請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/46063
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 張瑞峰(Ruey-Feng Chang) | |
dc.contributor.author | Liang-Chun Yin | en |
dc.contributor.author | 尹亮鈞 | zh_TW |
dc.date.accessioned | 2021-06-15T04:52:46Z | - |
dc.date.available | 2015-08-16 | |
dc.date.copyright | 2010-08-16 | |
dc.date.issued | 2010 | |
dc.date.submitted | 2010-07-30 | |
dc.identifier.citation | [1] J. N. Wolfe, 'Risk for breast-cancer development determined by mammographic parenchymal pattern,' Cancer, vol. 37, pp. 2486-2492, 1976.
[2] C. Byrne, C. Schairer, J. Wolfe, N. Parekh, M. Salane, L. A. Brinton, R. Hoover, and R. Haile, 'Mammographic features and breast-cancer risk - effects with time, age, and menopause status,' J Natl Cancer I, vol. 87, pp. 1622-1629, Nov 1 1995. [3] J. J. Heine and P. Malhotra, 'Mammographic tissue, breast cancer risk, serial image analysis, and digital mammography part 1. Tissue and related risk factors,' Acad Radiol, vol. 9, pp. 298-316, Mar 2002. [4] C. H. van Gils, J. H. C. L. Hendriks, R. Holland, N. Karssemeijer, J. D. M. Otten, H. Straatman, and A. L. M. Verbeek, 'Changes in mammographic breast density and concomitant changes in breast cancer risk,' Eur J Cancer Prev, vol. 8, pp. 509-515, Dec 1999. [5] J. J. Heine and P. Malhotra, 'Mammographic tissue, breast cancer risk, serial image analysis, and digital mammography part 2. Serial breast tissue change and related temporal influences,' Acad Radiol, vol. 9, pp. 317-335, Mar 2002. [6] A. F. Saftlas, J. N. Wolfe, R. N. Hoover, L. A. Brinton, C. Schairer, M. Salane, and M. Szklo, 'Mammographic parenchymal patterns as indicators of breast-cancer risk,' Am J Epidemiol, vol. 129, pp. 518-526, Mar 1989. [7] N. F. Boyd, H. Guo, L. J. Martin, L. Sun, J. Stone, E. Fishell, R. A. Jong, G. Hislop, A. Chiarelli, S. Minkin, and M. J. Yaffe, 'Mammographic density and the risk and detection of breast cancer,' N. Engl. J. Med., vol. 356, pp. 227-36, Jan 18 2007. [8] Y. Kotsuma, Y. Tamaki, T. Nishimura, M. Tsubai, S. Ueda, K. Shimazu, S. Jin Kim, Y. Miyoshi, Y. Tanji, T. Taguchi, and S. Noguchi, 'Quantitative assessment of mammographic density and breast cancer risk for japanese women,' Breast, vol. 17, pp. 27-35, Feb 2008. [9] J. W. Byng, M. J. Yaffe, R. A. Jong, R. S. Shumak, G. A. Lockwood, D. L. Tritchler, and N. F. Boyd, 'Analysis of mammographic density and breast cancer risk from digitized mammograms,' Radiographics, vol. 18, pp. 1587-1598, Nov-Dec 1998. [10] P. K. Saha, J. K. Udupa, E. F. Conant, D. P. Chakraborty, and D. Sullivan, 'Breast tissue density quantification via digitized mammograms,' Ieee T Med Imaging, vol. 20, pp. 792-803, Aug 2001. [11] X. H. Wang, W. F. Good, B. E. Chapman, Y. H. Chang, W. R. Poller, T. S. Chang, and L. A. Hardesty, 'Automated assessment of the composition of breast tissue revealed on tissue-thickness-corrected mammography,' Am J Roentgenol, vol. 180, pp. 257-262, Jan 2003. [12] O. Pawluczyk, B. J. Augustine, M. J. Yaffe, D. Rico, J. W. Yang, G. E. Mawdsley, and N. F. Boyd, 'A volumetric method for estimation of breast density on digitized screen-film mammograms,' Med Phys, vol. 30, pp. 352-364, Mar 2003. [13] S. van Engeland, P. R. Snoeren, H. Huisman, C. Boetes, and N. Karssemeijer, 'Volumetric breast density estimation from full-field digital mammograms,' IEEE Trans. Med. Imaging, vol. 25, pp. 273-82, Mar 2006. [14] M. J. Yaffe, 'Mammographic density. Measurement of mammographic density,' Breast Cancer Res, vol. 10, p. 209, 2008. [15] K. Marias, C. Behrenbruch, R. Highnam, S. Parbhoo, A. Seifalian, and M. Brady, 'A mammographic image analysis method to detect and measure changes in breast density,' Eur J Radiol, vol. 52, pp. 276-282, Dec 2004. [16] O. Alonzo-Proulx, N. Packard, J. M. Boone, A. Al-Mayah, K. K. Brock, S. Z. Shen, and M. J. Yaffe, 'Validation of a method for measuring the volumetric breast density from digital mammograms,' Phys Med Biol, vol. 55, pp. 3027-3044, Jun 7 2010. [17] B. Fisher, J. P. Costantino, D. L. Wickerham, C. K. Redmond, M. Kavanah, W. M. Cronin, V. Vogel, A. Robidoux, N. Dimitrov, J. Atkins, M. Daly, S. Wieand, E. Tan-Chiu, L. Ford, and N. Wolmark, 'Tamoxifen for prevention of breast cancer: Report of the national surgical adjuvant breast and bowel project p-1 study,' J Natl Cancer I, vol. 90, pp. 1371-1388, Sep 16 1998. [18] B. Fisher, J. P. Costantino, D. L. Wickerham, R. S. Cecchini, W. M. Cronin, A. Robidoux, T. B. Bevers, M. T. Kavanah, J. N. Atkins, R. G. Margolese, C. D. Runowicz, J. M. James, L. G. Ford, and N. Wolmark, 'Tamoxifen for the prevention of breast cancer: Current status of the national surgical adjuvant breast and bowel project p-1 study,' J Natl Cancer I, vol. 97, pp. 1652-1662, Nov 16 2005. [19] V. G. Vogel, J. P. Costantino, D. L. Wickerham, W. M. Cronin, R. S. Cecchini, J. N. Atkins, T. B. Bevers, L. Fehrenbacher, E. R. Pajon, J. L. Wade, A. Robidoux, R. G. Margolese, J. James, S. M. Lippman, C. D. Runowicz, P. A. Ganz, S. E. Reis, W. McCaskill-Stevens, L. G. Ford, V. C. Jordan, N. Wolmark, and Nsabp, 'Effects of tamoxifen vs raloxifene on the risk of developing invasive breast cancer and other disease outcomes - the nsabp study of tamoxifen and raloxifene (star) p-2 trial,' Jama-J Am Med Assoc, vol. 295, pp. 2727-2741, Jun 21 2006. [20] R. C. Coombes, E. Hall, L. J. Gibson, R. Paridaens, J. Jassem, T. Delozier, S. E. Jones, I. Alvarez, G. Bertelli, O. Ortmann, A. S. Coates, E. Bajetta, D. Dodwell, R. E. Coleman, L. J. Fallowfield, E. Mickiewicz, J. Andersen, P. E. Lonning, G. Cocconi, A. Stewart, N. Stuart, C. F. Snowdon, M. Carpentieri, G. Massimini, J. M. Bliss, and I. E. Study, 'A randomized trial of exemestane after two to three years of tamoxifen therapy in postmenopausal women with primary breast cancer,' New Engl J Med, vol. 350, pp. 1081-1092, Mar 11 2004. [21] J. Cuzick, J. Warwick, L. Pinney, R. Warren, S. Cawthorn, A. Howell, and S. Duffy, 'Change in breast density as a biomarker of breast cancer risk reduction; results from ibis-1.,' Cancer Res, vol. 69, pp. 77s-78s, Jan 15 2009. [22] A. Burgess, 'On the noise variance of a digital mammography system,' Med Phys, vol. 31, pp. 1987-95, Jul 2004. [23] P. R. Snoeren and N. Karssemeijer, 'Thickness correction of mammographic images by means of a global parameter model of the compressed breast,' IEEE Trans. Med. Imaging, vol. 23, pp. 799-806, Jul 2004. [24] J. W. Byng, M. J. Yaffe, R. A. Jong, R. S. Shumak, G. A. Lockwood, D. L. Tritchler, and N. F. Boyd, 'Analysis of mammographic density and breast cancer risk from digitized mammograms,' Radiographics, vol. 18, pp. 1587-98, Nov-Dec 1998. [25] N. Karssemeijer, 'Automated classification of parenchymal patterns in mammograms,' Phys Med Biol, vol. 43, pp. 365-78, Feb 1998. [26] X. H. Wang, B. E. Chapman, C. A. Britton, S. K. Golla, L. P. Wallace, and W. F. Good, 'Evaluation of quantitative measures of breast tissue density from mammography with truth from MRI data,' San Diego, CA, USA, 2003, pp. 82-89. [27] X. H. Wang, W. F. Good, B. E. Chapman, Y. H. Chang, W. R. Poller, T. S. Chang, and L. A. Hardesty, 'Automated assessment of the composition of breast tissue revealed on tissue-thickness-corrected mammography,' AJR Am J Roentgenol, vol. 180, pp. 257-62, Jan 2003. [28] X. H. Wang, B. Zheng, Y.-H. Chang, and W. F. Good, 'Correction of digitized mammograms to enhance soft display and tissue composition measurement,' San Diego, CA, USA, 2001, pp. 328-336. [29] J. J. Heine and J. A. Thomas, 'Effective x-ray attenuation coefficient measurements from two full field digital mammography systems for data calibration applications,' Biomed Eng Online, vol. 7, pp. -, Mar 28 2008. [30] J. Kaufhold, J. A. Thomas, J. W. Eberhard, C. E. Galbo, and D. E. G. Trotter, 'A calibration approach to glandular tissue composition estimation in digital mammography,' Medical Physics, vol. 29, pp. 1867-1880, Aug 2002. [31] O. Pawluczyk, B. J. Augustine, M. J. Yaffe, D. Rico, J. Yang, G. E. Mawdsley, and N. F. Boyd, 'A volumetric method for estimation of breast density on digitized screen-film mammograms,' Med Phys, vol. 30, pp. 352-64, Mar 2003. [32] D. Roller and C. Lampasona, 'A method for interpreting pixel grey levels in digital mammography,' Lect Notes Comput Sc, vol. 4142, pp. 580-588, 2006. [33] J. A. Hartigan, Clustering algorithms: John Wiley; Sons, Inc., 1975. [34] K. Cios, W. Pedrycz, and R. W. Swiniarski, Data mining methods for knowledge discovery: Kluwer Academic Publishers, 1998. [35] J. Eng-Wong, J. Orzano-Birgani, C. K. Chow, D. Venzon, J. Yao, C. E. Galbo, J. A. Zujewski, and S. Prindiville, 'Effect of raloxifene on mammographic density and breast magnetic resonance imaging in premenopausal women at increased risk for breast cancer,' Cancer Epidemiol. Biomarkers Prev., vol. 17, pp. 1696-701, Jul 2008. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/46063 | - |
dc.description.abstract | 乳癌是女性最普遍的惡性腫瘤之一,而且一直以來是世界各地女性的主要死因。許多研究指出高乳房密度的女性較低乳房密度的女性有更高的罹患乳癌風險。因此,乳房密度被認為在乳癌風險預測上具有極大的意義。大多數的乳房密度研究都是使用乳房X光影像。由於2維的乳房X光影像在密度分析上的變異較大,所以在最近的一些研究中,3維核磁共振攝影的使用已被當作能取得更為適當結果的主要途徑。然而,本篇論文將會在乳房X光影像中使用3維的方法來計算乳房密度。此方法是基於乳房的組成能分為脂肪組織和腺體組織兩種。利用X光在兩種組織具有不同的衰減係數以取得組成比例。再將乳房X光影像得到的密度分析結果與乳房核磁共振影像所取得的結果作比較。來自17個病人的實驗結果顯示乳房X光影像和乳房核磁共振影像兩者所得到的結果有高度相關性。此外,本篇論文所使用的乳房密度計算的方法也應用在39個病人的化學預防治療實驗結果中,做為追蹤乳房密度的變化情形。其中32個病例經過治療後的腺體體積出現下降的情形,其體積下降的百分比為13.40%。然而,有7個病例的腺體體積在經過化學預防治療後上升了5.72%,其中6個上升的病例其治療時間較短(少於12個月)。 | zh_TW |
dc.description.abstract | Breast cancer is one of the most common malignancies in women and it continues to be a major cause of death among women worldwide. Several studies have shown that the women with dense breasts are at higher risk than the women whose breasts are less dense. Hence, breast density has to be accepted as a clinically highly significant predictor of breast cancer risk. Most studies of breast density are performed on the mammographic images. Because the two-dimensional (2-D) mammographic density shows large variability, the three-dimension (3-D) breast magnetic resonance imaging (MRI) has been used in some recent studies for achieving more reasonable consistency. In this paper, we propose a three-dimension (3-D) method to estimate the breast density with digital mammograms. This method is based on the assumption that the composition of the breast contains only two types, the fat tissue and the fibroglandular tissue. The linear attenuation coefficients of these tissues are used to obtain the composition at a given pixel. The density estimations of the mammographic images are compared with the results in the MRI. The validation between the MRI and the digital mammograms using 17 cases has been performed and shows a high correlation. Also, the proposed volumetric breast density estimation using the mammographic images is applied to evaluate the breast density change for 39 patients with the chemoprevention treatments. In 32 of 39 cases, the fibroglandular volume after treatment is reduced and the fibroglandular volume reduction is 13.40%. However, there are 7 cases with their fibroglandular volume increasing of 5.72% after the chemoprevention and 6 of 7 increasing cases receive shorter treatment (less than 12 months). | en |
dc.description.provenance | Made available in DSpace on 2021-06-15T04:52:46Z (GMT). No. of bitstreams: 1 ntu-99-R97922123-1.pdf: 1227734 bytes, checksum: 3132d4ba4108837336148af14aefdbef (MD5) Previous issue date: 2010 | en |
dc.description.tableofcontents | ACKNOWLEDGEMENTS ii
摘要 iii ABSTRACT iv TABLE OF CONTENT vi LIST OF FIGURES vii LIST OF TABLES ix Chapter 1 Introduction 1 Chapter 2 Materials 4 Chapter 3 The Density Analysis Method 5 3.1 Unprocessed Digital Mammograms 6 3.2 Breast Segmentation 8 3.3 Fat Attenuation Coefficient 10 3.4 Fibroglandular Attenuation Coefficient 16 3.5 Volume and Density 17 Chapter 4 Experiment and Result 20 4.1 MRI and Mammographic Densities 20 4.2 Chemoprevention Density Change Using Processed Mammographic Images 21 4.3 Chemoprevention Density Change Using Unprocessed Mammographic Images 36 4.4 Discussion 52 Chapter 5 Conclusion and Future Works 55 References 58 | |
dc.language.iso | en | |
dc.title | 乳房X光片之3D密度分析 | zh_TW |
dc.title | Volumetric Breast Density Analysis for Digital Mammograms | en |
dc.type | Thesis | |
dc.date.schoolyear | 98-2 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 黃俊升,張允中 | |
dc.subject.keyword | 乳癌,乳房密度,X光影像,核磁共振,密度分析,化學預防治療, | zh_TW |
dc.subject.keyword | breast cancer,breast density,digital mammograms,MRI,density analysis,chemoprevention, | en |
dc.relation.page | 61 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2010-07-30 | |
dc.contributor.author-college | 電機資訊學院 | zh_TW |
dc.contributor.author-dept | 資訊工程學研究所 | zh_TW |
顯示於系所單位: | 資訊工程學系 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-99-1.pdf 目前未授權公開取用 | 1.2 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。