| 摘要: | 基於雙平面動態X光影像進行比對得到運動學資訊,並結合核磁共振掃描所得之三維軟骨模型求得膝關節面運動學,在目前為活體非侵入性方法中較精確且常見的,而在量測膝關節面運動學中,重建個人化三維軟骨模型是最為重要的,然而目前最精確的方法是透過核磁共振掃描影像進行重建,其會有花費過高、時間因素以及核磁共振骨頭模型精度不佳等問題,並且在後續分析上也會遇到兩種不同來源的模型因影像解析度等因素使得外形有誤差。因此後來便有許多研究致力於發展僅透過電腦斷層掃瞄資訊即可計算關節面接觸運動學的方法,過去本實驗室有提出的平均厚度虛擬軟骨方法,然而其誤差普遍偏高,能否能達到膝關節面運動學之精度需求是很值得探討的。因此本研究之目的即為提出一個基於統計形狀模型的方法,能夠透過電腦斷層掃描之膝關節骨模型等資訊,計算其膝關節面運動學資訊。
本研究以三十五隻膝關節軟骨模型建立膝關節軟骨形狀統計模型,並開發搭配受試者進行彎曲伸直時的運動學資訊,重建出用以計算膝關節運動學之個人化膝關節軟骨模型,並透過活體實驗,以驗證此方法之可行性,並量化三維軟骨模型重建誤差以及其應用於膝關節面運動學計算結果誤差。 本研究的結果顯示,用於計算膝關節面運動學的模型重建上,在內側膝關節所得之接觸點誤差依前後方向、近遠端方向和內外側方向分別為1.33±0.71mm、1.23±0.50mm以及2.64±1.48mm,在外側膝關節所得之接觸點誤差分別為0.77±0.37mm、1.01±0.87mm以及2.26±1.48mm。本研究所開發之方法相較於以前之均勻厚度虛擬軟骨計算法要來的精準,具有足夠應用於膝關節面運動學的計算。 Measuring knee joint arthrokinematics by using bi-plane fluoroscopic image and magnetic resonance imaging cartilage model is a common and accurate in-vivo non-invasive method. The most important part of this method is the subject-specific cartilage model reconstruction. Currently, the most accurate cartilage models are reconstructed by the magnetic resonance images (MRI). However, MRI may cause some concerns such as expensive, and the poor accuracy of the MRI bone model. Therefore, many studies have been devoted to the development of methods for calculating arthrokinematics by only CT bone information. Our lab has proposed the average thickness virtual cartilage method of measuring knee joint arthrokinematics, but its error is generally high. Therefore, the purpose of this study is to propose a method based on statistical shape model, which can calculate the arthrokinematics of knee joint only through information such as knee joint kinematic and the CT bone model. The study collects 35 models of cartilages of knee joint to establish the knee joint statistical shape model (SSM), and develop a method for reconstruction of subject-specific cartilages of knee joint (SSM-K) to measuring knee joint arthrokinematics while cycling via flexion-extension kinematic and the CT bone model. The in-vivo experiments were performed to verify the feasibility of this method, and to quantify the reconstruction error of the three-dimensional cartilage model and its arthrokinematics calculation error. The result showed the contact point error calculated on the medial side of the knee joint was 1.33±0.71mm on the anterior-posterior direction (AP), 1.23±0.50mm on the proximal-distal direction (DP), and 2.64±1.48mm on the medial-lateral direction (ML). On the other hand, the contact point error calculated on the lateral side of the knee joint was 0.77±0.37mm on the anterior-posterior direction (AP), 1.01±0.87mm on the proximal -distal direction (DP), and 1.01±0.87mm on the medial-lateral direction (ML). This indicated that the method developed in this study is more accurate than the previous uniform thickness virtual cartilage method, and has sufficient calculation for knee joint surface kinematics. |
| URI: | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/78626 |
| DOI: | 10.6342/NTU201903318 |
| 全文授權: | 未授權 |
| 電子全文公開日期: | 2029-12-31 |
| 顯示於系所單位: | 醫學工程學研究所 |
文件中的檔案:
| 檔案 | 大小 | 格式 | |
|---|---|---|---|
| ntu-107-2.pdf 未授權公開取用 | 3.58 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。