請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/60663完整後設資料紀錄
| DC 欄位 | 值 | 語言 |
|---|---|---|
| dc.contributor.advisor | 張瑞峰(Ruey-Feng Chang) | |
| dc.contributor.author | Chao-Shuan Lee | en |
| dc.contributor.author | 李兆軒 | zh_TW |
| dc.date.accessioned | 2021-06-16T10:25:12Z | - |
| dc.date.available | 2018-08-20 | |
| dc.date.copyright | 2013-08-20 | |
| dc.date.issued | 2013 | |
| dc.date.submitted | 2013-08-15 | |
| dc.identifier.citation | References
[1] R. Siegel, D. Naishadham, and A. Jemal, 'Cancer statistics, 2013,' CA: a cancer journal for clinicians, vol. 63, pp. 11-30, 2013. [2] N. Howlader, A. Noone, M. Krapcho, N. Neyman, R. Aminou, W. Waldron, S. Altekruse, C. Kosary, J. Ruhl, and Z. Tatalovich, 'SEER Cancer Statistics Review, 1975–2008. Bethesda, MD: National Cancer Institute; 2011,' Also available online. Last accessed December, vol. 1, 2011. [3] E. A. Sickles, R. Filly, and P. Callen, 'Benign breast lesions: ultrasound detection and diagnosis,' Radiology, vol. 151, pp. 467-470, 1984. [4] T. M. Kolb, J. Lichy, and J. H. Newhouse, 'Comparison of the performance of screening mammography, physical examination, and breast us and evaluation of factors that influence them: an analysis of 27,825 patient evaluations1,' Radiology, vol. 225, pp. 165-175, 2002. [5] T. E. Wilson, M. A. Helvie, and D. A. August, 'Breast cancer in the elderly patient: early detection with mammography,' Radiology, vol. 190, pp. 203-207, 1994. [6] M. A. Roubidoux, M. A. Helvie, N. E. Lai, and C. Paramagul, 'Bilateral breast cancer: early detection with mammography,' Radiology, vol. 196, pp. 427-431, 1995. [7] S. Buseman, J. Mouchawar, N. Calonge, and T. Byers, 'Mammography screening matters for young women with breast carcinoma,' Cancer, vol. 97, pp. 352-358, 2003. [8] P. Skaane, 'Ultrasonography as adjunct to mammography in the evaluation of breast tumors,' Acta radiologica. Supplementum, vol. 420, p. 1, 1999. [9] K. M. Kelly, J. Dean, S.-J. Lee, and W. S. Comulada, 'Breast cancer detection: radiologists’ performance using mammography with and without automated whole-breast ultrasound,' European radiology, vol. 20, pp. 2557-2564, 2010. [10] P. Crystal, S. D. Strano, S. Shcharynski, and M. J. Koretz, 'Using sonography to screen women with mammographically dense breasts,' American Journal of Roentgenology, vol. 181, pp. 177-182, 2003. [11] N. F. Boyd, G. S. Dite, J. Stone, A. Gunasekara, D. R. English, M. R. McCredie, G. G. Giles, D. Tritchler, A. Chiarelli, and M. J. Yaffe, 'Heritability of mammographic density, a risk factor for breast cancer,' New England Journal of Medicine, vol. 347, pp. 886-894, 2002. [12] K. M. Kelly, J. Dean, W. S. Comulada, and S.-J. Lee, 'Breast cancer detection using automated whole breast ultrasound and mammography in radiographically dense breasts,' European radiology, vol. 20, pp. 734-742, 2010. [13] W. A. Berg, L. Gutierrez, M. S. NessAiver, W. B. Carter, M. Bhargavan, R. S. Lewis, and O. B. Ioffe, 'Diagnostic Accuracy of Mammography, Clinical Examination, US, and MR Imaging in Preoperative Assessment of Breast Cancer1,' Radiology, vol. 233, pp. 830-849, 2004. [14] M. L. Giger, 'Computer-aided diagnosis of breast lesions in medical images,' Computing in Science & Engineering, vol. 2, pp. 39-45, 2000. [15] K. Flobbe, P. Nelemans, A. Kessels, G. Beets, M. Von Meyenfeldt, and J. Van Engelshoven, 'The role of ultrasonography as an adjunct to mammography in the detection of breast cancer: a systematic review,' European Journal of Cancer, vol. 38, pp. 1044-1050, 2002. [16] J. H. Lee, Y. K. Jeong, K. B. Park, J. K. Park, A. K. Jeong, and J. C. Hwang, 'Operator-dependent techniques for graded compression sonography to detect the appendix and diagnose acute appendicitis,' American Journal of Roentgenology, vol. 184, pp. 91-97, 2005. [17] Y. Ikedo, D. Fukuoka, T. Hara, H. Fujita, E. Takada, T. Endo, and T. Morita, 'Development of a fully automatic scheme for detection of masses in whole breast ultrasound images,' Med Phys, vol. 34, pp. 4378-88, Nov 2007. [18] R. F. Chang, K. C. Chang-Chien, E. Takada, C. S. Huang, Y. H. Chou, C. M. Kuo, and J. H. Chen, 'Rapid image stitching and computer-aided detection for multipass automated breast ultrasound,' Med Phys, vol. 37, pp. 2063-73, May 2010. [19] W. K. Moon, Y. W. Shen, M. S. Bae, C. S. Huang, J. H. Chen, and R. F. Chang, 'Computer-aided tumor detection based on multi-scale blob detection algorithm in automated breast ultrasound images,' IEEE Trans Med Imaging, vol. 32, pp. 1191-200, Jul 2013. [20] M. C. Yang, C. S. Huang, J. H. Chen, and R. F. Chang, 'Whole breast lesion detection using naive bayes classifier for portable ultrasound,' Ultrasound Med Biol, vol. 38, pp. 1870-80, Nov 2012. [21] F. H. Raab, E. B. Blood, T. O. Steiner, and H. R. Jones, 'Magnetic position and orientation tracking system,' Aerospace and Electronic Systems, IEEE Transactions on, pp. 709-718, 1979. [22] E. Paperno, I. Sasada, and E. Leonovich, 'A new method for magnetic position and orientation tracking,' Ieee Transactions on Magnetics, vol. 37, pp. 1938-1940, Jul 2001. [23] M. Nakamoto, K. Nakada, Y. Sato, K. Konishi, M. Hashizume, and S. Tamura, 'Intraoperative magnetic tracker calibration using a magneto-optic hybrid tracker for 3-D ultrasound-based navigation in laparoscopic surgery,' Ieee Transactions on Medical Imaging, vol. 27, pp. 255-270, Feb 2008. [24] S. Nakano, M. Yoshida, K. Fujii, K. Yorozuya, Y. Mouri, J. Kousaka, T. Fukutomi, J. Kimura, T. Ishiguchi, and K. Ohno, 'Fusion of MRI and sonography image for breast cancer evaluation using real-time virtual sonography with magnetic navigation: first experience,' Japanese journal of clinical oncology, vol. 39, pp. 552-559, 2009. [25] S. Nakano, K. Yorozuya, M. Takasugi, Y. Mouri, T. Fukutomi, O. Arai, and T. Mitake, 'Detection of enhancing lesions on contrast-enhanced MRI of the breast using real-time virtual sonography: fusion of MRI and sonography data,' in BREAST CANCER RESEARCH AND TREATMENT, 2007, pp. S13-S13. [26] F. Tatsugami, M. Matsuki, G. Nakai, M. Tanikake, S. Yoshikawa, I. Narabayashi, K. Miyaji, A. Asai, S. Fujiwara, and Y. Hongo, 'Hepatic Computed Tomography for Simultaneous Depiction of Hepatocellular Carcinoma, Intrahepatic Portal Veins, and Hepatic Veins in Real-time Virtual Sonography Initial Experience,' Journal of ultrasound in medicine, vol. 26, pp. 1065-1069, 2007. [27] S. Yamamoto, N. Maeda, M. Tamesa, Y. Nagashima, K. Suga, and M. Oka, 'Sentinel Lymph Node Detection in Breast Cancer Patients by Real‐Time Virtual Sonography Constructed With Three‐Dimensional Computed Tomography‐Lymphography,' The Breast Journal, vol. 16, pp. 4-8, 2010. [28] S. Nakano, M. Yoshida, K. Fujii, K. Yorozuya, J. Kousaka, Y. Mouri, T. Fukutomi, Y. Ohshima, J. Kimura, and T. Ishiguchi, 'Real-time virtual sonography, a coordinated sonography and MRI system that uses magnetic navigation, improves the sonographic identification of enhancing lesions on breast MRI,' Ultrasound in medicine & biology, vol. 38, pp. 42-49, 2012. [29] D. M. Tullsen, S. J. Eggers, and H. M. Levy, 'Simultaneous multithreading: Maximizing on-chip parallelism,' in ACM SIGARCH Computer Architecture News, 1995, pp. 392-403. [30] J. Diebel, 'Representing attitude: Euler angles, unit quaternions, and rotation vectors,' Matrix, 2006. [31] M. M. Deza and E. Deza, Encyclopedia of distances: Springer, 2009. [32] J. C. Gower, 'Euclidean distance geometry,' Mathematical Scientist, vol. 7, pp. 1-14, 1982. [33] P. D. DARBRE, 'Recorded quadrant incidence of female breast cancer in Great Britain suggests a disproportionate increase in the upper outer quadrant of the breast,' Anticancer research, vol. 25, pp. 2543-2550, 2005. | |
| dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/60663 | - |
| dc.description.abstract | 過去的超音波檢驗中,放射師如果發現了疑似腫瘤的組織,會用人工的方式去標記組織的方向跟距離,但這並不準確。這篇文章中介紹的是全乳房超音波磁波定位及影像儲存系統。這套系統利用磁波定位器 (magnetic tracker) 來取得超音波探頭的位置和方向,也使用螢幕擷取工具來取得超音波機器的螢幕影像。在系統運作的過程中,分成兩部分:第一部分是定位乳頭的位置及乳房的區域大小。第二部分是記錄整個超音波檢驗的過程,以及將探頭的資訊顯示在使用者介面上。藉由上面的流程,系統可以提供更準確地探頭資訊,以及清楚記錄檢驗的過程。所以,醫生可以利用系統提供的這些探頭資訊及記錄來提供更正確的診斷。模擬的結果顯示所有系統測量出來的距離跟真實情況的差異都小於0.1公分。而在真實的實驗中,我們測量出來的探頭資訊跟操作者標記的探頭資訊,他們的平均差異是0.61公分。綜合以上的結果,顯示這套系統具有準確性及有效提供更多資訊給醫生做診斷。 | zh_TW |
| dc.description.abstract | In past ultrasound examination, when the suspected lesion was found, the distance and the clock direction will be measured by a radiologist artificially. In this study, the whole breast ultrasound (US) with magnetic tracker and image storing system is proposed. The proposed system uses the magnetic tracker to get position and clock direction of the probe. More, the system uses the screen capture tool to get the screen of ultrasound machine. The system consists of two phases. First, the operator marks the nipple position and the breast 12 o’clock boundary. Next, our system can track the probe at the whole examination time and show the probe information in the user interface panel. Consequently, the system provides more precise position information about the probe and stores the progress of ultrasound examination. A physician can review the recorded US images with probe location to find the abnormalities conveniently. According to the simulation result, all the distance difference between the proposed system and ground truth are smaller than 0.1 cm. The experimental result shows the average probe’s position differences of the system and the operator is less than 0.61 (cm). In summary, the simulation and experimental results demonstrate the high efficiency and accuracy of the proposed system. | en |
| dc.description.provenance | Made available in DSpace on 2021-06-16T10:25:12Z (GMT). No. of bitstreams: 1 ntu-102-R00922076-1.pdf: 1963129 bytes, checksum: ec52235872ed8ea8ff525eddf7866295 (MD5) Previous issue date: 2013 | en |
| dc.description.tableofcontents | 口試委員審定書 i
致謝 ii 摘要 iii Abstract iv Table of Contents v List of Figures vi List of Tables vii Chapter 1 Introduction 1 Chapter 2 Materials 5 2.1 Patient characteristics 5 2.2 Magnetic tracking system 5 Chapter3 Proposed Method 8 3.1 Tracking Device 9 3.1.1 Position and Orientation 10 3.1.2 Position adjustment 12 3.2 Breast region of interest (BROI) localization 13 3.2.1 BROI initialization 14 3.2.2 Position extraction and calculation of a moving probe 16 3.3 Probe tracking (probe trajectory/ frozen image) 18 Chapter 4 Results and Discussion 21 4.1 Simulation mechanism 21 4.2 Simulation result 23 4.3 Experimental comparison between proposed system and the operator 26 4.4 Discussion 33 Chapter 5 Conclusion and Future Work 35 References 37 | |
| dc.language.iso | en | |
| dc.subject | 超音波探頭位置 | zh_TW |
| dc.subject | 磁波定位器 | zh_TW |
| dc.subject | 超音波檢驗 | zh_TW |
| dc.subject | ultrasound probe position | en |
| dc.subject | magnetic tracker | en |
| dc.subject | ultrasound examination | en |
| dc.title | 全乳房超音波磁波定位及影像儲存系統 | zh_TW |
| dc.title | Whole Breast Ultrasound with Magnetic Field Transmitter and Image Storing System | en |
| dc.type | Thesis | |
| dc.date.schoolyear | 101-2 | |
| dc.description.degree | 碩士 | |
| dc.contributor.oralexamcommittee | 黃俊升,張允中 | |
| dc.subject.keyword | 超音波探頭位置,磁波定位器,超音波檢驗, | zh_TW |
| dc.subject.keyword | ultrasound probe position,magnetic tracker,ultrasound examination, | en |
| dc.relation.page | 39 | |
| dc.rights.note | 有償授權 | |
| dc.date.accepted | 2013-08-15 | |
| dc.contributor.author-college | 電機資訊學院 | zh_TW |
| dc.contributor.author-dept | 資訊工程學研究所 | zh_TW |
| 顯示於系所單位: | 資訊工程學系 | |
文件中的檔案:
| 檔案 | 大小 | 格式 | |
|---|---|---|---|
| ntu-102-1.pdf 未授權公開取用 | 1.92 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。
