請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/50542
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 鍾孝文(Hsiao-Wen Chung) | |
dc.contributor.author | Chou-Ming Cheng | en |
dc.contributor.author | 鄭州閔 | zh_TW |
dc.date.accessioned | 2021-06-15T12:45:20Z | - |
dc.date.available | 2020-08-24 | |
dc.date.copyright | 2020-08-24 | |
dc.date.issued | 2020 | |
dc.date.submitted | 2020-08-18 | |
dc.identifier.citation | 1. Ragan DK, McKinstry R, Benzinger T, Leonard JR, Pineda JA. Alterations in cerebral oxygen metabolism after traumatic brain injury in children. J Cereb Blood Flow Metab. 2013;33:48-52. 2. Zheng G, Lu H, Yu W, et al. Severity-specific alterations in CBF, OEF and CMRO2 in cirrhotic patients with hepatic encephalopathy. Eur Radiol. 2017;27:4699-4709. 3. Wehrli FW, Fan AP, Rodgers ZB, Englund EK, Langham MC. Susceptibility-based time-resolved whole-organ and regional tissue oximetry. NMR Biomed 2017;30:e3495. 4. Yadav BK, Krishnamurthy U, Buch S, et al. Imaging putative foetal cerebral blood oxygenation using susceptibility weighted imaging (SWI). Eur Radiol. 2018;28:1884-1890. 5. Fan AP, Bilgic B, Gagnon L, et al. Quantitative oxygenation venography from MRI phase. Magn Reson Med. 2014;72:149-159. 6. Jain V, Langham MC, Wehrli FW. MRI estimation of global brain oxygen consumption rate. J Cereb Blood Flow Metab. 2010;30:1598-1607. 7. Xu F, Ge Y, Lu H. Noninvasive quantification of whole-brain cerebral metabolic rate of oxygen (CMRO2) by MRI. Magn Reson Med. 2009;62:141-148. 8. Miao X, Nayak KS, Wood JC. In vivo validation of T2- and susceptibility-based SvO2 measurements with jugular vein catheterization under hypoxia and hypercapnia. Magn Reson Med. 2019;82:2188-2198. 9. Fernández-Seara MA, Techawiboonwong A, Detre JA, Wehrli FW. MR susceptometry for measuring global brain oxygen extraction. Magn Reson Med. 2006;55:967-973. 10. Neelavalli J, Jella PK, Krishnamurthy U, et al. Measuring venous blood oxygenation in fetal brain using susceptibility-weighted imaging. J Magn Reson Imaging. 2014;39:998-1006. 11. Yuan C, Gullberg GT, Parker DL. Flow-induced phase effects and compensation technique for slice-selective pulses. Magn Reson Med. 1989;9:161-176. 12. Xu B, Liu T, Spincemaille P, Prince M, Wang Y. Flow compensated quantitative susceptibility mapping for venous oxygenation imaging. Magn Reson Med. 2014;72:438-445. 13. Wu D, Liu S, Buch S, Ye Y, Dai Y, Haacke EM. A fully flow-compensated multiecho susceptibility-weighted imaging sequence: The effects of acceleration and background field on flow compensation. Magn Reson Med. 2016;76:478-489. 14. Rodgers ZB, Jain V, Englund EK, Langham MC, Wehrli FW. High temporal resolution MRI quantification of global cerebral metabolic rate of oxygen consumption in response to apneic challenge. J Cereb Blood Flow Metab. 2013;33:1514-1522. 15. Barhoum S, Langham MC, Magland JF, et al. Method for rapid MRI quantification of global cerebral metabolic rate of oxygen. J Cereb Blood Flow Metab. 2015;35:1616-1622. 16. Lee H, Langham MC, Rodriguez-Soto AE, Wehrli FW. Multiplexed MRI methods for rapid estimation of global cerebral metabolic rate of oxygen consumption. Neuroimage. 2017;149:393-403. 17. Haacke EM, Liu S, Buch S, Zheng W, Wu D, Ye Y. Quantitative susceptibility mapping: current status and future directions. Magn Reson Imaging. 2015;33:1-25. 18. Wang Y, Spincemaille P, Liu Z, et al. Clinical quantitative susceptibility mapping (QSM): Biometal imaging and its emerging roles in patient care. J Magn Reson Imaging. 2017;46:951-971. 19. Duerk JL, Pattany PM. Analysis of imaging axes significance in motion artifact suppression technique (MAST): MRI of turbulent flow and motion. Magn Reson Imaging. 1989;7:251-263. 20. Jordan JE, Pelc NJ, Enzmann DR. Velocity and flow quantitation in the superior sagittal sinus with ungated and cine (gated) phase-contrast MR imaging. J Magn Reson Imaging. 1994;4:25-28. 21. Hirabuki N, Watanabe Y, Mano T, et al. Quantitation of flow in the superior sagittal sinus performed with cine phase-contrast MR imaging of healthy and achondroplastic children. AJNR Am J Neuroradiol. 2000;21:1497-1501. 22. Becker G, Bogdahn U, Gehlberg C, Fröhlich T, Hofmann E, Schlief MD. Transcranial color-coded real-time sonography of intracranial veins. Normal values of blood flow velocities and findings in superior sagittal sinus thrombosis. J Neuroimaging. 1995;5:87-94. 23. LanghamMC, Magland JF, Epstein CL, Floyd TF, Wehrli FW. Accuracy and precision ofMR blood oximetry based on the long paramagnetic cylinder approximation of large vessels. Magn Reson Med. 2009;62:333-340. 24. Jain V, Abdulmalik O, Propert KJ, Wehrli FW. Investigating the magnetic susceptibility properties of fresh human blood for noninvasive oxygen saturation quantification. Magn Reson Med. 2012;68:863-867. 25. Coles JP, Minhas PS, Fryer TD, et al. Effect of hyperventilation on cerebral blood flow in traumatic head injury: clinical relevance and monitoring correlates. Crit Care Med. 2002;30:1950-1959. 26. Nagdyman N, Fleck T, Schubert S, et al. Comparison between cerebral tissue oxygenation index measured by near-infrared spectroscopy and venous jugular bulb saturation in children. Intensive Care Med. 2005;31:846-850. 27. Barhoum S, Rodgers ZB, Langham M, Magland JF, Li C, Wehrli FW. Comparison of MRI methods for measuring whole-brain venous oxygen saturation. Magn Reson Med. 2015;73:2122-2128. 28. Rodgers ZB, Leinwand SE, Keenan BT, Kini LG, Schwab RJ, Wehrli FW. Cerebral metabolic rate of oxygen in obstructive sleep apnea at rest and in response to breath‐hold challenge. J Cereb Blood Flow Metab. 2016;36:755-767. 29. Jiang D, Lin Z, Liu P, et al. Normal variations in brain oxygen extraction fraction are partly attributed to differences in end-tidal CO2. J Cereb Blood Flow Metab. 2020;40:1492-1500. 30. Cao W, Chang YV, Englund EK, et al. High-speed whole-brain oximetry by golden-angle radial MRI. Magn Reson Med. 2018;79:217-223. 31. Denk C, Rauscher A. Susceptibility weighted imaging with multiple echoes. J Magn Reson Imaging. 2010;31:185-191. 32. Du YP, Jin Z, Hu Y, Tanabe J. Multi-echo acquisition of MR angiography and venography of the brain at 3 Tesla. J Magn Reson Imaging. 2009;30:449-454. 33. Haacke EM, Tang J, Neelavalli J, Cheng YC. Susceptibility mapping as a means to visualize veins and quantify oxygen saturation. J Magn Reson Imaging. 2010;32:663-676. 34. Fan AP, Evans KC, Stout JN, Rosen BR, Adalsteinsson E. Regional quantification of cerebral venous oxygenation from MRI susceptibility during hypercapnia. Neuroimage. 2015;104:146-155. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/50542 | - |
dc.description.abstract | 目的: 這研究發現利用磁化率磁振氧氣飽和方法評估上矢狀竇靜脈氧氣飽和度會有不同切面上的差異,進而探討血流速度及加速度效應對此現象的影響。 方法: 招募15位健康受試者進行兩次磁振造影掃描並配合一階沿身體前後側方向的血流補償以得到三維多梯度迴訊的影像。在所有切面中上矢狀竇的相位值都和迴訊時間進行線性迴歸以得到皮爾森相關係數(PCC),而其中最高值的切面受到加速度影響最小。利用這張切面的奇數迴訊所計算的靜脈氧氣飽和度評估兩次的掃描間差異及其和中央第十五張的切面間差異,而兩種差異都是利用布蘭德-奧特曼分析評估。檢視不同切面的掃描間差異和皮爾森相關係數的關係。將皮爾森相關係數高於某閾值的切面用於計算得到多切面平均靜脈氧氣飽和度的值。 結果: 在兩標準差之下,靜脈氧氣飽和度的切面相關差異分布從–16.2 到 21.5%和最近文獻結果吻合,而且此差異分布約略大於自動選取切面(–7.5~10.3%)和中央第15張切面(–8.0~8.8%)掃描間差異分布的兩倍。對皮爾森相關係數大於|-0.98|的切面,切面間靜脈氧氣飽和度的變動全都小於5.0%。利用皮爾森相關係數大於|-0.98|的切面得到之多切面平均靜脈氧氣飽和度更進一步減少掃描間差異分布至–4.7~8.2%。 結論: 血流加速度的效應可以部分解釋靜脈氧氣飽和度的切面相關差異。我們使用傳統三維多梯度迴訊序列在有脈動血流下提供可靠的靜脈氧氣飽和度之評估方法。 | zh_TW |
dc.description.abstract | Purpose: This work investigates the effects of flow acceleration in the superior sagittal sinus (SSS) on slice-dependent variations in venous oxygen saturation (SvO2) estimations using susceptibility-based MR oximetry. Methods: Three-dimensional (3D) multiple gradient-echo images, with first-order flow compensation along the anterior-posterior readout direction for the first echo, were acquired twice from 15 healthy volunteers. For all slices, phases within SSS were fitted using linear regression across four TEs to obtain the Pearson's correlation coefficients (PCC), the largest of which corresponded to minimum acceleration influence. SvO2 derived from odd echoes on this slice was used to assess inter-scan difference, and compared with the central 15th slice for slice-dependent difference, both using Bland-Altman analysis. Within-scan inter-slice SvO2 consistency was examined versus PCC. Multi-slice-averaged SvO2 values were then computed from slices with PCCs above a certain threshold. Results: Slice-dependent difference in SvO2 varied from –16.2 to 21.5% at two standard deviations, in agreement with a recent report, and about twice larger than inter-scan differences for the automatically selected slice (–7.5 to 10.3%) and for the central 15th slice (–8.0 to 8.8%). For slices with PCCs higher than |–0.98|, inter-slice SvO2 deviations were all found to be less than 5.0%. Multi-slice-averaged SvO2 with PCCs higher than |–0.98| further reduced inter-scan difference to –4.7 to 8.2%. Conclusion: Slice-dependent variations in SvO2 may partly be explained by the effects of flow acceleration. Our method may enable conventional 3D multiple gradient-echo to be used for SvO2 estimations in the presence of pulsatile flow. | en |
dc.description.provenance | Made available in DSpace on 2021-06-15T12:45:20Z (GMT). No. of bitstreams: 1 U0001-1108202010532200.pdf: 2020422 bytes, checksum: ef4a7d05466ec847e49534db565de7c3 (MD5) Previous issue date: 2020 | en |
dc.description.tableofcontents | 口試委員會審定書………………………………….… i 誌謝…………………………………………………………………. ii 中文摘要………………………………………………………. iii English abstract……………………….…….. v List of Figures..………………………………… viii List of Tables..….…………………….….. ix Introduction…………………………………………. 1 Materials and Methods…………………. 3 Results…………………………………………….………. 13 Discussions……………………………………………. 20 References………………………………………………. 25 | |
dc.language.iso | en | |
dc.title | 利用傳統三維多梯度迴訊磁振造影進行上矢狀竇靜脈氧氣飽和度的量測:探討血流速度及加速度的效應 | zh_TW |
dc.title | Measurements of venous oxygen saturation in the superior sagittal sinus using conventional three-dimensional multiple gradient-echo MR imaging : effects of flow velocity and acceleration | en |
dc.type | Thesis | |
dc.date.schoolyear | 108-2 | |
dc.description.degree | 博士 | |
dc.contributor.oralexamcommittee | 黃國書(Guo-Shu Huang),葉子成(Tzu-Chen Yeh),王昭穎(Chao-Ying Wang),吳明龍(Ming-Long Wu),莊子肇(Tzu-Chao Chuang) | |
dc.subject.keyword | 靜脈氧氣飽和度,上矢狀竇,多梯度迴訊,梯度累積量歸零,血流加速度, | zh_TW |
dc.subject.keyword | venous oxygen saturation,superior sagittal sinus,multiple gradient-echo,gradient moment nulling,flow acceleration, | en |
dc.relation.page | 30 | |
dc.identifier.doi | 10.6342/NTU202002910 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2020-08-19 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 生醫電子與資訊學研究所 | zh_TW |
顯示於系所單位: | 生醫電子與資訊學研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
U0001-1108202010532200.pdf 目前未授權公開取用 | 1.97 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。