請用此 Handle URI 來引用此文件:
http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/41901
完整後設資料紀錄
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.advisor | 林嘉明 | |
dc.contributor.author | Yi-Chun Liu | en |
dc.contributor.author | 劉怡君 | zh_TW |
dc.date.accessioned | 2021-06-15T00:36:33Z | - |
dc.date.available | 2010-02-10 | |
dc.date.copyright | 2009-02-10 | |
dc.date.issued | 2009 | |
dc.date.submitted | 2008-12-10 | |
dc.identifier.citation | 1.Nalli S, Horn OJ, Grochowalski AR, Cooper DG, Nicell JA. Origin of 2-ethylhexanol as a VOC. Environmental Pollution 2006;140:181-185.
2.Kondo F, Ikai Y, Goto T, Ito Y, Oka H, Nakazawa H, Odajima Y, Kamijima M, Shibata E, Torii S, Miyazaki Y. Two sensitive sick-building syndrome patients possibly responding to p-dichlorobenzene and 2-ethyl-1-hexanol: Case report. Journal of Health Science 2007;53(1):119-123. 3.Nakazawa H, Ikeda H, Yamashita T, Hara I, Kumai Y, Endo G, Endo Y. A case of sick building syndrome in a Japanese office worker. Industrial Health 2005;43(2):341-345. 4.Tuomainen A, Seuri M, Sieppi A. Indoor air quality and health problems associated with damp floor coverings. International Archives of Occupational and Environmental Health 2004;77:222-226. 5.Claeson A-S, Sandstron M, Sunesson A-L. Volatile organic compounds (VOCs) emitted from materials collected from buildings affected by microorganisms. Journal of Environmental Monitoring 2007;9:240-245. 6.行政院環保署. http://www.epa.gov.tw 2008. 7.江哲銘. 辦公建築室內空氣品質之研究. 內政部建築研究所 1993. 8.江哲銘, 賴榮平, 王文安, 周柏丞, 賴啟銘, 李彥頤, 涂玉峰. 辦公建築室內空氣品質與空調設備之診斷研究. 內政部建築研究所 1998. 9.Burge PS. Sick building syndrome. Occupational and Environmental Medicine 2004;61(2):185-190. 10.Kreiss K. The sick building syndrome - where is the epidemiologic basis. American Journal of Public Health 1990;80(10):1172-1173. 11.Bourbeau J, Brisson C, Allaire S. Prevalence of the sick building syndrome symptoms in office workers before and six months and three years after being exposed to a building with an improved ventilation system. Occupational and Environmental Medicine 1997;54(1):49-53. 12.Neuner R, Seidel HJ. Adaptation of office workers to a new building - Impaired well-being as part of the sick-building-syndrome. International Journal of Hygiene and Environmental Health 2006;209(4):367-375. 13.Brasche S, Bullinger M, Morfeld M, Gebhardt HJ, Bischof W. Why do women suffer from sick building syndrome more often than men? Subjective higher sensitivity versus objective causes. Indoor Air-International Journal of Indoor Air Quality and Climate 2001;11(4):217-222. 14.Kubo T, Mizoue T, Ide R, Tokui N, Fujino Y, Minh PT, Shirane K, Matsumoto T, Yoshimura T. Visual display terminal work and sick building syndrome - the role of psychosocial distress in the relationship. Journal of Occupational Health 2006;48(2):107-112. 15.Mizoue T, Reijula K, Andersson K. Environmental tobacco smoke exposure and overtime work as risk factors for sick building syndrome in Japan. American Journal of Epidemiology 2001;154(9):803-808. 16.張晏蓉, 葉婉瑜, 陳春萬, 陳秋蓉, 鄭雅文, 石東生. 台灣受雇者疲勞的分布狀況與相關因素. 台灣衛誌 2007;26(1). 17.Sundell J, Anderssoon B, Andersson K, Lindvall T. Volatile organic compounds in ventilating air in buildings at different sampling points in the buildings and their relationship with the prevalence of occupant symptoms. Indoor air 1993;3:82-93. 18.Engvall K, Norrby C, Norback D. Sick building syndrome in relation to building dampness in multi-family residential buildings in Stockholm. International Archives of Occupational and Environmental Health 2001;74(4):270-278. 19.Laumbach RJ, Kipen HM. Bioaerosols and sick building syndrome: particles, inflammation, and allergy. Current Opinion in Allergy and Clinical Immunology 2005;5(2):135-139. 20.R.Bholah, Subratty AH. Indoor biological contaminants and symptoms of sick building syndrome in office buildings in Mauritius. International Journal of Environmental Health Research 2002;12:93-98. 21.Cooley JD, Wong WC, Jumper CA, Straus DC. Correlation between the prevalence of certain fungi and sick building syndrome. Occupational and Environmental Medicine 1998;55(9):579-584. 22.Engvall K, Norrby C, Norback D. Asthma symptoms in relation to building dampness and odour in older multifamily houses in Stockholm. International Journal of Tuberculosis and Lung Disease 2001;5(5):468-477. 23.Norbäck D, Wieslander G, Nordström K, Wålinder R. Asthma symptoms in relation to measured building dampness in upper concrete floor construction, and 2-ethyl-1-hexanol in indoor air. International Journal of Tuberculosis and Lung Disease 2000;4(11):1016-1025. 24.Norback D, Bjornsson E, Janson C, Palmgren U, Boman G. Current asthma and biochemical signs of inflammation in relation to building dampness in dwellings. International Journal of Tuberculosis and Lung Disease 1999;3(5):368-376. 25.Li CS, Hsu CW, Lu CH. Dampness and respiratory symptoms among workers in daycare centers in a subtropical climate. Archives of Environmental Health 1997;52(1):68-71. 26.Wan GH, Li CS. Dampness and airway inflammation and systemic symptoms in office building workers. Archives of Environmental Health 1999;54(1):58-63. 27.Norback D, Wieslander G, Nordstrom K, Walinder R. Asthma symptoms in relation to measured building dampness in upper concrete floor construction, and 2-ethyl-1-hexanol in indoor air. International Journal of Tuberculosis and Lung Disease 2000;4(11):1016-1025. 28.Sakai K, Kamijima M, Shibata E, Ohno H, Nakajima T. Indoor air pollution by 2-ethyl-1-hexanol in non-domestic buildings in Nagoya, Japan. Journal of Environmental Monitoring 2006;8(11):1122-1128. 29.Hodgson AT, Wooley JD, Daisey JM. Emissions of volatile organic-compounds from new carpets measured in a large-scale environmental chamber. Journal of the Air & Waste Management Association 1993;43(3):316-324. 30.Dietert RR, Hedge A. Toxicological considerations in evaluating indoor air quality and human health: Impact of new carpet emissions. Critical Reviews in Toxicology 1996;26(6):633-707. 31.Deng BQ, Kim CN, Zhang F. Numerical simulation of VOCs distribution in a room with a new carpet. Heat and Mass Transfer 2007;43(10):975-983. 32.Jaakkola JJK, Verkasalo PK, Jaakkola N. Plastic wall materials in the home and respiratory health in young children. American Journal of Public Health 2000;90(5):797-799. 33.Stadler JC, Kennedy GL. Evaluation of the sensory irritation potential of volatile organic chemicals from carpets - alone and in combination. Food and Chemical Toxicology 1996;34(11-12):1125-1130. 34.Kamijima M, Sakai K, Shibata E, Yamada T, Itohara S, Ohno H, Hayakawa R, Sugiura M, Yamaki K, Takeuchi Y. 2-ethyl-1-hexanol in indoor air as a possible cause of sick building symptoms. Journal of Occupational Health 2002;44(3):186-191. 35.張碧芬, 袁紹英. 鄰苯二甲酸酯類環境荷爾蒙對生物的影響. 環境檢驗通訊雜誌 1990;31. 36.謝和霖. 死神之媒PVC. 看守台灣季刊 2002;4(2):90-95. 37.Pasanen P, Korpi A, Kalliokoski P, Pasanen AL. Growth and volatile metabolite production of Aspergillus versicolor in house dust. Environment International 1997;23(4):425-432. 38.Nalli S, Cooper DG, Nicell JA. Metabolites from the biodegradation of di-ester plasticizers by Rhodococcus rhodochrous. Science of the Total Environment 2006;366(1):286-294. 39.Nalli S, Cooper DG, Nicell JA. Interaction of metabolites with R-rhodochrous during the biodegradation of di-ester plasticizers. Chemosphere 2006;65(9):1510-1517. 40.Horn O, Nalli S, Cooper D, Nicell J. Plasticizer metabolites in the environment. Water Research 2004;38(17):3693-3698. 41.Wieslander G, Norback D, Nordstrom K, Walinder R, Venge P. Nasal and ocular symptoms, tear film stability and biomarkers in nasal lavage, in relation to building-dampness and building design in hospitals. International Archives of Occupational and Environmental Health 1999;72:451-461. 42.Thriel Cv, Seeber A, Kiesswetter E, Blaszkewicz M, Golka K, ller GAW. Physiological and psychological approaches to chemosensory effects of solvents. Toxicology Letters 2003;140-141:261-271. 43.Fischer G, Dott W. Relevance of airborne fungi and their secondary metabolites for environmental, occupational and indoor hygiene. Arch Microbiol 2003;179 75-82. 44.Pirhonen I, Nevalainen A, Husman T, Pekkanen J. Home dampness, moulds and their influence on respiratory infections and symptoms in adults in Finland. European Respiratory Journal 1996;9(12):2618-2622. 45.Straus DC, Cooley JD, Wong WC, Jumper CA. Studies on the role of fungi in sick building syndrome. Archives of Environmental Health 2003;58(8):475-478. 46.Kuo YM, Li CS. Seasonal fungus prevalence inside and outside of domestic environments in the subtropical climate. Atmospheric Environment 1994;28(19):3125-3130. 47.Li CS, Hsu LY, Chou CC, Hsieh KH. Fungus allergens inside and outside the residences of atopic and control children. Archives of Environmental Health 1995;50(1):38-43. 48.Li CS, Hsu LY. Airborne fungus allergen in association with residential characteristics in atopic and control children in a subtropical region. Archives of Environmental Health 1997;52(1):72-79. 49.Kim JL, Elfman L, Mi Y, Wieslander G, Smedje G, Norback D. Indoor molds, bacteria, microbial volatile organic compounds and plasticizers in schools - associations with asthma and respiratory symptoms in pupils. Indoor Air 2007;17(2):153-163. 50.劉芸汶. ㄧ般辦公室大樓空氣及灰塵中活性真菌濃度與病態大樓症候群之相關性探討. 成功大學環境醫學研究所碩士論文 2003. 51.紀碧芳. 受黴菌污染建材上之黴菌種類研究. 成功大學環境醫學研究所碩士論文 2003. 52.Hirvonen MR, Huttunen K, Roponen M. Bacterial strains from moldy buildings are highly potent inducers of inflammatory and cytotoxic effects. Indoor Air 2005;15:65-70. 53.Vas G, Vekey K. Solid-phase microextraction: a powerful sample preparation tool prior to mass spectrometric analysis. Journal of Mass Spectrometry 2004;39(3):233-254. 54.劉秀玟. 以固相微萃取技術為基礎採樣分析空氣中甲醛的應用. 台灣大學環境衛生研究所碩士論文 2005. 55.Pawliszyn J. Solid phase microextraction: theory and practice. Wiley-VCH, Inc. 1997. 56.孫意惇. 以固相微萃取法及氣相層析-質譜儀檢測水中微量之4-壬基苯酚. 台灣大學環境衛生研究所碩士論文 2006. 57.楊宗逸. 以固相微萃取法結合可攜式氣相層析儀偵測二甲基硫和二甲基二硫之應用研究. 台灣大學環境衛生研究所碩士論文 2006. 58.Koziel J, Jia MY, Pawliszyn J. Air sampling with porous solid-phase microextraction fibers. Analytical Chemistry 2000;72(21):5178-5186. 59.Larroque V, Desauziers V, Mocho P. Comparison of two solid-phase microextraction methods for the quantitative analysis of VOCs in indoor air. Analytical and Bioanalytical Chemistry 2006;386(5):1457-1464. 60.Augusto F, Koziel J, Pawliszyn J. Design and validation of portable SPME devices for rapid field air sampling and diffusion based calibration. Analytical Chemistry 2001;73(3):481-486. 61.Lukic I, Banovic M, Persuric D, Radeka S, Sladonja B. Determination of volatile compounds in grape distillates by solid-phase extraction and gas chromatography. Journal of Chromatography A 2006;1101(1-2):238-244. 62.Garcia DDC, Reichenbacher M, Danzer K, Hurlbeck C, Bartzsch C, Feller KH. Investigations on wine bouquet components by solid-phase microextraction-capillary gas chromatography (SPME-CGC) using different fibers. Hrc-Journal of High Resolution Chromatography 1997;20(12):665-668. 63.Andresson K. Epidemiological approach to Indoor air problems. Indoor Air 1998;suppl 4:32-39. 64.行政院環境保護署環境檢驗所. 室內空氣中真菌濃度檢測方法. www.niea.gov.tw/intro.asp 2006. 65.行政院環境保護署環境檢驗所. 室內空氣中細菌濃度檢測方法. www.niea.gov.tw/intro.asp 2006. 66.吳欣橋. 台北市長期照護機構員工生物性職業暴露評估. 臺北醫學大學公共衛生學系研究所碩士論文 2006. 67.Wolkoff P, Wilkins CK, Clausen PA, Nielsen GD. Organic compounds in office environments - sensory irritation, odor, measurements and the role of reactive chemistry. Indoor Air 2006;16:7-19. 68.Meklin T, Hyva¨rinen A, Toivola M, Reponen T, Koponen V, Husman T, Taskinen T, Korppi M, Nevalainen A. Effect of building frame and moisture damage on microbiological indoor air quality in school buildings. AIHA Journal 2003;64:108-116. | |
dc.identifier.uri | http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/41901 | - |
dc.description.abstract | 近年來塑化建材在室內環境中使用越來越多,所造成的健康康效應漸漸受到重視。本研究調查在塑化建材的室內環境下2-乙基己醇、微生物及其他相關環境因子(通風、溫度、溼度、總揮發性有機氣體、總懸浮微粒)與病態大樓症候群的關係。
研究以問卷調查病態大樓症候群盛行的情形,採樣與分析室內空氣中2-乙基己醇及微生物濃度,並且以直讀式儀器測量溫度、溼度、總揮發性有機氣體及總懸浮微粒。 調查結果,如以「環境影響三項以上之不適症狀」做為病態大樓症候群的判別,其盛行率為40.7 %,如以「離開該不適環境後,不適症狀有改善者」做為病態大樓症候群的判別時該盛行率為66.5 %。在鋪設壁布的教室其不適的情形較高,經校正後仍為病態大樓症候群的危險因子,且不適症狀多為「黏膜刺激」(眼睛、鼻子及喉嚨等不適)。環境採樣分析發現,在鋪設壁布及地毯的室內空氣中2-乙基己醇濃度(65.1 μg/m3)顯著較高(p<0.01);而「上課期間」及「寒假期間」兩次採中,2-乙基己醇濃度皆與Penicillium濃度呈顯著線性相關(β=0.51, p<0.05);且小教室2-乙基己醇的濃度也顯著較高(211.3 μg/m3, p<0.01);剔除人及平常開門的通風條件影響時,2-乙基己醇濃度與溫度(β=0.64, p=0.03)和總細菌濃度(β=0.71, p=0.02)分別呈顯著線性相關。 總結,鋪設壁布及地毯、通風情形、教室體積大小、溫度、微生物等皆可能會影響2-乙基己醇的濃度,且可能與病態大樓症候群的發生有關,因此認為減少使用塑化建材做為裝潢的材料,以及增加通風的情形會有利於降低室內環境中2-乙基己醇的濃度。 | zh_TW |
dc.description.abstract | The possible health effect caused by plastic building materials that are getting popular in indoor environment, have been noticed. This study aims at disclosing sick building syndrome associated with 2-ethyl-1-hexanol, microorganisms and other factors such as ventilation, temperature, humidity, total volatile organic compounds and total suspended particulates in environment with the usage of plastic building materials.
A questionnaire survey was administrated for investigating the prevalence of sick building syndrome; 2-ethyl-1-hexanol and microorganisms (bacteria, fungi) were sampled and analyzed; other environmental factors such as temperature, humidity, total volatile organic compounds and total suspended particulates were measured by direct-reading instruments. The results indicated that, the prevalence of sick building syndrome was 40.7% when using 'three or more symptoms affected by environment' as a diagnosis base; the prevalence of sick building syndrome was 66.5% when using 'the symptoms became better when leaving uncomfortable environment ' as a diagnosis base. People felt uncomfortable in the environment installed with plastic carpet that was a significantly risk factor after adjusted for sick building syndrome. Major uncomfortable complaints were mucous membrane irritation involved in uncomfortable eyes, nose and throat. The mean concentration of 2-ethyl-1-hexanol in the room installed with carpet was 65.1 μg/m3 that was significantly higher than in the room without plastic carpet (p<0.01). During two sampling periods, schooling time and winter vacation, the concentrations of 2-ethyl-1-hexanol significantly correlated with the concentrations of Penicillium (β=0.51, p<0.05); the concentrations of 2-ethyl-1-hexanol in small classrooms significantly high (211.3 μg/m3, p<0.01); the concentrations of 2-ethyl-1-hexanol also significantly correlated with temperature (β=0.64, p=0.03) and total bacteria (β=0.71, p=0.02), respectively, when the factors of “people” and “the condition of ventilating” are excluded. In conclusion, the plastic carpet, ventilation, volume of room, temperature and microorganisms in indoor environment would affect the concentration of 2-ethyl-1-hexanol that probably relate to the prevalence of sick building syndrome. Thus, reducing the use of plastic building materials for inner decoration and providing adequate ventilation can decrease the concentrations of 2-ethyl-1-hexanol in indoor environment. | en |
dc.description.provenance | Made available in DSpace on 2021-06-15T00:36:33Z (GMT). No. of bitstreams: 1 ntu-98-R95844002-1.pdf: 1114074 bytes, checksum: ae262773d4f3ca1ab952d4b5c72a5b83 (MD5) Previous issue date: 2009 | en |
dc.description.tableofcontents | 誌謝 i
摘要 ii Abstract iii 目錄 v 表列 vii 圖列 ix 第一章 緒論 1 1.1 前言 1 1.2 研究目的 2 1.3 研究架構 2 第二章 文獻探討 3 2.1 室內空氣品質與病態大樓症候群的關係 3 2.2 室內環境與揮發性有機氣體的探討 4 2.2.1 塑化建材與2-乙基己醇的關係 5 2.2.2 2-乙基己醇之健康效應 6 2.3 室內微生物因子探討 8 2.4 固相微萃取技術 9 2.4.1 以固相微萃取採集環境空氣中2-乙基己醇之相關文獻 11 2.4.2 固相微萃取纖維選用 12 2.4.3 搭配可攜式氣相層析儀與火焰離子偵檢器 12 第三章 材料與方法 13 3.1 研究流程 13 3.2 病態大樓症候群問卷調查 14 3.3 環境採樣方法分析 15 3.3.1 環境採樣分析的場所、對象與採樣策略 15 3.3.2 教室大小、溫度、溼度、CO2、TSP、TVOC的測量 16 3.3.3 2-乙基己醇的採樣與分析 17 3.3.3.1 2-乙基己醇的採樣 17 3.3.3.2 2-乙基己醇的分析 17 3.3.4 生物氣膠的採樣與分析 20 3.3.4.1 真菌與細菌的採樣 20 3.3.4.2 真菌與細菌的分析 20 3.4 品質管理與品質控制 21 第四章 結果 22 4.1 病態大樓症候群的觀察 22 4.1.1 以「環境影響之不適症狀三項以上」做為病態大樓候群判定 23 4.1.2 以「離開不適環境後不適症狀有改善者」做為病態大樓候群判定 24 4.1.3 在鋪設壁布環境覺得不適之相關因子 25 4.2 室內環境空氣中2-乙基己醇的濃度 25 4.2.1 2-乙基己醇的固相微萃取採樣分析 25 4.2.2 2-乙基己醇環境採樣結果 26 4.3 室內環境中之溫度、溼度、CO2、TSP、TVOC及微生物採樣結果 26 4.4 檢視2-乙基己醇、環境參數及微生物間的相關性 27 4.5 以主成分分析檢視2-乙基己醇相關來源 29 第五章 討論 30 5.1 病態大樓症候群相關因子探討 30 5.1.1 與病態大樓症候群相關環境因子 32 5.1.2 與鋪設壁布環境相關不適因子 32 5.2 以固相微萃取採樣環境中2-乙基己醇的方法 33 5.3 環境中2-乙基己醇的情形 34 5.4 環境中CO2、溫溼度、TSP、TVOC及微生物的情形 34 5.5 2-乙基己醇與CO2、溫溼度、TSP及TVOC的關係 36 5.6 2-乙基己醇與真、細菌因子的關係 36 5.7 教室大小、CO2、溫溼度、TSP、TVOC與微生物的關係 37 5.8 研究限制 38 5.9 建議 40 參考文獻 41 附錄 114 | |
dc.language.iso | zh-TW | |
dc.title | 塑化建材、2-乙基己醇及微生物共存環境與病態大樓症候群的關係 | zh_TW |
dc.title | Environment with Plastic Building Materials, 2-Ethyl-1-hexanol and Microorganisms Related to Sick Building Syndrome | en |
dc.type | Thesis | |
dc.date.schoolyear | 97-1 | |
dc.description.degree | 碩士 | |
dc.contributor.oralexamcommittee | 陳保中,張靜文 | |
dc.subject.keyword | 室內空氣品質,塑化建材,2-乙基己醇,揮發性有機氣體,微生物,病態大樓症候群, | zh_TW |
dc.subject.keyword | Indoor air quality,plastic building materials,2-ethyl-1-hexanol,volatile organic compounds,microorganisms,sick building syndrome, | en |
dc.relation.page | 125 | |
dc.rights.note | 有償授權 | |
dc.date.accepted | 2008-12-11 | |
dc.contributor.author-college | 公共衛生學院 | zh_TW |
dc.contributor.author-dept | 環境衛生研究所 | zh_TW |
顯示於系所單位: | 環境衛生研究所 |
文件中的檔案:
檔案 | 大小 | 格式 | |
---|---|---|---|
ntu-98-1.pdf 目前未授權公開取用 | 1.09 MB | Adobe PDF |
系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。