請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/6548
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 陳達仁 | |
dc.contributor.author | Tzong-Ming Wu | en |
dc.contributor.author | 吳宗明 | zh_TW |
dc.date.accessioned | 2021-05-17T09:14:35Z | - |
dc.date.available | 2017-08-22 | |
dc.date.available | 2021-05-17T09:14:35Z | - |
dc.date.copyright | 2012-08-22 | |
dc.date.issued | 2012 | |
dc.date.submitted | 2012-08-15 | |
dc.identifier.citation | ﹝1﹞ World Health Organization, Global Strategy on Diet, Physical Activity and Health, Geneva, WHO, May, 2004.
﹝2﹞ European Commission, EU physical activity guidelines. Recommended policy actions in support of health-enhancing physical activity. Brussels: EU Working Group - Sport and Health, 2008. ﹝3﹞ U. S. Department of Health and Human Services, Physical Activity Guidelines for Americans, October, 2008. ﹝4﹞ Caspersen C. J., Powell K. E., Chritenson G. M., Physical activity, exercise, and physical fitness, Public Health Report 1985;100:125-131. ﹝5﹞ Department of Health and Human Services. Physical Activity Fundamental to Preventing Disease, June 20, 2002. ﹝6﹞ Warburton D. E. R., Nicol C. W., and Bredin S. S. D., Health benefits of physical activity: the evidence, Canadian Medical Association Journal 2006; 174(6): 801-809. ﹝7﹞ Kruk J., Physical activity and health, Asian Pacific Journal of Cancer Prevention 2009; 10: 721-728. ﹝8﹞ Haskell W. L., Lee, I. M., Pate, R. R., Powell, K. E., Blair, S. N., Franklin, B. A., Macera, C. A., Heath, G. W., Thompson, P. D., and Bauman, A., Physical activity and public health: updated recommendation for adults from the ACSM and AHA, Circulation 2007;116:1081-1093. ﹝9﹞ American College of Sports Medicine, Position stand: progression models in resistance training for healthy adults, Medicine & Science in Sports & Exercise 2002;34:364-380. ﹝10﹞ Faigenbaum A. D., Kraemer W. J., Blimkie C. J. R., Jeffreys I., Micheli L. J., Nitka M., and Rowland T. W., Youth resistance training: Updated position statement paper from the National Strength and Conditioning Association, Journal of Strength & Conditioning Research 2009;23(5):S60–S79. ﹝11﹞ Williams M. A., Haskell, W. L., Ades, P. A., Amsterdam, E. A., Bittner, V., Franklin, B. A., Gulanick, M., Laing, S. T., and Stewart, K. J., Resistance Exercise in Individuals With and Without Cardiovascular Disease: 2007 update, Circulation 2007;116:572-584. ﹝12﹞ Ries A. L., Bauldoff G. S., Carlin B. W., Casaburi, R., Emery C. F., Mahler D. A., Make B., Rochester C. L., ZuWallack R., and Herrerias C., Pulmonary Rehabilitation: Joint ACCP/AACVPR Evidence-Based Clinical Practice Guidelines, Chest 2007;131:4S-42S. ﹝13﹞ Sigal R. J., Kenny G. P., Wasserman, D. H., Castaneda-Sceppa C., and White R. D., Physical Activity/Exercise and Type 2 Diabetes: A consensus statement from the American Diabetes Association, Diabetes Care 2006;29(6): 1433-1438. ﹝14﹞ Pollock M. L. and Vincent K. R., Resistance training for health, Presidents Council Physical Fitness Sports Research Digest 1996;2(8):1-9. ﹝15﹞ Stone M., Plisk S., and Collin D., Training principles: evaluation of modes and methods of resistance training--a coaching perspective, Sports Biomechanics 2002;1(1):79-103. ﹝16﹞ United Nations Department of Economic and Social Affair, Population Division, World Population Prospects: The 2010 Revision, New York, 2011. ﹝17﹞ http://esa.un.org/unpd/wpp/unpp/panel_population.htm. ﹝18﹞ Mackay J. and Mensah G. A., The atlas of heart disease and stroke, Geneva (Switzerland): World Health Organization, 2004. ﹝19﹞ Roger V. L. et al., Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association, Circulation 2012;125: e2-e220. ﹝20﹞ Krebs H. I., Hogan N., Aisen M. L., and Volpe B. T., Robot-aided neurorehabilitation, IEEE Transactions on Rehabilitation. Engineering 1998;6: 75-87. ﹝21﹞ Burgar C. G., Lum P. S., Shor P. C., and Machiel H. F. Van der Loos, Development of Robots for Rehabilitation Therapy: The Palo Alto VA/Stanford experience, Journal of Rehabilitation Research and Development 2000; 37(6): 663-673. ﹝22﹞ Loureiro R. , Amirabdollahian F. , Topping M., Driessen B., and Harwin W., Upper Limb Robot Mediated Stroke Therapy—GENTLE/s Approach, Autonomous Robots 2003; 15(1): 35-51. ﹝23﹞ Reinkensmeyer D. J., Kahn L. E., Averbuch M., Mckenna-Cole A., Schmit B. D., and Rymer W. Z., Understanding and Treating Arm Movement Impairment after Chronic Brain Injury: Progress with the ARM guide, Journal of Rehabilitation Research and Development 2000; 37(6): 653-662. ﹝24﹞ Riener R., Nef T., and Colombo G., Robot-aided neurorehabilitation of the upper extremities, Medical and Biological Engineering and Computing, 2005; 43: 2-10. ﹝25﹞ Prange G. B., Jannink M. J. A., Groothuis-Oudshoorn C. G. M., Hermens H. J., and IJzerman M. J., Systematic review of the effect of robot-aided therapy on recovery of the hemiparetic arm after stroke, Journal of Rehabilitation Research and Development 2006; 43(2): 171-184. ﹝26﹞ Kwakkei G., Kollen B. J., and Krebs H. I., Effects of robot-assisted therapy on upper limb recovery after stroke: a systematic review, Neurorehabilitation and Neural Repair 2008; 22(2): 111-121. ﹝27﹞ Lo H. S. and Xie S. Q., Exoskeleton robots for upper-limb rehabilitation: State of the art and future prospects, Medical Engineering and Physics 2012; 34: 261-268. ﹝28﹞ Zoss A. B., Kazerooni H., and Chu A., Biomechanical design of the Berkeley Lower Extremity Exoskeleton (BLEEX), IEEE/ASME Trans. Mechatronics 2006; 11(2): 128–138. ﹝29﹞ Kawamoto H. and Sankai Y., Power assist system HAL-3 for gait disorder person, in Proc. Int. Conf. Comput. Helping People Special Needs (ICCHP) (Lecture Notes on Computer Science), vol. 2398, Berlin, Germany: Springer-Verlag, 2002. ﹝30﹞ Housman S. J., Rahman V. L.T., Sanchez R. J. Jr., and Reinkensmeyer D. J., Arm-Training with T-WREX After Chronic Stroke: Preliminary Results of a Randomized Controlled Trial, Rehabilitation Robotics, ICORR 2007. IEEE 10th International Conference: 562-568. ﹝31﹞ Sanchez, R. J., Wolbrecht, E. T., Smith R., Liu J., Rao S., Cramer S., Rahman T., Bobrow J. E., and Reinkensmeyer D. J., A pneumatic robot for re-training arm movement after stroke: Rationale and mechanical design, in Rehabilitation Robotics, 2005, ICCOR 2005, 9th International Conference, 2005: 500-504. ﹝32﹞ Nef T., Guidali M., and Riener R., ARMin III-arm therapy exoskeleton with an ergonomic shoulder actuation, Applied Bionics and Biomechanics 2009; 6: 127-142. ﹝33﹞ Balasubramanian S., Wei R., Perez M., Shepard B., Koeneman E., Koeneman J., and He J., RUPERT: An Exoskeleton Robot for Assisting Rehabilitation of Arm Functions, Virtual Rehabilitation, 2008: 163-167. ﹝34﹞ Perry J. C., Rosen J., and Burns S., Upper-limb powered exoskeleton design, IEEE/ASME Transactions on mechatronics 2007; 12(4): 408-417. ﹝35﹞ Klein J., Spencer S. J., Allington J., Minakata K., Wolbrecht E. T., Smith R., Bobrow J. E., and Reinkensmeyer D. J., Biomimetric Orthosis for the Neurorehabilitation of the Elbow and Shoulder (BONES), Proceedings of the 2nd Biennial IEEE/RAS-EMBS internal Conference on Biomedical Robotics and Biomechronics, Scottsdale, AZ, USA, Oct., 2008: 535-541. ﹝36﹞ Tsagarakis N. G., and Caldwell D. G., Development and Control of a ‘Soft-Actuated’ Exoskeleton for Use in Physiotherapy and Training, Autonomous Robots 2003; 15: 21–33. ﹝37﹞ Arno H. A. Stienen , Edsko E. G. Hekman, Alfred C. Schouten, Frans C. T. van der Helm, and Herman van der Kooij Suitability of hydraulic disk brakes for passive actuation of upper-extremity rehabilitation exoskeleton, Applied Bionics and Biomechanics 2009; 6(2): 103-114. ﹝38﹞ Gijbels D., Lamers L., Kerkhofs L., Alders G., Knippenberg E., and Feys P., The Armeo Spring as training tool to improve upper limb functionality in multiple sclerosis: a pilot study, Journal of NeuroEngineering and Rehabilitation 2011; 8(1): 5. ﹝39﹞ Rocon E., Belda-Lois J. M., Ruiz A. F., Manto M., Moreno J. C., and Pons J. L., Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression, IEEE Transactions on Neural Systems and Rehabilitation Engineering 2007; 15(3): 367-378. ﹝40﹞ Mikołajewska E., and Mikołajewski D., Exoskeletons in Neurological Diseases– Current and Potential Future Applications, Adv Clin Exp Med 2011; 20(2): 227–233. ﹝41﹞ Voris H. C., Handle and Exercise Arm Assembly for Use with Exercise Machine, U. S. Patent 6,394,937, May 28, 2002. ﹝42﹞ Webber R. T., Hockridge B., and Meredith J. O., Rigid Arm Pull Down Exercise Machine, U. S. Patent, 7601187 B2, Oct. 13, 2009. ﹝43﹞ Webber R. T., Hockridge B., and Meredith J. O., Chest Press Exercise Machine with Self-Aligning Pivoting Upper Support, U. S. Patent 7670269 B2, Mar. 2, 2010. ﹝44﹞ Liao C. S., Arm Exerciser, U. S. Patent 7,235,038 B2, June 26, 2007. ﹝45﹞ Laudone J. A., Jointed Bar for an Exercise Machine, U. S. Patent, 5613928, Mar. 25, 1997. ﹝46﹞ Howell L. L. and Magleby S. P., Substantially Constant-Force Exercise Machine, U. S. Patent 7,060,012, Jun. 13, 2006. ﹝47﹞ Lu E. C., Wang R. H., Heebert D., Boger J., Galea M. P., and Mihailidis A., The development of an upper limb stroke rehabilitation robot: identification of clinical practices and design requirements through a survey of therapists, Disability and Rehabilitation, Assistive Technology 2011; 6(5): 420-431. ﹝48﹞ Garcia N., Sabater-Navarro J. M., Gugliemeli E., and Casala A., Trends in rehabilitation robotics, Medical Biological Engineering & Computing 2011; 49: 1089-1091. ﹝49﹞ Brochard S., Robertson J., Me´de´e B., and Re´my-Ne´ris O., What’s new in new technologies for upper extremity rehabilitation?, Current Opinion in Neurology 2010; 23: 683–687. ﹝50﹞ Oatis C. A., Kinesiology: The Mechanics & Pathomechanics of Human Movement, second ed., Lippincott Williams & Wilkins, Baltimore, 2009. ﹝51﹞ Hisamoto S., and Higuchi M., Age-related Changes in Muscle Strength of Healthy Japanese, Standardization Center, NITE, Osaka, Japan, Human and Welfare Technology Division, 2007. ﹝52﹞ Hass C. J., Feigenbaum M. S., and Franklin B. A., Prescription of Resistance Training for Healthy Populations, Sports Medicine. 2001; 31(14): 953-964. ﹝53﹞ Teixeira-Salmela L. F., Olney S., Nadeau J. S., and Brouwer B., Muscle Strengthening and Physical Conditioning to Reduce Impairment and Disability in Chronic Stroke Survivors, Archives Physical Medicine and Rehabilitation 1999; 80(10): 1211-1218. ﹝54﹞ Scarborough D. M., Krebs D. E., and Harris B. A., Quadriceps Muscle Strength and Dynamic Stability in Elderly Persons, Gait & Posture 1999; 10(1): 10-20. ﹝55﹞ Denavit J. and Hartenberg R. S., Kinematic notation for lower pair mechanisms based on matrices, ASME Journal of Applied Mechanics 1955; 77: 215-221. ﹝56﹞ Baechle T. R. and Earle R., Essentials of Strength Training and Conditioning, Human Kinetics, National Strength & Conditioning Association, U.S., 2000. ﹝57﹞ Klopcar N., and Lenarcic J., Kinematic Model for Determination of Human Arm Reachable Workspace, Meccanica 2005; 40(2): 203-219. ﹝58﹞ Banala S. K., Agrawal S. Fattah K., Krishnamoorthy A., V., Hsu W. L., Scholz J., and Rudlph K., Gravity-Balancing Leg Orthosis and Its Performance Evaluation, IEEE Trans on Rob 2006; 22(6): 1228-1239. ﹝59﹞ Barents R., Schenk M., Van Dorsser W. D., Wisse B.M., and Herder J. L., Spring-to-spring Balancing as Energy-free Adjustment Method in Gravity Equilibrators, Proc. ASME Int Des Eng Tech Conf Comput Inf Eng Inf. Eng. Conf. DETC 7 (part B) 2009; 689-700. ﹝60﹞ Hamill J. and Knutzen K. M., Biomechanical Basis of Human Movement, third ed., Lippincott Williams & Wilkins, Baltimore, 2009. ﹝61﹞ Clauser C. E., McConville J. T., and Young J. W., Weight, volume, and center of mass of segments of the human body, Aerospace Medical Research Laboratories, Wright-Patterson Air Force Base, Dayton, Ohio, AMRL-TR-69-70, 1969. ﹝62﹞ The Stock Precision Engineered Components (SPEC), Associated Spring , [Online].Available:http://springming.so-buy.com/ezfiles/springming/img/img/61161/SPEC-04E.pdf. ﹝63﹞ Li Z. and Kota S., Virtual Prototyping and Motion Simulation with ADAMS, Journal of Computing and Information Science in Engineering 2001; 1(3): 276-279. ﹝64﹞ Renault M. and Ouezdou F. B., Dynamic simulation of hand-forearm system, IEEE International Workshop on Robot and Human Interactive Communication 2001: 20-25. ﹝65﹞ Li J.,Cheng Q., Liang H., and Guo Z., The Motion Simulation of Human Lower Extremity Based on Dynamics, 7th Asian-pacific Conference on Medical and Biological Engineering IFMBE Proceedings 2008; 19 (part 5): 151-154. ﹝66﹞ Yin X. and Xu Y., Design and Simulation of Chinese Massage Robot Based on Parallel Mechanism, International Conference on Mechanic Automation and Control Engineering (MACE) 2010: 2512-2515. ﹝67﹞ Naval Biodynamics Laboratory, Anthropometry and Mass Distribution for Human Analogues, Volume I: Military Male Aviators, Naval Medical Research and Development Command Bethesda, New Orleans, LA. 1988. ﹝68﹞ Chandler R. F., Clauser C. E., McConville J. T., Reynolds H. M., and Young J. W., Investigation of Inertial Properties of the Human Body, Aerospace Medical Research Laboratory, Wright-Patterson AFB, Ohio, AFAMRL-TR-74-137, 1974. ﹝69﹞ Institute of Occupational Safety & Health, 2008, [Online]. Available: http://www.iosh.gov.tw/Publish.aspx?cnid=26&P=812 ﹝70﹞ Kraemer, W.J. and Ratamess, N.A., Fundamentals of resistance training: progression and exercise prescription, Medicine and Science in Sports and Exercise. 2004; 36(4): 674-688. ﹝71﹞ Taylor, N.F., Dodd, K.J., and Damiano, D. L., Progressive resistance exercise in physical therapy: A summary of systematic reviews, Physical. Therapy. 2005; 5(11): 1208-1223. ﹝72﹞ Risser W. L., Weight-training injuries in children and adolescents, Amercian Family Physician. 1991; 44: 2104-2110. ﹝73﹞ Kerr, Z. Y., Collins C. L., and Comstock R. D., Epidemiology of weight training-related injuries presenting to United States emergency departments, 1990 to 2007, The American Journal of Sports Medicine, Apr. 2010; 38(4): 765-771. ﹝74﹞ Lavallee M. E. and Balam T., An overview of strength training injuries: acute and chronic, Current sports Medicine Report 2010; 9(5): 307-313. ﹝75﹞ Buckley, M. A., Yardley, A., Johnson, G. R., and Carus, D. A., Dynamics of the upper limb during performance of the tasks of everyday living-a review of the current knowledge base,” Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 1996; 210: 241-247. ﹝76﹞ Myer, K., Biomedical Engineering and Design Handbook, 2nd ed., McGraw-Hill, New York, 2009. ﹝77﹞ Hollerbach, J. M. and Flash, T, Dynamic interactions between limb segments during planar arm movement, Biological Cybernetics 1982; 44(1): 67-77. ﹝78﹞ Nef, T., Mihelj, M., and Riener, R., ARMin: a robot for patient-cooperative arm therapy, Medical and Biological Engineering and Computing 2007; 45: 887-900. ﹝79﹞ Nagarsheth H. J., Savsani P. V., and Patel M. A., Modeling and Dynamics of Human Arm, 4th IEEE Conference on Automation. Science and Engineering, Washington 2008; 924-928. ﹝80﹞ Apkarian J. Naumann S., and Cairns B., A three-dimensional kinematic and dynamic model of the lower limb, Journal of Biomechanics 1989;22(2): 143-155. ﹝81﹞ Requejo P. S., Wahl D. P., Bontrager E. L., Newsam C. J., Gronley J. K., Mulroy S. J., and Perry, J., Upper extremity kinetics during Lofstrand crutch-assisted gait, Medical Engineering and Physics. 2005; 27: 19-29. ﹝82﹞ Thomas J. S., Corcos D. M., and Hasan Z., Kinematic and kinetic constraints on arm, trunk, and leg segments in target-reaching movement, Journal of Neurophysiology. 2005; 93: 352-364. ﹝83﹞ Shemmell J.,Corcos D.M., and Hasan Z., Kinetic and kinematic adaptation to anisotropic load, Experimental Brain Research 2009;192:1-8. ﹝84﹞ Nagano A., Yoshioka S., Komura T., Himeno R., and Fukashiro, S., A three-dimensional linked segment model of the whole human body, International Journal of Sport and Health Science 2005; 3: 311-325. ﹝85﹞ AbdulRahman S. A., Rambely A. S., and Ahmad R. R., A biomechanical model via Kane’s equation─solving trunk motion with load carriage, American Journal of Scientific and Industrial Research 2011; 2(4): 678-685. ﹝86﹞ Anglin C and Wyss U.P., Review of arm motion analyses, Proceedings of the Institution of Mechanical Engineers; Part H: Journal of Engineering in Medicine 2000; 214(5): 541-555. ﹝87﹞ Richards J.G., The measurement of human motion: A comparison of commercially available system, Human. Movement. Science. 1999; 18: 589-602. ﹝88﹞ Zhou H. and Hu H., Human motion tracking for rehabilitation-A survey, Biomed. Signal Process Control 2008; 3: 1-18. ﹝89﹞ Cappozzo A., Croce U.D., Leardini A., and Chiari L., Human movement analysis using sterophotogrammetry, Part 1: theoretical background, Gait and Posture 2005; 21: 186-196. ﹝90﹞ Chiari L., Croce U.D., Leardini A., and Cappozzo, A., Human movement analysis using sterophotogrammetry, Part 2: Instrumental errors, Gait and Posture 2005; 21: 197-211. ﹝91﹞ Leardini A., Chiari L., Croce U.D., and Cappozzo A., Human movement analysis using sterophotogrammetry, Part 3: Soft tissue artifact assessment and compensation, Gait and Posture 2005; 21: 212-225. ﹝92﹞ Croce U.D., Leardini A., Chiari L., and Cappozzo A., Human movement analysis using sterophotogrammetry, Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics, Gait and Posture 2005; 21: 226-237. ﹝93﹞ Schmidt R., Disselhorst-Klug C., Silny J., and Rau G., A marker-based measurement procedure for unconstrained wrist and elbow motions, Journal of Biomechanics 1999; 32: 615-621. ﹝94﹞ Biryukova E.V., Roby-Brami A., Frolov A.A., and Mokhtari M., Kinematics of human arm reconstructed from spatial tracking system recordings, Journal of Biomechanics 2000; 33: 985-995. ﹝95﹞ Prokopenko R.A., Biryukova E.V., Roby-Brami A., and Frolov A. A., Assement of the accuracy of a human arm model with seven degrees of freedom, Journal of Biomechanics 2001; 34: 177-185. ﹝96﹞ Hingtgen B., McGuire J.R., Wang, M., and Harris G.F., An upper extremity kinematic model for evaluation of hemiparetic stroke, Journal of Biomechanics 2006; 39: 681-688. ﹝97﹞ http://www.vicon.com/ ﹝98﹞ Romilly D.P., Anglin C., Gosine R.G., Hershler C., and Raschke, S.U., A functional task analysis and motion simulation for the development of a powered upper-limb orthosis, IEEE Trans. on Rehabilitation Engineering 1994; 2(3): 119-129. ﹝99﹞ DeLeva P., Adjustments to Zatsiorsky-Seluyanov’s Segment inertia parameters, Journal of Biomechanics 1996; 29(9): 1223-1230. ﹝100﹞ Dumas R., Aissaoui R., and De Guise J. A., A 3D generic inverse dynamic method using wrench notation and quaternion algebra, Computer methods in Biomedical Engineering, 2004; 7(3): 159-166. ﹝101﹞ Lo A. C., Guarino P. D., Richards, L. G., et al., Robot-assisted therapy for long-term upper-limb impairment after stroke, The New England Journal of Medicine 2010; 362: 1772-1783. ﹝102﹞ Peterson M. D., Rhea M. R., Sen A., and Gordon P. M., Resistance exercise for muscular strength in older adults: a meta-analysis, Ageing Research Review 2010; 9: 226-237. ﹝103﹞ Center of Disease Control, QuickStats: Percentage of Adults Aged >=18 Years Who Engaged in Leisure-Time Strengthening Activities at Least Twice a Week,* by Race/Ethnicity and Sex --- National Health Interview Survey, United States, 2009, MMMR Morbidity and Mortality Weekly Report 2011; 60(41): 1429. ﹝104﹞ Center of Disease Control, Trends in strength Training---United States, 1998-2004, MMMR Morbidity and Mortality Weekly Report 2006; 55(28): 770-792. ﹝105﹞ Henmi S., Yonenobu K., and Masatomi T., A biomechanical study of activities of daily living using neck and upper limbs with an optical three-dimensional motion analysis system, Modern rheumatology 2006; 16: 289-293. ﹝106﹞ Chiu L. Z. F. and Salem G. J., Comparison of joint kinetics during free weight and flywheel resistance exercise, Journal of Strength and Conditioning Research 2006; 20(3): 555–562. ﹝107﹞ Soderberg G. L. and Knutson L. M., A guide for use and interpretation of kinesiologic electromyographic data, Physical Therapy 2000; 80(5): 485-498. ﹝108﹞ Karmen G. and Gabriel D. A., Essential of Electromyography, Human Kinetics, Champaign, IL, 2010. ﹝109﹞ Criswell E., Cram’s Introduction to Surface Electromyography, Jones and Bartlett, Sudbury, MA, 2011. ﹝110﹞ Merletti R. and Parker P. A., Electromyography: physiology, engineering, and noninvasive applications, John Wiley and Sons, Hoboken, NJ, 2004. ﹝111﹞ Felici F., Neuromuscular responses to exercise investigated through surface EMG, Journal of Electromyography and kinesiology 2006; 16: 578-585. ﹝112﹞ Hintermeister R. A., Lange G. W., Schultheis J. M., Bey M.J., and Hawkins R. J., Electromyographic activity and applied load during shoulder rehabilitation exercises using elastic resistance, The American Journal of Sports Medicine 1998; 26(2): 210-220. ﹝113﹞ Anderson L. L., Anderson C. H., Mortensen O. S., Poulsen O. M., Bjornlund I. B., and Zebis M. K., Muscle activation and perceived loading during rehabilitation exercises: comparison of dumbbells and elastic resistance, Physical Therapy 2010; 90(4): 538-549. ﹝114﹞ Myers J. B., Pasquale M. R., Laudner K. G., Sell T. C., Bradley J. P., and Lephart S. M., On-the-field resistance-tubing exercises for throwers: An electromyographic analysis, Journal of Atheletic Training 2005; 40(1): 15-22. ﹝115﹞ Gabriel D. A., Karmen G., and Frost G., Neural adaptions to resistive exercise: mechanisms and recommendations for training practices, Sport Medicine 2006; 36(2): 133-149. ﹝116﹞ Lum P. S., Burger C. G., and Shor P. C., Evidence for improved muscle activation patterns after retraining of reaching movements with the MIMI robotic system in subjects with post-stroke hemiparesis, IEEE Transactions on Neural System on Neuro Ssystem and Rehabilitation Engineering 2004; 12(2): 186-256. ﹝117﹞ Hughes A. M., Freeman C. T., Burridge J. H., Chapell P. H., Lewin P. L., and Rogers E., Shoulder and elbow muscle activity during fully supported trajectory tracking in people who have had a stroke, Journal of Electromyography and Kinesilology 2010; 20: 465-476. ﹝118﹞ Kendall F. P., and McCreary E. K., PGP. Muscle: testing and function, 5th ed., Baltimore: Williams & Wilkins; 2005. ﹝119﹞ De Luca C. J., The use of surface electromyography in biomechanics, Journal of Applied Biomechanics 1997; 13: 135-163. ﹝120﹞ Knutson L. M., Soderberg G. L., Ballantyne B. T., and Clarke W. R., A study of various normalization procedures for within day electromyographic data, Journal of Electromyography and kinesiology 1994; 4(1): 47-59. ﹝121﹞ Ekstrom R. A., Soderberg G. L., and Donatelli R. A., Normalization procedures using maximum voluntary isometric contractions for the serratus anterior and trapezius muscles during surface EMG analysis, Journal of Electromyography and kinesiology 2005; 15: 418-428. ﹝122﹞ Miller E. L., Murray L., Richards L., Zorowitz R. D., Bakas T., Clark P., and Bollinger S. A., The comprehensive overview of Nursing and interdisciplinary rehabilitation care of the stroke patients: a scientific statement from the American Heart Association, Stroke 2010; 41: 2402-2448. ﹝123﹞ Department of Veterans Affairs and Department Defense, VA/DoD clinical practice guideline for the management of stroke rehabilitation. Washington, DC: The Office of Quality and Performance, VA & Quality Management Division, United States Army MEDCOM; 2010. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/6548 | - |
dc.description.abstract | 在本論文中,我們提出一種創新的上肢阻力訓練裝置設計,此裝置具有三個肩關節與一肘關節自由度,可依據肌力訓練處方需求,連續性的調整阻力訓練所需的荷重大小,並透過在人體不同活動平面的動作,包括肩關節的外展/內收,肩關節的屈曲/伸展與肘關節的屈曲/伸展,訓練包括三角肌、胸大肌、上斜方肌、棘上肌、肱二頭肌與肱三頭肌等人體上肢主要肌肉群。研究的目的主要是希望能研究開發出一種設計簡潔、容易操作與安全的上肢阻力訓練裝置。適合於年長與慢性疾病醫療健康需求族群,可以在復健或健康照護人員低度參與的情況下,居家進行和緩到溫和程度速度的自主性上肢阻力運動,以維持與強化上肢肌肉群肌力。透過運動學與動力學分析建立自由重量訓練與本阻力訓練裝置數學模型,並以類比於相同人體動作的自由重量訓練的概念,求得阻力訓練裝置各個桿件與彈簧剛性值的設計方程式或準則。依據上述求得的設計方程式與準則,在給定的最大需求荷重規格下,進行了阻力訓練裝置的具體化設計與雛型實驗載台的製作。並透過男女受試者以三個等級的荷重搭配兩種運動速度實際操作啞鈴與阻力訓練裝置,執行肩關節的外展/內收,肩關節的屈曲/伸展與肘關節的屈曲/伸展的動作。運用動作分析方法與肌電值量測,進行肩關節與肘關節扭矩及選定之相關肌肉群的肌肉肌電圖之實驗量測與評估。經由實驗資料的收集與分析,提供測試數據驗證我們以零自由長度彈簧作為阻力訓練裝置阻力源,配合外甲式機構設計之阻力訓練裝置,可以有效減少關節與肌肉在高荷重與速度之啞鈴運動中所承受的慣性矩負面影響的想法,並可提供未來進行相類似裝置設計與驗證時的參考。 | zh_TW |
dc.description.abstract | Regular physical activity reduces the risk of adverse health outcomes for people of all ages. Research has demonstrated that most individuals can benefit from regular physical activity, regardless of whether they participate in vigorous exercise or moderate physical activity. Habitual physical activity and exercise also reduce the risk of chronic disease. For young, healthy people, many aspects of physical fitness can easily be realized by performing exercises that do not require special equipment. Various exercise devices have been developed to enable individuals who require assistance to achieve their physical fitness goals efficiently and consistently. However, concerns have been raised over the possible negative effects and safety of these exercise devices for elderly and clinical populations. Here, an unpowered spring-loaded upper limb exoskeleton designed for strengthening the muscles of the upper limbs at single and multiple joints in different planes is proposed. The upper limb exoskeleton consists of a shoulder joint with three degrees of freedom and an elbow joint with one degree of freedom, and it can perform internal-external, abduction-adduction, and flexion-extension movements of the shoulder, as well as flexion-extension motions of the elbow. Our aim was to provide an upper limb resistance training device that is compact, cost-effective, easy to operate, and safe for elderly and clinical populations who exercise at low and moderate speeds and that can be used for home-based rehabilitation in the absence of a fitness instructor or therapist. Kinematic and dynamic models have been formulated to develop design criteria to analyze free-weight and spring-loaded exoskeletons for upper limb resistance training. Embodiment design was performed and a prototype was constructed for evaluation. Motion analysis methods and electromyography measurements were chosen for evaluation of the joint torques and the neuromuscular response of major upper limb muscles when male and female subjects performed the designated resistance training. The collected data, along with kinematic and dynamic joint torque analysis, not only verifies our hypothesis that, with zero-free-length springs, this spring-loaded upper limb exoskeleton is capable of reducing unfavorable lengthening of the muscles during high-intensity free-weight exercises but also provides important general principles for designing appropriate spring-loaded exoskeletons for upper limb resistance training. | en |
dc.description.provenance | Made available in DSpace on 2021-05-17T09:14:35Z (GMT). No. of bitstreams: 1 ntu-101-D96522028-1.pdf: 3460042 bytes, checksum: 16dba8283a9bc7bd761551d44cd3f1a2 (MD5) Previous issue date: 2012 | en |
dc.description.tableofcontents | 誌謝 i
中文摘要 ii Abstract iii Table of contents iv List of Tables vi List of Figures viii List of Symbols x Chapter 1 Introduction 1 1.1 Background 1 1.2 Related works 6 1.3 Motivation and objectives 21 1.4 Overview of the dissertation 23 Chapter 2 Kinematic and static analysis 28 2.1 Introduction 28 2.2 Kinematic model and joint torque analysis 32 2.3 Preliminary design of the spring-loaded exoskeleton 37 2.4 Embodiment design of the spring-loaded exoskeleton 60 2.5 Summary 65 Chapter 3 Dynamic analysis 66 3.1 Introduction 66 3.2 Dynamic model of upper limb 71 3.3 Dynamic joint torques during free-weight exercise 74 3.4 Dynamic joint torques with the upper limb exoskeleton 75 3.5 Dynamic joint torques during resistance training 78 3.6 Summary 82 Chapter 4 Prototype and preliminary evaluation 84 4.1 The prototype 84 4.2 Experimental design 87 4.3 Results and discussion 94 4.4 Summary 99 Chapter 5 Verification test: A motion analysis study 100 5.1 Introduction 100 5.2 Methods and instrumentation 104 5.3 Results and discussion 115 5.4 Summary 123 Chapter 6 Verification test: An electromyography study 124 6.1 Introduction 124 6.2 Methods and instrumentation 128 6.3 Results and discussion 135 6.4 Summary 144 Chapter 7 Conclusion and future work 145 7.1 Lessons have been learned 147 7.2 Summary of contributions 150 7.3 Recommendations for future work 151 References 153 | |
dc.language.iso | en | |
dc.title | 上肢阻力訓練裝置之設計及評估 | zh_TW |
dc.title | Design and Evaluation of a Spring-loaded Upper Limb Exoskeleton for Resistance Training | en |
dc.type | Thesis | |
dc.date.schoolyear | 100-2 | |
dc.description.degree | 博士 | |
dc.contributor.oralexamcommittee | 蔡穎堅,黃文敏,黃漢邦,劉霆 | |
dc.subject.keyword | 阻力運動,上肢訓練裝置,自由重量訓練,動作分析,肌電圖, | zh_TW |
dc.subject.keyword | resistance exercise,upper limb exoskeleton,free-weight exercise,motion analysis,electromyography, | en |
dc.relation.page | 163 | |
dc.rights.note | 同意授權(全球公開) | |
dc.date.accepted | 2012-08-15 | |
dc.contributor.author-college | 工學院 | zh_TW |
dc.contributor.author-dept | 機械工程學研究所 | zh_TW |
顯示於系所單位: | 機械工程學系 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-101-1.pdf | 3.38 MB | Adobe PDF | 檢視/開啟 |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。