Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
    • 指導教授
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 工學院
  3. 環境工程學研究所
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/70631
標題: 探討脫氯對模擬建物自來水配管生物穩定性之影響
The Impact of Point-of-Entry Dechlorination on Biological Stability in Simulated Premise Plumbing System
作者: Tzu-Hsuan Fang
方子瑄
指導教授: 童心欣(Hsin-hsin Tung)
關鍵字: 自來水,脫氯,消毒副產物,生物穩定性,建物配管,總異營菌數,生物可利用有機碳,
drinking water,point-of-entry dechlorination,disinfection byproducts (DBPs),biological stability,premise plumbing,heterotrophic plate count (HPC),assimilable organic carbon (AOC),
出版年 : 2018
學位: 碩士
摘要: 供應穩定且安全的飲用水在現代社會是相當重要的議題。當自來水進入建物配管中,時常停滯的條件使餘氯與水中有機物反應出許多消毒副產物。尤其在台灣的公寓社區多數會使用水塔,因而增加了自來水在建物配管的停留時間。為了減少消毒副產物對人體暴露的風險,許多住戶使用全戶型脫氯淨水裝置去除水中的餘氯。本研究目標將探討脫氯之行為對於自來水生物穩定性之影響。研究期間定期於模擬間接供水系統採樣並分析水質,並比較脫氯前後水質之差異。總異營菌數(HPC)與生物可利用有機碳(AOC)為本次研究採用的生物穩定性指標參數。研究結果顯示脫氯後,系統出流水之消毒副產物濃度下降但水中總異營菌數顯著增加至10^5 CFU/ml。然而出流水之生物可利用有機碳降低至可抑制微生物再生長之閾值濃度(< 10 μg/L),因此出流水之總異營菌數於一個月後達到穩態而非持續上升。最後利用進流水之生物可利用有機碳計算之理論總異營菌數與實際檢測值相近,證明了出流水之總異營菌數之增加主要源自於進流水中的生物可利用有機碳。總結若是進流水之生物可利用有機碳高於閾值濃度,於建物配管前脫氯便會衝擊飲用水之生物穩定性。
The biological stability of drinking water is a crucial part for public health. In Taiwan, indirect water supply with extra water storage tank increases hydraulic retention time in premise plumbing and may increase disinfection byproduct (DBP) formation. Therefore, dechlorination devices are commonly used to reduce chlorine residual. The objective of this research was to explore the impact of point-of-entry dechlorination device on biological stability. A simulation of indirect water supply system was established and the water quality parameters were sampled and analyzed. Heterotrophic plate count (HPC) and assimilable organic carbon (AOC), carbon source directly support the microbial regrowth, are the main methods to access the biological stability. The results show that concentrations of DBPs in effluent were decreased and HPC were significantly increased to 10^5 CFU/ml after dechlorination. AOC in the effluent reached to the threshold of the nutrient scarcity (< 10 μg/L) that resulted in stable effluent HPC after one month. The theoretical HPC, calculated from the consumed AOC, was similar to the actual detected value. The result indicates that high amount of HPC in effluent is controlled by AOC in influent. To sum up, point-of-entry dechlorination could result in biological instability if AOC in influent is above the threshold of the nutrient scarcity.
URI: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/70631
DOI: 10.6342/NTU201802105
全文授權: 有償授權
顯示於系所單位:環境工程學研究所

文件中的檔案:
檔案 大小格式 
ntu-107-1.pdf
  未授權公開取用
6.38 MBAdobe PDF
顯示文件完整紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved