-dimensional finite element analysis of stress distribution in a coronary atherosclerotic plaque: in-vivo prediction of plaque rupture location," Biomechanics applied to computer assisted surgery, vol. 37, no. 2, pp. 225-241, 2005.
A. Versluis, A. J. Bank, and W. H. Douglas, "Fatigue and plaque rupture in myocardial infarction," Journal of biomechanics, vol. 39, no. 2, pp. 339-347, 2006.
M. Cilla, E. Peña, and M. Martínez, "3D computational parametric analysis of eccentric atheroma plaque: influence of axial and circumferential residual stresses," Biomechanics and modeling in mechanobiology, vol. 11, pp. 1001-1013, 2012.
-
dc.identifier.urihttp://tdr.lib.ntu.edu.tw/jspui/handle/123456789/88422-
dc.description.abstract心血管疾病長年霸榜全球人口死亡主因,通常會透過經皮冠狀動脈介入治療進行緊急處置。分叉病變的治療以及血管支架重疊技術的使用作為常見的多支架治療手法,雖然在所有經皮冠狀動脈介入治療案件中佔有一定比例,然而受限於技術本身存在的缺陷,術後患者發生血管再狹窄或急性狀況的比例也因此高於僅用單一支架進行治療的病患。目前為了幫助評估病患於術後的治療狀況,學界開發了多項有限元素模擬模型幫助分析,然而多數在血管零件上過於理想化,也因此降低了整體結果的參考價值。目前在實務上,對於評估病人術後的恢復狀況,大多僅能依靠醫師經驗以及長期追蹤的研究報告。
本研究使用美國國家衛生研究院提供的公開病人冠狀動脈檔案,進行經皮冠狀動脈介入治療的真實血管模型構建,研究由兩部分組成,分別為分叉病變治療及血管支架重疊技術:在分叉病變模型中,使用兩種不同的商用支架結合兩種不同的治療手法(Simultaneous Kissing Stenting & Crush Technique),藉此評估模型實施治療技術的能力;而在血管支架重疊技術中,使用幾何定義完善的VYW血管支架,探討單一長支架部屬、雙支架不重疊、雙支架微重疊、雙支架全重疊等四種不同的重疊情況,同時評估模型的極限耐受強度。整個模擬過程透過VDISP子程序大幅降低血管支架定位至病灶處的時間,並以準靜態分析血管支架、氣球導管以及病變血管之間複雜的交互作用問題,所有模擬在最後皆完整地完成分析,且在分析效率上與過往研究相比有一倍以上的提升。在模型結果上,本研究對血管零件設定普通血管及硬化斑塊兩種材料進行對比測試,透過比較不同的血管支架廠牌及治療手法,並評估術後的血管支架塑性應變、整體幾何結構、血管最大應力和管腔增幅,為每種不同的治療方案提供數據及圖像化的參考依據,同時分析其優與劣,找出現有方案中的最佳治療方法,提升整體醫療成效。
zh_TW
dc.description.abstractCardiovascular diseases continue to be a leading cause of death worldwide, often requiring emergency percutaneous coronary interventions (PCI) for treatment. Among these procedures, the treatment of bifurcation lesions and the use of stent overlapping techniques in multi-stenting procedures have become common approaches but pose significant challenges. Patients undergoing such procedures have a higher incidence of in-stent restenosis or acute outcomes compared to those treated with a single stent, primarily due to inherent limitations in these techniques. While several finite element simulation models have been developed in academia to aid evaluation, most of them idealize the artery components, reducing the overall reliability of the results. Currently, the assessment of patients' postoperative recovery heavily relies on physician experience and long-term follow-up studies.
This study utilized publicly available patient coronary artery datasets provided by the National Institutes of Health to construct realistic patient-specific models for PCI. The research consisted of two parts: treatment of bifurcation lesions and stent overlapping techniques. In the bifurcation lesions models, two different commercial stents were combined with two treatment techniques (Simultaneous Kissing Stenting & Crush Technique) to evaluate the feasibility of implementing these treatment strategies. For the stent overlapping techniques, a well-defined VYW stent was used to investigate four overlapping scenarios: single long stent deployment, non-overlapping double stents, minimally overlapping double stents, and fully overlapping double stents. Additionally, the robustness of the model was tested in this part to assess its ability to withstand extreme conditions. The VDISP subroutine was employed to significantly reduce the time required for stent positioning at the lesion site, and quasi-static analysis was conducted to examine the complex interactions between the stents, balloon catheters, and diseased arteries. All simulations were successfully completed, with analysis efficiency improved by more than twofold compared to previous studies.
In terms of the model results, this study conducted comparative tests on two materials: normal artery components and hardened plaques. By comparing different stent brands and treatment techniques, the study evaluated postoperative stent plastic strain, overall geometric structure, maximum vessel stress, and lumen gain. It provided quantitative data and visual references as a basis for each treatment strategy, enabling analysis of their strengths and weaknesses. Through this comprehensive assessment, the study aimed to identify the optimal treatment method among the existing options and enhance overall medical effectiveness.
en
dc.description.provenanceSubmitted by admin ntu (admin@lib.ntu.edu.tw) on 2023-08-15T16:13:52Z
No. of bitstreams: 0
en
dc.description.provenanceMade available in DSpace on 2023-08-15T16:13:52Z (GMT). No. of bitstreams: 0en
dc.description.tableofcontents口試委員會審定書 i
誌謝 ii
摘要 iii
Abstract iv
目錄 vi
圖目錄 ix
表目錄 xiv
第一章 緒論 1
1.1. 前言 1
1.2. 心血管疾病 3
1.2.1. 動脈粥狀硬化 3
1.2.2. 心宇宙 5
1.3. 研究動機與目的 6
1.4. 研究內容 7
第二章 文獻探討 9
2.1. 分叉病變 9
2.1.1. 分叉病變介入治療(Bifurcation Intervention) 10
2.2. 支架重疊技術 16
2.2.1. 有限元素模擬 16
2.2.2. 計算流體力學 18
2.2.3. 臨床表現 20
第三章 真實冠狀動脈分叉病變有限元素模型 22
3.1. 有限元素模型建立 22
3.1.1. 導管模型 22
3.1.2. 氣球模型 24
3.1.3. 氣球擴張式血管支架 29
3.1.4. 真實冠狀動脈與分叉病變 36
3.1.5. 剛性套筒 43
3.1.6. 小結 51
3.2. 有限元素模型設定 51
3.2.1. 接觸設定與邊界條件 52
3.2.2. 模擬步驟 53
3.2.3. 粘滯壓力(Viscous Pressure) 56
3.3. 有限元素模擬結果與討論 57
3.3.1. 模型部屬結果 58
3.3.2. 綜合討論 66
3.4. 小結 72
第四章 真實冠狀動脈之支架重疊技術有限元素模型 74
4.1. 簡介 74
4.2. 有限元素模型建立 74
4.2.1. 氣球擴張式血管支架 74
4.2.2. 真實冠狀動脈 76
4.2.3. 剛性套筒 76
4.3. 有限元素模型設定 77
4.4. 有限元素模擬結果與討論 81
4.4.1. 模型部屬結果 81
4.4.2. 材料差異和血壓膨脹效應 87
4.4.3. 綜合討論 89
4.4.4. 小結 96
第五章 結論與未來展望 97
參考文獻 100
-
dc.language.isozh_TW-
dc.subject血管支架重疊zh_TW
dc.subject有限元素法zh_TW
dc.subject病患生理解剖建模zh_TW
dc.subject經皮冠狀動脈介入治療zh_TW
dc.subject分叉病變zh_TW
dc.subjectStent overlappingen
dc.subjectPatient-specific modellingen
dc.subjectPercutaneous coronary interventionen
dc.subjectBifurcation lesionsen
dc.subjectFinite element analysisen
dc.title基於個別病患生理解剖之心導管手術有限元素模擬zh_TW
dc.titleFinite Element Modelling for Patient-Specific Anatomy in Percutaneous Coronary Interventionen
dc.typeThesis-
dc.date.schoolyear111-2-
dc.description.degree碩士-
dc.contributor.oralexamcommittee林峻永;顏炳郎zh_TW
dc.contributor.oralexamcommitteeChun-Yeon Lin;Ping-Lang Yenen
dc.subject.keyword有限元素法,病患生理解剖建模,經皮冠狀動脈介入治療,分叉病變,血管支架重疊,zh_TW
dc.subject.keywordFinite element analysis,Patient-specific modelling,Percutaneous coronary intervention,Bifurcation lesions,Stent overlapping,en
dc.relation.page109-
dc.identifier.doi10.6342/NTU202302303-
dc.rights.note同意授權(全球公開)-
dc.date.accepted2023-08-01-
dc.contributor.author-college工學院-
dc.contributor.author-dept機械工程學系-
顯示於系所單位:機械工程學系

文件中的檔案:
檔案 大小格式 
ntu-111-2.pdf5.6 MBAdobe PDF檢視/開啟
顯示文件簡單紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved