請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/64152
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 陳永耀 | |
dc.contributor.author | Zong-Han Li | en |
dc.contributor.author | 李宗翰 | zh_TW |
dc.date.accessioned | 2021-06-16T17:32:19Z | - |
dc.date.available | 2017-08-17 | |
dc.date.copyright | 2012-08-17 | |
dc.date.issued | 2012 | |
dc.date.submitted | 2012-08-15 | |
dc.identifier.citation | [1] R. Zdero, P. V. Fenton, and J. T. Bryant, 'A digital image analysis method for diagnostic ultrasound calibration,' Ultrasonics, vol. 39, pp. 695-702, 2002.
[2] S. S. Vedam, V. R. Kini, P. J. Keall, V. Ramakrishnan, H. Mostafavi, and R. Mohan, 'Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker,' Medical Physics, vol. 30, pp. 505-513, 2003. [3] R. W. Prager, U. Z. Ijaz, A. H. Gee, and G. M. Treece, 'Three-dimensional ultrasound imaging,' Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 224, pp. 193-223, 2010. [4] N. M. Daher and J. T. Yen, '2-D array for 3-D ultrasound imaging using synthetic aperture techniques,' Ultrasonics, Ferroelectrics and Frequency Control, IEEE Transactions on, vol. 53, pp. 912-924, 2006. [5] P. Sprawls, Physical Principles of Medical Imaging, 1995. [6] W. Robert, H. Bruno, and T. K. E., Electronics for Diagnostic Ultrasound, 2009. [7] B. Haider, 'Power Drive Circuits for Diagnostic Medical Ultrasound,' in Power Semiconductor Devices and IC's, 2006. ISPSD 2006. IEEE International Symposium on, 2006, pp. 1-8. [8] R. W. Prager, R. N. Rohling, A. H. Gee, and L. Berman, 'Rapid calibration for 3-D freehand ultrasound,' Ultrasound in Medicine & Biology, vol. 24, pp. 855-869, 1998. [9] D. G. Wildes, R. Y. Chiao, C. M. W. Daft, K. W. Rigby, L. S. Smith, and K. E. Thomenius, 'Elevation performance of 1.25D and 1.5D transducer arrays,' Ultrasonics, Ferroelectrics and Frequency Control, IEEE Transactions on, vol. 44, pp. 1027-1037, 1997. [10] B. A. J. Angelsen, H. Torp, S. Holm, K. Kristoffersen, and T. A. Whittingham, 'Which transducer array is best?,' European Journal of Ultrasound, vol. 2, pp. 151-164, 1995. [11] C. M. W. Daft, D. G. Wildes, L. J. Thomas, L. S. Smith, R. S. Lewandowski, W. M. Leue, K. W. Rigby, C. L. Chalek, and W. T. Hatfield, 'A 1.5D transducer for medical ultrasound,' in Ultrasonics Symposium, 1994. Proceedings., 1994 IEEE, 1994, pp. 1491-1495 vol.3. [12] P. Abolmaesumi, S. E. Salcudean, Z. Wen-Hong, M. R. Sirouspour, and S. P. DiMaio, 'Image-guided control of a robot for medical ultrasound,' Robotics and Automation, IEEE Transactions on, vol. 18, pp. 11-23, 2002. [13] 3D Guidance trakSTAR (Ascension Technology Corporation) http://www.ascension-tech.com/medical/trakSTAR.php. [14] P.W. Hsu, R. W. Prager, A. H. Gee, and G. M. Treece, 'Real-Time Freehand 3D Ultrasound Calibration,' Ultrasound in Medicine & Biology, vol. 34, pp. 239-251, 2008. [15] S. Meairs, J. Beyer, and M. Hennerici, 'Reconstruction and visualization of irregularly sampled three- and four-dimensional ultrasound data for cerebrovascular applications,' Ultrasound in Medicine & Biology, vol. 26, pp. 263-272, 2000. [16] N. Pagoulatos, D. R. Haynor, and Y. Kim, 'A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer,' Ultrasound in Medicine & Biology, vol. 27, pp. 1219-1229, 2001. [17] Matrox Morphis (Matrox Electronic Systems Ltd.) http://www.matrox.com/imaging/en/products/frame_grabbers/morphis/. [18] N. OTSU, 'A Threshold Selection Method from Gray-Level Histograms,' Systems, Man and Cybernetics, IEEE Transactions on, vol. 9, pp. 62-66, 1979. [19] A. Goldstein, 'Errors in ultrasound digital image distance measurements,' Ultrasound in Medicine & Biology, vol. 26, pp. 1125-1132, 2000. [20] Y.-C. Chen, 'Motion Estimation by Respiratory Surrogated Signals of Liver Tumor Tracking,' Master Thesis, Nation Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics College of Electrical Engineering and Computer Science, 2011. [21] T. K. Chen, A. D. Thurston, R. E. Ellis, and P. Abolmaesumi, 'A Real-Time Freehand Ultrasound Calibration System with Automatic Accuracy Feedback and Control,' Ultrasound in Medicine & Biology, vol. 35, pp. 79-93, 2009. [22] O. V. Solberg, F. Lindseth, H. Torp, R. E. Blake, and T. A. Nagelhus Hernes, 'Freehand 3D Ultrasound Reconstruction Algorithms—A Review,' Ultrasound in Medicine & Biology, vol. 33, pp. 991-1009, 2007. [23] L. Mercier, T. Lango, F. Lindseth, and L. D. Collins, 'A review of calibration techniques for freehand 3-D ultrasound systems,' Ultrasound in Medicine & Biology, vol. 31, pp. 143-165, 2005. [24] D. A. Kuban, L. Dong, R. Cheung, E. Strom, and R. De Crevoisier, 'Ultrasound-Based Localization,' Seminars in Radiation Oncology, vol. 15, pp. 180-191, 2005. [25] G. M. Treece, A. H. Gee, R. W. Prager, C. J. C. Cash, and L. H. Berman, 'High-definition freehand 3-D ultrasound,' Ultrasound in Medicine & Biology, vol. 29, pp. 529-546, 2003. [26] R. N. Rohling, A. H. Gee, and L. Berman, 'Automatic registration of 3-D ultrasound images,' Ultrasound in Medicine & Biology, vol. 24, pp. 841-854, 1998. [27] T. R. Gururaja and R. K. Panda, 'Current status and future trends in ultrasonic transducers for medical imaging applications,' in Applications of Ferroelectrics, 1998. ISAF 98. Proceedings of the Eleventh IEEE International Symposium on, 1998, pp. 223-228. [28] A. Goldstein and B. L. Madrazo, 'Slice-thickness artifacts in gray-scale ultrasound,' Journal of Clinical Ultrasound, vol. 9, pp. 365-375, 1981. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/64152 | - |
dc.description.abstract | 超音波影像為目前常用之醫療檢測儀器,它具有即時成像、無放射線傷害且成本低等優點。超音波影像可檢視身體內部結構,其成像原理為量測聲波發送至物體反射之時間差與強度,形成二維灰階影像。若在超音波探頭上裝設位置感測器,將可了解超音波影像所掃描的切面位置,進而推測出影像中物體在空間中位置,此稱為超音波影像定位。但超音波影像只能提供兩維度之資訊,若想利用一張超音波影像定位出物體在空間三維位置是非常困難的。本論文提出一創新之方法,利用兩相互正交之探頭,得到一組正交超音波影像,若物體在兩影像重疊之區域將可結合兩影像之位置資訊,得到準確之三維定位點。本研究將設計兩種不同類型之實驗,依照被掃描物之特性可區分為靜態定位實驗與動態定位實驗;在靜態定位實驗中將驗證使用雙超音波影像定位可提升定位準確度,靜態定位誤差皆小於1 mm;在動態定位實驗中將模擬肝臟移動軌跡作為標的,動態追蹤定位誤差皆小於1.8 mm。 | zh_TW |
dc.description.abstract | The ultrasound image is the common medical diagnostic equipment with a lot of advantages including real time imaging, low cost and nonradioactive. The theorem of ultrasound imaging is that a transducer receives the sound wave reflected from the target. The ultrasound system estimates the distance according to the information of reflected sound waves. Then, the system presents the distance information using a two dimension image. The ultrasound image can show the structure of human body, and it could be combined with position sensors, which are attached to an ultrasound probe, to find the target position. This positioning approach is called ultrasound image positioning. Positioning using single ultrasound image cannot be accurate since the thickness problem. In this thesis, a novel ultrasound positioning approach is proposed. This research used two ultrasound systems that are placed orthogonally. The proposed system can obtain an accurate target position using dual ultrasound images. For fixed target, the positioning error was less than 1 mm. For moving target, the positioning error was less than 1.8 mm. | en |
dc.description.provenance | Made available in DSpace on 2021-06-16T17:32:19Z (GMT). No. of bitstreams: 1 ntu-101-R99945027-1.pdf: 4573637 bytes, checksum: da957b5a535ae4116642ee63c4a9dcd8 (MD5) Previous issue date: 2012 | en |
dc.description.tableofcontents | 誌謝 i
摘要 ii Abstract iii Contents iv List of Figures viii List of Tables xiii Chapter 1 Introduction 1 1.1 Background 1 1.2 Motivation 3 1.3 Proposed Approach 6 1.4 Thesis Overview 8 Chapter 2 The Characteristic of Ultrasound Image 9 2.1 Ultrasound Imaging Principles 10 2.2 Ultrasound Beam Thickness Problem 12 2.3 Multi-row Arrays Transducer 13 2.4 Summary 16 Chapter 3 Ultrasound Image Positioning using Dual Ultrasound Systems 17 3.1 Design of Scanner with Dual Ultrasound Probes 20 3.2 Coordinates System 22 3.2.1 Measurement and Sensing System 23 3.3 Coordinate Transformation 25 3.4 Detection of Target in Ultrasound Images 30 3.4.1 Frame Grabber 30 3.4.2 The Highest Gray Level Point 31 3.4.3 Otsu’s Method 34 3.5 Image Pixelation Errors 37 3.6 Transformation Compensation 40 3.7 Summary 42 Chapter 4 Dual Ultrasound Images Positioning Experiment and Results 44 4.1 Positioning by Dual Ultrasound Images for Fixed Target 47 4.1.1 Experimental Setup 47 4.1.2 Target Location of the Ultrasound Image Slice Thickness 49 4.1.3 Consideration to the Target Size 51 4.1.4 Consideration to the Target Shape 53 4.2 Positioning by Dual Ultrasound Images for Simulative Motion Trajectory 56 4.2.1 Experimental Setup 57 4.2.2 Target Motion Trajectory 58 4.2.3 Sensor on the Scanner 60 4.2.4 Target Detection in Region of Interest of Ultrasound Image 61 4.2.5 Target Motion Trajectory of Estimation 66 4.3 Positioning by Dual Ultrasound Images for Pig Liver Motion Trajectory 73 4.3.1 Pig Liver Motion Trajectory 73 4.3.2 Target Detection in Region of Interest of Ultrasound Image 75 4.3.3 Target Motion Trajectory of Estimation 77 4.4 Summary 82 Chapter 5 Conclusions and Future Work 83 Appendix 84 References 89 | |
dc.language.iso | en | |
dc.title | 二維超音波影像定位的厚度解析度之改善 | zh_TW |
dc.title | Improvement on the Thickness-direction Resolution of 2D Ultrasound Image Positioning | en |
dc.type | Thesis | |
dc.date.schoolyear | 100-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 顏家鈺,連豊力,何明志,林文澧 | |
dc.subject.keyword | 超音波影像定位,座標轉換,特徵點追蹤, | zh_TW |
dc.subject.keyword | Positioning by ultrasound image,Coordinate transformation,Feature tracking, | en |
dc.relation.page | 93 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2012-08-15 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 生醫電子與資訊學研究所 | zh_TW |
顯示於系所單位: | 生醫電子與資訊學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-101-1.pdf 目前未授權公開取用 | 4.47 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。