請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/70714
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 李百祺 | |
dc.contributor.author | Pei-Yu Chao | en |
dc.contributor.author | 趙珮妤 | zh_TW |
dc.date.accessioned | 2021-06-17T04:35:52Z | - |
dc.date.available | 2021-08-18 | |
dc.date.copyright | 2018-08-18 | |
dc.date.issued | 2018 | |
dc.date.submitted | 2018-08-09 | |
dc.identifier.citation | [1] J. F. Greenleaf, M. Fatemi, and M. Insana, 'Selected methods for imaging elastic properties of biological tissues,' Annu. Rev. Biomed. Eng., vol. 5, pp. 57-78, 2003.
[2] J. Ophir, S. K. Alam, B. S. Garra, F. Kallel, E. E. Konofagou, T. Krouskop, et al., 'Elastography: Imaging the elastic properties of soft tissues with ultrasound,' J. Med. Ultrasonics, vol. 29, pp. 155–171, 2002. [3] K. Nightingale, R. Bentley, and G. Trahey, 'Observations of Tissue Response to Acoustic Radiation Force: Opportunities for Imaging,' Ultrason. Imaging, vol. 24, pp. 129–138, 2002. [4] A. P. Sarvazyan, O. V. Rudenko, S. D. Swanson, J. B. Fowlkes, and S. Y. Emelianov, 'Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics,' Ultrasound Med. Biol., vol. 24, pp. 1419–1435, 1998. [5] K. Nightingale, S. McAleavey, and G. Trahey, 'Shear-wave generation using acoustic radiation force: in vivo and ex vivo results,' Ultrasound Med. Biol., vol. 29, pp. 1715–1723, 2003. [6] L. Sandrin, M. Tanter, S. Catheline, and M. Fink, 'Shear modulus imaging with 2-D transient elastography,' IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 49, pp. 426–435, 2002. [7] J.-L. Gennisson, T. Deffieux, M. Fink, and M. Tanter, 'Ultrasound elastography: principles and techniques,' Diagn. Interv. Imaging, vol. 94, pp. 487-495, 2013. [8] M. M. Doyley and K. J. Parker, 'Elastography: General Principles and Clinical Applications,' Ultrasound Clin., vol. 9, pp. 1-11, 2014. [9] J. Bercoff, M. Tanter, and M. Fink, 'Supersonic shear imaging: a new technique for soft tissue elasticity mapping,' IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 51, pp. 396-409, 2004. [10] T. Deffieux, J.-L. Gennisson, B. Larrat, M. Fink, and M. Tanter, 'The variance of quantitative estimates in shear wave imaging: theory and experiments,' IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 59, pp. 2390–2410, 2012. [11] H. Zhao, P. Song, M. W. Urban, J. F. Greenleaf, and S. Chen, 'Robust shear wave speed measurement using comb-push ultrasound radiation force,' in IEEE International Ultrasonics Symposium, Florida, USA, 2011, pp. 1270-1273. [12] J. M. Schmitt, 'OCT elastography: imaging microscopic deformation and strain of tissue,' Opt. Express, vol. 3, pp. 199-211, 1998. [13] M. Razani, T. W. H. Luk, A. Mariampillai, P. Siegler, T.-R. Kiehl, M. C. Kolios, et al., 'Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samples,' Biomed. Opt. Express, vol. 5, pp. 895–906, 2014. [14] S. Wang and K. V. Larin, 'Shear wave imaging optical coherence tomography (SWI-OCT) for ocular tissue biomechanics,' Opt. Lett., vol. 39, pp. 41-44, 2014. [15] K. V. Larin and D. D. Sampson, 'Optical coherence elastography - OCT at work in tissue biomechanics [Invited],' Biomed. Opt. Express, vol. 8, pp. 1172-1202, 2017. [16] A. Nahas, M. Tanter, T.-M. Nguyen, J.-M. Chassot, M. Fink, and A. C. Boccara, 'From supersonic shear wave imaging to full-field optical coherence shear wave elastography,' J. Biomed. Opt., vol. 18, p. 121514, 2013. [17] T.-M. Nguyen, S. Song, B. Arnal, Z. Huang, M. O’Donnell, and R. K. Wang, 'Visualizing ultrasonically-induced shear wave propagation using phase-sensitive optical coherence tomography for dynamic elastography,' Opt. Lett., vol. 39, pp. 838-841, 2014. [18] E. Bossy, A. R. Funke, K. Daoudi, and A.-C. Boccara, 'Transient optoelastography in optically diffusive media,' Appl. Phys. Lett., vol. 90, p. 174111, 2007. [19] D. A. Boas and A. K. Dunn, 'Laser speckle contrast imaging in biomedical optics,' J. Biomed. Opt., vol. 15, p. 011109, 2010. [20] Y. Cheng, R. Li, S. Li, C. Dunsby, R. J. Eckersley, D. S. Elson, et al., 'Shear wave elasticity imaging based on acoustic radiation force and optical detection,' Ultrasound Med. Biol., vol. 38, pp. 1637–1645, 2012. [21] R. Edmondson, J. J. Broglie, A. F. Adcock, and L. Yang, 'Three-dimensional cell culture systems and their applications in drug discovery and cell-based biosensors,' Assay Drug Dev. Technol., vol. 12, pp. 207–218, 2014. [22] D. Antoni, H. Burckel, E. Josset, and G. Noel, 'Three-dimensional cell culture: a breakthrough in vivo,' Int. J. Mol. Sci., vol. 16, pp. 5517–5527, 2015. [23] F. Pampaloni, E. G. Reynaud, and E. H. K. Stelzer, 'The third dimension bridges the gap between cell culture and live tissue,' Nat. Rev. Mol. Cell Biol., vol. 8, pp. 839–845, 2007. [24] M. Ravi, V. Paramesh, S. R. Kaviya, E. Anuradha, and F. D. P. Solomon, '3D cell culture systems: advantages and applications,' J. Cell Physiol., vol. 230, pp. 16-26, 2015. [25] B. N. Mason, J. P. Califano, and C. A. Reinhart-King, 'Matrix stiffness: A regulator of cellular behavior and tissue formation,' in Engineering Biomaterials for Regenerative Medicine, S. K. Bhatia, Ed., ed New York: Springer, 2012, pp. 19-37. [26] J. P. Winer, A. Chopra, J. Y. Kresh, and P. A. Janmey, 'Substrate elasticity as a probe to measure mechanosensing at cell-cell and cell-matrix Junctions,' in Mechanobiology of Cell-Cell and Cell-Matrix Interactions, A. W. Johnson and B. A. C. Harley, Eds., ed Boston: Springer, 2011. [27] T. R. Cox and J. T. Erler, 'Remodeling and homeostasis of the extracellular matrix: implications for fibrotic diseases and cancer,' Dis. Model Mech., vol. 4, pp. 165–178, 2011. [28] P. Lu, V. M. Weaver, and Z. Werb, 'The extracellular matrix: A dynamic niche in cancer progression,' J. Cell Biol., vol. 196, pp. 395–406, 2012. [29] D. T. Butcher, T. Alliston, and V. M. Weaver, 'A tense situation: forcing tumour progression,' Nat. Rev. Cancer, vol. 9, pp. 108–122, 2009. [30] A. M. Handorf, Y. Zhou, M. A. Halanski, and W.-J. Li, 'Tissue stiffness dictates development, homeostasis, and disease progression,' Organogenesis, vol. 11, pp. 1–15, 2015. [31] J. L. Vanderhooft, M. Alcoutlabi, J. J. Magda, and G. D. Prestwich, 'Rheological properties of cross-linked hyaluronan-gelatin hydrogels for tissue engineering,' Macromol. Biosci., vol. 9, pp. 20–28, 2009. [32] O. Chaudhuri, L. Gu, D. Klumpers, M. Darnell, S. A. Bencherif, J. C. Weaver, et al., 'Hydrogels with tunable stress relaxation regulate stem cell fate and activity,' Nat. Mater., vol. 15, pp. 326–334, 2016. [33] D. Wirtz, 'Particle-tracking microrheology of living cells: principles and applications,' Annu. Rev. Biophys., vol. 38, pp. 301–326, 2009. [34] Y. Tseng, T. P. Kole, and D. Wirtz, 'Micromechanical mapping of live cells by multiple-particle-tracking microrheology,' Biophys. J., vol. 83, pp. 3162–3176, 2002. [35] G. Thomas, N. A. Burnham, T. A. Camesano, and Q. Wen, 'Measuring the mechanical properties of living cells using atomic force microscopy,' J. Vis. Exp., vol. 76, p. 50497, 2013. [36] S. S. Soofi, J. A. Last, S. J. Liliensiek, P. F. Nealey, and C. J. Murphy, 'The elastic modulus of Matrigel as determined by atomic force microscopy,' J. Struct. Biol., vol. 167, pp. 216–219, 2009. [37] N. Gavara and R. S. Chadwick, 'Relationship between cell stiffness and stress fiber amount, assessed by simultaneous atomic force microscopy and live-cell fluorescence imaging,' Biomech. Model Mechanobiol., vol. 15, pp. 511–523, 2016. [38] P.-L. Kuo, C.-C. Charng, P.-C. Wu, and P.-C. Li, 'Shear-Wave Elasticity Measurement of Three-Dimensional Cell Cultures for Mechanobiology,' J. Cell Sci., vol. 130, pp. 292–302, 2016. [39] M. H. Zaman, L. M. Trapani, A. L. Sieminski, D. MacKellar, H. Gong, R. D. Kamm, et al., 'Migration of tumor cells in 3D matrices is governed by matrix stiffness along with cell-matrix adhesion and proteolysis,' Proc. Natl Acad. Sci. U. S. A., vol. 103, pp. 10889–10894, 2006. [40] L. V. Wang, 'Ultrasound-mediated biophotonic imaging: a review of acousto-optical tomography and photo-acoustic tomography,' Dis. Markers, vol. 19, pp. 123-138, 2004. [41] S. J. Kirkpatrick, D. D. Duncan, and E. M. Wells-Gray, 'Detrimental effects of speckle-pixel size matching in laser speckle contrast imaging,' Opt. Lett., vol. 33, pp. 2886-2888, 2008. [42] T. Moffitt, Y.-C. Chen, and S. A. Prahl, 'Preparation and characterization of polyurethane optical phantoms,' J. Biomed. Opt., vol. 11, p. 041103, 2006. [43] K. Daoudi, A.-C. Boccara, and E. Bossy, 'Detection and discrimination of optical absorption and shear stiffness at depth in tissue-mimicking phantoms by transient optoelastography,' Appl. Phys. Lett., vol. 94, p. 154103, 2009. [44] T. Moroishi, C. G. Hansen, and K.-L. Guan, 'The emerging roles of YAP and TAZ in cancer,' Nat. Rev. Cancer, vol. 15, pp. 73–79, 2015. [45] T. Panciera, L. Azzolin, M. Cordenonsi, and S. Piccolo, 'Mechanobiology of YAP and TAZ in physiology and disease,' Nat. Rev. Mol. Cell Biol., vol. 18, pp. 758–770, 2017. [46] S. E. Reid, E. J. Kay, L. J. Neilson, A. T. Henze, J. Serneels, E. J. McGhee, et al., 'Tumor matrix stiffness promotes metastatic cancer cell interaction with the endothelium,' EMBO J., vol. 36, pp. 2373–2389, 2017. [47] W. J. Polacheck, I. K. Zervantonakis, and R. D. Kamm, 'Tumor cell migration in complex microenvironments,' Cell Mol. Life Sci., vol. 70, pp. 1335–1356, 2013. [48] A. G. Clark and D. M. Vignjevic, 'Modes of cancer cell invasion and the role of the microenvironment,' Curr. Opin. Cell Biol., vol. 36, pp. 13–22, 2015. [49] K. M. Riching, B. L. Cox, M. R. Salick, C. Pehlke, A. S. Riching, S. M. Ponik, et al., '3D collagen alignment limits protrusions to enhance breast cancer cell persistence,' Biophys. J., vol. 107, pp. 2546–2558, 2014. [50] J. Soza-Ried and A. G. Fisher, 'Reprogramming somatic cells towards pluripotency by cellular fusion,' Curr. Opin. Genet. Dev., vol. 22, pp. 459–465, 2012. [51] F. K. Noubissi and B. M. Ogle, 'Cancer Cell Fusion: Mechanisms Slowly Unravel,' Int. J. Mol. Sci., vol. 17, p. 1587, 2016. [52] M. Álvarez-Dolado and M. Martínez-Losa, 'Cell fusion and tissue regeneration,' Adv. Exp. Med. Biol., vol. 713, pp. 161–175, 2017. [53] W. Han, S. Chen, W. Yuan, Q. Fan, J. Tian, X. Wang, et al., 'Oriented collagen fibers direct tumor cell intravasation,' Proc. Natl Acad. Sci. U. S. A., vol. 113, pp. 11208–11213, 2016. [54] M. Bernal, J.-L. Gennisson, P. Flaud, and M. Tanter, 'Correlation between classical rheometry and supersonic shear wave imaging in blood clots,' Ultrasound Med. Biol., vol. 39, pp. 2123–2136, 2013. [55] Y. Cheng, S. Li, R. J. Eckersley, D. S. Elson, and M.-X. Tang, 'Viscosity measurement based on shear-wave laser speckle contrast analysis,' J. Biomed. Opt., vol. 18, p. 121511, 2013. [56] P. Friedl and K. Wolf, 'Plasticity of cell migration: a multiscale tuning model,' J. Cell Biol., vol. 188, pp. 11–19, 2010. [57] J.-l. Gennisson, J. Provost, and T. Deffieux, '4-D ultrafast shear-wave imaging,' IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 62, pp. 1059–1065, 2015. [58] J. Tian, Q. Liu, X. Wang, P. Xing, Z. Yang, and C. Wu, 'Application of 3D and 2D quantitative shear wave elastography (SWE) to differentiate between benign and malignant breast masses,' Sci. Rep., vol. 7, p. 41216, 2017. [59] A. Ingle and T. Varghese, 'Three Dimensional Shear Wave Elastographic Reconstruction of Ablations,' in IEEE Eng. Med. Biol. Soc., Chicago, USA, 2014, pp. 2857–2860. [60] M. Wang, B. Byram, and M. Palmeri, 'Imaging transverse isotropic properties of muscle by monitoring acoustic radiation force induced shear waves using a 2-D matrix ultrasound array,' IEEE Trans. Med. Imaging, vol. 32, pp. 1671-1684, 2013. [61] H. Latorre-Ossa, 'In vivo monitoring of elastic changes during cancer development and therapeutic treatment,' Ph.D., Paris VII University Denis Diderot, Paris, France, 2012. [62] J. Zhu, L. Qi, Y. Miao, T. Ma, C. Dai, Y. Qu, et al., '3D mapping of elastic modulus using shear wave optical micro-elastography,' Sci Rep., vol. 6, p. 35499, 2016. [63] J. Sharpe, U. Ahlgren, P. Perry, B. Hill, A. Ross, J. Hecksher-Sørensen, et al., 'Optical projection tomography as a tool for 3D microscopy and gene expression studies,' Science, vol. 296, pp. 541-545, 2002. [64] A. Bassi, L. Fieramonti, C. D’Andrea, M. Mione, and G. Valentini, 'In vivo label-free three-dimensional imaging of zebrafish vasculature with optical projection tomography,' J. Biomed. Opt., vol. 16, p. 100502, 2011. [65] G. Feng, J. Chen, X. Lu, D. Han, and Y. Zeng, 'Laser speckle projection tomography,' Opt Lett., vol. 38, pp. 2654-2656, 2013. [66] A. C. Kak and M. Slaney, Principles of Computerized Tomographic Imaging: IEEE Press, 1998. [67] L. W. Goldman, 'Principles of CT and CT technology,' J. Nucl. Med. Technol., vol. 35, pp. 115-128, 2007. [68] A. B. Parthasarathy, W. J. Tom, A. Gopal, X. Zhang, and A. K. Dunn, 'Robust flow measurement with multi-exposure speckle imaging,' Opt. Express, vol. 16, pp. 1975–1989, 2008. [69] J. C. Ramirez-San-Juan, C. Regan, B. Coyotl-Ocelotl, and B. Choi, 'Spatial versus temporal laser speckle contrast analyses in the presence of static optical scatterers,' J. Biomed. Opt., vol. 19, p. 106009, 2014. [70] P. G. Vaz, A. Humeau-Heurtier, E. Figueiras, C. Correia, and J. Cardoso, 'Effect of static scatterers in laser speckle contrast imaging: an experimental study on correlation and contrast,' Phys. Med. Biol., vol. 63, p. 015024, 2017. [71] Y.-S. Yang, 'Shear Wave Computed Tomography,' Master, Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan, 2018. [72] M. J. Willemink, P. A. d. Jong, T. Leiner, L. M. d. Heer, R. A. J. Nievelstein, R. P. J. Budde, et al., 'Iterative reconstruction techniques for computed tomography Part 1: technical principles,' Eur. Radiol., vol. 23, pp. 1623-1631, 2013. [73] L. L. Geyer, U. J. Schoepf, F. G. Meinel, J. John W. Nance, G. Bastarrika, J. A. Leipsic, et al., 'State of the Art: Iterative CT Reconstruction Techniques,' Radiology, vol. 276, pp. 339-357, 2015. [74] M. Soleimani and T. Pengpen, 'Introduction: a brief overview of iterative algorithms in X-ray computed tomography,' Philos. Trans. A Math. Phys. Eng. Sci., vol. 373, p. 20140399, 2015. [75] M. Beister, D. Kolditz, and W. A. Kalender, 'Iterative reconstruction methods in X-ray CT,' Phys. Med., vol. 28, pp. 94-108, 2012. [76] J. Hsieh, B. Nett, Z. Yu, K. Sauer, J.-B. Thibault, and C. A. Bouman, 'Recent advances in CT image reconstruction,' Curr. Radiol. Rep., vol. 1, pp. 39-51, 2013. [77] Z. Zhu, K. Wahid, P. Babyn, D. Cooper, I. Pratt, and Y. Carter, 'Improved Compressed Sensing-Based Algorithm for Sparse-View CT Image Reconstruction,' Comput. Math. Methods Med., vol. 2013, p. 185750, 2013. [78] E. Candes and J. Romberg. (2005). l1-magic : Recovery of Sparse Signals via Convex Programming. Available: https://statweb.stanford.edu/~candes/l1magic/ [79] F. Krahmer, C. Kruschel, and M. Sandbichler, 'Total Variation Minimization in Compressed Sensing,' in Compressed Sensing and its Applications, H. Boche, G. Caire, R. Calderbank, M. März, G. Kutyniok, and R. Mathar, Eds., ed: Birkhäuser, Cham, 2017. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/70714 | - |
dc.description.abstract | 剪切波影像是一種非侵入式的定量彈性影像技術,可用於重建觀測物之彈性分佈。近年來,光學式剪切波影像系統的發展可實現高靈敏度、空間及時間解析度之彈性成像。此研究結合雷射光斑對比影像技術與剪切波彈性影像,發展了一套三維全域式雷射光斑對比剪切波影像系統。此技術利用因機械擾動造成的局部光斑模糊現象來偵測瞬態剪切波傳遞的狀態。二維 (X–Z) 剪切波彈性影像的仿體測試結果顯示,在剪切模量範圍為1.52 kPa至7.99 kPa的均質仿體中,剪切波速度估算誤差小於6%,而估計標準偏差則小於0.07 kPa。此外,系統之位移靈敏度可偵測到位移移動速度小於0.6 µm/ms。本研究架設及評估兩種三維雷射光斑剪切波彈性影像系統。第一套系統在不同的二維平面上對剪切波傳遞進行成像,利用不同平面的剪切波速度圖重建觀測物之三維彈性分佈。第二套系統採用電腦斷層掃描架構,利用不同角度的剪切波投影來重建剪切波波前之三維空間位置與形狀。因第二套系統架構能利用Time-of-flight演算法於剪切波徑向方向之傳遞路徑估算多方向剪切波傳遞速度,在評估複雜機械特性的觀測物具有優勢。本系統的三維空間解析度皆小於一毫米。然而,由於成像系統的景深以及位移靈敏度(在有靜態散射物質的情況)有限,沿著光軸的方向(Y方向)的有效成像深度大約為6.25 mm。因本系統可量測含有低散射的觀測物之彈性分佈,我們將影像系統應用於量測三維癌細胞培養系統內細胞外基質之空間和時間上的硬度變化並評估測量系統用於力學生物學的可行性。分析結果顯示兩種細胞培養系統(含有4 mg/ml Matrigel以及1mg/ml或2 mg/ml Collagen Type I)中主要的兩種基質纖維密度與量測到的剪切波速度俱有高度相關性,分別為r=0.832,P<0.001和r=0.642,P=0.024。此外,研究中觀察到細胞沿著細胞培養系統中的硬度梯度方向的移動現象,以及因局部基質的硬度所造成不同程度的細胞增生。因本系統可達到無需添加探針式的彈性測量,細胞與細胞微環境之間的雙向機械相互作用及所觀察到的硬度所介導的細胞行為並沒有被影像探針所干涉。此外,接近活體尺寸的細胞微環境之彈性變化資訊有助於提升對在癌症發展過程中所發生的複雜基質重塑機制的理解,進而研發新的癌症治療方法。 | zh_TW |
dc.description.abstract | The high spatial resolution and motion sensitivity of optical-based shear wave detection have made it an attractive technique in biomechanics studies with potential for improving the capabilities of ultrasound-based shear wave elasticity imaging. In this research, a laser speckle contrast shear wave imaging system was developed. The estimation of shear wave speed is based on the detection of the local blurring of the optical speckle pattern resulting from the mechanical disturbances induced by shear wave propagation. In two-dimensional (2D) imaging, the developed system can estimate the shear wave speed with an error of less than 6% on homogeneous phantoms with shear moduli ranging from 1.52 kPa to 7.99 kPa. The standard deviation of shear modulus estimation was less than 0.07 kPa and motion sensitivity of better than 0.6 µm/ms was demonstrated. In three-dimensional (3D) imaging, two system setups were devised. The first setup performed plane-by-plane 2D reconstruction of the shear wave speed maps at different positions by linearly translating the sample. The second setup, on the other hand, performed tomographic reconstruction of the shear wave wavefront by rotating the ultrasound transducer used for the induction of shear waves. The second setup has the advantage of multi-directional shear wave speed estimation in the radial direction. Thus, it can be beneficial for evaluating the elasticity of an anisotropic sample. The systems exhibit submillimeter spatial resolution in all three dimensions. Due to the limited depth-of-field and motion sensitivity (in the presence of static scatterers), the effective imaging depth along optical axis (Y direction) is approximately 6.25 mm. The applicability of the developed systems for in vitro mechanobiology study with 3D cancer cell culture systems is also explored. The shear wave speed measured for the cell culture sample was found to be strongly correlated with the extracellular matrix fiber density in two types of cell culture system (r=0.832 with P<0.001, and r=0.642 with P=0.024 for cell culture systems containing 4 mg/ml Matrigel with 1 mg/ml and 2 mg/ml collagen type I hydrogel, respectively). Cell migration along the stiffness gradient in the cell culture system as well as an association between cell proliferation and the stiffness of the local extracellular matrix was also observed. As the elasticity measurements can be performed without the need of exogenous probes, the developed system can be used to assist the study on how the microenvironmental stiffness interacts with cancer cell behaviors without possible adverse effects of the exogenous particles. In addition, providing information on the dynamics of the cell microenvironmental stiffness in a scale closer to the in vivo scenario may increase the understanding of the mechanism of the complex matrix remodeling occurs during cancer progression, which may lead to the improvements in cancer treatment strategies. | en |
dc.description.provenance | Made available in DSpace on 2021-06-17T04:35:52Z (GMT). No. of bitstreams: 1 ntu-107-D00945005-1.pdf: 86302848 bytes, checksum: 6cbd69629899849b6baa87aabca4fc1d (MD5) Previous issue date: 2018 | en |
dc.description.tableofcontents | ABSTRACT I
中文摘要 III CONTENT IV LIST OF FIGURES VII LIST OF TABLES XI CHAPTER 1. INTRODUCTION 1 1.1 ULTRASOUND-BASED SHEAR WAVE ELASTOGRAPHY 1 1.2 PARAMETERS IN DETERMINING THE QUALITY OF SHEAR WAVE ELASTOGRAPHY 3 1.3 OPTICAL-BASED SHEAR WAVE ELASTOGRAPHY 4 1.4 MECHANOBIOLOGY STUDY IN THREE-DIMENSIONAL CELL CULTURE 6 1.5 OBJECTIVES 8 CHAPTER 2. LASER SPECKLE CONTRAST SHEAR WAVE IMAGING: TWO-DIMENSIONAL IMAGING SYSTEM DEVELOPMENT 10 2.1 INTRODUCTION 10 2.2 PRINCIPLES OF LASER SPECKLE CONTRAST IMAGING 10 2.3 MATERIALS AND METHODS 11 2.3.1 System setup 11 2.3.2 Imaging processing 12 2.3.3 Result validation 13 2.3.4 Phantom 14 2.4 RESULTS 15 2.4.1 Experiments with the homogeneous phantoms 15 2.4.2 Experiment with the heterogeneous phantom containing stiff-plate inclusion in the X direction 18 2.4.3 Motion sensitivity 18 2.5 DISCUSSION 19 2.6 SUMMARY 20 CHAPTER 3. MECHANICAL MEASUREMENTS OF THREE-DIMENSIONAL CANCER CELL IN VITRO MODEL 22 3.1 INTRODUCTION 22 3.2 MATERIALS AND METHODS 23 3.2.1 Cell culture sample 23 3.2.2 Experiment setup 24 3.2.3 Imaging and post-imaging process 25 3.2.4 Immunofluorescence, cell count and size distribution analysis 26 3.3 RESULTS 27 3.3.1 Shear wave speed measurements of the 3D cell culture system 27 3.3.2 Immunofluorescence and H&E staining analysis 29 3.4 DISCUSSION 34 3.5 SUMMARY 36 CHAPTER 4. THREE-DIMENSIONAL SHEAR WAVE IMAGING BASED ON FULL-FIELD LASER SPECKLE CONTRAST IMAGING WITH ONE-DIMENSIONAL MECHANICAL SCANNING 37 4.1 INTRODUCTION 37 4.2 MATERIALS AND METHODS 37 4.2.1 System setup and imaging process 37 4.2.2 Phantoms 38 4.3 RESULTS 38 4.3.1 Spatial filtering for reducing the signal from outside of the depth-of-field of the imaging lens 38 4.3.2 Experiment with the heterogeneous phantom containing stiff-plate inclusion in Y direction 39 4.3.3 Three-dimensional shear wave imaging of a heterogeneous phantom with a stiff-cylinder inclusion 40 4.4 DISCUSSION 42 4.5 SUMMARY 42 CHAPTER 5. COMPUTED TOMOGRAPHIC SHEAR WAVE IMAGING 43 5.1 INTRODUCTION 43 5.2 COMPUTED TOMOGRAPHIC SHEAR WAVE IMAGING: PRINCIPLE AND IMAGE RECONSTRUCTION 43 5.3 MATERIALS AND METHODS 44 5.3.1 System setup and imaging acquisition 44 5.3.2 Phantoms 47 5.4 RESULTS 48 5.4.1. Three-dimensional visualization of the shear wave propagation 48 5.4.2. Three-dimensional volumetric reconstruction of the shear wave speed 49 5.5 DISCUSSIONS 52 5.6 SUMMARY 55 CHAPTER 6. CONCLUSIONS AND FUTURE WORKS 56 6.1 CONCLUSIONS 56 6.2 FUTURE WORKS 57 6.2.1 Improving the computed tomographic reconstruction algorithm for shear wave imaging 57 6.2.2 Three-dimensional shear wave imaging for three-dimensional cell culture system 58 REFERENCES 61 PUBLICATION LIST 68 | |
dc.language.iso | en | |
dc.title | 雷射光斑剪切波影像:系統開發與於力學生物學之應用 | zh_TW |
dc.title | Laser Speckle Contrast Shear Wave Imaging: System Development and Applications in Mechanobiology | en |
dc.type | Thesis | |
dc.date.schoolyear | 106-2 | |
dc.description.degree | 博士 | |
dc.contributor.oralexamcommittee | 宋孔彬,沈哲州,謝寶育,葉佳倫 | |
dc.subject.keyword | 雷射光斑對比影像,剪切波,彈性影像,三維細胞培養系統,力學生物學,電腦斷層掃描, | zh_TW |
dc.subject.keyword | Laser speckle contrast imaging,shear wave,elasticity imaging,three-dimensional cell culture,mechanobiology,computed tomography, | en |
dc.relation.page | 69 | |
dc.identifier.doi | 10.6342/NTU201802841 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2018-08-09 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 生醫電子與資訊學研究所 | zh_TW |
顯示於系所單位: | 生醫電子與資訊學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-107-1.pdf 目前未授權公開取用 | 84.28 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。