Skip navigation

DSpace

機構典藏 DSpace 系統致力於保存各式數位資料(如:文字、圖片、PDF)並使其易於取用。

點此認識 DSpace
DSpace logo
English
中文
  • 瀏覽論文
    • 校院系所
    • 出版年
    • 作者
    • 標題
    • 關鍵字
    • 指導教授
  • 搜尋 TDR
  • 授權 Q&A
    • 我的頁面
    • 接受 E-mail 通知
    • 編輯個人資料
  1. NTU Theses and Dissertations Repository
  2. 生物資源暨農學院
  3. 生物機電工程學系
請用此 Handle URI 來引用此文件: http://tdr.lib.ntu.edu.tw/jspui/handle/123456789/34073
完整後設資料紀錄
DC 欄位值語言
dc.contributor.advisor方煒(Wei Fang)
dc.contributor.authorXin-Yu Chenen
dc.contributor.author陳欣榆zh_TW
dc.date.accessioned2021-06-13T05:53:26Z-
dc.date.available2013-08-23
dc.date.copyright2011-08-23
dc.date.issued2011
dc.date.submitted2011-08-19
dc.identifier.citation1. 方煒。2001。自動化植物工廠。農業自動化叢書第十一輯:103-112。
2. 方煒。2010。 以植物工廠生產農作物與綠能產業研究發展。國立臺灣大學生物資源暨農學院院訊10期:7-10。
3. 方煒。2010。 植物工廠是新世紀發展精緻農業具前瞻性的關鍵產業。中國時報。
4. 方煒。2006。冷凍空調熱泵與雙層充氣塑膠布應用於蝴蝶蘭催花與抑梗溫室。
5. 方煒。1995。溫室蒸發冷卻系統降溫效果量化指標之建立。農業機械學刊。4(2):15-25。
6. 方煒、陳育緯。2005。雙效型冷凍空調熱泵及其在生物產業的應用。生機發表會。
7. 卓昆範。2008。建立結合熱泵與太陽能之熱水主機與網路管理。碩士論文。台北:台灣大學生物產業機電工程研究所。
8. 祝保英、滕光輝、王平智。2004。基于熱電制冷技術的營養液溫控系統的試驗研究。大陸:中國農業大學學報:23-26。
9. 馬一太、王軍亮、呂山仁。1992。熱泵主機自動變頻調素容量調節研究。天津大學學報。2(3):114-120。
10. 陳瑞和。1991。感測器初版。台北:全華科技圖書股份有限公司。
11. 張道弘 編譯。1997。PID 控制理論與實務。2-35。台北:全華科技圖書股份有限公司。
12. 張潔、張良俊、王如竹、吳靜怡。2007。空熱泵製冷系統主機優化計算與實驗研究。太陽能學報。28(3):286-290。
13. 馮玉龍、劉恩舉、崔臻祥。1995。根系溫度對番茄光合作用和水分代謝的影響。
14. 曾博群。2009。自製泛用型多功能熱泵於不同操作條件下性能係數之探討。碩士論文。台北:台灣大學生物產業機電工程研究所。
15. 蓋玉恬。2008。鈣及根溫處理對胡瓜”夏笛”生育及產量之影響。
16. 劉雪玲、朱家玲。2005。水源式熱泵在冬季供暖的應用。太陽能學報。26(2):262-265。
17. 蔡致榮、吳有恒。2010。農業設施節能技術與系統研發。農業試驗所特刊第150號:38-69。
18. Bennett, S. (2001). The past of pid controllers. Annual Reviews in Control 25: 43-53.
19. Biaou, A. and M. Bernier. 2008. Achieving total domestic hot water production with renewable energy. Building and Environment. 43(4): 651-660.
20. Chow, J. J. Pei, T. Dong, G. He, J. W. 2003. Domestic air-conditioner and integrated water heater for subtropical climate. Applied Thermal Engineering. (23):581–592.
21. Guo, X. M., Y. G. Chen, W.-H. Wang, C.-Z. Chen. 2008. Experimental study on frost growth and dynamic performance of air source heat pump system. Applied Thermal Engineering. 28(17-18): 2267-2278.
22. Hepbasli, A. and Y. Kalinci. 2009. A review of heat pump water heating systems. Renewable and Sustainable Energy Reviews. 13(6-7): 1211-1229.
23. Kumar, K.S, K.N. Tiwari, M. K. Jha. 2009. Design and technology for greenhouse cooling in tropical and subtropucal regions:A review. Energy and Buildings. 41:1269-1275.
24. Thompson, H., R. Langhans, A. Both, L. Albright. 1998. Shoot and root temperature effects on lettuce growth in a floating hydroponic system. American Society for Horticultural Science (USA). 123(3): 361-364.
25. Valino, V., A. Perdigones, J. L. Garcia, L. Luna. 2010. Experimental evaluation of a radiant heated floor coupled to an air-to-water heat pump for the cooling of greenhouses. Spanish Journal of Agricultural Research. 8(3):580-591.
26. Ziegler, J. G. and N. B. Nichols. 1942. Optimum settings for automatic controllers. Transactions of the A.S.M.E. 11:759-765.
dc.identifier.urihttp://tdr.lib.ntu.edu.tw/jspui/handle/123456789/34073-
dc.description.abstract植物工廠作為解決全球暖化、可耕地縮減、糧食短缺、淡水資源與能源匱乏及食品安全等全球性問題之高潛力技術之一,近來頗受矚目。然而,在室內完全使用人工光源進行作物栽培時,維持植物生長所需光量與維持室內溫、溼度所需空調系統的能源負荷為操作成本之最大支出。降低此部分的光熱成本為首要研究課題與成功關鍵。
本研究旨在針對空調系統的能耗進行探討,期望能透過熱泵製冷系統的使用,在降低環控室內的空氣溫度與降低栽培所需的養液溫度之間,找到一個平衡點,使整體耗能為最小。本研究針對A-W與A-R兩型熱泵系統進行探討,前者透過板式熱交換器將水槽內的水與蒸發器內的冷媒做熱交換,後者則是直接將蒸發器置於水槽內對水體做降溫。熱泵製冷系統不論是哪一型,其性能係數 (COP) 若是比市售空調系統低,則沒有應用空間。研究中使用之A-W型設備的COP 遠高於A-R型。本研究應用熱泵製冷系統確立了可以同時用於養液與室內空氣的降溫。
本研究也針對單一的栽培層架進行小區域降溫,避免針對整間環控室作降溫,以節約能源消耗。溫控栽培層架的設計,配合水冷排、風扇、沉水馬達、水槽與養液槽的使用,將熱泵製冷系統所製造的冰水,用於空間內與養液的降溫,允許各層空間內可以有不同或相同的氣溫,提高應用於研究上的彈性。
zh_TW
dc.description.abstractFacing the global problems such as global warming, exploded population, reduction in cultivated land, food shortage, fresh water and energy crisis and food safety, plant factory is considered one of the promising methods to solve the problems, thus catching lots of attention recently. However, grow plants indoor takes lots of energy to provide light needed by the crop and to maintain proper temperature and humidity. The cost on artificial light plus the cost on air conditioning system is the major operating cost, thus reducing these light-heat related cost is the major task for the related research and successful business.
This study aims at reducing air conditioning cost by applying heat pump system. The goal is to find a balance between reducing air temperature and nutrient temperature. Traditionally, only air temperature was controlled. This study tried to control the nutrient temperature and let the air temperature several degree higher and to compare the energy consumption throughout the entire growth period. Two types of heat pump cooling system were used. A-W type used a plate type exchanger to exchange energy between water in tank and refrigerant in evaporator. A-R type put the evaporator in water tank directly. No matter which type was used, the COP of the system is the major concern, if the COP is less than the commercially available Air conditioning system, there is making no sense to use it. In our experiment, the COP of A-W is much higher than A-R type. This study successfully set up a heat pump cooling system suitable or air cooling and nutrient solution cooling at the same time.
A cooling system for multi-layer bench was established. The system consists of water cooled heat exchanger for each layer, fans attached to the heat-exchangers, submersible pump, nutrient tank and tap water tank which cooled with heat pump cooling system, and can be used to keep temperatures of the air within each layer and temperature of nutrient for the whole bench in different level, thus making it a flexible system for research.
en
dc.description.provenanceMade available in DSpace on 2021-06-13T05:53:26Z (GMT). No. of bitstreams: 1
ntu-100-R98631001-1.pdf: 3382858 bytes, checksum: 94a6e742ed279629c6a83b50f2d04573 (MD5)
Previous issue date: 2011
en
dc.description.tableofcontents誌謝 i
摘要 ii
Abstract iii
目錄 v
圖目錄 vii
表目錄 x
第一章 前言與研究目的 1
1-1 前言 1
1-2 研究目的 2
第二章 文獻探討 3
2-1 熱泵系統 3
2-1-1 熱泵系統的介紹 3
2-1-2 熱泵系統在製冷方面 7
2-1-3 熱泵系統的性能提升 7
2-1-4 熱泵系統的應用實例 9
2-2 PID控制 12
2-2-1 PID控制介紹 12
2-2-2 PID控制參數設定 14
2-2-3 PID控制應用 15
2-3 植物工廠 17
2-3-1 植物工廠介紹 17
2-3-2 植物工廠降溫 20
2-3-3 植物工廠水耕栽培 22
第三章 材料與方法 24
3-1 實驗設備 24
3-1-1 熱泵系統 24
3-1-2 溫控層架系統 29
3-1-3 溫度控制系統 31
3-1-4 量測元件 33
3-2 研究方法 34
3-2-1 熱泵製冷設備之COP量測 34
3-2-2 量產型植物工廠養液降溫 34
3-2-3 溫控層架系統的穩定性 35
3-2-4 養液溫度與空氣溫度對芝麻菜的生長影響 35
第四章 結果與討論 38
4-1 兩型熱泵製冷系統的比較 38
4-2 A-R型熱泵製冷性能提升 40
4-3 植物工廠養液降溫與空調節能 41
4-3-1 A-R型熱泵製冷系統在環控室內的養液降溫 41
4-3-2 溫控層架系統 45
4-4 兩階段栽種芝麻菜之空氣與養液溫控 49
第五章 結論與建議 51
5-1 結論 51
5-2 建議 52
參考文獻 53
dc.language.isozh-TW
dc.subject性能係數zh_TW
dc.subject熱泵製冷zh_TW
dc.subject植物工廠zh_TW
dc.subject節能zh_TW
dc.subjectHeat pump coolingen
dc.subjectPlant factoryen
dc.subjectCoefficient of performanceen
dc.subjectEnergy savingen
dc.title熱泵應用於植物工廠養液降溫與室內空調zh_TW
dc.titleApplying Heat Pump in Plant Factory for the Cooling of Nutrient Solution and Indoor Airen
dc.typeThesis
dc.date.schoolyear99-2
dc.description.degree碩士
dc.contributor.oralexamcommittee蔡致榮,黃振康
dc.subject.keyword植物工廠,熱泵製冷,性能係數,節能,zh_TW
dc.subject.keywordPlant factory,Heat pump cooling,Coefficient of performance,Energy saving,en
dc.relation.page55
dc.rights.note有償授權
dc.date.accepted2011-08-21
dc.contributor.author-college生物資源暨農學院zh_TW
dc.contributor.author-dept生物產業機電工程學研究所zh_TW
顯示於系所單位:生物機電工程學系

文件中的檔案:
檔案 大小格式 
ntu-100-1.pdf
  未授權公開取用
3.3 MBAdobe PDF
顯示文件簡單紀錄


系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

社群連結
聯絡資訊
10617臺北市大安區羅斯福路四段1號
No.1 Sec.4, Roosevelt Rd., Taipei, Taiwan, R.O.C. 106
Tel: (02)33662353
Email: ntuetds@ntu.edu.tw
意見箱
相關連結
館藏目錄
國內圖書館整合查詢 MetaCat
臺大學術典藏 NTU Scholars
臺大圖書館數位典藏館
本站聲明
© NTU Library All Rights Reserved