請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/55498
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 鍾立來 | |
dc.contributor.author | Ting-Yu Chang | en |
dc.contributor.author | 張庭瑜 | zh_TW |
dc.date.accessioned | 2021-06-16T04:05:51Z | - |
dc.date.available | 2015-08-16 | |
dc.date.copyright | 2015-08-16 | |
dc.date.issued | 2015 | |
dc.date.submitted | 2015-08-06 | |
dc.identifier.citation | [1] 西山拓、小野正行,「開口周比0.4 以上の開口壁に関する実験的研究-(その2)面積膨張、水平耐力」,日本建築学会大会学術講演梗概集C-2, 構造IV, pp.149-150, 1995.
[2] 黃世建、陳力平、陳俊宏,「含開口RC 牆非韌性構架之耐震行為研究」,國家地震工程研究中心,NCREE-03-010,台北,2003年。 [3] , ,“An Experimental Study on Reinforced Concrete Partially Infilled Frames,” Engineering Structures, Vol. 29, pp. 449-460, 2007. [4] 吳炳昀,「低矮型鋼筋混凝土牆之鋼筋配置暨補強研究」,國立台灣大學結構工程研究所碩士論文,黃世建教授指導,台北,2012年。 [5] 楊欽富,「含邊界柱開口鋼筋混凝土剪力牆之耐震行為」,國立成功大學建築研究所碩士論文,許茂雄教授指導,台南,1991年。 [6] 李曉盈,「後置式化學錨栓於低強度混凝土中之錨定行為」,國立台灣大學結構工程研究所碩士論文,黃世建教授指導,台北,2013年。 [7] 蕭輔沛、鍾立來、葉勇凱、簡文郁、沈文成、邱聰智、周德光、趙宜峰、翁樸文、楊耀昇、禇有倫、涂耀賢、柴駿甫、黃世建,「校舍結構耐震評估與補強技術手冊(第三版)」,國家地震工程研究中心,NCREE-13-023,台北,2013年。 [8] 內政部營建署,「結構混凝土施工規範」,台北,2011年。 [9] 楊季軒,「間接接合型鋼框架斜撐在鋼筋混凝土構架耐震補強之應用」,國立台灣大學結構工程所碩士論文,黃世建教授指導,台北,2014年。 [10] 內政部營建署,「建築物基礎構造設計規範」,台北,2011年。 [11] 內政部營建署,「混凝土結構設計規範」,台北,2011年。 [12] 邱聰智、邱建國、葉勇凱、簡文郁、鍾立來、周德光,「典型校舍耐震補強設計與驗證」,國家地震工程研究中心, NCREE-08-038,台北,2008年。 [13] 杜昱石,「低矮鋼筋混凝土街屋典型開口外牆之耐震行為研究」,國立台灣科技大學營建工程所碩士論文,歐昱辰教授指導,台北,2014年。 [14] ACI Committee 318, “Building Code Requirement for Structural Concrete (318-11) and Commentary (ACI 318-11R),” American Concrete Institute, Farmington Hill, Michigan, 2001. [15] 倍握實貿易有限公司,「Powers技術手冊」,2011年。 [16] 許元馨,「不同開口形式加強磚造磚牆面內側向加載試驗」,國立成功大學建築學系研究所碩士論文,杜怡萱教授指導,台南,2015年。 [17] ACI Committee 374, “ACI 371.1-05:Accptance Criteria for Moment Frames Based on Structural Testing and Commentary,” American Concrete Institute, Farmington Hill, Michigan, 9 pp, 2006. [18] 鍾立來、吳賴雲、林琨偉、楊耀昇、連冠華,「以現地試驗檢核校舍結構耐震能力之初步評估」,中國土木水利工程學刊第二十四卷第三期,第299~311頁,2012年。 [19] 涂耀賢、周逢霖、邱聰智,「開口RC牆構架載重位移曲線預測研究」,中國土木水利工程學刊第二十七卷第一期,第37~46頁,2015年。 [20] Elwood, K.J. and Moehle, J.P., “Axial Capacity Model for Shear-Damaged Columns,” ACI Structural Journal, Vol. 102, No. 4, pp. 578-587, 2005. [21] Elwood, K.J. and Moehle, J.P., “Drift Capacity of Reinforced Concrete Columns with Light Transverse Reinforcement,” Earthquake Spectra, Vol. 21, No. 1, pp. 71-89, 2005. [22] 涂耀賢,「低矮型RC 牆暨構架之側向載重位移曲線預測研究」,國立台灣科技大學營建工程研究所博士論文,黃世建教授指導,2005年。 [23] American Society of Civil Engineers (ASCE), “Seismic Rehabilitation of Existing Buildings,” Report No. ASCE/SEI 41-06, Virginia, USA, 2007. [24] Sozen, M. A., Monteiro, P., Moehle, J. P., and Tang, H. T., “Effects of cracking and age on stiffness reinforced concrete walls resisting in-plane shear,” Proc., The Fourth Symposium on Nuclear Power Plant Structures, Equipment, and Piping, North Carolina State Univ., Raleigh, NC, Dec., 3.1-3.13, 1992. [25] Paulay, T., and Priestley, M. J. N., “Seismic Design of Reinforced Concrete and Masonry Buildings,” John Wiley & Sons, Inc., New York, 744 pp, 1992. [26] 李宏仁、黃世建,「鋼筋混凝土不連續區域之剪力強度評估-軟化壓拉桿模型簡算法之實例應用」,結構工程學會,結構工程第十七卷第四期,第53~70頁,2002年。 [27] 國家地震工程研究中心,「植筋參考圖說」,校舍結構耐震補強工程參考圖說,台北,2011年。 [28] 涂耀賢、周逢霖、江文卿,「鋼筋混凝土低型剪力牆幾何性質對剪力強度之影響」,中國土木水利工程學刊第二十二卷第一期,第99~111頁,2010年。 | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/55498 | - |
dc.description.abstract | 民國88 年發生的912 地震反應出國中小校舍耐震能力普遍不足之問題,各方學者對此亦提出對應之補強工法,其中,剪力牆補強為一常見的補強方法。惟有鑒於剪力牆補強之後,雖可大幅提升結構耐震性質,但難以滿足既有校舍對於通風及採光之需求,有鑑於此,本研究參考台南市後甲國中德育樓之結構配置,規劃一系列開口剪力牆補強試體進行試驗研究,以探討開門或開窗的剪力牆補強試體之耐震行。
為了能符合目前現有的校舍型式,本次試驗分別以柱間淨跨度300 公分及420公分兩種校舍常見的構架尺度,共規劃了八組試體進行試驗,其中包含兩組空構架試體以及六組開口剪力牆補強試體,於國家地震工程研究中心實驗室進行反覆側推試驗。本試驗所規劃的開口剪力牆補強試體,為考量校舍建築的實際使用情形,以採光通風佳的大面積開口為原則,此外試體開口位置皆為對稱配置,以利未來能建立一套有效且可靠的開口RC 牆補強耐震評估方式及補強施工準則給工程師參考使用。 實驗結果顯示,大開口RC 牆補強試體,可提昇約3.8 倍的側向強度、提昇至少13 倍的勁度;小開口RC 牆補強試體,可提昇約6.8 倍的側向強度、提昇至少34 倍的勁度。且於試體喪失垂直乘載能力之前測試層間變位角均可達2 %,表示開口鋼筋混凝土牆補強可直接應用在校舍等低矮型建築物上。而以校舍手冊三版所建議的評估方法為主軸,再加以修改過後的評估曲線均能保守的評估試驗結果。 | zh_TW |
dc.description.abstract | Lots of elementary and secondary school buildings were damaged by the devastating 921 Chi-Chi earthquake, so scholars proposed methods for increasing the seismic performance of school buildings. Adding shear wall method is a common method to be used in school buildings retrofit. However, by the use of retrofit of adding shear wall, it is difficult to satisfy the lighting and ventilation requirements for school building. Consequently, National Center for Research on Earthquake Engineering (NCREE) planned a series of specimens retrofitted by RC walls with window and door opening to study the feasibility of the proposed method. The specimens were designed according to existing school buildings.
In order to comply with existing schools buildings, two common spans, 300 cm and 420 cm, were considered in the experimental plan. This experiment includes eight specimens, which are two bare-frame specimens and six retrofitted specimens. Considering the lighting and ventilation of school buildings, large opening is main principle. Also, the specimen was designed in symmetric configuration, in order to facilitate and establish an effective and reliable seismic evaluation method of RC walls with openings for engineers in the future. Experimental results show that the large-opening specimens can enhance about 3.8 times of lateral strength, at least 13 times of stiffness; the small-opening specimens can enhance about 6.8 times of lateral strength, at least 34 times of stiffness. Drift ratio of all specimens can be up to 2%, it means that the retrofit by RC wall with opening can be applied directly to the low-rise school buildings. The force-displacement curves of all specimens are predicted base on the third-edition Evaluation and Retrofit Handbook for School Buildings. All prediction results are conservative after modification. | en |
dc.description.provenance | Made available in DSpace on 2021-06-16T04:05:51Z (GMT). No. of bitstreams: 1 ntu-104-R02521239-1.pdf: 46218785 bytes, checksum: 1754db0e2dd650ab25f583f87457700e (MD5) Previous issue date: 2015 | en |
dc.description.tableofcontents | 口試委員審定書 I
誌謝 II 摘要 IV ABSTRACT V 目錄 VI 表目錄 XI 圖目錄 XVI 照片目錄 XXVI 第一章 緒論 1 1.1 研究動機與目的 1 1.2文獻回顧 3 1.3 研究方法與內容 5 第二章 試驗規劃與試體製作 7 2.1 前言 7 2.2 構架之設計 7 2.2.1 基礎 8 2.2.2 柱 8 2.2.3 梁 9 2.3 開口剪力牆補強試體 9 2.3.1 開口尺寸設計 10 2.3.2 植筋設計 11 2.3.3 角隅鋼筋設計 12 2.3.4 水平向拉力鋼筋設計 13 2.4 試體製作 13 2.4.1 鋼筋混凝土構架製作 13 2.4.2 開口剪力牆補強施作 17 第三章 試驗佈置與試驗程序 21 3.1 前言 21 3.2 測試佈置 21 3.2.1 固定系統 21 3.2.2 施力系統 22 3.2.3 測試佈置組裝 23 3.3 量測系統佈置 24 3.3.1 內部量測系統 24 3.3.2 外部量測系統 25 3.4 測試步驟 26 第四章 試驗觀察與討論 28 4.1 前言 28 4.2 短跨試體試驗觀察 29 4.2.1 試體FS 29 4.2.2 試體FSW-19 30 4.2.3 試體FSD-19 32 4.3 長跨試體試驗觀察 35 4.3.1 試體FL 35 4.3.2 試體FLW-31 36 4.3.3 試體FLD-31 39 4.3.4 試體FLW-19 42 4.3.5 試體FLD-11 45 4.4 綜合比較 47 4.4.1 跨度 47 4.4.2 增設水平拉力鋼筋 48 4.4.3 植筋差異 49 4.4.4 開口大小 50 第五章 試驗結果與討論 51 5.1 前言 51 5.2 材料試驗 51 5.2.1 混凝土抗壓試驗 52 5.2.2 鋼筋拉拔試驗 52 5.3 短跨試體試驗討論 53 5.3.1 試體FS 53 5.3.2 試體FSW-19 54 5.3.3 試體FSD-19 56 5.4 長跨試體試驗討論 58 5.4.1 試體FL 58 5.4.2試體FLW-31 59 5.4.3 試體FLD-31 61 5.4.4試體FLW-19 63 5.4.5 試體FLD-11 64 5.5 綜合討論 66 5.5.1 各試體強度比較 67 5.5.2 完美彈塑性比較 68 第六章 試體分析與評估 72 6.1 前言 72 6.2 分析方法 72 6.2.1 手冊三版方法 72 6.2.2 ACI 318-11公式方法 82 6.3 評估曲線 83 6.3.1 空構架評估曲線 83 6.3.2 補強試體評估曲線 84 6.3.3 綜合討論 86 6.4 改良評估曲線 87 6.4.1 改良方法 87 6.4.2 改良評估結果 88 第七章 結論與建議 92 7.1 結論 92 7.1.1 大開口試體 92 7.1.2 小開口試體 93 7.1.3 植筋拉拔試驗 94 7.1.4 評估曲線 94 7.2 建議 95 參考文獻 96 附錄A 植筋拉拔試驗 334 A.1 前言 334 A.2 試驗規劃及測試佈置 334 A.3 植筋拉拔試驗結果 336 A.4 試驗結果討論 337 附錄B 頻道對照表及外部量測結果呈現 355 附錄C 評估曲線計算 398 C-1 空構架FS單柱評估曲線計算 398 C.2 補強試體FSW-19曲線單側元素塊評估曲線計算 400 C.2.1 手冊三版方法計算 400 C.2.2 ACI公式方法計算 406 | |
dc.language.iso | zh-TW | |
dc.title | 鋼筋混凝土開口剪力牆校舍補強之試驗研究 | zh_TW |
dc.title | Experimental Study on Retrofit of School Building by
Adding Reinforced Concrete Shear Wall with Opening | en |
dc.type | Thesis | |
dc.date.schoolyear | 102-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 楊耀昇,涂耀賢,鄭全桓 | |
dc.subject.keyword | 校舍,RC 開口剪力牆,補強, | zh_TW |
dc.subject.keyword | school buildings,RC wall with openings,retrofit, | en |
dc.relation.page | 406 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2015-08-06 | |
dc.contributor.author-college | 工學院 | zh_TW |
dc.contributor.author-dept | 土木工程學研究所 | zh_TW |
顯示於系所單位: | 土木工程學系 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-104-1.pdf 目前未授權公開取用 | 45.14 MB | Adobe PDF |