完整後設資料紀錄
DC 欄位值語言
dc.contributor.advisor林逸彬
dc.contributor.authorShu-Wei Liuen
dc.contributor.author劉書瑋zh_TW
dc.date.accessioned2021-06-17T01:41:30Z-
dc.date.available2022-08-08
dc.date.copyright2017-08-08
dc.date.issued2017
dc.date.submitted2017-07-27
dc.identifier.citationAdler, T. (2004). Lead: Washington’s Water Woes. Environmental Health Perspectives, 112(13), A735.
APHA, AWWA, and WEF. (2012) Standard Methods for the Examination of Water and Wastewater, 22nd ed.
AWWARF. (1990) Lead Control Stratefies. Colorado, Denver.
Bellinger, D., Sloman, J., Leviton, A., Rabinowitz, M., Needleman, H.L. and Waternaux, C. (1991) Low-Level Lead-Exposure and Childrens Cognitive Function In the Preschool Years. Pediatrics 87(2), 219-227.
Brian Conway. (2016) The Pittsburgh Water & Sewer Authority is working to address high lead levels, but misinformation and current testing practices could put residents at risk. Pittsburgh City Paper. Retrieved from https://www.pghcitypaper.com/pittsburgh/the-pittsburgh-water-and-sewer-authority-is-working-to-address-high-lead-levels-but-misinformation-and-current-testing-practices-could-put-resi/Content?oid=1971618&showFullText=true
Bryan, R., Swistock, M., Stephanie, C. and William, E. (2009) Drinking water quality in rural Pennsylvania and the effect of management practices. The Center for Rural Pennsylvania [Online].
Cardew, P.T. (2003) A method for assessing the effect of water quality changes on plumbosolvency using random daytime sampling. Water Research 37(12), 2821-2832.
Cartier, C., Laroche, L., Deshommes, E., Nour, S., Richard, G., Edwards, M. and Prevost, M. (2011) Investigating dissolved lead at the tap using various sampling protocols. Journal American Water Works Association 103(3), 55-+.
City of Flint. (2016). State of emergency declared in the city of Flint. Retrieved from
http:/www.cityofflint.com/state-of-emergency/
Clark, B., Masters, S. and Edwards, M. (2014) Profile Sampling To Characterize Particulate Lead Risks in Potable Water. Environmental Science & Technology 48(12), 6836-6843.
Cornwell, D.A., Brown, R.A. and Via, S.H. (2016) National Survey of Lead Service Line Occurrence (vol 108, E182, 2016). Journal American Water Works Association 108(5), 87-87.
Del Toral, M.A., Porter, A. and Schock, M.R. (2013) Detection and Evaluation of Elevated Lead Release from Service Lines: A Field Study. Environmental Science & Technology 47(16), 9300-9307.
Deshommes, E., Laroche, L., Nour, S., Cartier, C. and Prevost, M. (2010) Source and occurrence of particulate lead in tap water. Water Research 44(12), 3734-3744.
Dryer, D.J. and Korshin, G.V. (2007) Investigation of the reduction of lead dioxide by natural organic matter. Environmental Science & Technology 41(15), 5510-5514.
Edwards, M. and Dudi, A. (2004) Role of chlorine and chloramine in corrosion of lead-bearing plumbing materials. Journal American Water Works Association 96(10), 69-81.
Eur-Lex. (2015) Official Journal of the European Union. amending Annexes II and III to Council Directive 98/83/EC on the quality of water intended for human consumption.
Glammar, D.E. (2010) Water chemistry effects on dissolution rates of lead corrosion products, Water Research Foundation.
Harvey, P.J., Handley, H.K. and Taylor, M.P. (2016) Widespread copper and lead contamination of household drinking water, New South Wales, Australia. Environmental Research 151, 275-285.
Hayes, C. (2010) Best practice guide on the control of lead in drinking water, IWA publishing.
Hayes, C.R., Croft, N., Phillips, E., Craik, S. and Schock, M. (2016) An evaluation of sampling methods and supporting techniques for tackling lead in drinking water in Alberta Province. Journal of Water Supply Research and Technology-Aqua 65(5), 373-383.
Health Canada. (2009) Guidance on controlling corrosion in drinking water distribution systems. Health Canada, Ottawa.
Hong Kong. (2015) Report of the Task Force on Investigation of Excessive Lead Content in Drinking Water.
Jiquanda Johnson. (2015) Four takeaways from the Flint Water Advisory Task Force preliminary report, MLive. Retrieved from
http://www.mlive.com/news/flint/index.ssf/2015/12/five_takeways_for_the_flint_wa.html
Kim, E.J. and Herrera, J.E. (2010) Characteristics of Lead Corrosion Scales Formed during Drinking Water Distribution and Their Potential Influence on the Release of Lead and Other Contaminants. Environmental Science & Technology 44(16), 6054-6061.
Liam Stack. (2017) Lead Levels in Flint Water Drop, but Residents Still Can’t Drink It, The New York Times. Retrieved from
https://www.nytimes.com/2017/01/24/us/flint-michigan-water.html
Lin, Y.P. and Valentine, R.L. (2008) The release of lead from the reduction of lead oxide (PbO2) by natural organic matter. Environmental Science & Technology 42(3), 760-765.
Lin, Y.P. and Valentine, R.L. (2009) Reduction of Lead Oxide (PbO2) and Release of Pb(II) in Mixtures of Natural Organic Matter, Free Chlorine and Monochloramine. Environmental Science & Technology 43(10), 3872-3877.
Lytle, D.A. and Schock, M.R. (2005) Formation of Pb(IV) oxides a in chlorinated water. Journal American Water Works Association 97(11), 102-114.
Masters, S., Welter, G.J. and Edwards, M. (2016) Seasonal Variations in Lead Release to Potable Water. Environmental Science & Technology 50(10), 5269-5277.
Nakamura, David (2005). Lead Report Suggests Better Communications. The Washington Post. Washington, DC. p. B10.
Ng, D.Q. and Lin, Y.P. (2016) Evaluation of Lead Release in a Simulated Lead-Free Premise Plumbing System Using a Sequential Sampling Approach. International Journal of Environmental Research and Public Health 13(3).
Papanikolaou, N.C., Hatzidaki, E.G., Belivanis, S., Tzanakakis, G.N. and Tsatsakis, A.M. (2005) Lead toxicity update. A brief review. Medical Science Monitor 11(10), RA329-RA336.
Pieper, K.J., Krometis, L.A., Gallagher, D., Benham, B. and Edwards, M. (2015) Profiling Private Water Systems to Identify Patterns of Waterborne Lead Exposure. Environmental Science & Technology 49(21), 12697-12704.
Shock, M. R. (1990) Cause of temporal variability of lead in domestic plumbing systems. Environmental Monitoring and Assessment, 15(1), 59-82.
Shock, M. R., Tully, J. and Cahalan, K. (2016) What Do Lead and Copper Sampling Protocols Mean, and Which Is Right for You? 17th Canadian National Conference on Drinking Water, At Ottawa, ON.
Taiwan Water Department. (2015) 臺北自來水鉛管問題說明懶人包. Retrieved from http://www.water.gov.taipei/ct.asp?xItem=127272284&CtNode=85025&mp=114001
Taiwan EPA. (2004) 水中金屬檢測方法-石墨爐式原子吸收光譜法 (NIEA W303.51A).
Retrieved from http://www.niea.gov.tw/niea/WATER/W30351A.htm
Taiwan EPA. (2014) 飲用水水質標準.
Retrieved from http://ivy5.epa.gov.tw/docfile/090040.pdf
Taiwan EPA. (2015) 飲用水水質採樣方法-自來水系統 (NIEA W101.55A).
Retrieved from http://www.niea.gov.tw/niea/pdf/WATER/W10155A.pdf
Triantafyllidou, S., Schock, M.R., DeSantis, M.K. and White, C. (2015) Low Contribution of PbO2-Coated Lead Service Lines to Water Lead Contamination at the Tap. Environmental Science & Technology 49(6), 3746-3754.
Udn Global. (2016) 透視:誰來負責!美國密西根的「鉛水危機」. Retrieved from https://global.udn.com/global_vision/story/8662/1435398
UK Government. (1989) The Water Supply (Water Quality) Regulations 1989. Statutory Instrument 1989, No. 1147, HMSO.
US EPA. (1991) Maximum contamination level goals and national primary drinking water regulations for lead and copper. Final Rule. Fed. Regist. 56(110), 26460-26564
US EPA (1993) Lead and your drinking water: Actions you can take to reduce lead in drinking water. EPA 810-F-93-001.
US EPA (2008) New Jersey Private Well Testing Act Program. NJ Department of Environmental Protection Division of Water Supply / Bureau of Safe Drinking Water and Division of Science, Research and Technology.
US EPA (2016) Lead and Copper Rule Revisions White Paper. U. S. Environmental Protection Agency Office of Water Washington, DC 20460
US EPA (2016) Clarification of Recommended Tap Sampling Procedures for Purposes of the Lead and Copper Rule. U. S. Environmental Protection Agency Office of Water Washington, DC 20460
Vasquez, F.A., Heaviside, R., Tang, Z.J. and Taylor, J.S. (2006) Effect of free chlorine and chloramines on lead release in a distribution system. Journal American Water Works Association 98(2), 144-154.
Weizsaecker, K. (2003) Lead toxicity during pregnancy. Primary care update for OB/GYNS 10(6), 304-309.
Welter, G. (2016) Typical Kitchen Faucet-Use Flow Rates: Implications for Lead Concentration Sampling. Journal American Water Works Association 108(7), 85-85.
Xie, Y. (2010) Dissolution, Formation, and Transformation of the Lead Corrosion Product PbO 2: Rates and Mechanisms of Reactions that Control Lead Release in Drinking Water Distribution Systems.
Zhang, Y. and Lin, Y.P. (2011) Determination of PbO2 Formation Kinetics from the Chlorination of Pb(II) Carbonate Solids via Direct PbO2 Measurement. Environmental Science & Technology 45(6), 2338-2344.
dc.identifier.urihttp://tdr.lib.ntu.edu.tw/jspui/handle/123456789/67637-
dc.description.abstract世界各國在1980年代開始禁止使用鉛管於自來水管網當中。然而,現今許多國家包含臺灣在內,仍然有許多鉛管存在於老舊建築物的配水系統,此外,現今所謂之無鉛管材其含鉛量並不為零。近期美國對於自來水鉛污染的問題進行大範圍的採樣調查,發現自來水鉛污染的問題普遍存在,使得公共用水的安全問題重新受到重視。本研究為調查臺灣大學校園內一已知有鉛管之老舊建築物—二號館之自來水總鉛與溶解態鉛的濃度,並探討自來水中鉛濃度與各項水質參數之關係,以及使用不同採樣方法對於所測得鉛濃度的差異。最後發現在七個採樣點中,於四個已知含有鉛管存在的採樣點測到超過臺灣法規標準10 µg/L之平均總鉛濃度,不同採樣方法包括第一升採樣、序列採樣、隨機時間採樣和放流採樣,所採集到的鉛濃度也有顯著的不同。此外,各項水質參數與鉛濃度之間無發現明顯之相關性。zh_TW
dc.description.abstractLead pipes have been banned in drinking water system in most countries in the 1980s. However, lead pipes still exist in old plumbing system. Furthermore, lead is commonly used as an additive in the manufacturing of various plumbing materials. The survey of lead contamination in tap water conducted in the US showed that lead contamination could be a widespread problem. In this study, a sampling campaign was conducted for 7 faucets in an old building (Building No.2) on the National Taiwan University campus, with a total of 9 sampling events. Total lead and soluble lead were measured along with other water quality parameters in this sampling campaign. Lead concentrations in samples collected by different sampling methods were compared. In 4 out of the 7 sampling sites where the lead pipes still exist, average total lead concentration greater than 10 µg/L were observed. Samples collected by four different sampling methods, namely first draw sampling, sequential sampling, random daytime sampling and flushing sampling showed variable lead levels in tap water. There were no obvious correlations between lead concentration and water quality parameters.en
dc.description.provenanceMade available in DSpace on 2021-06-17T01:41:30Z (GMT). No. of bitstreams: 1
ntu-106-R04541120-1.pdf: 1191546 bytes, checksum: a34a9429c6219230d802fbfeb74a79af (MD5)
Previous issue date: 2017
en
dc.description.tableofcontentsContents
摘要....................................................................................................................................I
Abstract.............................................................................................................................II
Contents...........................................................................................................................III
Content of Figures............................................................................................................V
Content of Tables..........................................................................................................VIII
Chapter 1 Introduction…………………………………...………………………………1
1.1 Background………....…………..………….……………………………………...1
1.2 Research objectives…………….…………….....…………...........................….2
Chapter 2 Literature Review..............................................................................................4
2.1 Drinking water standard of lead and notable lead contamination incidents…………………………………………………………….………………....4
2.2 Sampling methods for lead......................................................................................5
2.3 Effects of water parameter on lead release………....………................................8
Chapter 3 Materials and Methods....................................................................................10
3.1 Sampling location…………………......................................................................10
3.2 Sampling campaign and sampling methods..........................................................14
3.3 Analytical methods................................................................................................16
Chapter 4 Results and Discussion...................................................................................18
4.1 QA/QC of tap water sampling and lead measurement using GFAAS………….18
4.2 Lead concentration in tap water in Building NO.2……………………………..20
4.3 Effectiveness of flushing in reducing lead level………..……………...............36
4.4 Water quality parameters and lead concentration……………………..………..42
Chapter 5 Conclusions and Recommendations...............................................................45
5.1 Conclusions...........................................................................................................45
5.2 Recommendations.................................................................................................46
Reference List..................................................................................................................48
Appendix A......................................................................................................................56
dc.language.isoen
dc.subject自來水zh_TW
dc.subject鉛zh_TW
dc.subject採樣方法zh_TW
dc.subject水質參數zh_TW
dc.subjecttap wateren
dc.subjectLeaden
dc.subjectwater quality parametersen
dc.subjectsampling methodsen
dc.title台灣大學校園內一老舊建築物自來水含鉛濃度調查zh_TW
dc.titleSurvey of lead concentration in tap water in an old building on the National Taiwan University campusen
dc.typeThesis
dc.date.schoolyear105-2
dc.description.degree碩士
dc.contributor.oralexamcommittee王根樹,童心欣
dc.subject.keyword鉛,自來水,採樣方法,水質參數,zh_TW
dc.subject.keywordLead,tap water,sampling methods,water quality parameters,en
dc.relation.page62
dc.identifier.doi10.6342/NTU201702072
dc.rights.note有償授權
dc.date.accepted2017-07-28
dc.contributor.author-college工學院zh_TW
dc.contributor.author-dept環境工程學研究所zh_TW
顯示於系所單位:環境工程學研究所

文件中的檔案:
檔案 大小格式 
ntu-106-1.pdf
  未授權公開取用
1.16 MBAdobe PDF
顯示文件簡單紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved